Search PubMed⌕ Search

Biomedical subjects

R M Rangayyan

Publications and source records attributed to R M Rangayyan.

At least 19 recordsLinked to original sources

Analysis of asymmetry in mammograms via directional filtering with Gabor wavelets.

This paper presents a procedure for the analysis of left-right (bilateral) asymmetry in mammograms. The procedure is based upon the detection of linear directional components by using a multiresolution representation based upon Gabor wavelets. A particular wavelet scheme with two-dimensional Gabor filters as elementary functions with varying tuning frequency and orientation, specifically designed in order to reduce the redundancy in the wavelet-based representation, is applied to the given image. The filter responses for different scales and orientation are analyzed by using the Karhunen-Loève (KL) transform and Otsu's method of thresholding. The KL transform is applied to select the principal components of the filter responses, preserving only the most relevant directional elements appearing at all scales. The selected principal components, thresholded by using Otsu's method, are used to obtain the magnitude and phase of the directional components of the image. Rose diagrams computed from the phase images and statistical measures computed thereof are used for quantitative and qualitative analysis of the oriented patterns. A total of 80 images from 20 normal cases, 14 asymmetric cases, and six architectural distortion cases from the Mini-MIAS (Mammographic Image Analysis Society, London, U.K.) database were used to evaluate the scheme using the leave-one-out methodology. Average classification accuracy rates of up to 74.4% were achieved.

Breast Neoplasms↗

Detection of breast masses in mammograms by density slicing and texture flow-field analysis.

We propose a method for the detection of masses in mammographic images that employs Gaussian smoothing and sub-sampling operations as preprocessing steps. The mass portions are segmented by establishing intensity links from the central portions of masses into the surrounding areas. We introduce methods for analyzing oriented flow-like textural information in mammograms. Features based on flow orientation in adaptive ribbons of pixels across the margins of masses are proposed to classify the regions detected as true mass regions or false-positives (FPs). The methods yielded a mass versus normal tissue classification accuracy represented as an area (Az) of 0.87 under the receiver operating characteristics (ROCs) curve with a dataset of 56 images including 30 benign disease, 13 malignant disease, and 13 normal cases selected from the mini Mammographic Image Analysis Society database. A sensitivity of 81% was achieved at 2.2 FPs/image. Malignant tumor versus normal tissue classification resulted in a higher Az value of 0.9 under the ROC curve using only the 13 malignant and 13 normal cases with a sensitivity of 85% at 2.45 FPs/image. The mass detection algorithm could detect all the 13 malignant tumors successfully, but achieved a success rate of only 63% (19/30) in detecting the benign masses. The mass regions that were successfully segmented were further classified as benign or malignant disease by computing five texture features based on gray-level co-occurrence matrices (GCMs) and using the features in a logistic regression method. The features were computed using adaptive ribbons of pixels across the boundaries of the masses. Benign versus malignant classification using the GCM-based texture features resulted in Az = 0.79 with 19 benign and 13 malignant cases.

Algorithms↗

Auditory display of knee-joint vibration signals.

Sounds generated due to rubbing of knee-joint surfaces may lead to a potential tool for noninvasive assessment of articular cartilage degeneration. In the work reported in the present paper, an attempt is made to perform computer-assisted auscultation of knee joints by auditory display (AD) of vibration signals (also known as vibroarthrographic or VAG signals) emitted during active movement of the leg. Two types of AD methods are considered: audification and sonification. In audification, the VAG signals are scaled in time and frequency using a time-frequency distribution to facilitate aural analysis. In sonification, the instantaneous mean frequency and envelope of the VAG signals are derived and used to synthesize sounds that are expected to facilitate more accurate diagnosis than the original signals by improving their aural quality. Auditory classification experiments were performed by two orthopedic surgeons with 37 VAG signals including 19 normal and 18 abnormal cases. Sensitivity values (correct detection of abnormality) of 31%, 44%, and 83%, and overall classification accuracies of 53%, 40%, and 57% were obtained with the direct playback, audification, and sonification methods, respectively. The corresponding d' scores were estimated to be 1.10. -0.36, and 0.55. The high sensitivity of the sonification method indicates that the technique could lead to improved detection of knee-joint abnormalities; however, additional work is required to improve its specificity and achieve better overall performance.

