Search PubMed⌕ Search

Biomedical subjects

R Langer

Publications and source records attributed to R Langer.

At least 91 records · Page 5Linked to original sources

Cardiac tissue engineering: cell seeding, cultivation parameters, and tissue construct characterization.

Cardiac tissue engineering has been motivated by the need to create functional tissue equivalents for scientific studies and cardiac tissue repair. We previously demonstrated that contractile cardiac cell-polymer constructs can be cultivated using isolated cells, 3-dimensional scaffolds, and bioreactors. In the present work, we examined the effects of (1) cell source (neonatal rat or embryonic chick), (2) initial cell seeding density, (3) cell seeding vessel, and (4) tissue culture vessel on the structure and composition of engineered cardiac muscle. Constructs seeded under well-mixed conditions with rat heart cells at a high initial density ((6-8) x 10(6) cells/polymer scaffold) maintained structural integrity and contained macroscopic contractile areas (approximately 20 mm(2)). Seeding in rotating vessels (laminar flow) rather than mixed flasks (turbulent flow) resulted in 23% higher seeding efficiency and 20% less cell damage as assessed by medium lactate dehydrogenase levels (p < 0.05). Advantages of culturing constructs under mixed rather than static conditions included the maintenance of metabolic parameters in physiological ranges, 2-4 times higher construct cellularity (p &le 0.0001), more aerobic cell metabolism, and a more physiological, elongated cell shape. Cultivations in rotating bioreactors, in which flow patterns are laminar and dynamic, yielded constructs with a more active, aerobic metabolism as compared to constructs cultured in mixed or static flasks. After 1-2 weeks of cultivation, tissue constructs expressed cardiac specific proteins and ultrastructural features and had approximately 2-6 times lower cellularity (p < 0.05) but similar metabolic activity per unit cell when compared to native cardiac tissue.

Animals↗

Bacterial inactivation by using near- and supercritical carbon dioxide.

The three most common methods of sterilization in use today are ethylene oxide exposure, gamma-irradiation, and steam sterilization. Each of these methods has serious limitations for the sterilization of some materials used in medicine, especially thermally and hydrolytically sensitive polymers by themselves and in combination with proteins. In this work, we demonstrate a potential new method of sterilization by using supercritical fluid carbon dioxide. Using this method we achieve complete inactivation of a wide variety of bacterial organisms at moderate temperatures and in the absence of organic solvents or irradiation. Sterilization is a function of both the proximity to the fluid's critical point and the chemical nature of the fluid itself. When biodegradable polymers poly(lactic-co-glycolic) acid and polylactic acid were included in the sterilization process, there was no effect on the inactivation efficiency, yet no physical or chemical damage to these thermally and hydrolytically labile materials was observed.

Bacteria↗

Regional heparinization via simultaneous separation and reaction in a novel Taylor-Couette flow device.

The development of a safe and efficient bioreactor design has remained a challenge for the clinical application of immobilized enzymes. Specifically, the use of immobilized heparinase I has been the target of many studies to make heparin anticoagulation therapy safer for the critically ill patient with kidney failure or heart disease. We have investigated the use of Taylor-Couette flow for a novel type of bioreactor. In a previous study, we showed that the fluidization of agarose immobilized heparinase within Taylor vortices in whole blood can lead to extensive blood damage in the form of cell depletion and hemolysis. Based on these findings, we designed and developed a reactor, referred to as vortex-flow plasmapheretic reactor (VFPR), that incorporated plasmapheresis and fluidization of the agarose in the reactive compartment, separate from the whole-blood path. In the present study, immobilized heparinase I was tested as a means of achieving regional heparinization of a closed circuit. This is a method in which heparin is infused into the extracorporeal circuit predialyzer and neutralized postdialyzer. Saline studies were performed with an immobilized heparinase I-packed bed and with the VFPR. An in vitro feasibility study was performed with the VFPR using human blood. The VFPR achieved heparin conversions of 44 +/- 0.5% and 34 +/- 2% in saline and blood, respectively. In addition, the VFPR caused no blood damage. We report a novel method to achieve fluidization which depended on secondary, circumferencial flow, and was independent of the primary flow through the device.

Biocompatible Materials↗

Functional arteries grown in vitro.

