Studies of differential red cell agglutination utilizing an electronic particle counter.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R M Greendyke.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The occurrence of the Wr a antigen on the red blood cells of 5,000 primarily Caucasian New York State blood donors was shown to be 1:1,000. Anti-Wr a was detected in sera from random blood donors with a frequency of 1:56 and with progressively increasing frequency in postpartum women, patients undergoing open-heart surgery, hemodialysis subjects, and random persons with other alloantibodies. Anti-Wr a was found in one fourth of sera from patients with positive direct antiglobulin tests, including 12 of 23 in whom the positive test was associated with alphamethyldopa treatment.
Explore the source record for details and available documents.
Experiments were conducted using the technique of quantitative hemagglutination with an electronic particle counter to study the specific and nonspecific uptake of blood group antibodies by previously sensitized erythrocytes. Specific attachment of a second antibody was impaired by prior RBC sensitization. It was found possible to quantitate simultaneously the amount of both specific and nonspecific second antibody uptake.
Six procedures for compatibility testing were compared, using red blood cells sensitized in normal saline, albumin or low-ionic strength saline (LISS) combined with either broad spectrum or anti-IgG antiglobulin testing (AGT). Despite shortened incubation times, tests employing LISS were as sensitive as those with albumin and broad spectrum AGT and more sensitive than the other four combinations. No false positive results were found. LISS technique with broad spectrum AGT appears to be suitable and superior for routine antibody detection and compatibility tests.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.