Acoustics↗

Automatic de-noising of knee-joint vibration signals using adaptive time-frequency representations.

A novel de-noising method for improving the signal-to-noise ratio of knee-joint vibration signals (also known as vibro-arthrographic (VAG) signals) is proposed. The de-noising methods considered are based on signal decomposition techniques, such as wavelets, wavelet packets and the matching pursuit (MP) method. Performance evaluation with synthetic signals simulated with the characteristics expected of VAG signals indicates good de-noising results with the MP method. Statistical pattern classification of non-stationary signal features extracted from time-frequency distributions of 37 (19 normal and 18 abnormal) MP method-de-noised VAG signals shows a sensitivity of 83.3%, a specificity of 84.2% and an overall accuracy of 83.8%.

Algorithms↗

Boundary modelling and shape analysis methods for classification of mammographic masses.

The problem of computer-aided classification of benign and malignant breast masses using shape features is addressed. The aim of the study is to look at the exceptions in shapes of masses such as circumscribed malignant tumours and spiculated benign masses which are difficult to classify correctly using common shape analysis methods. The proposed methods of shape analysis treat the object's boundary in terms of local details. The boundaries of masses analysed using the proposed methods were manually drawn on mammographic images by an expert radiologist (JELD). A boundary segmentation method is used to separate major portions of the boundary and to label them as concave or convex segments. To analyse the shape information localised in each segment, features are computed through an iterative procedure for polygonal modelling of the mass boundaries. Features are based on the concavity fraction of a mass boundary and the degree of narrowness of spicules as characterised by a spiculation index. Two features comprising spiculation index (SI) and fractional concavity (fcc) developed in the present study when used in combination with the global shape feature of compactness resulted in a benign/malignant classification accuracy of 82%, with an area (Az) of 0.79 under the receiver operating characteristics (ROC) curve with a database of the boundaries of 28 benign masses and 26 malignant tumours. SI alone resulted in a classification accuracy of 80% with Az of 0.82. The combination of all the three features achieved 91% accuracy of circumscribed versus spiculated classification of masses based on shape.

Algorithms↗

Adaptive time-frequency analysis of knee joint vibroarthrographic signals for noninvasive screening of articular cartilage pathology.

Vibroarthrographic (VAG) signals emitted by human knee joints are nonstationary and multicomponent in nature; time-frequency distributions (TFD's) provide powerful means to analyze such signals. The objective of this paper is to construct adaptive TFD's of VAG signals suitable for feature extraction. An adaptive TFD was constructed by minimum cross-entropy optimization of the TFD obtained by the matching pursuit decomposition algorithm. Parameters of VAG signals such as energy, energy spread, frequency, and frequency spread were extracted from their adaptive TFD's. The parameters carry information about the combined TF dynamics of the signals. The mean and standard deviation of the parameters were computed, and each VAG signal was represented by a set of just six features. Statistical pattern classification experiments based on logistic regression analysis of the parameters showed an overall normal/abnormal screening accuracy of 68.9% with 90 VAG signals (51 normals and 39 abnormals), and a higher accuracy of 77.5% with a database of 71 signals with 51 normals and 20 abnormals of a specific type of patellofemoral disorder. The proposed method of VAG signal analysis is independent of joint angle and clinical information, and shows good potential for noninvasive diagnosis and monitoring of patellofemoral disorders such as chondromalacia patella.

Algorithms↗

Gradient and texture analysis for the classification of mammographic masses.

Computer-aided classification of benign and malignant masses on mammograms is attempted in this study by computing gradient-based and texture-based features. Features computed based on gray-level co-occurrence matrices (GCMs) are used to evaluate the effectiveness of textural information possessed by mass regions in comparison with the textural information present in mass margins. A method involving polygonal modeling of boundaries is proposed for the extraction of a ribbon of pixels across mass margins. Two gradient-based features are developed to estimate the sharpness of mass boundaries in the ribbons of pixels extracted from their margins. A total of 54 images (28 benign and 26 malignant) containing 39 images from the Mammographic Image Analysis Society (MIAS) database and 15 images from a local database are analyzed. The best benign versus malignant classification of 82.1%, with an area (Az) of 0.85 under the receiver operating characteristics (ROC) curve, was obtained with the images from the MIAS database by using GCM-based texture features computed from mass margins. The classification method used is based on posterior probabilities computed from Mahalanobis distances. The corresponding accuracy using jack-knife classification was observed to be 74.4%, with Az = 0.67. Gradient-based features achieved Az = 0.6 on the MIAS database and Az = 0.76 on the combined database. The corresponding values obtained using jack-knife classification were observed to be 0.52 and 0.73 for the MIAS and combined databases, respectively.

