Search PubMed⌕ Search

Biomedical subjects

R Menapace

Publications and source records attributed to R Menapace.

At least 37 records · Page 2Linked to original sources

Effects of peribulbar anesthesia on ocular blood flow in patients undergoing cataract surgery.

PURPOSE: The effects of extraconal, peribulbar anesthesia on ocular blood flow may be caused by concomitant elevations in intraocular pressure or direct pharmacologic alteration of vascular tone. We quantified the effect on ocular circulation with a new technique for assessment of ocular hemodynamics. METHODS: In a prospective study, ocular hemodynamics were measured before and 1 and 5 minutes after peribulbar anesthesia in 22 eyes with age-related cataract. Measurements included fundus pulsation amplitude with a laser interferometric method assessing the pulsatile choroidal blood flow and mean blood flow velocity as well as resistive index in the ophthalmic and central retinal artery with Doppler sonography. Systemic blood pressure and pulse were monitored throughout the period of ocular hemodynamic measurements. RESULTS: Fundus pulsation amplitude decreased significantly after peribulbar anesthesia (after 1 minute and 5 minutes: -13% and -8%; P < .001). In the central retinal artery, mean blood flow velocity dropped (-15%; P < .001) and resistive index increased (+3%; P = .02) 1 minute after peribulbar anesthesia compared with baseline. There were no changes in ophthalmic artery hemodynamics. Intraocular pressure was elevated 1 minute after peribulbar anesthesia (+29%; P = .003) but reached baseline values after 5 minutes. CONCLUSION: Pulsatile choroidal blood flow and retinal blood flow velocities were reduced after peribulbar anesthesia. These reductions were still present 5 minutes after peribulbar anesthesia, when intraocular pressure had returned to baseline values. This supports the theory of drug-induced vasoconstriction after peribulbar anesthesia. A loss of vision may be a risk of peribulbar anesthesia in patients who have compromised ocular blood flow before surgery.

Adult↗

Changes in intraocular lens position after neodymium: YAG capsulotomy.

PURPOSE: To quantify changes in intraocular lens (IOL) position caused by neodymium: YAG (Nd:YAG) capsulotomy with 3 IOL styles. SETTING: Department of Ophthalmology, University of Vienna, Austria. METHODS: In a prospective study, anterior chamber depth (ACD) was measured by dualbeam partial coherence interferometry (PCI) in 32 pseudophakic eyes of 32 patients with posterior capsule opacification before and immediately after planned capsulotomy under mydriasis. Patients were divided into 3 groups with the following IOL styles: 1-piece poly(methyl methacrylate) (PMMA), 3-piece foldable, and plate haptic. RESULTS: The capsulotomy induced a backward IOL movement in all 32 eyes (mean 25 microns; range 9 to 55 microns). It was more pronounced in eyes with plate-haptic IOLs than in those with the other styles. Precision of ACD measurement by PCI was 4 microns. Changes in ACD correlated significantly with capsulotomy size but not with preoperative lens-capsule distance. CONCLUSION: Capsulotomy caused a backward movement of the IOL, which was more pronounced with plate-haptic IOLs than with 1-piece PMMA and 3-piece foldable IOLs. Since the magnitude of IOL movement in this study population was small, a hyperopic shift in refraction after capsulotomy will usually be small and not clinically relevant.

Adult↗

Contact zone of piggyback acrylic intraocular lenses.

In a hyperopic cataract patient, surgery was performed with implantation of 2 foldable, acrylic, posterior chamber intraocular lenses (IOLs) in the bag. The IOLs showed a central contact zone during surgery. This contact zone remained after surgery and was documented 2 months postoperatively. The contact zone may induce multifocality similar to that seen with multifocal IOLs.

Acrylic Resins↗

Effect of small incision cataract surgery on ocular blood flow in cataract patients.

