Search PubMed⌕ Search

Biomedical subjects

R M Weisskoff

Publications and source records attributed to R M Weisskoff.

At least 73 records · Page 4Linked to original sources

MR contrast due to intravascular magnetic susceptibility perturbations.

A particularly powerful paradigm for functional MR imaging of microvascular hemodynamics incorporates paramagnetic materials that create significant image contrast. These include exogenous (lanthanide chelates) and endogenous (deoxygenated hemoglobin) agents for mapping cerebral blood volume and neuronal activity, respectively. Accurate interpretation of these maps requires an understanding of the biophysics of susceptibility-based image contrast. The authors developed a novel Monte Carlo model with which the authors quantified the relationship between microscopic tissue parameters, NMR imaging parameters, and susceptibility contrast in vivo. The authors found vascular permeability to water and the flow of erythrocytes to be relatively unimportant contributors to susceptibility-induced delta R2. However, pulse sequence, echo time, and concentration of contrast agent have profound effects on the vessel size dependence of delta R2. For a model vasculature containing both capillaries and venules, the authors predicted a linear volume fraction dependence for physiological volume changes based on recruitment and dilation, and a concentration dependence that is nonlinear and pulse sequence dependent. Using the model, the authors demonstrated that spin echo functional images have greater microvascular sensitivity than gradient echo images, and that the specifies of the volume fraction and concentration dependence of transverse relaxivity change should allow for robust mapping of relative blood volume. The authors also demonstrated excellent agreement between the predictions of their model and experimental data obtained from the serial injection of superparamagnetic contrast agent in a rat model.

Animals↗

Imaging myocardial fiber architecture in vivo with magnetic resonance.

Methods are presented to image the fiber architecture of the human myocardium in vitro and in vivo. NMR images are obtained of the diffusion anisotropy tensor, indicative of local myofiber orientation. Studies of cardiac necropsy specimens demonstrate classic features of ventricular myoarchitecture including the continuous endocardial to epicardial variation of fiber helix angles (angles to the ventricular circumferential direction) of approximately +1.3 to -1.3 radians. Cross-fiber anisotropy is also observed. In the beating heart, NMR diffusion data must be corrected for the effects of myocardial deformation during the cardiac cycle. This correction can be performed using an independent MRI method to map the strain-rate tensor field of the myocardium through time. Combining fiber orientation with local myocardial strain rate, local rates of myocardial fiber shortening may be computed.

Anisotropy↗

MR perfusion studies with T1-weighted echo planar imaging.

The T1 perfusion model has worked well in brain functional studies where flow changes are measured. Using selective and nonselective inversion pulses, a new method has been developed to study steady-state brain blood flow. The authors obtained flow-sensitive images using selective inversion and flow-insensitive images using nonselective inversion. Subtraction of flow-insensitive images from flow-sensitive images gave us flow-weighted images with good gray-white flow contrast in cortical gray matter as well as in the thalamus and basal ganglia. Fitting T1s of flow-insensitive and flow-sensitive images allowed us to obtain preliminary results of brain blood flow maps. Two specific problems can seriously affect the accuracy of the brain blood flow values and the gray-white flow contrast of brain blood flow maps. These are the problems of the partial volume effect of CSF and gray matter, and the difference between blood T1 and white matter T1. The authors discuss in detail the character of these problems and present a number of approaches to manage such problems.

Artifacts↗

Dynamic magnetic resonance imaging of vocal cord closure during deglutition.

BACKGROUND & AIMS: Vocal cord closure is instrumental in airway protection during deglutition. Conventional imaging of vocal cord closure and reopening during deglutition requires invasive and nonphysiological methods. The aim of this study was to characterize the biomechanical properties of normal vocal cord adduction/abduction during deglutition using echoplanar magnetic resonance imaging, a technique that has the capability of imaging soft-tissue motion with real-time temporal resolution. METHODS: The movements of laryngeal and vocal cord structures during swallowing were determined in 11 normal volunteers by single slice and axially reformatted multislice coronal echoplanar images. RESULTS: During swallowing, the larynx ascended to peak elevation, maintained peak elevation for a discrete interval, and descended to its resting position. Vocal cord adduction occurred with a symmetric tent-like configuration at the midpoint of maximal laryngeal elevation, whereas vocal cord abduction occurred at the midpoint of laryngeal descent. Spatial analysis of vocal cord configuration during adduction determined that the vocal cords attained an initial parallel configuration during ascent, followed by closure at peak laryngeal elevation. CONCLUSIONS: These results show that the vocal cords adduct and abduct synchronously with laryngeal ascent and descent, respectively, during deglutition. Echoplanar magnetic resonance imaging constitutes a novel tool used to assess clinical abnormalities of deglutitive laryngeal function.