Breast Neoplasms↗

Adaptive filtering, modelling and classification of knee joint vibroarthrographic signals for non-invasive diagnosis of articular cartilage pathology.

Interpretation of vibrations or sound signals emitted from the patellofemoral joint during movement of the knee, also known as vibroarthrography (VAG), could lead to a safe, objective, and non-invasive clinical tool for early detection, localisation, and quantification of articular cartilage disorders. In this study with a reasonably large database of VAG signals of 90 human knee joints (51 normal and 39 abnormal), a new technique for adaptive segmentation based on the recursive least squares lattice (RLSL) algorithm was developed to segment the non-stationary VAG signals into locally-stationary components; the stationary components were then modelled autoregressively, using the Burg-Lattice method. Logistic classification of the primary VAG signals into normal and abnormal signals (with no restriction on the type of cartilage pathology) using only the AR coefficients as discriminant features provided an accuracy of 68.9% with the leave-one-out method. When the abnormal signals were restricted to chondromalacia patella only, the classification accuracy rate increased to 84.5%. The effects of muscle contraction interference (MCI) on VAG signals were analysed using signals from 53 subjects (32 normal and 21 abnormal), and it was found that adaptive filtering of the MCI from the primary VAG signals did not improve the classification accuracy rate. The results indicate that VAG is a potential diagnostic tool for screening for chondromalacia patella.

Adult↗

Parametric representation and screening of knee joint vibroarthrographic signals.

We have been investigating analysis of knee joint vibration or vibroarthrographic (VAG) signals as a potential tool for noninvasive diagnosis and monitoring of cartilage pathology. In this paper, we present a comprehensive comparative study of different parametric representations of VAG signals. Dominant poles and cepstral coefficients were derived from autoregressive models of adaptively segmented VAG signals. Signal features and a few clinical features were used as feature vectors in pattern classification experiments based on logistic regression analysis and the leave-one-out method. The results using 51 normal and 39 abnormal signals indicated the superior performance of cepstral coefficients in VAG signal classification with an accuracy rate of 75.6%. With 51 normal and 20 abnormal signals limited to chondromalacia patella, cepstral coefficients again gave the highest accuracy rate of 85.9%.

Algorithms↗

A segmentation-based lossless image coding method for high-resolution medical image compression.

Lossless compression techniques are essential in archival and communication of medical images. In this paper, a new segmentation-based lossless image coding (SLIC) method is proposed, which is based on a simple but efficient region growing procedure. The embedded region growing procedure produces an adaptive scanning pattern for the image with the help of a very-few-bits-needed discontinuity index map. Along with this scanning pattern, an error image data part with a very small dynamic range is generated. Both the error image data and the discontinuity index map data parts are then encoded by the Joint Bi-level Image experts Group (JBIG) method. The SLIC method resulted in, on the average, lossless compression to about 1.6 h/pixel from 8 b, and to about 2.9 h/pixel from 10 b with a database of ten high-resolution digitized chest and breast images. In comparison with direct coding by JBIG, Joint Photographic Experts Group (JPEG), hierarchical interpolation (HINT), and two-dimensional Burg Prediction plus Huffman error coding methods, the SLIC method performed better by 4% to 28% on the database used.

Algorithms↗

Measures of acutance and shape for classification of breast tumors.

