An in vitro and clinical comparison of corneal storage with chondroitin sulfate corneal storage medium with and without dextran.

The safety and efficacy of 1% dextran in Chondroitin Sulfate Corneal Storage Medium (CSM) in reducing corneal swelling after 4 degrees C storage was assessed in a corneal endothelial cell culture system. No difference was found in 3H-thymidine incorporation by cells incubated in either CSM-dextran medium or CSM medium alone. Subsequently, 21 pairs of corneas, stored in either CSM or CSM-dextran from 30 to 112 hours, were transplanted into 42 eyes of 42 patients, paired by diagnostic group and procedure. All CSM grafts and 19 of 21 CSM-dextran grafts were clear at 4 months with no primary donor failures in either group. Intraoperative corneal thickness was significantly greater in the CSM group (0.82 +/- 0.07 mm) than the CSM-dextran group (0.76 +/- 0.06 mm); however, the two groups did not differ thereafter. No differences in all endothelial morphometric parameters were noted between the two groups pre- and postoperatively. Average endothelial cell loss by 4 months was 13.0 +/- 16.4% for the CSM group and 16.4 +/- 15.5% for the CSM-dextran group. The addition of dextran to CSM medium results in significant intraoperative corneal thinning without adversely affecting endothelial DNA synthesis in vitro and endothelial survival in vivo.

Adult↗

Multifocal intraocular lenses.

Current multifocal intraocular lens designs incorporate refractive or diffractive optical principles to achieve increased depth of focus. Information about four basic design concepts is presented. Early clinical results with two of these, the IOLAB Nuvue two-zone refractive multifocal and the 3M diffractive multifocal, are summarized.

Clinical Trials as Topic↗

Lysis of vitreous strands with neodymium: YAG laser.

Eighteen eyes with vitreous strands adherent to the corneoscleral wounds of previous cataract surgery were treated with neodymium: YAG laser to lyse those strands. Twelve eyes were treated for management of cystoid macular edema (CME group); six eyes were treated for prophylaxis of possible CME (prophylactic group). In the CME group, visual acuity improved two or more lines in nine eyes (75.0%), and seven eyes had a post laser visual acuity of 0.5 or better (One eye had a pre-treatment visual acuity of 0.5 or better). In the prophylactic group, visual acuity was either maintained at the pre-treatment visual acuity of 0.5 or better. In the prophylactic group, visual acuity was either maintained at the pre-treatment level or improved in five eyes (83.3%) 18 months later following laser treatment. This procedure was complicated by retinal detachment in one case and the elevation of intraocular pressure over 10 mmHg in another case.

Adult↗

Advances in corneal preservation.

The functional status of the endothelium and sustained corneal deturgescence after corneal preservation are of great clinical importance and have been primary goals in the development of corneal storage media. In our investigational studies we have specifically addressed the improvement of the quality of donor tissue after 4 degrees C storage, the extension of corneal preservation time, the enhancement of corneal wound healing, and the reduction of the normal progressive loss of endothelial cells postkeratoplasty. Specifically we have developed in vitro HCE cell and epithelial cell culture models that can accurately reflect the response of human corneal tissue in vivo. These models have been utilized to study the effects of growth factors and medium components in relation to their biocompatibility and efficacy in the development of improved corneal preservation solutions. Our laboratory investigated in vitro conditions that allowed human corneal endothelium to shift from a nonproliferative state, in which they remain viable and metabolically active, to a proliferative, mitotically active state. Isolation techniques developed in our laboratory have enabled the establishment of primary and subsequent subcultures of human corneal endothelium that retain the attributes of native endothelium. These in vitro conditions maintain HCE cells in a proliferative state, actively undergoing mitosis. A quantitative bioassay has been developed to determine the effects of various test medium in the stimulation or inhibition of DNA synthesis. In attempting to learn more about the events that occur during in vitro endothelial cell isolation, cell reattachment, extracellular matrix interaction and migrating during subculture, SEM was done on isolated HCE cells incubated in CSM. These studies suggest that the components of the extracellular matrix modulate the growth response of HCE cells, and play a role in regulating proliferation and migration. These observations are important in view of the fact that anterior chamber environment limits cell regeneration of the endothelium, and supports wound healing via cell migration. In vivo, it is the complex interaction of the HCE cell and the extracellular matrix that signal the cell to respond to cell loss in this manner. As our knowledge of human corneal endothelium has increased so has our anticipation of developing the "optimum" medium. Thus additional components have been added to this basic medium to address specific complications encountered with 4 degrees C corneal preservation. Antioxidants, additional energy sources, and other nutritive substrates have been used to supplement and further define a chondroitin sulfate-based medium. These changes have been a part of our new awareness that, even at 4 degrees C, the cornea is metabolically active.(ABSTRACT TRUNCATED AT 400 WORDS)

Cells, Cultured↗

Eye banking: the Minnesota experience.

We present a brief report on the activities of the Minnesota Lions Eye Bank. This eye bank receives and supplies tissue to several midwestern states. In addition, it plays a vital role in providing tissue for research and training at the University of Minnesota. In association with the Department of Ophthalmology, the eye bank is also actively involved in the research and development of various corneal preservation systems. Included below is information relative to procedures used in the eye bank for the selection and collection of donor material; the decontamination, preparation, and storage of corneas; cost of eye bank services; and staff coverage. Also included is some data on the number of eyes received and processed and the eventual uses of the tissues, during the last ten years.

Corneal Transplantation↗

Anatomic study of transsclerally sutured intraocular lens implantation.

