Search PubMed⌕ Search

Biomedical subjects

R L Popp

Publications and source records attributed to R L Popp.

At least 55 records · Page 3Linked to original sources

Assignment of patients into the classification of cardiomyopathies.

The original classifications of the cardiomyopathies based on anatomic criteria from radiographic and necropsy studies, as well as hemodynamic criteria from clinical and catheterization data, have been supplemented in recent years by information from noninvasive techniques. Echocardiography, radionuclide methods, and ambulatory ECG, in particular, have facilitated the ethical screening of family members and those less symptomatic than patients on whom the original classification was based. These powerful methods show a broad spectrum of anatomy and ventricular physiology along the natural history of and within the traditional categories of the cardiomyopathies. They also provide data on the effect of ventricular loading conditions affecting a range of diastolic filling patterns. This review has attempted to point out the areas of overlap among and/or controversy about the categories that have led us to a feeling of frustration when trying to neatly classify individual patients. The addition of filling patterns from Doppler echocardiography and nuclear angiography to the standard methods has been reviewed and hopefully will lend more perspective to the range of physiology seen in these conditions. The categories of cardiomyopathy should not be seen as excluding patients with the newly recognized variations in anatomy and ventricular filling patterns. Rather, the classification provides a framework on which to build and expand our understanding of these important conditions.

Aging↗

Contributors of characteristic mitral flow velocity pattern in congestive heart failure--from clinical observations back to experimental validations.

Mitral flow velocity pattern in patients with left ventricular (LV) diastolic dysfunction usually includes decreased peak early diastolic filling velocity (E), slowed deceleration of the early diastolic filling wave and increased peak filling velocity at atrial contraction (A). However, the abnormal mitral flow velocity pattern can be normalized in the presence of concomitant congestive heart failure. In such cases E can be equal to or even higher than normal, its deceleration is normal or faster than normal value, and A can be normal or lower than normal value. Clinical observations in patients with severe heart failure showed that the mitral flow velocity pattern changes with vasodilating therapy, reflecting the changes in the left atrial (LA) to LV pressure difference rather than those in the absolute LA pressure or LV pressure alone. This was validated in the canine study in which levels of LV dysfunction were made by the injection of microspheres into the left coronary artery to study the interrelation among the mitral flow velocity pattern and LA and LV pressures. In this experiment, the changes in the mitral flow velocity pattern could not be explained by the changes in LA or LV pressure alone but was better explained by the changes in the LA to LV pressure difference. Not only LA-LV crossover pressure but also LA compliance seem to be important as determinants of LA pressure level in diastole. In addition to LV relaxation rate, incompleteness of relaxation, elastic recoil and LV passive elastic properties, extracardiac constraint is also considered to be an important determinant of the level of the LV diastolic pressure and hence of the mitral flow velocity pattern at least in the presence of congestive heart failure. Thus, mitral flow velocity pattern is determined by the interaction of LA and LV pressures, both of which are affected by chamber properties as well as loading conditions.

Animals↗

Hepatic venous flow assessed by transesophageal echocardiography.

Systemic venous flow patterns are easily assessed by transthoracic echocardiography for evaluation of right heart dynamics. However, the transthoracic approach cannot be used in patients undergoing thoracic surgery. The present study describes a method for obtaining hepatic venous flow velocity with transesophageal Doppler echocardiography. Twenty-nine patients were studied with transthoracic echocardiography just before cardiac surgery and with transesophageal echocardiography during surgery. Hepatic venous flow velocity recordings were obtained in 14 of 29 patients with the transthoracic and in all 29 with the transesophageal approach. Timing of flow pattern was similar with the two methods, but recordings obtained with transesophageal echocardiography were inverted compared with those obtained with transthoracic echocardiography as a result of the difference in probe location in relation to flow direction. The time-velocity integrals obtained with the two techniques did not differ significantly; for the transthoracic and transesophageal approaches, they were, respectively, 7.3 +/- 3.4 versus 5.7 +/- 4.4 for systolic flow; 1.0 +/- 1.0 versus 0.5 +/- 0.6 for end-systolic flow reversal; 4.7 +/- 2.3 versus 3.7 +/- 1.7 for diastolic flow; 2.0 +/- 1.8 versus 1.5 +/- 1.5 for atrial flow reversal and 1.9 +/- 1.0 versus 1.7 +/- 1.1 for systolic/diastolic ratio. In conclusion, hepatic venous flow values are obtained more frequently and with better quality by transesophageal than by transthoracic echocardiography. The flow patterns and velocity integrals are similar with both methods and previous experience with transthoracic echocardiography should be applicable to the transesophageal technique. Transesophageal Doppler echocardiography therefore has potential for studying right heart dynamics during anesthesia and surgery.