A tissue engineering approach was developed to produce arbitrary lengths of vascular graft material from smooth muscle and endothelial cells that were derived from a biopsy of vascular tissue. Bovine vessels cultured under pulsatile conditions had rupture strengths greater than 2000 millimeters of mercury, suture retention strengths of up to 90 grams, and collagen contents of up to 50 percent. Cultured vessels also showed contractile responses to pharmacological agents and contained smooth muscle cells that displayed markers of differentiation such as calponin and myosin heavy chains. Tissue-engineered arteries were implanted in miniature swine, with patency documented up to 24 days by digital angiography.

Animals↗

Troponin I is present in human cartilage and inhibits angiogenesis.

Cartilage is an avascular and relatively tumor-resistant tissue. Work from a number of laboratories, including our own, has demonstrated that cartilage is an enriched source of endogenous inhibitors of angiogenesis. In the course of a study designed to identify novel cartilage-derived inhibitors of new capillary growth, we have purified an inhibitory protein that was identified by peptide microsequencing and protein database analysis as troponin I (TnI). TnI is a subunit of the troponin complex (troponin-C and troponin-T being the other two), which, along with tropomyosin, is responsible for the calcium-dependent regulation of striated muscle contraction; independently, TnI is capable of inhibiting actomyosin ATPase. Because troponin has never previously been reported to be present in cartilage, we have cloned and expressed the cDNA of human cartilage TnI, purified this protein to apparent homogeneity, and demonstrated that it is a potent and specific inhibitor of angiogenesis in vivo and in vitro, as well as of tumor metastasis in vivo.

3T3 Cells↗

Transdermal photopolymerization for minimally invasive implantation.

Photopolymerizations are widely used in medicine to create polymer networks for use in applications such as bone restorations and coatings for artificial implants. These photopolymerizations occur by directly exposing materials to light in "open" environments such as the oral cavity or during invasive procedures such as surgery. We hypothesized that light, which penetrates tissue including skin, could cause a photopolymerization indirectly. Liquid materials then could be injected s.c. and solidified by exposing the exterior surface of the skin to light. To test this hypothesis, the penetration of UVA and visible light through skin was studied. Modeling predicted the feasibility of transdermal polymerization with only 2 min of light exposure required to photopolymerize an implant underneath human skin. To establish the validity of these modeling studies, transdermal photopolymerization first was applied to tissue engineering by using "injectable" cartilage as a model system. Polymer/chondrocyte constructs were injected s.c. and transdermally photopolymerized. Implants harvested at 2, 4, and 7 weeks demonstrated collagen and proteoglycan production and histology with tissue structure comparable to native neocartilage. To further examine this phenomenon and test the applicability of transdermal photopolymerization for drug release devices, albumin, a model protein, was released for 1 week from photopolymerized hydrogels. With further study, transdermal photpolymerization potentially could be used to create a variety of new, minimally invasive surgical procedures in applications ranging from plastic and orthopedic surgery to tissue engineering and drug delivery.

Animals↗

Investigation of a whole blood fluidized bed Taylor-Couette flow device for enzymatic heparin neutralization.

The use of clinical bioreactors will increase as more therapeutic proteins are being cloned, expressed, and produced at a reduced cost. The proposed use of an immobilized heparinase I reactor to make heparin anticoagulation a safer therapy is an example of how the specificity and high activity of an enzyme could be incorporated into a system to ultimately benefit a patient. However, the development of a safe and efficient bioreactor is important for the use of immobilized heparinase I and other therapeutic proteins designed for use in medical extracorporeal procedures. This study examined the possibility of using Taylor-Couette flow and "flow-induced" recirculation of the agarose beads as a way to fluidize agarose-bound heparinase in whole blood. Heparinase I was immobilized onto agarose beads via cyanogen bromide activation. A reactor based on Taylor-Couette flow was designed and modified with a tangential recirculation line. The reactor was tested for efficacy and safety in vitro in human blood. Visualization studies in water and 42% glycerol were used to determine the minimum rotation rate for efficient fluidization. The strategic placement of the recirculation line allowed recirculation of the agarose without the use of an external pump. The device removed 90% of the heparin activity within 2 min from 450 cc of human blood at a blood flow rate of 100 mL/min. Furthermore, the device maintained inlet and outlet clotting times of 269 +/- 10 and 235 +/- 6 s, respectively, demonstrating the potential for regional heparinization. Blood damage was a function of gel volume fraction and rotation rate of the inner cylinder. Hemolysis of the red cells is an important issue when Taylor vortices are combined with macroscopic solid particles such as agarose beads. A modified Taylor-Couette flow device was developed to treat whole blood and operational criteria were established to minimize hemolysis.