Adult↗

Intramural mechanics in hypertrophic cardiomyopathy: functional mapping with strain-rate MR imaging.

PURPOSE: To characterize systolic and diastolic intramural mechanics in hypertrophic cardiomyopathy (HCM) with a new metric of contractile activity. MATERIALS AND METHODS: Eleven healthy subjects and eight patients with HCM underwent velocity-encoded echo-planar magnetic resonance (MR) imaging (6-8-frame gated breath-hold movies, 3 x 3-mm resolution). A scalar strain rate (SR) parameter was compared with wall thickness and symptoms. RESULTS: The normal pattern of SR included regional uniformity, a monotonically increasing subepicardial to subendocardial gradient, and minimum transmural shear rate. In HCM, heterogeneity of SRs increased in diastole. Regional diastolic SR correlated with regional wall thickness (r = .785, P = .0001). Interobserver global SR assignment agreed in seven of eight patients. All four patients with New York Heart Association class 1 disease had a low global SR deficit score, whereas three of four patients with class 2 or 3 disease had a high SR deficit score (Spearman r = .775, P = .187). CONCLUSION: SR characterization may provide an objective measure of disease course in HCM.

Adolescent↗

Benign and malignant breast lesions: differentiation with echo-planar MR imaging.

PURPOSE: To quantify dynamic enhancement of breast lesions with echo-planar and conventional magnetic resonance (MR) imaging, to correlate these data with histologic findings and vessel density, and to evaluate MATERIALS AND METHODS: Twenty female patients with 22 breast lesions underwent conventional and MR echo-planar imaging T1 values, change in gadopentetate dimeglumine concentration, and extraction-flow products were calculated with echo-planar imaging data and were correlated with histologic findings and microvessel density. RESULTS: T1 values of cancers were not statistically significantly shorter. Cancers had more rapid uptake and higher extraction-flow products (P < .02). Sensitivity was 86% and specificity was 93% for diagnosis of malignancy. Microvessel density was higher for malignant lesions (P < .02) with an overall positive (not statistically significant) correlation between extraction-flow product and microvessel density. CONCLUSION: Echo-planar imaging appears promising for quantification of breast lesion enhancement. Microvessel data indicate that tumor angiogenesis affects enhancement.

Adolescent↗

Functional MR of brain activity and perfusion in patients with chronic cortical stroke.

PURPOSE: (1) To determine whether functional MR can reliably map functional deficits in patients with stroke in the primary visual cortex; (2) to determine whether functional MR can reliably map perfusion deficits; and (3) to determine whether functional MR can give any additional diagnostic information beyond conventional MR. METHODS: Seven patients who had had a stroke in their primary visual system were examined using two functional MR techniques: (1) dynamic susceptibility contrast imaging, and (2) cortical activation mapping during full-field visual stimulation. Maps of relative cerebral blood volume and activation were created and compared with visual field examinations and conventional T2-weighted images on a quadrant-by-quadrant basis in five of these patients. RESULTS: Visual field mapping matched with both T2-weighted conventional images and activation mapping of 16 of 18 quadrants. In two quadrants, the activation maps detected abnormalities that were present on the visual field examination but not present on the T2-weighted images nor on the relative cerebral blood volume maps, which may indicate abnormal function without frank infarction. In addition, the activation maps demonstrated decreased activation in extrastriate cortex and had normal T2 signal and relative cerebral blood volume but was adjacent to infarcted primary cortex, mapping in vivo how stroke in one location can affect the function of distant tissue. CONCLUSION: Functional MR techniques can accurately map functional and perfusion deficits and thereby provide additional clinically useful information. Additional studies will be needed to determine the prognostic utility of functional MR in stroke patients.

Aged↗

Microscopic susceptibility variation and transverse relaxation: theory and experiment.

