Search PubMed⌕ Search

Biomedical subjects

R M Heethaar

Publications and source records attributed to R M Heethaar.

At least 55 records · Page 3Linked to original sources

The influence of extravascular lung water on cardiac output measurements using thoracic impedance cardiography.

The purpose of this study was to investigate the influence of pulmonary oedema as measured with the double indicator dilution technique on the accuracy of cardiac output (CO) measurement using thoracic impedance cardiography (TIC) compared with thermodilution in thirteen sepsis patients. Differences in the Kubicek and Sramek-Bernstein equation with respect to pulmonary oedema were explored theoretically and experimentally. From a parallel two cylinder model a hypothesis can be derived that CO determined with the Kubicek equation is oedema independent, whereas CO determined using the Sramek-Bernstein equation is oedema dependent. Experimentally, CO determined using Kubicek's equation correlated better with thermodilution CO (r = 0.75) than CO determined with the Sramek-Bernstein equation (r = 0.25). The effect of oedema on the accuracy of TIC was investigated by comparing the differences in the CO of impedance and thermodilution to the extravascular lung water index. For the Kubicek equation the difference was not influenced by oedema (r = 0.04, p = 0.84), whereas for the Sramek-Bernstein equation the difference was affected by oedema (r = 0.39, p = 0.05). Thus, the effects of pulmonary oedema on the accuracy of TIC measurements can better be understood with the parallel cylinder model. Moreover, the Kubicek equation still holds when pulmonary oedema is present, in contrast to the Sramek-Bernstein equation.

Adult↗

Extra-cellular volume estimation by electrical impedance--phase measurement or curve fitting: a comparative study.

In order to determine body fluid shifts between the intra- and extra-cellular spaces, multifrequency impedance measurement is performed. According to the Cole-Cole extrapolation, lumped values of intra- and extra-cellular conduction can be estimated which are commonly expressed in resistances Ri and Re respectively. For this purpose the magnitude and phase of the impedance under study are determined at a number of frequencies in the range between 5 kHz and 1 MHz. An approach to determine intra- and extra-cellular conduction on the basis of Bode analysis is presented in this article. On this basis, estimation of the ratio between intra- and extra-cellular conduction could be performed by phase measurement only, midrange in the bandwidth of interest. An important feature is that the relation between intra- and extra-cellular conduction can be continuously monitored by phase measurement and no curve fitting whatsoever is required. Based on a two frequency measurement determining Re at 4 kHz and phi(max) at 64 kHz it proved possible to estimate extra-cellular volume (ECV) more accurately compared with the estimation based on extrapolation according to the Cole-Cole model in 26 patients. Reference values of ECV were determined by sodium bromide. The results show a correlation of 0.90 with the reference method. The average error of ECV estimation was -3.6% (SD 8.4), whereas the Cole-Cole extrapolation showed an error of 13.2% (SD 9.5). An important feature of the proposed approach is that the relation between intra- and extra-cellular conduction can be continuously monitored by phase measurement and no curve fitting whatsoever is required.

Electric Impedance↗

Myocardial function in infarcted and remote regions early after infarction in man: assessment by magnetic resonance tagging and strain analysis.

Early after infarction in the perfusion bed of the left anterior descending coronary artery, cine MRI with spatial modulation of magnetization (SPAMM) tagging (7-mm grid) was used for short- and long-axis cardiac imaging. Two-dimensional strain analysis of triangular finite elements was performed between end-diastole and end-systole. Patients (n = 10) were compared with age-matched healthy subjects (n = 8). The anteroseptal region at midventricular level was considered representative for "infarcted" and the posterolateral region at basal level was considered "remote". The left ventricular end-diastolic volume index was larger in the patients (69 +/- 15 ml/m2 versus 56 +/- 4 ml/m2, P < 0.05). Short-axis images showed in the infarcted region a decrease of first principal strain (greatest systolic lengthening: 1.10 +/- .06 versus 1.27 +/- 0.04, P < 0.0001), and in the remote region an increase (1.48 +/- 0.11 versus 1.36 +/- 0.07, P < 0.025). The lateral and inferior ventricular regions at mid- and basal levels were found to function normally. Long-axis images yielded similar results. Early after infarction, regions with dysfunction, normal function, and hyperfunction can be delineated with MR tagging. The compensatory increased contraction in the remote region is possibly triggered by the Frank-Starling mechanism.

Case-Control Studies↗

Validity and reproducibility of electrical impedance tomography for measurement of calf blood flow in healthy subjects.

