Search PubMed⌕ Search

Biomedical subjects

R L Reis

Publications and source records attributed to R L Reis.

At least 55 records · Page 3Linked to original sources

The biocompatibility of novel starch-based polymers and composites: in vitro studies.

Studies with biodegradable starch-based polymers have recently demonstrated that these materials have a range of properties. which make them suitable for use in several biomedical applications, ranging from bone plates and screws to drug delivery carriers and tissue engineering scaffolds. The aim of this study was to screen the cytotoxicity and evaluate starch-based polymers and composites as potential biomaterials. The biocompatibility of two different blends of corn-starch, starch ethylene vinyl alcohol (SEVA-C) and starch cellulose acetate (SCA) and their respective composites with hydroxyapatite (HA) was assessed by cytotoxicity and cell adhesion tests. The MTT assay was performed with the extracts of the materials in order to evaluate the short-term effect of the degradation products. The cell morphology of L929 mouse fibroblast cell line was also analysed after direct contact with polymers and composites for different time periods and the number of cells adhered to the surface of the polymers was determined by quantification of the cytosolic lactate dehydrogenase (LDH) activity. Both types of starch-based polymers exhibit a cytocompatibility that might allow for their use as biomaterials. SEVA-C blends were found to be the less cytotoxic for the tested cell line, although cells adhere better to SCA surface. The cytotoxicity test also revealed that SCA and SEVA-C composites have a similar response to the one obtained for SCA polymer. Scanning electron microscopy (SEM) analysis showed that cells were much more spread on the SCA polymer and LDH measurements showed a higher number of cells on this surface.

Animals↗

Starch-based biodegradable hydrogels with potential biomedical applications as drug delivery systems.

The design and preparation of novel biodegradable hydrogels developed by the free radical polymerization of acrylamide and acrylic acid, and some formulations with bis-acrylamide, in the presence of a corn starch/ethylene-co-vinyl alcohol copolymer blend (SEVA-C), is reported. The redox system benzoyl peroxide (BPO) and 4-dimethylaminobenzyl alcohol (DMOH) initiated the polymerization at room temperature. Xerogels were characterized by 1H NMR and FTIR spectroscopies. Swelling studies were performed as a function of pH in different buffer solutions determining the water-transport mechanism that governs the swelling behaviour. Degradation studies of the hydrogels were performed in simulated physiological solutions for time up to 90 days, determining the respective weight loss, and analyzing the solution residue by 1H NMR. The mechanical properties of the xerogels were characterized by tensile and compressive tests, as well as by dynamo-mechanical analysis (DMA). Dynamo-mechanical parameters are also reported for hydrated samples.

Aniline Compounds↗

Novel starch thermoplastic/Bioglass composites: mechanical properties, degradation behavior and in-vitro bioactivity.

The present research aims to evaluate the possibility of creating new degradable, stiff and highly bioactive composites based on a biodegradable thermoplastic starch-based polymeric blend and a Bioglass filler. Such combination should allow for the development of bioactive and degradable composites with a great potential for a range of temporary applications. A blend of starch with ethylene-vinyl alcohol copolymer (SEVA-C) was reinforced with a 45S5 Bioglass powder presenting a granulometric distribution between 38 and 53 microm. Composites with 10 and 40 wt % of 45S5 Bioglass were compounded by twin-screw extrusion (TSE) and subsequently injection molded under optimized conditions. The mechanical properties of the composites were evaluated by tensile testing, and their bioactivity assessed by immersion in a simulated body fluid (SBF) for different periods of time. The biodegradability of these composites was also monitored after several immersion periods in an isotonic saline solution. The tensile tests results obtained indicated that SEVA-C/Bioglass composites present a slightly higher stiffness and strength (a modulus of 3.8 GPa and UTS of 38.6 MPa) than previously developed SEVA-C/Hydroxylapatite (HA) composites. The bioactivity of SEVA-C composites becomes relevant for 45S5 amounts of only 10 wt %. This was observed by scanning electron microscopy (SEM) and confirmed for immersion periods up to 30 days by both thin-film X-ray diffraction (TF-XRD) (where HA typical peaks are clearly observed) and induced coupled plasma emission (ICP) spectroscopy used to follow the elemental composition of the SBF as function of time. Additionally, it was observed that the composites are biodegradable being the results correlated with the correspondent materials composition.

Journal Article↗

Cell adhesion and proliferation on biomimetic calcium-phosphate coatings produced by a sodium silicate gel methodology.