PURPOSE: To evaluate the effect of small incision cataract surgery using peribulbar anesthesia on ocular blood flow in patients with senile cataract. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: In 33 eyes of 33 consecutive patients scheduled for cataract surgery, ocular hemodynamics were measured preoperatively and 1 day, 1 week, and 1 month postoperatively. Measurements included fundus pulsation amplitude (FPA) with a laser interferometric method that assessed the pulsatile choroidal blood flow, mean blood flow velocity (MFV), and resistive index (RI) in the ophthalmic artery (OA) and the central retinal artery (CRA) with Doppler sonography. Systemic hemodynamics and intraocular pressure (IOP) also were measured. RESULTS: The FPA, MFV, and RI in the OA and the CRA did not change postoperatively from baseline values. Systemic hemodynamics, IOP, and as a consequence ocular perfusion pressure, also remained unchanged. CONCLUSION: Uneventful small incision cataract surgery using peribulbar anesthesia did not affect ocular blood flow in patients with senile cataract between 1 day and 1 month postoperatively.

Adult↗

Corneal shape changes after temporal and superolateral 3.0 mm clear corneal incisions.

PURPOSE: To compare the corneal topographic changes after temporal and superolateral 3.0 mm clear corneal incisions (CCIs) and implantation of foldable silicone intraocular lenses (IOLs). SETTING: Department of Ophthalmology, University of Vienna, Austria, and a private clinic, Winterthur, Switzerland. METHODS: This prospective study comprised 54 eyes of 54 patients scheduled for cataract surgery. After a 0.3 mm deep precut, a temporal 3.0 mm CCI was made in 26 eyes and a superolateral (at 10:30) 3.0 mm CCI in 28 eyes. Corneal topography was recorded preoperatively and 1 week and 1 and 3 months postoperatively using the TMS-1 computer-assisted videokeratoscope (Computed Anatomy, Inc.). Surgically induced corneal shape changes were evaluated by batch-by-batch analyses of the paired differences between the records. The significance of topographic changes was calculated by the paired Wilcoxon test; group comparisons were made using the Wilcoxon group comparison test. RESULTS: Both groups had incision-related corneal flattening at 1 week and 1 and 3 months postoperatively. The extent of this flattening at 1 week and 1 and 3 months postoperatively was up to 1.0, 0.9, and 0.7 diopter (D), respectively, in the temporal group and up to 1.2 D at each observation time in the superolateral group. There was statistically significantly more incision-related corneal flattening in the superolateral incision group than in the temporal incision group; the difference was up to 0.3 D after 1 month and 0.5 D after 3 months. CONCLUSION: The superolateral incision induced statistically significantly more incision-related corneal flattening than the temporal incision.

Astigmatism↗

Prediction of pseudophakic capsular bag diameter based on biometric variables.

PURPOSE: To measure the capsular bag diameter (CBDm) in vivo and calculate a regression formula for future preoperative prediction of capsular bag diameter (CBDp). SETTING: Department of Ophthalmology, University of Vienna, Austria. METHODS: This prospective study comprised 70 eyes having cataract surgery with implantation of an open capsular tension ring (CTR) (Morcher Type 14). Within the first postoperative days, the distance between the ends of the CTR were measured through a gonioscopy lens by adjusting the slit height. This distance was added to the known length of the CTR to calculate the capsular bag circumference and from this, the CBDm. The CBDm was correlated with axial eye length (AL), corneal power (P), preoperative anterior chamber depth and lens thickness, corneal diameter, and age. A stepwise multiple regression analysis was computed with CBDm as the dependent variable. RESULTS: The mean CBDm was 10.37 mm +/- 0.25 (SD). A statistically significant negative correlation was found between CBDm and P (P < .0004; r2 = 0.16) and a positive correlation between CBDm and AL (P < .0226, r2 = 0.07). Stepwise multiple regression resulted in the following regression formula: CBDp = 3.44 to 0.056 x P + 0.713 x AL - 0.0135 x AL2 (P < .0001; r2 = 0.3145). Using this formula with the individual Ps and ALs, all 6 eyes with a large capsular bag diameter (CBDm > 10.7 mm) and 10 of 13 eyes with a small one (CBDm < 10.1 mm) were correctly classified. CONCLUSION: The capsular bag diameter in vivo correlated negatively with corneal power (P) and positively with AL. The regression formula used may serve as a tool for preoperative identification of eyes with a very large or very small CBDm.

