Forced random noise resistance determination in childhood asthma.

The forced random noise method for measuring respiratory resistance was studied in terms of reproducibility and correlation with spirometry and flow volumes in 30 older children (four to 17 years) with asthma and in 16 infants and children below three years of age. In the 30 older children, the mean value of individual coefficient of variations for three repeated measurements was 7.4 percent. Resistance parameters correlated well with spirometric parameters with all but three correlation coefficients greater than 0.7. In 20 older asthmatic patients, 180 micrograms albuterol caused a significant reduction in resistance in 11 subjects. At the same time, FEV1 increased significantly in nine subjects but showed a paradoxic decrease in five. This paradoxic response is attributed to complex reflexes caused by the maximum inspiration and forced expiration and did not occur with resistance measurements. This method requires little subject cooperation, and therefore, is well suited for infants and children.

Adolescent↗

Genesis of QRS in the ruminant: graphic simulation.

Graphic simulation of ventricular activation for a typical ruminant with complete endocardial-epicardial penetration of Purkinje's fibers was performed. Voltages recorded from points on the torso simulating electrodes V10 and aVF were predicted. These compared favorably in amplitudes and durations with voltages actually recorded from typical ruminants.

Animals↗

Effects of 0.1 ppm nitrogen dioxide on airways of normal and asthmatic subjects.

It has been reported (J. Clin. Invest. 57: 301-307, 1976) that inhalation of nitrogen dioxide (NO2) will enhance the bronchial reactivity of asthmatics. This study was designed to evaluate the respiratory effect of a 1-h exposure of normal subjects and of atopic asthmatics to 0.1 parts per million (ppm) NO2. Fifteen normal and 15 asthmatic subjects were exposed to air and to NO2 in a randomized double-blind crossover design. Exposure to either atmosphere was bracketed by bronchial inhalation challenge using aerosolized metacholine chloride solutions. Plethysmographic measurements of specific airway resistance (sRaw) and the forced random noise impedance spectrum (5-30 Hz) were obtained immediately after each methacholine dose. Following acute exposure to NO2, there was a slight but not significant increase in mean base-line sRaw in both normals and asthmatics. The overall base-line resistive properties of the respiratory system determined by forced random noise excitation were not significantly affected by NO2 inhalation either. Finally, there was no change in bronchial response to methacholine challenge in either group. These findings indicate that 0.1 ppm NO2 exposure for 1 h without exercise had no demonstrable airways effects in either young atopic asthmatics with mild disease or young normal subjects.

Adolescent↗

Pulmonary impedance in dogs measured by forced random noise with a retrograde catheter.

Retrograde catheter and forced random noise techniques were combined to study the distribution of resistance and compliance in dogs following the inhalation of aerosols containing 2.5 and 5.0 mg/ml of histamine. Mean base-line peripheral resistance was 0.367 cmH2O . l-1 . s, agreeing with previous estimates. After correction for the endotracheal tube, the mean central airway resistance was 0.040 cmH2O . l-1 . s, considerably lower than previous estimates. This discrepancy was attributed to an overcorrection for the endotracheal tube resistance. The lower histamine dose caused a substantial increase in peripheral resistance, a relatively small increase in central resistance, and substantial decreases in total and peripheral compliance. After the higher histamine dose, changes in peripheral resistance and both compliances were similar to those obtained with the lower dose; however, the increase in central resistance was much larger than at the lower dose. The difference between total and peripheral compliance yielded estimates of airway compliance of 0.00306 l/cmH2O before and 0.00104 l/cmH2O after 2.5 mg/ml of histamine.

Aerosols↗

Forced noise mechanical parameters during inspiration and expiration.

Using the forced random noise technique we collected three 5-min records of pressure and flow signals in five clinically normal nonsmoking adults. Each recording was analyzed to obtain respiratory impedance spectra from data obtained during continuous sampling, midinspiration, and midexpiration. Estimates of respiratory resistance, inertance, and compliance were obtained by regression analysis on each impedance spectrum. Mean expiratory resistance and compliance were significantly (P less than 0.01) greater than corresponding mean inspiratory values, while mean expiratory inertance was significantly (P less than 0.001) less than the mean inspiratory value. Parameters from continuous sampling agreed fairly well with inspiratory resistance and inertance and with expiratory compliance. The coefficient of variation of parameters from continuous data were similar to, or smaller than, those from inspiratory or expiratory data. Thus continuous sampling appears to be an acceptable approach for collecting random noise data.

Airway Resistance↗

Correlation of airway resistance with forced random noise resistance parameters.

