Fracture toughness of dental composites determined using the short-rod fracture toughness test.

Plane strain fracture toughness (KIC) has been evaluated for a number of commercially-available dental composites. A modified Short-rod Fracture Toughness (SRFT) specimen design has been used, enabling small specimens to be tested conveniently. The effect on KIC of aging in water at 37 degrees C for seven days, one month, and six months has been determined for conventional, microfilled, and hybrid (coarse and fine filler particle-containing) composites. Our results suggest that aging for one month or more caused a reduction of KIC for the composites so aged. Comparison of the KIC values determined using the modified SRFT specimen with values obtained using more conventional specimen geometries gave good agreement, thereby suggesting the suitability of the small SRFT specimens for valid KIC determinations.

Composite Resins↗

Observations on the effect of movement on bone ingrowth into porous-surfaced implants.

Although porous-surfaced orthopedic implants have been designed for fixation by bone ingrowth, there is clinical evidence that this does not always occur. Initial implant movement relative to host bone can result in attachment by a nonmineralized fibrous connective tissue layer. The ranges of movement that result in either bone or fibrous connective tissue fixation are observed in dogs in two independent studies. Experimentally, bone ingrowth can occur in the presence of some movement, albeit very small (up to 28 mu), while excess movement (150 mu or more) can result in attachment by mature connective tissue ingrowth.

Animals↗

Oscillatory wear tests of dental composites.

The wear behavior of 12 commercial restorative composites (conventional and microfilled) and an unfilled restorative material was evaluated using an in vitro wear test referred to as an oscillatory wear test. The effect of varying test conditions was evaluated in a series of preliminary experiments in order to define test conditions for material evaluation. The materials were tested after being aged in water at 37 degrees C for periods of from seven days to one year. The results indicated consistently lower wear rates for the microfilled materials as compared with those of the conventional composites. Aging did not result in significant differences in wear rates measured by this method. Scanning electron micrography of worn surfaces suggested a possible effect of filler particle shape and bonding to the matrix to explain this difference. Although the relevance of the results to clinical behavior is not yet known, the study indicated the importance of material variables on wear.

Acrylic Resins↗

Powder metal-made orthopedic implants with porous surface for fixation by tissue ingrowth.

Powder metal-made orthopedic implants with a porous coating provide an effective means for implant fixation by tissue ingrowth. Additionally, the use of metal alloy powders for forming porous surfaces offers the advantage of uniform coatings on complex part shapes. With proper processing, implants with strong, porous surface layers and good substrate mechanical properties can be formed. The in vivo tests have demonstrated the need for initial implant stability to achieve bony ingrowth. Animal studies indicate an optimum pore size range of 50-400 mu, and human hip prostheses with pores in this range appear to function well. A porous surface integrated with a compatible implant design avoids undesirable bone remodeling with these types of implants.

Animals↗

Phase identification and incipient melting in a cast Co--Cr surgical implant alloy.

Phase relationships in cast Co--Cr surgical implant alloys, heat treated at temperatures from 1180 to 1300 degrees C, are reported. Interdendritic material was identified by selected area diffraction as a quaternary near eutectic mixture between sigma phase, M23C6, M7C3, and fcc Co. Incipient melting and subsequent resolidification of this near-eutectic mixture accounts for observations of behavior at temperatures above 1235 degrees C. At temperatures just below its melting point the interdendritic material initially breaks down to M23C6, which subsequently dissolves in the Co matrix.

Chemical Phenomena↗

Effect of pore size on the peel strength of attachment of fibrous tissue to porous-surfaced implants.

Twenty-four rectangular metal plates were fabricated with surface regions in three different pore size ranges (5-20 microns, 20-50 microns, 50-200 microns). The plates were implanted into the dorsal subcutaneous tissue of 12 adult mongrel dogs for periods of 4, 8, 12, and 16 weeks. After animal sacrifice, the fibrous tissue which adhered to the porous-surfaced regions of each plate was mechanically peeled off to give an indication of the strength of tissue attachment. The tissue was examined by both transmitted light and scanning electron microscopy. At each time period, the tissue that contacted the porous regions was found to be collagenized fibroconnective tissue. The mechanical tests indicated an increasing strength of tissue attachment with increasing implantation time and pore size range. The largest pore size range of approximately 50-200 microns produced a mean peel strength of attachment of 27.5 g/mm at the 16-week period.