Aged↗

Effect of dorzolamide and latanoprost on intraocular pressure after small incision cataract surgery.

PURPOSE: To evaluate the effect of dorzolamide 2% and latanoprost 0.005% on intraocular pressure (IOP) after small incision cataract surgery. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective study comprised 102 eyes of 102 consecutive patients scheduled for small incision cataract surgery. The patients were assigned preoperatively to 1 of 3 groups of 34 each: dorzolamide, latanoprost, and control (no treatment). One drop of the assigned medication was instilled immediately after surgery. Intraocular pressure was measured preoperatively and 6 and 20 to 24 hours postoperatively. RESULTS: Six hours after surgery, the mean increase in IOP was 1.9 mm Hg +/- 3.9 (SD) in the dorzolamide group (P = .004 versus control), 2.2 +/- 3.0 mm Hg in the latanoprost group (P = .005 versus control), and 4.8 +/- 5.2 mm Hg in the control group. Twenty to 24 hours postoperatively, IOP decreased a mean of -0.9 +/- 3.5 mm Hg in the dorzolamide group (P = .012 versus control) and increased a mean of 0.3 +/- 3.6 mm Hg in the latanoprost group (P = 0.24 versus control) and 1.3 +/- 4.2 mm Hg in the control group. One eye in the dorzolamide group, 1 eye in the latanoprost group, and 4 eyes in the control group had an IOP of 30 mm Hg or higher 6 hours postoperatively. CONCLUSION: Six hours postoperatively, dorzolamide and latanoprost were effective in reducing the IOP increase after small incision cataract surgery; however, at 20 to 24 hours, only dorzolamide was effective. Neither drug prevented IOP spikes of 30 mm Hg or higher.

Aged↗

Partial coherence interferometry: a novel approach to biometry in cataract surgery.

PURPOSE: To compare biometry performed by an enhanced version of dual beam partial coherence interferometry and applanation ultrasound in a prospective study of 85 cataract eyes to improve refractive outcome of cataract surgery due to a more accurate calculation of intraocular lens power. METHODS: The SRK II formula using ultrasound biometry data was employed. Three months after surgery, partial coherence interferometry biometry was repeated and refractive outcome was determined. Preoperative partial coherence interferometry biometry data were used to determine the refractive power of the intraocular lenses retrospectively and to calculate the possible refractive outcome. RESULTS: Precision of partial coherence interferometry biometry was more than 10 times better than that of ultrasound. Therefore, the possible mean absolute error for postoperative refraction achieved with partial coherence interferometry biometry was 0.49 diopters (compared with 0.67 diopters with ultrasound biometry), resulting in an improvement of 27%. Axial eye length measured with the two techniques differed by a mean of 460 microm. The difference in lens thickness measured with partial coherence interferometry and ultrasound significantly correlated with cataract grade. A mean shortening of 120 microm of axial eye length following cataract surgery was also detected by partial coherence interferometry. CONCLUSIONS: The enhanced version of partial coherence interferometry offers biometry with unprecedented precision (<10 microm) and resolution (approximately 12 microm), therefore improving the refractive outcome in cataract surgery. This noninvasive technique provides a high degree of comfort for the patient, with no need for local anesthesia or pupil dilation and minimized risk of corneal infection.

Adult↗

Reversal of endothelin-1-induced ocular hemodynamic effects by low-dose nifedipine in humans.