The Sheffield electrical impedance tomography; (EIT) system produces images of changes in the distribution of resistivity within tissue. The paper reports on the application of electrical impedance tomography in monitoring volume changes in the limb during venous occlusion. The aim of the study is to assess the feasibility, reproducibility and validity of calf blood flow measurements by EIT. In 14 healthy volunteers calf blood flow is compared, as determined in a calf segment by strain-gauge plethysmography (SGP), with the impedance changes measured by EIT during rest and post-ischaemic hyperaemia. The measurements are repeated to assess reproducibility. The reproducibility for the EIT, assessed from the repeated measurements and expressed as a reproducibility coefficient, is 0.88 during rest and 0.89 during hyperaemia. The reproducibility coefficient for SGP data is 0.83 at rest and 0.67 during hyperaemia. Flow measurements, assessed by means of two methods, correlate well at rest (r = 0.89), but only moderately during hyperaemia (r = 0.51). The correlation coefficient for the pooled flow measurements is 0.98. It is concluded that EIT is a valid and reliable method for assessing blood flow in the limb. Possible applications of EIT in localising fluid changes are discussed.

Adult↗

The mechanism of red cell (dis)aggregation investigated by means of direct cell manipulation using multiple optical trapping.

We used multiple optical trapping to study the mechanism of red cell (dis)aggregation. Two sets of optical 'tweezers' were used to bring two red blood cells together to form a two-cell aggregate and then to pull them apart, to study the interaction between the cells. We found that cross-bridging occurred in normal reversible aggregation as we observed binding and the occurrence of small tethers between opposite cell membranes. Furthermore, the cells could only be parted by sliding them side by side with a maximum velocity in the order of microm/s indicating accumulation of the cross-bridges.

Cell Aggregation↗

The inaccuracy of Kubicek's one-cylinder model in thoracic impedance cardiography.

The validity of a one- and a two-cylinder model, underlying thoracic impedance cardiography (TIC), was investigated by studying the length dependence of the impedance parameters Z0, (dZ/dt)min, and stroke volume (SV). It can be shown that, within a one-cylinder model, all parameters are directly proportional to the length, whereas, if the volume conduction of the thorax and the neck are modeled separately, Z0 and (dZ/dt)min are expected to be linear dependent and SV will be nonlinear upon the length. The expectations were compared to results from in vivo measurements. Two electrode arrays were studied, in which the caudal recording electrode position was varied; SV was calculated using Kubicek's equation. Except for small distances, the results showed a nearly linear relation between the parameters and the length. Regression analysis of the linear part revealed statistically significant intercepts (p < 0.05). Neither the intercept nor the nonlinear part can be explained by a one-cylinder model, whereas a model consisting of two cylinders serially connected describes the experimental results accurately. Thus SV estimation based on a one-cylinder model is biased due to the invalid one-cylinder model. Corrections for the Kubicek-equation need to be developed in future research using this two-cylinder model.

Adult↗

A longitudinal study of maternal hemodynamics during normal pregnancy.

OBJECTIVE: To investigate the maternal hemodynamic changes that occur during normal pregnancy. METHODS: Serial hemodynamic investigations were performed throughout normal pregnancy by thoracic electrical bioimpedance monitoring in 50 healthy women. Analysis of variance with repeated measurements was used to evaluate the time course of a number of hemodynamic indies. RESULTS: The mean heart rate (+/- standard error [SE]) increased gradually from 87 +/- 2 beats per minute at 10-18 weeks' gestation to 92 +/- 1 beats per minute at 34-42 weeks' gestation. Mean arterial pressure decreased significantly after 14 weeks' gestation and increased significantly after 29 weeks' gestation. During the third trimester, mean cardiac output and mean stroke volume decreased, and mean systemic vascular resistance increased significantly. The course of cardiac output during the third trimester was not uniform in all women; it increased in nine and decreased in 41 women. A significantly higher mean cardiac output was found in nulliparous women compared with multiparous women (mean difference +/- SE 0.76 +/- 0.33 L/minute). The mean (+/- SE) cardiac output increased significantly from 6 (5.49 +/- 0.16 L/minute) to 12 weeks' postpartum (5.91 +/- 0.19 L/minute). CONCLUSION: Mean cardiac output and mean stroke volume decreased in late pregnancy. A significant difference in mean cardiac output was observed between nulliparous and multiparous women. Cardiac output usually, but not invariably, declined during the third trimester.

Adult↗

Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configuration.