Animals↗

Biologic fixation and bone modeling with an unconstrained canine total knee prosthesis.

To study the effects of dynamic loading on biologic fixation, an unconstrained type of prosthesis was designed for total replacement of the knee joint of dogs. The femoral component was fabricated from cast cobalt-based surgical alloy. The tibial component was fabricated from surgical grade, ultra-high molecular weight, high density polyethylene. Both components were designed for initial stabilization at surgery by mechanical interlock with bone. In addition, the bone-interfacing surface of the metal component was made porous and the stem of the polymer component was grooved to permit the subsequent ingrowth of tissue. Knee arthroplasty was performed on a total of six beagles. The prostheses were monitored for periods of 20 months and demonstrated an overall excellent stability and functionality. Each tibial component became stabilized by the formation of a thin, surrounding shell of osseous tissue. Interposed between this bone and the implant was usually a thin layer of fibrous tissue, suggesting micromovement during loading. Each femoral component became solidly fixed by bone growth into the porous surface. The altered stress state in the region of the implant eventually resulted in reactive bone modeling, with both bone formation and resorption occurring along the length of the implant.

Animals↗

A study of bone remodeling using metal-polymer laminates.

Bone remodeling due to stress-shielding has been studied using a model system consisting of metal-polymer laminated fixation plates securely fixed to canine femurs. The plate stiffness was controlled by varying the ratio of metal facing to polymer core thickness in the laminate design while secure fixation to bone was achieved by providing a porous bone interfacing surface for the ingrowth of bone from the periosteal surface. Observations of laterally and medially placed plates indicated resorption in the area of the periosteal and endosteal bone surfaces respectively, for the higher stiffness composite plates used. The results indicate that plate stiffness greater than approximately 70 GPa (axial) and 6 N m2 (flexural) will result in extensive bone remodeling in the canine femur after a six month implantation period.

Alloys↗

Osteogenic phenomena across endosteal bone-implant spaces with porous surfaced intramedullary implants.

Porous surfaced femoral components of hip prostheses stabilized by tissue ingrowth are often situated a certain distance away from the endosteal cortex in the diaphysis. The purpose of this study was to examine the significance of this space between an implant and the cortex on bone growth into the porous surface of the implant. Intramedullary rods of different diameters with porous surface regions made of powder metal were inserted into the femurs of adult beagles. The rods had outside diameters of 2.5, 3.2, 4.5, and 5.5 millimeters; this variation produced endosteal bone-implant surface spaces ranging from 0 to 4 millimeters. The animals were sacrificed at 4, 8, 12, and 16 weeks. Histological sections revealed that by 12 weeks the implants became generally surrounded by a thin shell of spongy bone which was joined to the endosteal cortex by bony trabeculae. This feature was most prominent for implants which were approximately 2 millimeters or less from the endosteum. Denser, more haversian-like bone developed up to and within those areas of implants which were in contact with the cortex. The development of this intramedullary type of bone could significantly contribute to the fixation strength of clinical porous surfaced prostheses whose stems do not completely fill the medulla.

Alloys↗

Radiographic and morphologic studies of load-bearing porous-surfaced structured implants.

Load-bearing porous-surfaced implants in dogs which failed were not incorporated by bone ingrowth. The implants were incorporated only by fibrous tissue ingrowth. Collagen fiber orientation within this fibrous tissue and Sharpey's fiber-like features at the interface between the fibrous tissue and a surrounding layer of dense bone suggest the adequacy of the fibrous tissue attachment for support of a loaded implant. The surrounding dense bone layer could be distinguished radiographically within three months of the operation. This radiopaque line is similar to that observed around some porous surfaced hip implants in humans. Observations of animal mobility up to six months postoperatively suggest that fibrous connective tissue growth into porous implants can provide adequate mechanical support for weight-bearing dogs.

Animals↗

Micromechanical bonding at a porous surface structured implant interface-the effect on implant stressing.

An experimental determination of the strains acting on femoral components of hip implants embedded in bone cement was made for the case of (a) porous surface coated and (b) conventional uncoated implants. The result indicated much lower tensile strains and stresses on the lateral surface of the porous coated implants. This was explained by micromechanical implant-cement bonding for the porous coated implant and a more effective transfer of stress from the implant to the cement for this design. The study suggests greater confidence against implant fatigue failure for the porous coated stems because of the lower strains and stresses acting on the implant.