BACKGROUND AND PURPOSE: There is evidence that calcium channel blockers may be useful in patients with normal tension glaucoma and vasospastic reactions. We therefore hypothesized that calcium channel blockers may increase ocular blood flow and that there may be a functional antagonism between endothelin-1 (ET-1) and calcium channel blockers in the ocular vasculature. METHODS: This was a randomized, double-blind, three-way crossover study with respect to ET-1 infusions (placebo, 2 ng/kg/min ET-1, and 4 ng/kg/min ET-1) and a randomized double-blind study in two parallel groups with respect to nifedipine (placebo or 5 mg nifedipine). Ocular hemodynamics in the 12 healthy subjects participating in the study was assessed by laser interferometric measurement of fundus pulsation amplitude (FPA) in the optic disc and two-dimensional scanning laser Doppler flowmetry in the optic disc. RESULTS: ET-1 caused a dose-dependent decrease in FPA and flow. With a dose of 4 ng/kg/min a decrease of -18% +/- 5% (p < 0.001) and -17% +/- 5% (p = 0.023) on FPA and flow, respectively, were observed. This effect was completely reversed by nifedipine compared with placebo (FPA, p < 0.001; flow, p = 0.011). However, nifedipine did not affect ocular hemodynamics after placebo infusion. CONCLUSIONS: These results show that nifedipine does not increase optic nerve head blood flow during baseline conditions but reverses ET-1-induced constriction in ocular vasculature at doses that do not affect systemic hemodynamics. This supports the close relation of the therapeutic effect of calcium channel blockers in patients with normal tension glaucoma to the endothelin system. Moreover, the present study provides a strong rationale for a study of low dose nifedipine as a supplementary medication in glaucoma patients.

Adult↗

High precision biometry of pseudophakic eyes using partial coherence interferometry.

PURPOSE: To investigate the applicability of the scanning version of dual-beam partial coherence interferometry (PCI) for measuring the anterior segment and axial length of pseudophakic eyes in a clinical setting and to determine the achievable precision with this biometry technique. SETTING: Department of Ophthalmology, Vienna General Hospital, and Institute of Medical Physics, University of Vienna, Austria. METHODS: Partial coherence interferometry was performed in 39 pseudophakic eyes of 39 patients after implantation of a foldable acrylic intraocular lens (IOL). RESULTS: Effective lens position (ELP), IOL thickness and lens-capsule distance (LCD) were determined with a precision of 2 to 3 microns; corneal thickness and axial eye length, with a precision of 0.8 and 5.0 microns, respectively. The mean ELP of the IOL was 4.093 mm +/- 0.290 (SD). In 7 eyes (18%), a positive LCD of 68 +/- 40 microns was detected with PCI. Mean corneal thickness was 526.4 +/- 31.5 microns; mean IOL thickness, 791.5 +/- 40.2 microns; and mean axial length, 23.388 +/- 0.824 mm. CONCLUSION: The scanning version of PCI enables high precision (< or = 5 microns) and high resolution (approximately 12 microns) biometry of pseudophakic eyes that is better than conventional ultrasound by a factor of more than 20. For the first time, positive LCD, a possible risk factor for posterior capsule opacification, could be detected and quantified. Furthermore, this technique offers a high degree of comfort for the patient since it is a noncontact method with no need for local anesthesia or pupil dilation and has a reduced risk of corneal infection.

Acrylates↗

Accurate determination of effective lens position and lens-capsule distance with 4 intraocular lenses.

PURPOSE: To measure effective lens position (ELP) of 4 intraocular lenses (IOLs) using high precision and high resolution dual-beam partial coherence interferometry (PCI) and to assess the tendency of these IOLs to produce a lens-capsule distance (LCD), a possible risk factor for posterior capsule opacification. SETTING: Department of Ophthalmology, Vienna General Hospital; Institute of Medical Physics, University of Vienna, Austria. METHODS: In a retrospective study, PCI was used to measure ELP and LCD in 139 pseudophakic eyes of 110 patients with 4 IOLs: acrylic 3-piece IOL (AcrySof MA60BM); silicone 3-piece IOL without a capsular tension ring (PhacoFlex SI30) and with a capsular tension ring (PhacoFlex SI30 and Morcher Type 14); silicone plate-haptic IOL (Staar AA4203VF); and a hydrogel plate-haptic IOL (logel 1103). RESULTS: The ELP and LCD were determined with a precision of approximately 3 to 4 microns. An LCD was detected in 21% eyes with the AcrySof, 20% of eyes with the SI30 without a capsular tension ring, 10% of eyes with a capsular tension ring, 21% of eyes with the Staar, and 17% of eyes with the logel. The LCDs detected by PCI, but not by slitlamp examination, were significantly smaller than those detected by both. CONCLUSION: The amount of LCD detected by PCI was approximately the same with all IOL types (approximately 20%) except the PhacoFlex SI30 with a capsular tension ring (10%).