Anesthesia, General↗

Intravascular ultrasound imaging of angiographically normal coronary arteries: an in vivo comparison with quantitative angiography.

Intravascular ultrasound, a new technique for real-time two-dimensional visualization of arteries and veins, delineates vessel wall morphology and measures luminal dimensions. This imaging method has been validated with in vitro systems and in peripheral vessels, but there are few in vivo coronary artery studies. Twenty cardiac transplant recipients with no angiographic coronary artery disease were scanned with a 30-MHz intravascular ultrasound catheter from the left main coronary ostium to the mid-left anterior descending coronary artery. Simultaneous angiographic measurements were performed at 76 sites. Ultrasound end-diastolic diameters in two perpendicular axes were 3.8 +/- 0.9 and 3.9 +/- 0.6 mm, respectively, and mean diameter derived from an area determined by planimetry was 3.9 +/- 0.9 mm. Angiographic coronary artery diameters measured with a computer-assisted edge detection system perpendicular to the long axis of the vessel and to the long axis of the catheter were 3.4 +/- 0.8 and 3.6 +/- 0.8 mm, respectively. Luminal diameters measured with the two imaging systems correlated closely, with an r value of 0.86 when ultrasound was compared with the angiographic diameter measured perpendicular to the vessel and 0.88 when compared with the angiographic diameter measured perpendicular to the imaging catheter. Eighty-three percent of the ultrasound-measured diameters were above the line of identity when compared with the simultaneous angiographic measurement. The more the imaging catheter deviated from the long axis of the vessel, the greater was the discrepancy between the ultrasound and angiographic measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography↗

Abnormal right heart filling after cardiac surgery: time course and mechanisms.

OBJECTIVE: To study the time course and underlying mechanisms of right heart filling after cardiac surgery. DESIGN: A prospective observational study of adult patients undergoing cardiac surgery. SETTING: Echocardiography laboratory of the Stanford University Medical Center. PATIENTS: Twenty six patients (mean age 54.9) undergoing cardiac surgery were studied before and two days, one week, six weeks, and six months after cardiac surgery. MAIN OUTCOME MEASURES: Flow in the hepatic veins and superior vena cava, tricuspid and mitral annulus motion, signs of tricuspid regurgitation, and right ventricular size were assessed by echocardiography. RESULTS: Right heart filling, expressed as the ratio of systolic to diastolic forward flow Doppler velocity integrals in the superior vena cava and by tricuspid annulus motion, decreased in parallel from before surgery baseline values of 3.5 (SD 3.1) and 21.9 (3.4) mm, respectively to 0.2 (0.1) and 8.1 (2.3) mm two days after operation. A gradual increase towards baseline values was noted after six months, to 1.4 (1.3) and 15.1 (2.3) mm respectively; however, these values were still significantly less than those before operation. Similar changes were seen in the hepatic venous flow pattern. The decrease in total tricuspid annulus motion was most pronounced in its lateral segment and the atrial component of the tricuspid annulus motion showed similar changes. CONCLUSIONS: The pronounced decrease in tricuspid annulus motion during the early postoperative period suggests right atrial and right ventricular dysfunction as mechanisms responsible for the early changes seen. The progressive return to a normal venous filling pattern and the partial recovery of annular motion six months after operation further support the influence of the above mechanisms, as well as their resolution with time. The persistent flow abnormalities and compromised motion of the free aspects of the tricuspid annulus, however, suggest long term tethering of the right heart wall.

Adult↗

Late pulmonary sequelae of bronchopulmonary dysplasia.