Most benign breast tumors possess well-defined, sharp boundaries that delineate them from surrounding tissues, as opposed to malignant tumors. Computer techniques proposed to date for tumor analysis have concentrated on shape factors of tumor regions and texture measures. While shape measures based on contours of tumor regions can indicate differences in shape complexities between circumscribed and spiculated tumors, they are not designed to characterize the density variations across the boundary of a tumor. In this paper we propose a region-based measure of image edge profile acutance which characterizes the transition in density of a region of interest (ROI) along normals to the ROI at every boundary pixel. We investigate the potential of acutance in quantifying the sharpness of the boundaries of tumors, and propose its application to discriminate between benign and malignant mammographic tumors. In addition, we study the complementary use of various shape factors based upon the shape of the ROI, such as compactness, Fourier descriptors, moments, and chord-length statistics to distinguish between circumscribed and spiculated tumors. Thirty-nine images from the Mammographic Image Analysis Society (MIAS) database and an additional set of 15 local cases were selected for this study. The cases included 16 circumscribed benign, seven circumscribed malignant, 12 spiculated benign, and 19 spiculated malignant lesions. All diagnoses were proven by pathologic examinations of resected tissue. The contours of the lesions were first marked by an expert radiologist using X-Paint and X-Windows on a SUN-SPARCstation 2 Workstation. For computation of acutance, the ROI boundaries were iteratively approximated using a split/merge and end-point adjustment technique to obtain the best-fitting polygonal approximation. The jackknife method using the Mahalanobis distance measure in the BMDP (Biomedical Programs) package was used for classification of the lesions using acutance and the shape factors as features in various combinations. Acutance alone resulted in a benign/malignant classification accuracy of 95% the MIAS cases. Compactness alone gave a circumscribed/spiculated classification rate of 92.3% with the MIAS cases. Acutance in combination with a moment-based shape measure and a Fourier descriptor-based measure gave four-group classification rate of 95% with the MIAS cases. The results indicate the importance of including lesion edge definition with shape information for classification of tumors, and that the proposed measure of acutance fills this need.

Breast Neoplasms↗

Improvement of sensitivity of breast cancer diagnosis with adaptive neighborhood contrast enhancement of mammograms.

Mammograms are difficult to interpret, especially of cancers at their early stages. In this paper, we analyze the effectiveness of our adaptive neighborhood contrast enhancement (ANCE) technique in increasing the sensitivity of breast cancer diagnosis. Seventy-eight screen-film mammograms of 21 difficult cases (14 benign and seven malignant), 222 screen-film mammograms of 28 interval cancer patients and six benign control cases were digitized with a high-resolution of about 4096 x 2048 x 10-bit pixels and then processed with the ANCE method. Unprocessed and processed digitized mammograms as well as the original films were presented to six experienced radiologists for a receiver operating characteristic (ROC) evaluation for the difficult case set and to three reference radiologists for the interval cancer set. The results show that the radiologists' performance with the ANCE-processed images is the best among the three sets of images (original, digitized, and enhanced) in terms of area under the ROC curve and that diagnostic sensitivity is improved by the ANCE algorithm. All of the 19 interval cancer cases not detected with the original films of earlier mammographic examinations were diagnosed as malignant with the corresponding ANCE-processed versions, while only one of the six benign cases initially labeled correctly with the original mammograms was interpreted as malignant after enhancement. McNemar's tests of symmetry indicated that the diagnostic confidence for the interval cancer cases was improved by the ANCE procedure with a high level of statistical significance (p-values of 0.0001-0.005) and with no significant effect on the diagnosis of the benign control cases (p-values of 0.08-0.1). This study demonstrates the potential for improvement of diagnostic performance in early detection of breast cancer with digital image enhancement.

Breast Neoplasms↗

Screening of vibroarthrographic signals via adaptive segmentation and linear prediation modeling.

This paper proposes a noninvasive method to diagnose chondromalacia patella at its early stages by recording knee vibration signals (also known as vibroarthrographic or VAG signals) over the mid-patella during normal movement. An adaptive segmentation method was developed to segment the nonstationary VAG signals. The least squares modeling method was used to reduce the number of data samples to a few model parameters. Model parameters along with a few clinical parameters and a signal variability parameter were then used as discriminant features for screening VAG signals by applying logistic and discriminant algorithms. The system was trained using ten normal and eight abnormal signals. It correctly screened a separate test set of ten normal and eight abnormal signals except for one normal signal. The proposed method should find use as an alternative technique for diagnosis of knee joint pathology or as a test before arthroscopy or major knee surgery.

Algorithms↗

Normal and healing ligament vascularity: a quantitative histological assessment in the adult rabbit medial collateral ligament.