Bioreactors↗

Ex vivo evaluation of a Taylor-Couette flow, immobilized heparinase I device for clinical application.

Efficient and safe heparin anticoagulation has remained a problem for continuous renal replacement therapies and intermittent hemodialysis for patients with acute renal failure. To make heparin therapy safer for the patient with acute renal failure at high risk of bleeding, we have proposed regional heparinization of the circuit via an immobilized heparinase I filter. This study tested a device based on Taylor-Couette flow and simultaneous separation/reaction for efficacy and safety of heparin removal in a sheep model. Heparinase I was immobilized onto agarose beads via cyanogen bromide activation. The device, referred to as a vortex flow plasmapheretic reactor, consisted of two concentric cylinders, a priming volume of 45 ml, a microporous membrane for plasma separation, and an outer compartment where the immobilized heparinase I was fluidized separately from the blood cells. Manual white cell and platelet counts, hematocrit, total protein, and fibrinogen assays were performed. Heparin levels were indirectly measured via whole-blood recalcification times (WBRTs). The vortex flow plasmapheretic reactor maintained significantly higher heparin levels in the extracorporeal circuit than in the sheep (device inlet WBRTs were 1. 5 times the device outlet WBRTs) with no hemolysis. The reactor treatment did not effect any physiologically significant changes in complete blood cell counts, platelets, and protein levels for up to 2 hr of operation. Furthermore, gross necropsy and histopathology did not show any significant abnormalities in the kidney, liver, heart, brain, and spleen.

Acute Kidney Injury↗

A controlled-release microchip.

Much previous work in methods of achieving complex drug-release patterns has focused on pulsatile release from polymeric materials in response to specific stimuli, such as electric or magnetic fields, exposure to ultrasound, light or enzymes, and changes in pH or temperature. An alternative method for achieving pulsatile release involves using microfabrication technology to develop active devices that incorporate micrometre-scale pumps, valves and flow channels to deliver liquid solutions. Here we report a solid-state silicon microchip that can provide controlled release of single or multiple chemical substances on demand. The release mechanism is based on the electrochemical dissolution of thin anode membranes covering microreservoirs filled with chemicals in solid, liquid or gel form. We have conducted proof-of-principle release studies with a prototype microchip using gold and saline solution as a model electrode material and release medium, and we have demonstrated controlled, pulsatile release of chemical substances with this device.

Biocompatible Materials↗

Proliferation, morphology, and protein expression by osteoblasts cultured on poly(anhydride-co-imides).

In vitro cell biocompatibility models are crucial in the study of any newly synthesized material. Our focus has been on the development of a new class of biocompatible, degradable, high-strength polymeric materials, the poly(anhydride-co-imides), for use in bone regeneration. This study examined osteoblast cell adherence, proliferation, viability, and phenotypic preservation on the surface of the poly(anhydride-co-imide) poly[pyromellitylimidoalanine (PMA-ala):1,6-bis(carboxyphenoxy) hexane (CPH)] over a period of time. Cell proliferation on PMA-ala:CPH degradable matrices over 21 days was examined. Throughout the 21-day period of study, osteoblast proliferation was similar on PMA-ala:CPH and on tissue culture polystyrene controls. Osteoblasts maintained their characteristic morphology as demonstrated by both scanning electron microscopy and immunofluorescence studies. Alkaline phosphatase activity for cells grown on PMA-ala:CPH was confirmed. Retention of the osteoblastic phenotype was demonstrated using immunofluorescence techniques and staining with antibodies against osteocalcin (an extracellular matrix protein of bone) and osteopontin (a marker of cell adhesion). Radioimmunoassay results provided evidence that levels of osteocalcin production by osteoblasts were similar when cells were cultured on PMA-ala:CPH and on tissue culture polystyrene controls. The present study provided evidence of normal osteoblast function on PMA-ala:CPH surfaces. PMA-ala:CPH may therefore be useful as a synthetic material for orthopedic applications.