Until now, electrical impedance tomography (EIT) has been used for cardiac imaging with the electrodes attached transversally at the level of the fourth intercostal space at the anterior side. However, the results obtained with this electrode configuration have been disappointing. The aim of the present study was to improve the measurement design of EIT for cardiac imaging. Therefore, magnetic resonance imaging (MRI) scans were analysed in two healthy subjects to determine the optimum anatomical plane in which atria and ventricles are clearly visually separated. From these findings, we proposed a new oblique plane at the level of the ictus cordis anteriorly and 10 cm higher posteriorly. EIT pictures obtained in the oblique plane revealed a better visual separation between the ventricles and atria than with the electrodes attached in the transverse plane. Comparison between volume changes measured by means of MRI and impedance changes in different regions of interest measured with EIT were performed with the electrodes in the proposed oblique plane. Ventricular and atrial volume changes measured by MRI show the same pattern as do impedance changes measured by EIT. Furthermore, we assessed the reproducibility and validity of the oblique electrode configuration in ten healthy mate volunteers during rest and during exercise compared with the currently used transverse electrode configuration. The reproducibility coefficient assessed from repeated measurements with the electrodes attached in the oblique plane was 0.98 at rest and 0.85 during exercise. For the transverse plane the reproducibility coefficient was 0.96 at rest and 0.66 during exercise. The well-known increase in stroke volume during exercise is 40% in healthy subjects. The increase in impedance change during exercise compared with rest was 34 +/- 13% (20-59%) for the oblique plane and 68 +/- 57% (13-140%) for the transverse plane. From these results we infer that the stroke volume is assessed more accurately by using the oblique plane. From these findings, we conclude that the oblique plane improved the cardiac measurements, because (i) a better spatial separation of the heart compartments is obtained, (ii) the results are more reliable and (iii) measurements during exercise are more accurate with the electrodes attached in an oblique plane.

Cardiography, Impedance↗

Thoracic electrical bioimpedance: suitable for monitoring stroke volume during pregnancy?

To obtain normal values for maternal stroke volume and cardiac output during pregnancy, a non-invasive, accurate and reproducible method is required. The thoracic electrical bioimpedance (TEB) method may be suitable. However, this method is as yet only qualified for short-term trend recordings, since it assumes that body dimensions such as height, weight and thoracic circumference remain constant during the study. This may not be the case in long-term studies, especially during pregnancy. In this paper it is argued that changes in stroke volume (SV) during pregnancy are reflected most strongly when using the formula: SV = P VET (dZ/dt)max/Z0, where P is a personal factor to be determined at the beginning of pregnancy; VET the ventricular ejection time; (dZ/dt)max the maximum of the first derivative of the thoracic impedance during the cardiac cycle and Z0 the time average of this impedance during the cardiac cycle. Indexed parameters should not be used as this reduces sensitivity. Commercial equipment, based upon other algorithms, can be used by feeding the right parameters for each series of measurements. This enables calculation, trends in stroke volume and cardiac output for longitudinal studies for instance during pregnancy.

Algorithms↗

Monitoring intracranial dynamics by transcranial Doppler--a new Doppler index: trans systolic time.

Since the introduction of transcranial Doppler sonography (TCD) several investigators have described the relationship between raised intracranial pressure (ICP) and Doppler waveform. This waveform has been expressed by several indices, such as the pulsatility index (PI) and the resistance index (RI). These indices are used to demonstrate the presence of raised ICP. In childhood hydrocephalus this information can be used to indicate the need for shunt implantation. However, PI and RI do prove to have certain disadvantages as both are strongly influenced by the heart rate. Moreover, both indices have a broad range of reference values, especially in children. Therefore, they are not very reliable for detecting insidious changes in the ICP. These drawbacks are due to the fact that these indices are composed of blood flow velocity measurements and do not embody the slope of the TCD waveform itself. An ideal TCD waveform analysis should be performed concerning the time-related changes of the velocities. We present a hydrodynamic model, with its electrical analogue, which shows the effects of raised ICP on the intracranial hemodynamic system. Based on these physical findings we define a new Doppler index, the Trans Systolic Time, reflecting specific changes in the TCD waveform induced by changes in the mean ICP. The applicability of this index, compared with PI and RI, is illustrated by consecutive simultaneous TCD and AFP measurements in three children with hydrocephalus.

Blood Flow Velocity↗

Lateral migration of blood cells and microspheres in two-dimensional Poiseuille flow: a laser-Doppler study.

The inertia-induced lateral migration of rigid microspheres, platelets and erythrocytes is studied experimentally. The concentration and velocity profiles of the particles have been determined with a laser-Doppler anemometer designed for high resolution measurements. Data are compared with empirical and analytical models on inertia-induced lateral migration of rigid spheres. Experiments done in rectangular flow channels of high aspect ratio reveal that at a sufficiently high particle Reynolds number, platelets exhibit tubular pinch effects comparable with those of rigid polystyrene microspheres. Erythrocytes also exhibit inertia-induced lateral migration at high particle Reynolds number and low medium viscosity. At a higher medium viscosity, erythrocytes show deformation-induced lateral migration towards the center of the flow channel.