BACKGROUND: Bronchopulmonary dysplasia is a chronic lung disease that often develops after mechanical ventilation in prematurely born infants with respiratory failure. It has become the most common form of chronic lung disease in infants in the United States. The long-term outcome for infants with bronchopulmonary dysplasia has not been determined. METHODS: We studied the pulmonary function of 26 adolescents and young adults, born between 1964 and 1973, who had bronchopulmonary dysplasia in infancy. We compared the results with those in two control groups: 26 age-matched adolescents and young adults of similar birth weight and gestational age who had not undergone mechanical ventilation, and 53 age-matched normal subjects. RESULTS: Sixty-eight percent of the subjects with bronchopulmonary dysplasia in infancy (17 of the 25 tested) had airway obstruction, including decreases in forced expiratory volume in one second, forced expiratory flow between 25 and 75 percent of vital capacity, and maximal expiratory flow velocity at 50 percent of vital capacity, as compared with both control groups (P less than 0.0001 for all comparisons). Twenty-four percent of the subjects with bronchopulmonary dysplasia in infancy had fixed airway obstruction, and 52 percent had reactive airway disease, as indicated by their responses to the administration of methacholine or a bronchodilator. Hyperinflation (an increased ratio of residual volume to total lung capacity) was more frequent in the subjects with a history of bronchopulmonary dysplasia than in either the matched cohort (P less than 0.0006) or the normal controls (P less than 0.0004). Six of the subjects who had bronchopulmonary dysplasia in infancy had severe pulmonary dysfunction or current symptoms of respiratory difficulty. CONCLUSIONS: Most adolescents and young adults who had bronchopulmonary dysplasia in infancy have some degree of pulmonary dysfunction, consisting of airway obstruction, airway hyperreactivity, and hyperinflation. The clinical consequences of this dysfunction are not known.

Adolescent↗

Autocorrelation length of normal and myopathic human myocardium measured by acoustic microscopy: implications for clinical ultrasonic tissue characterization.

The pattern of acoustic speckle present in ultrasonic images of tissue may be affected by pathological changes in the tissue. To investigate the possibility for such an effect in dilated cardiomyopathy, we examined acoustic micrographs of frozen sections of normal (autopsy) and myopathic (transplant recipient) human myocardium. The resulting images were digitized, and the major axis autocorrelation length calculated for each image. For the normal specimens (n = 75, four patients), the mean autocorrelation length was 37 +/- 18 microns, with the maximum value of 92 microns. The myopathic specimens (n = 64, four patients) had a mean of 52 +/- 19 microns, with a maximum of 100 microns. We conclude that the changes in structure between normal and myopathic myocardium are significant (p less than 0.001), but on so small a scale in relation to the wave length of clinical ultrasound that there will only be changes in the intensity of the backscattered signal, not the pattern of speckle.

Acoustics↗

Effects of nitroprusside on transmitral flow velocity patterns in extreme heart failure: a combined hemodynamic and Doppler echocardiographic study of varying loading conditions.

To explore the mechanisms of change of left ventricular diastolic filling associated with preload and afterload reduction, the influence of nitroprusside on the transmitral flow velocity pattern, pulmonary capillary wedge pressure and left ventricular pressure interaction was studied in 11 patients with end-stage heart failure. Pulsed Doppler echocardiographic recordings of mitral inflow were obtained with simultaneous high fidelity left ventricular and phase-corrected pulmonary capillary wedge pressure recordings before and during levels of nitroprusside infusion. With nitroprusside, left ventricular systolic and end-diastolic pressures decreased by 14% and 41% (p less than 0.05, p less than 0.05), respectively, and cardiac output increased by 67% (p less than 0.05). The pulmonary capillary wedge-left ventricular crossover pressure decreased by 41% (p less than 0.05), but the time constant of isovolumetric left ventricular pressure decrease T was insignificantly changed. Isovolumetric relaxation time and acceleration and deceleration times of the early diastolic filling wave were significantly prolonged with nitroprusside infusion (p less than 0.05, p less than 0.05 and p less than 0.05, respectively). Peak early diastolic filling velocity was maintained (65 +/- 11 to 62 +/- 13 cm/s, p = NS) in spite of the decreased absolute crossover pressure. Changes in peak early diastolic filling velocity correlated weakly with changes in the crossover pressure (r = 0.48, p less than 0.05) and correlated better with the crossover to left ventricular minimal pressure difference (r = 0.78, p less than 0.05). Peak early diastolic filling velocity appears to be most affected by the early diastolic pulmonary capillary wedge to left ventricular pressure difference rather than the absolute pulmonary capillary wedge pressure. The lack of peak flow velocity change during nitroprusside infusion could be explained by either the associated decrease in left ventricular minimal pressure or downward shift of left ventricular diastolic pressure by the same amount as the decrease in pulmonary capillary wedge pressure. This may reflect a reduction of external constraint to ventricular distensibility produced by a reduction in filling volume in patients with a markedly dilated ventricle. Thus, a prolonged early diastolic filling period and preserved peak early diastolic filling velocity in spite of decreased left ventricular filling pressure and constant relaxation rate are associated with the beneficial effects of nitroprusside on left ventricular function in patients with severe congestive heart failure.

Blood Flow Velocity↗

Transesophageal echocardiography and its potential for esophageal damage.