The present study describes a methodology to produce bioactive coatings on the surface of starch based biodegradable polymers or other polymeric biomaterials. As an alternative to the more typical bioactive glass percursors, a sodium silicate gel is being employed as a nucleating agent, for inducing the formation of a calcium-phosphate (Ca-P) layer. The method has the advantage of being able to coat efficiently both compact materials and porous 3D architectures aimed at being used on tissue replacement applications and as bone tissue engineering scaffolds. This treatment is also very effective in reducing the incubation periods, being possible to observe the formation of an apatite-like layer, only after 6 h of immersion in a simulated body fluid (SBF). The influence of the SBF concentration on the formation of the apatite coating was also studied. The apatite coatings formed under different conditions were analyzed and compared in terms of morphology, chemical composition and structure. After the first days of SBF immersion, the apatite-like films exhibit the typical cauliflower like morphology. With increasing immersion times, these films exhibited a partially amorphous nature and the Ca/P ratios became very closer to the value attributed to hydroxyapatite (1.67). The obtained results are very promising for pre-calcifying bone tissue engineering scaffolds. Therefore, in order to study cell behavior and response to these apatite coatings, adhesion, morphology, and proliferation of a human osteoblast cell line (SaOS-2) was also analyzed after being cultured in the coatings formed after 15 days of immersion in SBF. Results indicate a good correlation between crystallinity of the apatite like coatings formed in these conditions and respective cell spreading and morphology. In general, higher cell proliferation was observed for higher crystalline Ca-P coatings.

Journal Article↗

A new approach based on injection moulding to produce biodegradable starch-based polymeric scaffolds: morphology, mechanical and degradation behaviour.

One of the present challenges in polymer scaffold processing is the fabrication of three-dimensional (3D) architectures with an adequate mechanical performance to be used in the tissue engineering of hard tissues. This paper describes a preliminary study on the development of a new method to produce biodegradable scaffolds from a range of corn-starch-based polymers. In some cases, hydroxlapatite was also used as a reinforcement of the biodegradable polymers. The developed methodology consists of a standard conventional injection moulding process, on which a solid blowing agent based on carboxylic acids is used to generate the foaming of the bulk of the moulded part. The proposed route allows for the production of scaffolds with a compact skin and a porous core, with promising mechanical properties. By using the developed method it is possible to manufacture biodegradable polymer scaffolds in an easy (melt-based processing) and reproducible manner. The scaffolds can be moulded into complex shapes, and the blowing additives do not affect the non-cytotoxic behaviour of the starch-based materials. The materials produced using this method were evaluated with respect to the morphology of the porous structure, and the respective mechanical properties and degradation behaviour. It was demonstrated that it is possible to obtain, by a standard melt based processing route, 3D scaffolds with complex shapes that exhibit an appropriate morphology, without decreasing significantly the mechanical properties of the materials. It is believed that the optimisation of the proposed processing methodology may lead to the production of scaffolds that might be used on the regeneration of load-bearing tissues.

Biocompatible Materials↗

Cytocompatibility and response of osteoblastic-like cells to starch-based polymers: effect of several additives and processing conditions.

This work reports on the biocompatibility evaluation of new biodegradable starch-based polymers that are under consideration for use in orthopaedic temporary applications and as tissue engineering scaffolds. It has been shown in previous works that by using these polymers it is both possible to produce polymer/hydroxyapatite (HA) composites (with or without the use of coupling agents) with mechanical properties matching those of the human bone, and to obtain 3D structures generated by solid blowing agents, that are suitable for tissue engineering applications. This study was focused on establishing the influence of several additives (ceramic fillers, blowing agents and coupling agents) and processing methods/conditions on the biocompatibility of the materials described above. The cytotoxicity of the materials was evaluated using cell culture methods, according to ISO/EN 109935 guidelines. A cell suspension of human osteosarcoma cells (HOS) was also seeded on a blend of corn starch with ethylene vinyl alcohol (SEVA-C) and on SEVA-C/HA composites, in order to have a preliminary indication on cell adhesion and proliferation on the materials surface. In general, the obtained results show that all the different materials based on SEVA-C, (which are being investigated for use in several biomedical applications), as well as all the additives (including the novel coupling agents) and different processing methods required to obtain the different properties/products, can be used without inducing a cytotoxic behaviour to the developed biomaterials.

Animals↗

Biocompatibility testing of novel starch-based materials with potential application in orthopaedic surgery: a preliminary study.

This paper describes an extensive biocompatibility evaluation of biodegradable starch-based materials aimed at orthopaedic applications as temporary bone replacement/fixation implants. For that purpose, a polymer (starch/ethylene vinyl alcohol blend, SEVA-C) and a composite of SEVA-C reinforced with hydroxyapatite (HA) particles, were evaluated in both in vitro and in vivo assays. For the in vitro analysis cell culture methods were used. The in vivo tissue reactions were evaluated in an intramuscular and intracortical bone implantation model on goats, using light and scanning electron microscopy. A computerized image analysis system was used to obtain histomorphometric data regarding bone contact and remodelling after 6 and 12 weeks of implantation. In both in vitro and in vivo models, the SEVA-C-based materials did not induce adverse reactions, which in addition to their bone-matching mechanical properties makes them promising materials for bone replacement fixation.