The correlation between airway resistance (Raw) measured in a plethysmograph and three respiratory resistance parameters measured by forced random noise was evaluated. Forced random noise resistance parameters were the average resistance between 5 and 9 hz (R5-9), the average resistance between 20 and 24 Hz (R20-24), and the extrapolated resistance at 1 Hz (R1). We studied 22 healthy, nonsmoking subjects, 10 of whom had a history suggesting childhood asthma. Serial measurements were made after inhalation of aerosols containing increasing concentrations of methacholine of aerosols containing increasing concentrations of methacholine to obtain data in various stages of bronchoconstriction. There was a broad range of responsiveness to methacholine; the ratio of the peak to base-line values of Raw ranged from 1.1 to 6.3. R1, R5-9, and R20-24 were related to Raw by linear regression analysis. R1 and R5-9 showed excellent correlation with Raw (r = 093 and 4=0.91, respectively); R20-24 showed much poorer correlation (r = 0.62). The slopes of the regression equations for R1 and R5-9 were 1.56 and 0.51, respectively; thus neither provided an exact measure of Raw. The data appear to be consistent with a model in which most of the methacholine-induced increase in resistance occurred in the peripheral airways and only a small fraction in the central airway.

Adolescent↗

Direct dynamic measurements of tracheal diameter.

Methods of monitoring airway caliber as an indicator of bronchomuscular tone have been indirect, static, and invasive. A diameter transducer has been developed the static and dynamic characteristics of which indicate that it should overcome some methodological problems. The catheter-mounted spring-loaded braces of the transducer track the motion of the airway wall, which is reflected in the output changes of a linear-variable transformer. The range of the transducer was 5.3-24.3 mm. The amplitude response was flat up to 8 Hz, and the phase difference between the forcing signal and the response of the gauge was 0 degrees up to 8 Hz. The minimum specific compliance was 0.15 cmH2O-1, an order of magnitude larger than the specific compliance of isolated trachea, indicating that the airway was not significantly loaded by the transducer. In vivo studies in ventilated dogs revealed tidal changes in tracheal diameter and marked constriction during apnea. Bilateral vagotomy increased diameter up to 20%, and vagal stimulation decreased diameter as much as 30% below postvagotomy levels. It appears that this transducer is suitable for measuring resting diameter, tidal changes in diameter, and changes in diameter induced by alteration in bronchomotor tone.

Animals↗

Time-constant histograms from the forced expired volume signal.

The forced expired volume signal was analyzed using a parallel compartment model in which each compartment emptied exponentially. With this model the forced expired volume signal was represented by a histogram showing the fraction of the vital capacity as a functional of compartmental time constants. We developed an algorithm to compute this histogram from the volume signal. The algorithm used the least-squares criterion function with both smoothness and nonnegativity constraints. In a stimulation study reasonable histograms were obtained even in the presence of realistic random error. Three dependent forced expired volume signals from 16 subjects were analyzed, and the histograms were reproducible. Most histograms were bimodal with fast time constants of 0.12-0.55 s and slow time constants of 1.3-2.7 s. In all normal subjects and patients with restrictive disease more than 75% of the vital capacity was in the fast time-constant mode. Subjects with obstructive disease had more than 40% of the vital capacity in the slow time-constant mode.

Adult↗

Forced oscillatory resistance and compliance parameters following pneumonectomy in beagle dogs.

Forced oscillatory resistance (RFO) and compliance (CFO) were measured in 3 groups of adult beagle dogs. Group I (n = 12) had undergone a left pneumonectomy at 6-10 weeks of age; group II (n = 11) underwent a similar procedure at 1 year of age; and group III (n = 8) served as unoperated controls. The mean value of RFO for group II was significantly higher than corresponding values for groups I and III. Similarly, the mean value of CFO was significantly lower for group II. Mean values for RFO and CFO between groups I and III were not statistically different. When RFO and CFO were normalized by functional residual capacity, mean values for all three groups were similar. However, when RFO and CFO were normalized by body weight, mean values for groups I and II were significantly different from those of group III. These findings cannot be explained directly by postoperative hyperinflation of the remaining lung. They suggest that there is an adaptive change in the mechanical characteristics of the remaining lung following pneumonectomy and that the degree of adaptation varies with the age of the animal undergoing resection.

Adaptation, Physiological↗

Dynamic respiratory mechanics in intact anesthetized hamsters.

A system for measuring parameters of ventilation and respiratory mechanics in intact anesthetized hamsters was developed. Means +/- SD of five weekly measurements in eight hamsters were 0.68 +/- 0.09 ml for tidal volume, 45 +/- 14 breaths.min-1 for respiratory frequency, 29.3 +/- 10.4 ml.min-1 for minute ventilation, 0.301 +/- 0.080 ml.cmH2O-1 for dynamic compliance, 0.435 +/- 0.151 cmH2O.ml-1.s for inspiratory resistance, 0.311 +/- 0.101 cmH2O.ml-1.s for expiratory resistance, and 0.334 +/- 0.096 cmH2O.ml-1.s for average resistance. The standard deviations of five consecutive measurements of these parameters on the same day were typically 10% of the corresponding mean values suggesting that acute changes as small as 10% can be detected in a study of similar size. The corresponding value for five single measurements on different days at weekly intervals was 30%. We believe that this system yields reasonable and repeatable measurements, and, because it is atraumatic, it can be used in chronic studies of diseases in hamsters and other small animals.

Airway Resistance↗