Microscopic susceptibility variations invariably increase apparent transverse relaxation rates. In this paper, we present comparisons between Monte Carlo simulations and experiments with polystyrene microspheres to demonstrate that this enhanced relaxation can be explained quantitatively for both spin echo and gradient echo imaging experiments. The spheres used (1 to 30 microms), and degree of susceptibility variation (caused by 0-12 mM Dy-DTPA) covered a wide range of biologically relevant compartment sizes and contrast agent concentrations. These results show that several regimes of behavior exist, and that contrast dependence is quite different in these regimes. For a given susceptibility, delta chi, a small range of particle sizes show peak transverse relaxation. For the range of susceptibilities found in the first pass of a clinical IV contrast agent bolus, this size range is 5 to 10 microns, or roughly capillary sized compartments. In both our simulations and experiments, smaller spheres showed quadratic relaxation versus concentration curves, and larger particles showed sublinear behavior. For particles corresponding to the peak relaxivity, the relaxation-concentration curves were linear. In addition, we demonstrated that increasing the diffusion coefficient can increase, decrease, or, paradoxically, leave unaffected the apparent relaxation rate. The regime for which the diffusion coefficient is relatively unimportant corresponds to the region of peak relaxivity. By using the Bloch-Torrey equation to produce scaling rules, the specific Monte Carlo simulations were extended to more general cases. We use these scaling rules to demonstrate why we often find that susceptibility-induced relaxation rates vary approximately linearly with concentration of injected agent.

Animals↗

MRI signal void due to in-plane motion is all-or-none.

The process of MRI signal attenuation due to in-plane intravoxel velocity inhomogeneity is described. Given rigid rotation or linear shear, velocity phase-sensitivity will induce a phase distribution that varies linearly with position, which is exactly equivalent to the effect of a spatial phase encoding gradient pulse. It follows that the effect of such motion on the raw MRI signal is to displace it a fixed distance in kappa-space. Attenuation becomes marked when the center of the spin-echo reaches an edge of kappa-space, which happens when intravoxel phase shifts reach pi radian/voxel. Because spin echoes are typically peaked sharply at center, this attenuation usually is abrupt. Analytic and numerical simulations of linear and nonlinear velocity fields confirm abrupt MRI attenuation where phase dispersion exceeds pi radian/voxel. Examples of this phenomenon include the abrupt loss of blood signal adjacent the vessel wall in laminar flow, abrupt loss of subendocardial signal in early diastole, and sudden disappearance due to rotation of a kidney during a measurement of diffusion.

Artifacts↗

Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings.

PURPOSE: To assess the utility of magnetic resonance (MR) cerebral blood volume (CBV) maps in the evaluation of gliomas. MATERIALS AND METHODS: CBV maps from 19 patients with histologically proved gliomas were calculated from dynamic MR image sets acquired with echo-planar spin-echo imaging after intravenous injection of gadolinium-based contrast material. RESULTS: The maximum CBV varied from 0.82 to 5.40 in the high-grade group (n = 13) and from 1.01 to 1.21 in the low-grade group (n = 6). The difference was statistically significant. Maximum CBV was associated with mitotic activity and vascularity, but not with cellular atypia, endothelial proliferation, necrosis, or cellularity. CONCLUSION: MR CBV maps provided diagnostic information not available with conventional MR imaging in six cases and offers a functional parameter for assessing glioma grade and regions of focal activity.

Adult↗

Pitfalls in MR measurement of tissue blood flow with intravascular tracers: which mean transit time?

Measuring tissue blood flow with NMR imaging of intravascular tracers is more difficult than measurements of tissue blood volume. One major obstacle to the application of the Central Volume Principle is the direct measurement of the mean transit time. In this note, we demonstrate that mean transit time (MTT), which relates tissue blood volume to blood flow via the Central Volume Principle, is not the first moment of the concentration-time curve for MR or CT imaging of purely intravascular tracers. However, while first moment methods cannot be used by themselves to determine absolute flow, we show that transit curves may provide a useful relative measure of flow, for example, by considering ratios of the first moments.

Blood Flow Velocity↗

Nonaxial whole-body instant imaging.

We demonstrate that whole-body, single-shot imaging is practical for imaging out of the central plane, including oblique axes. The technique is illustrated by images of the heart in the cardiac long- and short-axis and by coronal images of the brain. Secondary gradients can produce additional image distortion and ghosting in these images. These artifacts are a direct consequence, predictable by Maxwell's equations, of the large gradients used in echo planar imaging. We show that these effects are, in general, made smaller by working at a high magnetic field.

Artifacts↗

Time of flight quantification of coronary flow with echo-planar MRI.