The purpose of this study was to determine whether the pressure produced by contact between a transesophageal echocardiography (TEE) probe and the esophagus was sufficient to cause esophageal damage. The authors studied the effects of sustained contact and associated surface pressure on the esophagus by a TEE probe in anesthetized dogs and humans. Contact pressure between the tip of the probe and the esophageal wall in dogs was measured using a previously described flat balloon of Silastic fitted to the end of a TEE probe and the recording system calibrated with a mercury manometer. In the dog studies, the probe was inserted, maximally flexed, and its position fixed for 4, 6, 8, and 12 h. The maximum surface pressure generated by contact between a probe and the esophageal wall was 10 mmHg. Subsequent pathologic studies failed to reveal either gross or microscopic evidence of tissue damage. The same system was used in short-term patient studies with the surface contact pressure transducer connected to a Camino Catheter 420 Digital Pressure Monitor. In five of six patients contact pressure was less than 17 mmHg despite maximal rotation of the TEE controls. However, one of the six patients developed very high contact pressure, up to 60 mmHg, between the probe and the esophagus. This patient had no history of esophageal disease but did have intrathoracic pathology.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Mildly dilated congestive cardiomyopathy. Use of prospective diagnostic criteria and description of the clinical course without heart transplantation.

Prognosis in classically described dilated congestive cardiomyopathy has been reported to be related to ventricular size. Mildly dilated congestive cardiomyopathy (MDCM) has been defined as end-stage heart failure of unknown etiology (New York Heart Association class IV, left ventricular ejection fraction less than 30%), occurring with neither typical hemodynamic signs of restrictive myopathy nor significant ventricular dilatation (less than 15% above normal range). The present study includes follow-up in 12 nontransplant patients. In the first 4 months after diagnosis, two patients improved and are living, and two showed cardiac dilation and clinical deterioration and died. Six of the remaining eight with persistent MDCM died (four with intractable heart failure and two, sudden deaths) without change in ventricular size before death, despite medical therapy over 20 +/- 8 months. Eight comparable transplanted patients with persistent MDCM demonstrated improved total survival by life table analysis (p less than 0.05). A family history of congestive cardiomyopathy was found in nine of 16 patients (56%) with persistent MDCM. Nontransplant patients were older (p less than 0.02), but other findings were similar in the two groups. Endomyocardial biopsies available in 14 of 16 cases showed little or no myofibrillar loss in spite of severe hemodynamic impairment. The degree of myofibrillar loss did not correlate with hemodynamic parameters but showed good correlation with left ventricular size, that is, five of six patients with no myofibrillar loss had normal ventricular size, whereas all eight patients with mild myofibrillar loss had mild cardiomegaly (p less than 0.002). Our current experience suggests a somewhat variable but negative prognosis after prospective diagnosis of MDCM, with poor survival in patients with persistence of the original diagnostic features during follow-up. Preservation of heart size in MDCM is probably related to lack of significant myofibrillar loss. Thus, irrespective of heart size or myofibrillar preservation on biopsy, heart transplantation should be strongly considered in MDCM if signs of severe cardiac dysfunction persist despite therapy.

Adult↗

Serial measurement of integrated ultrasonic backscatter in human cardiac allografts for the recognition of acute rejection.

Cyclic variation of integrated ultrasonic backscatter (IB) was noninvasively measured in the septum and left ventricular posterior wall using a quantitative IB imaging system to assess the alterations in the acoustic properties of myocardium associated with acute cardiac allograft rejection. The study population consisted of 23 cardiac allograft recipients and 18 normal subjects. In each cardiac allograft recipient, one to eight (mean, four) IB studies were performed, each within 24 hours of right ventricular endomyocardial biopsy performed for rejection surveillance. The magnitude of the cyclic variation of IB in the posterior wall was 5.9 +/- 0.9 dB in normal subjects and 6.2 +/- 1.3 dB in the cardiac allograft recipients without previous or current histological evidence of acute rejection (n = 17, p = NS vs. normal subjects). The magnitude of cyclic variation of IB in the septum was 4.8 +/- 1.1 dB in normal subjects and 3.8 +/- 2.0 dB in the cardiac allograft recipients (n = 15, p = NS vs. normal subjects). A significant decrease in the septal IB measure was observed in cardiac allograft recipients with left ventricular hypertrophy (wall thickness of at least 13 mm) (2.6 +/- 1.7 dB, n = 8, p less than 0.05 vs. normal subjects). IB studies were done before and during moderate acute rejection in 11 recipients (14 episodes). During moderate acute cardiac rejection, the magnitude of the cyclic variation in IB decreased from 6.7 +/- 1.3 to 5.1 +/- 1.4 dB in the posterior wall (n = 14, p less than 0.05) and from 4.2 +/- 2.1 dB to 2.9 +/- 1.8 dB in the septum (n = 12, p less than 0.05). These data suggest 1) the magnitude of the cyclic variation in IB of the septum is different in cardiac allografts with cardiac hypertrophy and normal subjects, possibly reflecting regionally depressed myocardial contractile performance and 2) acute cardiac rejection in humans is accompanied by an alteration in the acoustic properties of the myocardium. This change is detectable by serial measurement of the magnitude of the cyclic variation in IB, both in the septum and in the posterior wall.