Animals↗

Morphology and mechanical function of long-term in vitro engineered cartilage.

Cartilage tissue can be engineered in vitro with articular chondrocytes and poly(glycolic acid) nonwoven scaffolds as previously shown over 12 weeks in vitro. This study addressed whether engineered cartilage would further evolve and approach natural cartilage in extracellular matrix organization and biomechanical properties, especially aggregate modulus through longer term in vitro cultivation. Cellularity, cell size, compressive modulus, and permeability of the in vitro engineered cartilage stabilized within the 12-week cultivation time and remained at the same levels as those of natural cartilage thereafter. The linear range of the stress-strain curve was from 0 to a strain value between 5 and 10% for all the engineered cartilage tissues that were in vitro cultured for longer than 2 weeks, which was the same linear range for natural cartilage. The aggregate modulus further increased from week 12 to week 20 and remained approximately the same value thereafter during a 25-week in vitro cultivation. The aggregate modulus of the engineered cartilage reached 179+/-9 kPa after 20 weeks of in vitro cultivation, which was 40% that of natural articular cartilage. To our knowledge this is the highest aggregate modulus value yet reported of any in vitro engineered cartilage tissue.

Animals↗

Bioreactor cultivation conditions modulate the composition and mechanical properties of tissue-engineered cartilage.

Cartilaginous constructs have been grown in vitro with use of isolated cells, biodegradable polymer scaffolds, and bioreactors. In the present work, the relationships between the composition and mechanical properties of engineered cartilage constructs were studied by culturing bovine calf articular chondrocytes on fibrous polyglycolic acid scaffolds (5 mm in diameter, 2-mm thick, and 97% porous) in three different environments: static flasks, mixed flasks, and rotating vessels. After 6 weeks of cultivation, the composition, morphology, and mechanical function of the constructs in radially confined static and dynamic compression all depended on the conditions of in vitro cultivation. Static culture yielded small and fragile constructs, while turbulent flow in mixed flasks yielded constructs with fibrous outer capsules; both environments resulted in constructs with poor mechanical properties. The constructs that were cultured freely suspended in a dynamic laminar flow field in rotating vessels were the largest, contained continuous cartilage-like extracellular matrices with the highest fractions of glycosaminoglycan and collagen, and had the best mechanical properties. The equilibrium modulus, hydraulic permeability, dynamic stiffness, and streaming potential correlated with the wet-weight fractions of glycosaminoglycan, collagen, and water. These findings suggest that the hydrodynamic conditions in tissue-culture bioreactors can modulate the composition, morphology, mechanical properties, and electromechanical function of engineered cartilage.

Animals↗

Tissue engineering of autologous aorta using a new biodegradable polymer.

BACKGROUND: Ovine pulmonary valve leaflets and pulmonary arteries have been tissue-engineered (TE) from autologous cells and biodegradable polyglycolic acid (PGA)-polyglactin copolymers. Use of this cell-polymer construct in the systemic circulation resulted in aneurysm formation. This study evaluates a TE vascular graft in the systemic circulation which is based on a new copolymer of PGA and polyhydroxyalkanoate (PHA). METHODS: Ovine carotid arteries were harvested, expanded in vitro, and seeded onto 7-mm diameter PHA-PGA tubular scaffolds. The autologous cell-polymer vascular constructs were used to replace 3-4 cm abdominal aortic segments in lambs (group TE, n = 7). In a control group (n = 4), aortic segments were replaced with acellular polymer tubes. Vascular patency was evaluated with echography. All control animals were sacrificed when the grafts became occluded. Animals in TE group were sacrificed at 10 days (n = 1), 3 (n = 3), and 5 months (n = 3). Explanted TE conduits were evaluated for collagen content, deoxyribonucleic acid (DNA) content, structural and ultrastructural examination, mechanical strength, and matrix metalloproteinase (MMP) activity. RESULTS: The 4 control conduits became occluded at 1, 2, 55, and 101 days. All TE grafts remained patent, and no aneurysms developed by the time of sacrifice. There was one mild stenosis at the anastomotic site after 5 months postoperatively. The percent collagen and DNA contents approached the native aorta over time (% collagen = 25.7%+/-3.4 [3 months] vs 99.6%+/-11.7 [5 months], p < 0.05; and % DNA = 30.8%+/-6.0 [3 months] vs 150.5%+/-16.9 [5 months], p < 0.05). Histology demonstrated elastic fibers in the medial layer and endothelial specific von Willebrand factor on the luminal surface. The mechanical strain-stress curve of the TE aorta approached that of the native vessel. A 66 kDa MMP-2 was found in the TE and native aorta but not in control group. CONCLUSIONS: Autologous aortic grafts with biological characteristics resembling the native aorta can be created using TE approach. This may allow the development of "live" vascular grafts.