Acrylates↗

Comparative study of corneal topographic changes after 3.0 mm beveled and hinged clear corneal incisions.

PURPOSE: To compare the corneal topographic changes after cataract surgery using 2 types of clear corneal incisions (CCIs). SETTING: Department of Ophthalmology, University of Vienna, Austria. METHODS: This prospective, unmasked, nonrandomized study comprised 64 eyes scheduled for cataract surgery; 29 eyes received a temporal sutureless 3.0 mm corneal beveled CCI and 35 eyes, a temporal sutureless 3.0 mm hinged CCI. Preoperatively and 1 week, 1 and 3 months, and 1 year postoperatively, corneal topography was recorded by computer-assisted videokeratoscopy (TMS-1, Computed Anatomy, Inc.). Data were evaluated by batch-by-batch analyses of the paired differences between these records. The significance of topographic changes was calculated by paired Wilcoxon tests, and group comparisons were made using Wilcoxon tests. RESULTS: In both groups, there was statistically significant horizontal flattening and lower corneal steepening (P < .01). The horizontal flattening decreased between 1 week and 1 year, from -0.6 to -0.3 diopter (D) in the beveled-incision group and -0.7 to -0.4 D in the hinged-incision group. Vertical steepening was significant in the lower corneal region and decreased between 1 week and 1 year, from 0.3 to 0.2 D. Group comparisons revealed significant differences in an oblique lower temporal semimeridian, with 0.1 to 0.3 D more steepening after the hinged incision than after the beveled incision (P < .05). CONCLUSION: There were only minimal differences between beveled and hinged CCIs in surgically induced corneal shape changes.

Cornea↗

Ultrastructure of clear corneal incisions. Part I: Effect of keratomes and incision width on corneal trauma after lens implantation.

PURPOSE: To examine the ultrastructure of clear corneal incisions (CCIs) performed with diamond keratomes and steel blades as well as the corneal trauma after implantation of a foldable intraocular lens (IOL) through two incision widths. SETTING: University Eye Clinic and Institute of Histology and Embryology II, University of Vienna, Austria. METHODS: Twenty-four human cadaver eyes without prior ocular surgery were obtained from the University Eye Bank, Vienna. Single-plane CCIs were performed with 3.0 and 3.2 mm Alcon steel blades and with a 3.0 mm Huco diamond keratome. The AMO PhacoFlex II lens was implanted with a Fine II folder. During the entire procedure, the eye pressure was kept between 26 and 30 mm Hg by infusing balanced salt solution into the anterior chamber. Specimens were prepared for light microscopy, transmission electron microscopy, and scanning electron microscopy according to standard procedures. RESULTS: The diamond keratome produced cleaner cuts than the steel blade. After IOL implantation, 3.0 mm steel blade incisions exhibited extensions at their lateral ends. Within these extensions, the collagen lamellae were displaced and torn. This was not true with 3.2 mm tunnels. Because of the thickness of a 3.0 mm diamond keratome, the extent of corneal trauma was between that found with 3.0 and 3.2 mm steel keratome tunnels. CONCLUSIONS: Implantation of the SI-30 through 3.0 mm CCIs produced by the steel blade led to more severe corneal trauma than implantation through 3.2 mm steel blade incisions or 3.0 mm diamond keratome incisions. Thus, IOL implantation through incisions that are too small intensifies corneal trauma.