Detection and quantification of flow of the left anterior descending (LAD) coronary artery in healthy volunteers are demonstrated using echo-planar imaging (EPI). A time-of-flight (TOF) model was used to derive coronary flow velocities from wash-in curves, free of cardiac wall motion contamination. Short-axis cardiac studies were performed using a gated, gradient echo EPI technique to limit the effect of cardiac wall motion on coronary vessel imaging. A series of 10 to 20 single or multislice images were acquired within a single breath-hold. Real-time cine series showed the LAD coronary artery with a detectability of 91% (n = 23) and revealed beat-to-beat variability in vessel position of a magnitude equal to or greater than its diameter. Flow velocity was measured in the proximal portion of the artery at rest and during exercise. The data demonstrated the known phasic pattern of LAD flow: Vsystole < or = 5 cm/s and peak Vdiastole = 14 +/- 3 cm/s (n = 11, V = mean laminar flow velocity). During isometric exercise, a LAD flow velocity increase (52 +/- 24%) was detected in eight of nine subjects. The capacity of the EPI TOF method to detect flow velocity changes should prove clinically useful for future assessment of coronary flow reserve.

Coronary Circulation↗

Measurement of regional blood oxygenation and cerebral hemodynamics.

An echo planar linewidth mapping technique, Shufflebutt, has allowed temporal measurements of changes in linewidth caused by static inhomogeneities (delta LWSI) and transverse relaxation rate (delta R2) in models of hypoxia and hypercapnia. We demonstrate these changes are due to intravascular susceptibility differences/(delta chi) between the blood and tissue. Contrast agent injections at a delta chi equivalent to that of deoxygenated blood showed a twofold difference between the contrast agent and physiological anoxia values. Hypercapnia decreased both delta LWSI and delta R2 consistent with an increase in blood oxygenation. We attribute these findings to constant oxygen extraction during an increase in blood flow, resulting in less deoxygenated venous blood and thus reduced delta chi. For in vivo perturbations we found that delta R2/delta R2' approximately 0.33, a ratio much different from that measured in whole blood phantoms (delta R2/delta R2' approximately 2). This demonstrates that signal changes in these studies are produced predominantly by dephasing of extravascular protons due to field inhomogeneities produced by intravascular deoxygenated hemoglobin (deoxyHb).

Animals↗

Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.

Neuronal activity causes local changes in cerebral blood flow, blood volume, and blood oxygenation. Magnetic resonance imaging (MRI) techniques sensitive to changes in cerebral blood flow and blood oxygenation were developed by high-speed echo planar imaging. These techniques were used to obtain completely noninvasive tomographic maps of human brain activity, by using visual and motor stimulus paradigms. Changes in blood oxygenation were detected by using a gradient echo (GE) imaging sequence sensitive to the paramagnetic state of deoxygenated hemoglobin. Blood flow changes were evaluated by a spin-echo inversion recovery (IR), tissue relaxation parameter T1-sensitive pulse sequence. A series of images were acquired continuously with the same imaging pulse sequence (either GE or IR) during task activation. Cine display of subtraction images (activated minus baseline) directly demonstrates activity-induced changes in brain MR signal observed at a temporal resolution of seconds. During 8-Hz patterned-flash photic stimulation, a significant increase in signal intensity (paired t test; P less than 0.001) of 1.8% +/- 0.8% (GE) and 1.8% +/- 0.9% (IR) was observed in the primary visual cortex (V1) of seven normal volunteers. The mean rise-time constant of the signal change was 4.4 +/- 2.2 s for the GE images and 8.9 +/- 2.8 s for the IR images. The stimulation frequency dependence of visual activation agrees with previous positron emission tomography observations, with the largest MR signal response occurring at 8 Hz. Similar signal changes were observed within the human primary motor cortex (M1) during a hand squeezing task and in animal models of increased blood flow by hypercapnia. By using intrinsic blood-tissue contrast, functional MRI opens a spatial-temporal window onto individual brain physiology.

Animals↗

MRI susceptometry: image-based measurement of absolute susceptibility of MR contrast agents and human blood.

We present a novel NMR imaging technique that allows absolute determination of the magnetic susceptibility constant, chi, of a solution. By comparing the phase difference of MR images produced with an instant (echo planar) "offset" spin-echo sequence, we obtain a direct measure of the magnetic field perturbations caused by the solution. We demonstrate this method with Gd(DTPA), Dy(DTPA), human red blood cells, and superparamagnetic iron oxide particles.

Contrast Media↗