Blood Flow Velocity↗

Near-wall excess of platelets induced by lateral migration of erythrocytes in flowing blood.

In this study we present experimental data on the inhomogeneous distribution of platelets in polyethylene tubes (200 microns diam) based on the inverse Fåhraeus effect for platelets. It is shown that platelets are expelled toward the red blood cell-depleted marginal layer near the tube wall by mutual interaction with erythrocytes. By means of a straightforward model, the near-wall concentration of platelets could be estimated from measurements on the average tubular platelet concentration. The marginal layer originates from the hydrodynamic interaction of the deformable erythrocytes with the tube wall. If the tube diameter is large compared with the size of the erythrocytes, the lateral migration effects can effectively be scaled on the absolute distance between the erythrocytes and the tube wall. This results in the main conclusion that the near-wall concentration of platelets is significantly enhanced up to about seven times the average concentration, practically irrespective of the tube diameter in the range of 100-500 microns. Where comparable, the results of this study are in accordance with experimental data of other authors.

Blood Cell Count↗

Comparison of effects of dopamine hydrochloride and dopexamine hydrochloride on abdominal and femoral hemodynamics in anesthetized dogs.

The effects of dopamine and dopexamine administered in graded intravenous bolus injections (0.1-51.2 micrograms.kg-1) were compared in the renal and femoral, and in a number of splanchnic vessels at the organ level simultaneously in anesthetized dogs. Hemodynamic data are presented for each artery as conductance, which was obtained by dividing mean flow by mean arterial pressure. The data were analyzed in two different ways: 1) by responses at intervals of 3 sec to 12.8 micrograms dopamine or dopexamine during 1 min, and 2) by dose-response curves. Additionally, urine volume was measured during dopamine and dopexamine administration. During a period of 1 min after an injection of dopamine, early and late effects could be distinguished, while heart rate was unaltered. In the superior mesenteric, inferior mesenteric, splenic, common hepatic, renal, and femoral arteries, an early (at 18-21 sec) reduction in conductance was seen. The early reduction was often followed by an increase above the preinjection level. After dopexamine, the early reduction in conductance was not seen, except in the left gastric artery. In contrast to the effect of dopamine, dopexamine induced a more pronounced increase during the late phase. Contrary to dopamine, dopexamine increased the conductance in the common hepatic artery bed. It remains questionable whether dopaminergic receptors are present in this vascular bed. Dopamine raised blood pressure and urine production dose-dependently. Dopexamine decreased aortic pressure. Low dosages of dopexamine increased urine production, without raising renal blood flow. An advantage of dopexamine over dopamine could be that dopexamine does not stimulate alpha-adrenergic receptors.

Blood Flow Velocity↗

Role of plasma viscosity in platelet adhesion.

Platelet adhesion to the vessel wall is initiated by transport of blood platelets from the bulk flow to the wall. The process of diffusion and convection of the platelets is affected by rheological conditions such as well shear rate, red blood cell (RBC) deformability, and viscosity of the medium. To study the effect of plasma viscosity on platelet adhesion, perfusion experiments with a rectangular perfusion chamber were performed. Reconstituted blood, consisting of washed platelets and washed RBCs, was circulated through this chamber for 5 minutes at a wall shear rate of 300 s-1. Different albumin concentrations were made, to obtain different medium viscosities (0.89 to 1.85 mPa.s). Platelet adhesion decreased with increasing medium viscosity up to viscosities of 0.95 mPa.s, but increased with medium viscosity above this value. Instead of human albumin solution, different plasma viscosities were obtained by dilution of Waldenström plasma with buffer. Plasma was depleted of fibronectin, which gave a final plasma viscosity of 2.0 mPa.s, and was dialyzed against HEPES buffer and subsequently diluted with the dialysis buffer in different fractions (0.89 to 2.00 mPa.s). Perfusions were performed over a purified von Willebrand factor coating on glass, or over an endothelial cell matrix, preincubated with von Willebrand factor. With both surfaces, platelet adhesion was dependent on the plasma viscosity in a similar way: at low plasma viscosities, adhesion was decreased with increasing plasma viscosity, while at higher plasma viscosities, adhesion increased with plasma viscosity. Adhesion values at higher plasma viscosity or at higher human albumin concentrations could be explained by effects of the medium on the rigidity of the RBCs, since platelet adhesion is known to be increased by enhanced RBC rigidity. Effects of the medium on the deformability of the RBCs were measured separately with the laser diffraction method. These experiments confirmed that presence of human albumin or plasma in the measuring suspension increased the rigidity of RBCs. To prevent influence of the medium on the RBCs in perfusion experiments, the RBCs were fixated with glutaraldehyde. Perfusion experiments with fixated RBCs in plasma over a von Willebrand factor preincubated endothelial cell matrix, showed a consequent decrease in adhesion with increasing plasma viscosity, according to the diffusion theories, whereas the increase of adhesion at high plasma viscosities was lacking. This suggests that the latter effect was entirely due to increased transport of platelets by more rigid RBCs.