Echocardiography↗

Left ventricular diastolic function. Doppler echocardiographic changes soon after cardiac transplantation.

In acute cardiac rejection, left ventricular diastolic function is altered, and a restrictive ventricular filling pattern occurs. Doppler echocardiographic indexes of mitral inflow have been proposed as sensitive markers of the rejection process. As rejection progresses, the restrictive ventricular filling pattern is reflected by a shortening of isovolumic relaxation time and mitral valve pressure half-time and by an increase in early transmitral filling velocity. Diastolic function is also compromised in the nonrejecting cardiac transplant recipient during the early postoperative period. This study examined the progression in Doppler-derived mitral filling indexes in 25 recent cardiac transplant recipients who demonstrated no histological evidence of transplant rejection. Isovolumic relaxation time, mitral valve pressure half-time, and early transmitral filling velocity were measured at postoperative weeks 1, 2, 4, and 6 on the day that surveillance right ventricular endomyocardial biopsies were performed. The initial indexes were comparable to previously described restrictive parameters and over the 6-week study period evolved into a nonrestrictive filling pattern. This evolution reflects a progressive improvement in postoperative diastolic function and a decrease in left heart filling pressures. None of the evaluated clinical characteristics, including preoperative pulmonary pressures, total ischemic time of the transplanted heart, cardiopulmonary bypass time, and age of the donor heart, correlated with this process. Given the increasing use of Doppler echocardiography as a means of screening for transplant rejection, it is important to have a thorough understanding of normal postoperative changes in left ventricular diastolic function.

Adult↗

Lessons from in vitro models of small, irregular, multiple and tunnel-like stenoses relevant to clinical stenoses of valves and small vessels.

This review examines data on the accuracy of the simplified Bernoulli equation for quantitation of pressure drops across small, irregular, multiple and tunnel-like stenoses. This information is drawn from in vitro models of such cardiovascular stenoses and explores the limits of this simplification as they affect accuracy in special situations. Within the physiologic range, discrete small and irregular stenoses present no problems for the measurement of pressure drops using the simplified Bernoulli equation. Multiple side by side orifices of different dimension also give reasonable data using this approach. Tunnel-like stenoses of very small diameter and finite length produce underestimation of the true pressure drop through the stenosis when the simplified Bernouli equation is used. This underestimation is primarily due to neglect of the energy consumed by viscous friction in this situation. These considerations are especially pertinent to the problem of measuring pressure gradients across coronary vessels to assess their clinical significance as well as the adequacy of angioplasty and other intravascular interventional techniques. Because this area needs further exploration, some discussion of in vitro models as such as included.

Blood Flow Velocity↗

Ultrasonic tissue characterization with a real time integrated backscatter imaging system in normal and aging human hearts.

Experimental studies have shown that variation in the magnitude of integrated ultrasonic backscatter during the cardiac cycle represents acoustic properties of myocardium that are affected by pathologic processes; however, there are few clinical studies using integrated backscatter. Forty subjects without cardiovascular disease (aged 22 to 71 years, mean 41) were studied with use of a new M-mode format integrated backscatter imaging system to characterize the range of cyclic variation of integrated backscatter in normal subjects. Cyclic variation in integrated backscatter was noted in both the septum and the posterior wall in all subjects. The magnitude of the cyclic variation of integrated backscatter and the interval from the onset of the QRS wave of the electrocardiogram to the minimal integrated backscatter value were measured using an area of interest of variable size for integrated backscatter sampling and a software resident in the ultrasound scanner. The magnitude of cyclic variation was larger for the posterior wall than for the septum (6.3 +/- 0.8 versus 4.9 +/- 1.3 dB, p less than 0.01). The interval to the minimal integrated backscatter value was 328 +/- 58 ms for the septum and 348 +/- 42 ms for the posterior wall (p = NS). There was a weak correlation between the magnitude of cyclic variation of integrated backscatter and subject age for the posterior wall (r = -0.47, p less than 0.01), but this was not significant for the septum (r = -0.21) (partially because of inability to exclude specular septal echoes) and septal endocardium.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