Aged↗

Ultrastructure of clear corneal incisions. Part II: Corneal trauma after lens implantation with the Microstaar injector system.

PURPOSE: To examine the ultrastructure of clear corneal incisions (CCIs) after implantation of a plate-hepatic intraocular lens (IOL) with the Microstaar injector system through two incision widths. SETTING: University Eye Clinic and Institute of Histology and Embryology II, University of Vienna, Austria. METHODS: Fourteen human cadaver eyes without prior ocular surgery were obtained from the University Eye Bank, Vienna. Single-plane CCIs were performed with 3.0 and 3.2 mm steel keratomes. Using the Microstaar injector system, a foldable silicone plate-haptic IOL (23 diopters) was implanted in the anterior chamber. During the entire procedure, the eye pressure was kept between 26 and 30 mm Hg by infusing balanced salt solution into the anterior chamber. Specimens for light microscopy and scanning electron microscopy were prepared according to standard procedures. RESULTS: After IOL implantation, the 3.0 mm steel blade incisions exhibited distinct distensions at their lateral ends. Adjacent to these distensions, the collagen lamellae were pressed apart, displaced, and torn. In 3.2 mm tunnels, the corneal trauma at both lateral ends was considerably less severe. These incisions also showed a better primary adaptation of the wound lips after implantations. CONCLUSIONS: Implantation performed with the Microstaar injector system through 3.0 mm steel blade CCIs led to considerably more severe corneal trauma than implantation through 3.2 mm incisions.

Aged↗

Long-term course of surgically induced astigmatism after a 5.0 mm sclerocorneal valve incision.

PURPOSE: To study surgically induced astigmatism (SIA) after a sutureless 5.0 mm sclerocorneal valve incision. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This study evaluated SIA in 34 cases of sutureless cataract surgery with a 5.0 mm superior sclerocorneal valve incision and implantation of a poly(methyl methacrylate) intraocular lens. Keratometry was measured with a Zeiss keratometer in all cases preoperatively, and 1 day, 1 week, 1 and 3 months, and 1 and 5 years postoperatively. RESULTS: Surgically induced astigmatism, calculated by Cravy's vector analysis, showed an initial mean with-the-rule shift of 0.35 diopter (D), followed by an against-the-rule shift to a mean of -0.30 D after 1 month. One year postoperatively, mean SIA was -0.46 D. Between 1 and 5 years postoperatively, there was a statistically significant increase in mean SIA calculated by Cravy's vector analysis; SIA increased from -0.46 D after 1 year to -0.76 D after 5 years postoperatively. CONCLUSIONS: A small, although statistically significant, amount of postoperatively induced astigmatism occurred 5 years after a sutureless 5.0 mm sclerocorneal valve incision.

Aged↗

Phacotrabeculectomy with a small-optic PMMA implant: two-year functional and morphological results.