Animals↗

An analysis of the size selectivity of solute partitioning, diffusion, and permeation across lipid bilayers.

The lipid bilayers of cell membranes are primarily responsible for the low passive transport of nonelectrolytes across cell membranes, and for the pronounced size selectivity of such transport. The size selectivity of bilayer permeation has been hypothesized to originate from the hindered transport of solutes across the ordered-chain region. In this paper, we develop a theoretical description that provides analytical relationships between the permeation properties of the ordered-chain region of the lipid bilayer (partition and diffusion coefficients) and its structural properties, namely, lipid chain density, free area, and order parameter. Emphasis is placed on calculating the size selectivity of solute partitioning, diffusion, and overall permeability across the ordered-chain region of the lipid bilayer. The size selectivity of solute partitioning is evaluated using scaled-particle theory, which calculates the reversible work required to create a cavity to incorporate a spherical solute into the ordered-chain region of the lipid bilayer. Scaled-particle theory is also used to calculate the work required to create a diffusion path for solutes in the interfacial region of the lipid bilayer. The predicted size dependence of the bilayer permeability is comparable to that observed experimentally. The dependence of solute partition and diffusion coefficients on the bilayer structural parameters is also discussed.

Diffusion↗

Charged microbeads are not transported across the human stratum corneum in vitro by short high-voltage pulses.

There have been several reports of particle transport due to high-voltage pulsing of human skin. Here, several different short, high-voltage pulsing protocols were used in vitro to study the possible transport of highly charged, fluorescent polystyrene particles (14 nm to 2.1 microns in diameter; surface charges of -4.05 x 10(3) e to -2.77 x 10(7) e) across the skin. Two different methods were used to trap and measure particles on the other side of the skin. The first used a polycarbonate membrane to trap the particles, determining the amount of transport by enumeration under a fluorescence microscope. The second used spectrofluorimetry to measure the amount of particles transported. After pulsing, particles were found in randomly distributed clusters on the surface of the skin. No detectable transport across the stratum corneum for any size particle was observed.

Administration, Cutaneous↗

Creation of transdermal pathways for macromolecule transport by skin electroporation and a low toxicity, pathway-enlarging molecule.

A combined electrical (HV, "high voltage", pulsing) and chemical (topical sodium thiosulfate) intervention is hypothesized to create enlarged aqueous pathways that allow large quantities of macromolecules to be transported through human skin's stratum corneum (SC), the dominant barrier for transdermal drug delivery and biochemical analyte extraction. This expectation is based on the known structure and composition of the SC, and previous models and experiments for local transport regions (LTRs) due to transdermal HV pulsing. In vitro experiments demonstrated that transdermal macromolecule fluxes of 10(-9) to 10(-8) mol h(-1) cm(-2) (10 to 100 microg h(-1) cm(-2)) or greater are possible for lactalbumin and an antibody (IgG), which are potentially therapeutic values for peptides, proteins and nucleic acids. In the absence of sodium thiosulfate, only a small molecule (sulforhodamine) flux increased significantly, consistent with many previous studies. Significant macromolecule transdermal fluxes occurred only if a pathway enlarging molecule (sodium thiosulfate) was present. Our results also provide support for the mechanism hypothesis that HV pulses leading to transdermal voltages U(skin) > 50 V create straight-through aqueous pathways that penetrate multilamellar bilayer membranes, corneocyte envelopes and corneocyte interiors within the SC.

Electroporation↗