Blood Viscosity↗

Computation of steady three-dimensional flow in a model of the basilar artery.

The flow in the basilar artery arises from the merging of the flows from the two vertebral arteries. To study the flow phenomena in the basilar artery, computations have been performed using a finite element (FE) method. We consider steady flow in a geometrically symmetric confluence. For simplicity, channels with a rectangular cross-section have been used. Both symmetric and asymmetric flow cases have been considered. The results show that for the Reynolds number of interest the flow downstream of the junction is highly three-dimensional, and that the flow at the end of the basilar artery, where it splits again, will not be fully developed. The computed phenomena have been confirmed by laser Doppler velocity measurements.

Basilar Artery↗

A two-phase finite element model of the diastolic left ventricle.

A porous medium finite element model of the passive left ventricle is presented. The model is axisymmetric and allows for finite deformation, including torsion about the axis of symmetry. An anisotropic quasi-linear viscoelastic constitutive relation is implemented in the model. The model accounts for changing fibre orientation across the myocardial wall. During passive filling, the apex rotates in a clockwise direction relative to the base for an observer looking from apex to base. Within an intraventricular pressure range of 0-3 kPa the rotation angle of all nodes remained below 0.1 rad. Diastolic viscoelasticity of myocardial tissue is shown to reduce transmural differences of preload-induced sarcomere stretch and to generate residual stresses in an unloaded ventricular wall, consistent with the observation of opening angles seen when the heart is slit open. It is shown that the ventricular model stiffens following an increase of the intracoronary blood volume. At a given left ventricular volume, left ventricular pressure increases from 1.5 to 2.0 kPa when raising the intracoronary blood volume from 9 to 14 ml (100 g)-1 left ventricle.

Animals↗

The constitutive behaviour of passive heart muscle tissue: a quasi-linear viscoelastic formulation.

A quasi-linear viscoelastic law with a continuous relaxation spectrum describing triaxial constitutive behaviour of heart muscle tissue is presented. The elastic response of the viscoelastic law is anisotropic, while the relaxation behaviour is assumed isotropic. The law is designed for a biphasic description (fluid-solid) of the myocardial tissue. Biaxial and uniaxial stress-strain curves from the literature are used to evaluate the parameters of the model. The non-linear elastic response, the difference between fibre and cross-fibre stiffness, the phenomenon of stress relaxation, the stiffening of the stress-strain relationship with increasing strain rate and the weak frequency dependency of the dissipated energy during cyclic loading are fairly well described by the proposed law. However, it is found that the model produces realistic values for the dissipated energy during cyclic loading only when relaxation parameter values are chosen which result in an overestimation of the stress relaxation data by more than 100%. This finding may indicate non-quasi-linearity of viscoelasticity of passive heart muscle tissue.

Biomechanical Phenomena↗

Pathological-anatomical study concerning the geometry and atherosclerosis of the carotid bifurcation.

Besides metabolic factors haemodynamic elements are important in the development of obliterating athero-sclerosis. Since the geometry of a bifurcation influences the local bloodflow, we hypothesise that non-optimal geometry of a bifurcation leads to flow-disturbances, which can be a factor in atherogenesis. To verify our hypothesis that there is a correlation between non-optimal geometry of a bifurcation and the presence of atherosclerotic lesions, we studied as a parameter for the geometry of a bifurcation the area ratio defined as: the sum of the cross-sectional areas of the distal arteries divided by the cross-sectional area of the proximal artery. In this study the area ratios of 100 carotid bifurcations were studied by post-mortem examination. The mean value calculated for 60 normal carotid bifurcations was 1.47, and the mean for 40 diseased bifurcations was 0.99. The last value is significantly less than the theoretical optimal area ratio of 1.16, which was found by Womersley and Hunt as the value at which a minimum reflexion of pressure waves and a minimum of blood-flow energy loss occurs at a bifurcation. We conclude that a non-optimal area ratio of a carotid bifurcation seems to be a factor in atherogenesis.

Aged↗