Animals↗

Porous starch-based drug delivery systems processed by a microwave route.

Abstract-A new simple processing route to produce starch-based porous materials was developed based on a microwave baking methodology. This innovative processing route was used to obtain non-loaded controls and loaded drug delivery carriers, incorporating a non-steroid anti-inflammatory agent. This bioactive agent was selected as model drug with expectations that the developed methodology might be used for other drugs and growth factors. The prepared systems were characterized by 1H and 13C NMR spectroscopy which allow the study of the interactions between the starch-based materials and the processing components, i.e, the blowing agents. The porosity of the prepared materials was estimated by measuring their apparent density and studied by comparing drug-loaded and non-loaded carriers. The behaviour of the porous structures, while immersed in aqueous media, was studied in terms of swelling and degradation, being intimately related to their porosity. Finally, in vitro drug release studies were performed showing a clear burst effect, followed by a slow controlled release of the drug over several days (up to 10 days).

Biocompatible Materials↗

Surface modification tailors the characteristics of biomimetic coatings nucleated on starch-based polymers.

This work describes the influence of surface pretreatments over the nucleation and growth of an apatite layer, formed by a biomimetic process, on which a bioactive glass is used as a precursor of the calcium-phosphate (Ca-P) formation on the materials surface. SEVA-C, a corn starch-based biodegradable blend, was used as substrate. The surfaces were pretreated during various periods by: (i) physical methods, namely ultraviolet radiation (u.v.), and over exposure to ethylene oxide sterilization (EtO); and (ii) chemical methods, namely potassium hydroxide (KOH) and acetic anhydride (CH3CO)2 etchings. The surface modifications, performed before the production of the biomimetic coatings, resulted in a faster formation of Ca-P nuclei during the first stages of SBF immersion, particularly in the case of the KOH etching. In this case, it was possible to observe a decrease in the average surface roughness, as measured by laser profilometry, and an increase of the hydrophilicity of the material, which was evident from a clear increment in the water-uptake ability and quantified by contact angle measurements. With this treatment it was possible not only to reduce the induction period for the formation of a well defined and dense apatite-like layer, as observed by scanning electron microscopy (SEM), but also to improve the adhesion of the Ca-P layer to the substrate, as confirmed by the adhesion strength tests. For all the studied pre-treatments, the composition of the films, analyzed by energy dispersive spectroscopy (EDS) and identified by thin-film X-ray diffraction (TF-XRD), seems to be very similar to that of human bone apatites.

Journal Article↗

Dynamic mechanical properties of hydroxyapatite-reinforced and porous starch-based degradable biomaterials.

It has been shown that blends of starch with a poly(ethylene-vinyl-alcohol) copolymer, EVOH, designated as SEVA-C, present an interesting combination of mechanical, degradation and biocompatible properties, specially when filled with hydroxyapatite (HA). Consequently, they may find a range of applications in the biomaterials field. This work evaluated the influence of HA fillers and of blowing agents (used to produce porous architectures) over the viscoelastic properties of SEVA-C polymers, as seen by dynamic mechanical analysis (DMA), in order to speculate on their performances when withstanding cyclic loading in the body. The composite materials presented a promising performance under dynamic mechanical solicitation conditions. Two relaxations were found being attributed to the starch and EVOH phases. The EVOH relaxation process may be very useful in vivo improving the implants performance under cyclic loading. DMA results also showed that it is possible to produce SEVA-C compact surface/porous core architectures with a mechanical performance similar to that of SEVA-C dense materials. This may allow for the use of these materials as bone replacements or scaffolds that must withstand loads when implanted.

Journal Article↗

New starch-based thermoplastic hydrogels for use as bone cements or drug-delivery carriers.

The development of new biodegradable hydrogels, based on corn starch/cellulose acetate blends, produced by free-radical polymerization with methyl methacrylate monomer (MMA) and/or an acrylic acid monomer (AA), is reported. The polymerization was initiated by a redox system consisting of a benzoyl peroxide and 4-dimethlyaminobenzyl alcohol at low temperature. These hydrogels may constitute an alternative to the materials currently used as bone cements or drug-delivery carriers. Swelling studies were carried out, as a function of pH and temperature, in buffered solutions. The xerogels were further characterized by Fourier transform-infrared spectroscopy. Tensile and compression tests, and dynamic mechanical thermal analysis were used to assess the mechanical performance of the developed materials. The fracture surfaces were observed by scanning electron microscopy. The developed materials are sensitive to the pH, showing a clear reversible transition in a relatively narrow interval of pH, which is just in the range of physiological conditions. These properties make the materials developed in this study very promising for biomedical applications. Fickian-type diffusion is the mechanism predominant in these systems, except for the composition with a higher concentration of AA, that corresponds to the most desirable kinetical behavior for controlled release (case II-transport mechanism). Furthermore, the results obtained in the mechanical tests are in the range of those reported for typical PMMA bone cements, showing that it is possible to develop partially degradable cements with an adequate mechanical behavior.

