Search PubMed⌕ Search

Biomedical subjects

R Mischke

Publications and source records attributed to R Mischke.

92 records · Page 6Linked to original sources

[Cyclosporin A therapy in a cat with pure red cell aplasia].

The case of a one year and 7 months old castrated male cat suffering from severe, non regenerative anaemia (packed cell volume: 8.6%; reticulocyte count: 1/1000) is presented. A combined ELISA-test for feline leukaemia virus antigen and antibodies against feline immunodeficiency virus was negative. Using indirect Coomb's test IgM as well as the complement component C3b could be demonstrated on the erythrocytes. Cytological investigation of the bone marrow revealed a selective, nearly complete aplasia of the erythropoiesis. Immunosuppressive therapy with cyclosporin A (6.25 mg/kg BW orally, twice daily) and prednisolone (initially 5 mg/kg BW intravenously, twice daily) from the 9th day on led to a distinct regeneration of erythropoiesis with reticulocyte counts up to 126/1000 (341.000/microliter) and normalisation of the red blood picture as well as the general state of health. The therapy with cyclosporin A was continued for five months, reducing the dosis after 30 days to 6.25 mg/kg BW orally once daily corresponding to an extremely high blood level of cyclosporine A. At control examinations 24 and 63 days after depositing therapy all parameters of the red blood picture were within the reference range. This case report indicates that pure red cell aplasia can be due to an autoimmune process in cats also as well.

Animals↗

[Clinical evaluation of platelet function analyzer PFA-100 in dogs].

The platelet-function-analyzer PFA-100 (Fa. Dade Behring, Liederbach) proofs the capillary in vitro bleeding time by the blood flow through a capillary. The membrane at the end of the capillary is a membrane with a layer of an inductor of the platelet aggregation (collagen/ADP or collagen/epinephrine). The closure time and optional the blood volume flowing out of the capillary can be determined. To find out the applicability of the analyzer for canine blood samples several examinations were carried out in this study. Based on 45 blood samples of clinically healthy dogs a reference range (2.5%- and 97.5% quantile) was defined. Using the collagen/ADP test cartridge the reference range for the closure time was 47-81 s and for the blood volume 223-303 microliters. Using the collagen/epinephrine test cartridge the reference range for the closure time was 67-210 s and for the blood volume 269-611 microliters. In addition, blood samples (n = 19) of dogs with different degrees of thrombocytopenia were examined. Hereby, in contrast to the collagen/epinephrine cartridge, the collagen/ADP cartridge showed a high sensitivity regarding the closure time (n = 18) as well as the blood volume (n = 17). Regarding the results of the healthy dogs and dogs with thrombocytopenia a moderate close correlation was calculated between the in vitro bleeding time and the capillary in vivo bleeding time (rs = 0.590). After intravenous injection of 20 mg/kg acetylsalicylic acid the closure time measured with the collagen/ADP cartridge was 1.3 fold prolonged. The reference range was not exceeded in every case. With artificial variation of the haematocrit a clear prolongation of the closure time at haematocrit values < or = 25% was demonstrated. These results indicate that clinical usability of the platelet function analyzer in dogs is restricted despite its sensitivity to disorders of primary haemostasis.

Animals↗