PURPOSE: Previous studies have documented good pressure control with combined cataract and filtering surgery. However, relatively high incidences of iridocapsular synechiae (ICS) and cell precipitates on the optic (CPO) were found. Corneal valve incisions preclude intraoperative chamber flattening and iris injury or prolapse. Rigid one-piece PMMA lenses with a small optic maintain a pronounced optic-iris clearance. In a prospective series, the effect of this approach was studied with special regard to the morphological results. METHODS: A temporary corneal lip was created in the clear cornea beneath the scleral flap to serve as a temporary valve during cataract extraction. The lip was then widened and a rigid one-piece 5-mm PMMA lens implanted. Lip and trabeculum were finally excised en bloc at a width of 3 mm. Two years' functional and morphological results were evaluated. RESULTS: Fifty-four eyes were available for evaluation. After the mean follow-up of 21 months, mean IOP had dropped from 21.6+/-3 mm Hg preoperatively to 13.9+/-2.4 mm Hg, with a mean pressure reduction of 7.7+/-3.4 mm Hg. IOP was 18 mm Hg or less in all cases. The mean medication index dropped from 2.7 to 1.0. Eyes with a preoperative IOP of 21 mm Hg or more showed a significantly greater IOP reduction than eyes with an IOP of 20 mm Hg or less (-9.2+/-3.0 vs. -6.1+/-2.9 mm Hg, p = 0.0003). Intraoperatively, the temporary valve effectively prevented chamber flattening and iris injury or prolapse. Postoperatively, 9 eyes or 6% showed hyphemas, 1 undergoing lavage. Two eyes developed a capsular hematoma, 1 requiring YAG capsulotomy. Ten eyes or 19% developed mild and 2 eyes severe but transient fibrin exudation following hypotony or iridoplasty. One eye showed grade I anterior chamber flattening, 1 developed a ciliolenticular block requiring surgery. Postoperative pressure spikes of 30-35 mm Hg were noted in 4 eyes. Three eyes showed prolonged hypotony associated with transient choroidal effusion. A pronounced optic-iris clearance was found in 87% of the eyes. Iris-optic touch developed in 1 eye with prolonged postoperative anterior chamber flattening and in 3 of the 4 eyes that had undergone intraoperative iridoplasty. Three of the latter developed extensive ICS followed by CPO. The mean optic-iris distance was 1.2 mm and the anterior chamber depth 4.2 mm. CONCLUSION: Apart from effectively lowering IOP, the surgical approach used significantly reduced the incidence of ICS and CPO.

Anterior Eye Segment↗

Radio-opaque markers for stereotactic imaging of uveal melanoma.

In in vitro and in vivo studies, episclerally sutured radio-opaque markers were evaluated as localizers for better determination of the clinical tumour volume prior to stereotactic radio-therapy of uveal melanoma. Four different types of markers were studied in vitro: tantalum marker, 2.5 mm in diameter; ring-shaped markers custom-designed in polymethyl methacrylate (PMMA), 2.6 mm and 3.0 mm in diameter; and barium-impregnated silicone rubber spheres, 2 mm in diameter. In vivo PMMA markers 3.0 mm in diameter and barium-impregnated silicone rubber spheres 2 mm in diameter were used. The best results were obtained with the barium-impregnated silicone rubber spheres both in vitro and in vivo. For the CT-delineation of selected uveal melanomas with either a flat discoid shape or flat tumour extensions or when adjacent serous retinal detachment is present, small episclerally sutured barium-impregnated silicone rubber spheres are useful as localizers for determining the clinical tumour volume.

Humans↗

Dose-dependent protection by azelastine eye drops against pollen-induced allergic conjunctivitis. A double-blind, placebo-controlled study.

The efficacy and tolerability of azelastine (CAS 58581-89-8) eye drops at three different doses (0.025%, 0.05% and 0.1%) were investigated in a double-blind, randomized, placebo-controlled, crossover study in 24 subjects with a history of allergic conjunctivitis/rhinoconjunctivitis, who were challenged, out of season, by airbone allergen in the "Vienna Challenge Chamber" (VCC). Subjects received a single dose of azelastine eye drops 60 min before the start of a 4 h challenge in the VCC. Additional local challenge, mimicking a gust of wind, was administered 15 min before the end of the session. Each of the 4 study days was separated by a 2 week washout period. Azelastine eye drops showed a dose-dependent inhibition of the development of itching of the eyes. The effect was most pronounced 15 min after the additional local challenge. A maximal effect was achieved at a dose of 0.05%. Similar effects were observed on lacrimation. Azelastine eye drops also dose-dependently inhibited the degree of conjunctival redness, measured by digital imaging, and tended to reduce the low incidence of chemosis observed. Ranking of the results of all symptoms for each treatment group confirmed the optimal effect at a dose of 0.05%. Azelastine eye drops had no effect on nasal and bronchial symptoms or on measurements of airways function (FEV1). No adverse effects of the treatments were reported. The data support the use of 0.05% azelastine eye drops in the treatment of allergic conjunctivitis/rhinoconjunctivitis.

Adult↗