Journal Article↗

Treatments to induce the nucleation and growth of apatite-like layers on polymeric surfaces and foams.

In this work, a bioactive glass is used as a percusor of calcium-phosphate (Ca-P) film deposition onto several polymer-based materials. Both bioinert (high molecular weight polyethylene, HMWPE), and biodegradable (corn starch-based blends, SEVA-C) polymers, unreinforced or reinforced with hydroxylapatite (HA), were coated by the very simple proposed route. Also polyurethane (PU) foams, with an open-cell structure, were mineralized by the proposed method. In fact, it was possible to induce the growth of the Ca-P films not only at the surface, but also in the bulk of the PU foam. These cellular materials are intended for cancellous bone replacement applications. The morphology of the formed films was strongly dependent on the used substrate, its polar character, and on the presence of HA in its composition, as observed by SEM. Nevertheless, a well defined needly like structure was observed in all samples at high magnifications. The Ca:P ratios of the films were between 1.5 and 1.7, i.e. in the range of tricalcium phosphate-hydroxylapatite. Raman spectroscopy and thin-film x-ray diffraction (XRD) evidenced the formation of mostly amorphous calcium-phosphate films. After scraping the coating from the polymer surface and heat-treating the resulting powder at 1000 degrees C for 1 h, HA and beta-tricalcium phosphate (TCP) typical peaks were found on XRD patterns.

Journal Article↗

Microstructural characterization of glass-reinforced hydroxyapatite composites.

The influence of phosphate-based glasses and a bioactive silica glass on the sintering mechanism of hydroxyapatite was studied over a wide range of temperatures. The composites were microstructurally characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). Small additions of phosphate-based glasses proved to be beneficial to the sintering process and fully dense materials were obtained. A significant improvement in mechanical properties was achieved. beta-TCP and alpha-TCP were found in the microstructure depending on the sintering temperature. Additions of bioactive glass led to the development of calcium phosphate silicate.

Biocompatible Materials↗

Differential photoabsorption using argon laser radiation on atherosclerotic plaque in non-hemolyzed and hemolyzed blood.

Since argon laser radiation (488 to 514 nm) can vaporize human atherosclerotic plaque, we determined whether different blood media--hemolyzed versus non-hemolyzed blood--can alter photoabsorption of atherosclerotic plaque. Forty cadaveric aortic fibrous plaque samples were fitted onto small vials containing 0.02 ml of either non-hemolyzed blood or hemolyzed blood over the surface of the plaque. The distal end of a 400-mu core diameter quartz fiber was directed onto the surface of the plaque and the proximal end of the fiber was connected to an argon laser. The vaporized area and depth of plaque penetration were measured and the estimated volume of crater formation was derived. Following 2.5, 5, 10 and 20 J of laser energies, vaporized volumes were 0.12, 0.72, 0.97 and 4.09 mm3, respectively, for hemolyzed blood and were 0 (p less than 0.01), 0 (p less than 0.01), 0.92 (NS) and 4.39 mm3 (NS), respectively, for non-hemolyzed blood. Laser radiation destroys red blood cells; the higher the energies, the greater the hemolysis. Thus, different blood media such as hemolyzed and non-hemolyzed blood can alter photoabsorption of atherosclerotic plaque. Low level argon laser absorption upon plaque can occur under hemolyzed blood but not under non-hemolyzed blood. Since higher levels of argon laser energies cause greater lysis of red blood cells, comparable degrees of plaque ablation are observed under either blood medium.

Arteriosclerosis↗

Correlation of coronary angioscopic to angiographic findings in coronary artery disease.

An Olympus ultrathin fiberscope, 1.8 mm outer diameter, was inserted intraluminally into 11 stenoses of the left anterior descending and circumflex coronary arteries in 8 patients at coronary bypass surgery. Intraluminal views were obtained by coupling the angioscope to a color video camera and videotape recorder, and compared with preoperative coronary angiographic findings in right and left anterior oblique views. Atherosclerotic plaque was observed as yellow-white mass attached onto the luminal lining, which may be large enough to virtually obliterate the vascular lumen. Angioscopy provided a topographic view and cross-sectional picture of stenosis not observed by angiography. Single-plane angioscopic cross-sectional stenotic lumens correlated well (r = 0.90, p less than 0.001) with calculated angiographic luminal narrowings. However, with subtotal obstruction, lesion length must be assessed angiographically. Coronary angioscopy can be a useful adjunct to angiography by providing the added dimension of the true cross-sectional view of obstruction.

Coronary Angiography↗