Bone Cements↗

The effect of porous surface configuration on the tensile strength of fixation of implants by bone ingrowth.

In an attempt to gain information that could be directly applied to the design of clinical porous-surfaced prostheses intended for biological attachment by bone ingrowth, the tensile strength of the bone-implant interface was expressed as a function of 2 fundamentally different porous-surface configurations. Using powder metallurgy techniques, standard 3-hole fracture fixation plates were prepared with both a single and a multiple layer of spherically shaped metal powder particles on the bone-contacting surface to produce implants with different porous surfaces. These plates were implanted onto the lateral aspect of canine femurs for periods of 4, 6, 8, 12, 18, and 24 weeks. Mechanical tests were performed to measure the tensile strength of fixation of the implants by the ingrowth of bone. The results of the mechanical tests indicated that implants with the multiple particle layer surfce configuration develop a greater tensile strength of fixation than do implants with the single particle layer surface configuration. In addition, this fixation strength develops more quickly if the cortical bone is petaled prior to implantation. These findings should be considered when designing porous-surfaced implants intended for fixation by bone ingrowth.

Animals↗

Bone ingrowth and stress shielding with a porous surface coated fracture fixation plate.

The extent of bone remodelling under metal fixation plates attached to bone by (i) normal screw fixation and (ii) bone ingrowth into a porous metallic surface underlayer sintered to the metal plate was investigated. Extensive bone remodelling was observed under the integrally bonded porous surface layered plate. This remodelling could be attributed to the more extensive stress transfer from bone to metal plate because of the good bone-to-implant bonding. The importance of stress shielding with high stiffness implants is demonstrated.

Alloys↗

The porous-surfaced electrode: a new concept in pacemaker lead design.

Three major problems which may be encountered with endocardial pacemaker electrodes are a lack of stable position, a chronic increase in stimulation threshold, and a diminishing magnitude of the sensed endocardial signal. These problems are particularly manifest in the atrium. Having previously shown that porous metal surfaces can support stable tissue ingrowth in both bloodstream and soft tissue environments, we set out todetermine the performance of porous-surfaced endocardial pacing electrodes in the atrial position. In two groups of six dogs each, J-shaped atrial leads with Elgiloy electrode tips (2.3 mm. in diameter, 2.3 mm. in length), having either conventional smooth surfaces (control) or porous surfaces (20 to 50 micron particle size) produced by powder metallurgy techniques, were positioned in the right atrial a-pendage. Stimulation thresholds and P-wave amplitude were repeatedly measured until the dogs were put to death 30 w-eks following implantation. The presence or absence of electrode fixation was observed and the atrial tissue reaction was examined grossly and by both light and scanning electron microscopy (SEM). The porous-surfaced electrodes demonstrated superior long-term stimulation thresholds which, at 30 weeks, averaged less then one third of those in the control group. In addition, the porous group showed a small but significant improvement in the amplitude of the sensed P wave. None of the smooth-surfaced electrodes showed fixation, and the tissue reaction consisted of a thick layer of granulation and fibrous tissue on the underlying endocardium, widely separating the electrode from the myocardium. In contrast, all of the porous-surfaced electrodes were fexed to the endocardium by fibrous tissue ingrowth into the surface pores. This tissue fixation of the electrode tip in close proximity to underlying myocytes explains their superior performance.

Animals↗

A porous metal system for joint replacement surgery.

A porous coated chrome cobalt system has been developed to provide long term stabilization in joint replacement surgery. The pore sizes are 50 to 100 microns, thus ensuring sufficient fatigue strength for use in high load bearing situations. Extensive in vitro and in vivo studies have been performed, and a five year follow-up of porous coated total shoulder prostheses has failed to reveal any evidence of loosening. The early results of porous coated hip implants is encouraging.

Animals↗

Evaluation of biodegradable ceramic.

An evaluation of a porous biodegradable ceramic, tricalcium phosphate, has been carried out. When implanted in cancellous bone, it is rapidly infiltrated with bone and slowly resorbed. When held rigidly against raw, bleeding, cortical bone, again rapid bone ingrowth occurs. The material does not give rise to any untoward tissue reaction, nor does it cause any systemic reaction. It can therefore be concluded that the material is safe for use in clinical practice, and can be used in specific instances either to replace or to supplement bone grafting.

Animals↗