Normal and healing adult rabbit medial collateral ligaments (MCL) have been assessed for microvascular anatomy using a quantitative image analysis methodology. MCL preparation by ink-gelatin perfusion enabled acceptable visualisation of microvascular channels within the tissue. Fifteen adult rabbits were studied; 3 normal rabbits formed an external time-zero control group; 12 animals received a standardised gap injury to the right MCL. The ligament injury was permitted to heal for 3, 6, 17 or 40 wk (3 animals in each healing group). Results confirmed that the normal MCL is hypovascular (about 1.46% vascularity by area) and that microvascular channels are highly organised and oriented longitudinally deep within the tissue. Healing MCL scar becomes twice as vascular as normal ligament early on, but returns to near normal values by 40 wk. Microvascular channels appear less organised in scar than in contralateral controls, but remodel with time. The directional scatter and spatial extent of ligament microvascular channels is quantifiable in normal and healing tissues.

Animals↗

Relationships of the vibromyogram to the surface electromyogram of the human rectus femoris muscle during voluntary isometric contraction.

The relationship between vibromyographic (VMG) and electromyographic (EMG) signals during isometric contraction of the human rectus femoris muscles was studied. The method of least squares was used to obtain the best-fitting linear regression model to the root mean squared (RMS) values of the VMG and the EMG. It is shown that for the rectus femoris of four subjects, a linear VMG versus EMG relationship exists during 20-80% of the maximum voluntary contraction (MVC) at 30 degrees, 60 degrees, and 90 degrees of knee joint flexion angles. The relation between the VMG and the EMG may be explained by the order recruitment of motor units and by the "onion-skin" phenomenon of the firing rates of recruited motor units in the regulation of muscle force production as reported in electro-neurophysiologic studies.

Adult↗

Localization of knee joint cartilage pathology by multichannel vibroarthrography.

This paper proposes non-invasive techniques to localize sound or vibroarthrographic (VAG) signal sources in human knee joints. VAG signals from normal subjects, patients who subsequently underwent arthroscopy, and cadavers with arthroscopically-created lesions, obtained by stimulation with a finger tap over the mid-patella and swinging movement of the leg, were analyzed for time delays using cross-correlation functions for source localization. Correct results were obtained for 13 of the 14 subjects tested by finger stimulation, and for 11 of the 12 subjects whose VAG signals during swinging movement were analyzed. The techniques could be valuable in the diagnosis and treatment of knee pathology before and after joint surgery or drug therapy.

Arthroscopy↗

Adaptive cancellation of muscle contraction interference in vibroarthrographic signals.

Vibroarthrography (VAG) is an innovative, objective, non-invasive technique for obtaining diagnostic information concerning the articular cartilage of a joint. Knee VAG signals can be detected using a contact sensor over the skin surface of the knee joint during knee movement such as flexion and/or extension. These measured signals, however, contain significant interference caused by muscle contraction that is required for knee movement. Quality improvement of VAG signals is an important subject, and crucial in computer-aided diagnosis of cartilage pathology. While simple frequency domain high-pass (or band-pass) filtering could be used for minimizing muscle contraction interference (MCI), it could eliminate possible overlapping spectral components of the VAG signals. In this work, an adaptive MCI cancellation technique is presented as an alternative technique for filtering VAG signals. Methods of measuring the VAG and reference signals (MCI) are described, with details on MCI identification, characterization, and step size optimization for the adaptive filter. The performance of the method is evaluated by simulated signals as well as signals obtained from human subjects under isotonic contraction.

Adult↗

Quantitative analysis of the fine vascular anatomy of articular ligaments.

An image analysis technique has been developed to quantitatively describe the fine vascular patterns observed in ligament tissue. The longitudinal orientational distribution and total vessel volume of India-ink-perfused blood vessel segments in normal and healing ligaments were determined. The methods involved special vascular preparation of adult rabbit knee medial collateral ligaments (MCL) by India-ink perfusion. Black and white microscope images of ink-perfused tissue sections were subjected to a thresholding procedure to binarize digitized ligament images, which were then skeletonized and analyzed for directional distribution based on the least-squares technique. Analysis of medial collateral ligaments in New Zealand White rabbits using this method has shown that scarred tissue is more vascular and has a more chaotic angular distribution of blood-vessel segments than normal ligament tissue.

Algorithms↗