We used 21 cadaver eyes to study transsclerally sutured, ciliary sulcus-fixated intraocular lens implantation. Results showed that transscleral sutures should exit the sclera less than 1 mm posterior to the corneoscleral limbus for true ciliary sulcus fixation. The relationship of the ciliary sulcus to the overlying posterior surgical limbus differed in the vertical and horizontal meridians; needles that pierced the ciliary sulcus after being passed perpendicularly through the sclera entered the sclera 0.83 +/- 0.1 mm posterior to the posterior surgical limbus in the vertical meridians and 0.46 +/- 0.1 mm in the horizontal meridians. The major arterial circle of the iris (located in the ciliary body) was avoided as was the entire ciliary body during proper ciliary sulcus fixation. A one-piece, all polymethylmethacrylate, 10-degree vaulted, 13.5-mm haptic spread intraocular lens provides excellent optic centration and haptic stabilization when the haptic structure is placed at the greatest haptic spread and one transscleral suture pass per haptic is made.

Anterior Chamber↗

Retinal detachment after neodymium:YAG laser posterior capsulotomy.

We reviewed the records of 397 patients who had undergone Nd:YAG laser posterior capsulotomy between July 1983 and August 1988. Of the 366 eyes that had been followed up for three months or more, 13 (3.6%) developed a retinal detachment after capsulotomy; of these 13 detachments, 11 (84.6%) occurred within the first year. The combination of male gender with axial myopia (greater than or equal to 25.00 mm), a history of lattice degeneration, or a history of retinal detachment in the fellow eye was a significant risk factor for the development of retinal detachment after YAG capsulotomy.

Cataract Extraction↗

Neodymium:YAG laser zonulysis for treatment of lens subluxation.

Nine eyes with lens subluxation in seven patients (6 patients with Marfan's syndrome, 1 with idiopathic lens subluxation) were treated by neodymium:YAG (Nd:YAG) laser zonulysis. The procedure uses an Nd:YAG laser to lyse the zonules to obtain a clear aphakic visual axis. Pretreatment best-corrected visual acuity was 20/60 or worse in eight eyes (6 eyes less than or equal to 20/200). Movement of the crystalline lens was achieved after zonulysis in all cases (100%), and a clear aphakic visual axis, sufficient to maintain aphakic correction without diplopia or glare, was obtained in eight eyes (88.9%). The procedure was combined with optical iridotomy in three cases (33.3%). Five cases (55.6%) required more than one zonulysis treatment. Visual acuity improved two or more Snellen lines in all but one eye (7 eyes greater than or equal to 20/60). Four cases had complications which included: increased intraocular pressure (IOP), mild iritis, recurrent migration of the lens into the visual axis, and crystalline lens damage. The final two complications necessitated eventual surgical removal of the lens. These results suggest that Nd:YAG laser zonulysis may be of benefit as an alternative treatment modality for selected patients with lens subluxation.

Adult↗

Visual results following vitreous loss and primary lens implantation.

Implantation of an intraocular lens following vitreous loss at cataract surgery is a controversial decision. To address this issue, we retrospectively identified all cases performed at the University of Minnesota in the last three years that had either a posterior or an anterior chamber lens placed following anterior vitrectomy. Twenty patients had a posterior chamber lens implant; 14 had follow-up longer than six months. All these patients achieved 20/40 or better visual acuity, although one patient had a retinal detachment. Of the six patients with an anterior chamber lens implant, four achieved 20/40 or better acuity and two achieved 20/50 acuity with follow-up of six months; one patient had a retinal detachment. This review demonstrates that with a meticulous anterior vitrectomy, good visual results can be achieved, although the risk of retinal detachment is higher than in uncomplicated cases.

Cataract Extraction↗

Epikeratophakia: technique modifications and visual results compared to the national study.

Twenty-eight epikeratophakia procedures have been performed at the University of Minnesota since December 1985. This report describes several technique modifications and compares the refractive and visual outcome of these cases with the national results. There have been 17 aphakic cases (13 adult and four pediatric), seven myopic procedures, and four keratoconus cases. Of the adult aphakic cases, 80% were within 3 diopters of emmetropia at six months, with four cases showing an undercorrection. In the myopic group, five cases showed an overcorrection at six months and all patients were within two Snellen lines or better than their preoperative best corrected vision. The major complications included one graft removal for failure to epithelialize, an interface hematoma, and a severe overcorrection to +9.37 diopters in a myopic patient. A no-keratectomy technique was used in the aphakic and myopic groups. A variation on centering the Hessburg-Barron trephine and removing the epithelium was performed and allowed for more accurate trephine placement.

Adult↗

Intraocular lens implantation in phakic rabbit eyes.

Three sizes (13.5 mm, 17.5 mm, and 18.5 mm) of open loop, one piece, poly(methyl methacrylate) anterior chamber intraocular lenses (IOLs) were implanted in 12 phakic rabbit eyes to evaluate the effect of the IOL on the crystalline lens and the anterior chamber. Six eyes were used as a control group. Minimum follow-up was four weeks. All the IOLs touched the crystalline lenses, and on the first postoperative day, round subcapsular lens opacities were found in all eyes in the area of IOL contact. The lens opacities became more dense with time. Only one eye in the control group showed a subcapsular opacity, which was linear rather than round. Anterior chamber inflammation was 1+ to 2+ in ten eyes (80%) in the IOL group during the first and second weeks, whereas minimal inflammatory changes occurred in the control group. These results suggest that with current IOL technology, IOL insertion in the phakic eye to correct refractive errors results in a high incidence of cataract if IOL-to-lens touch occurs.

Animals↗

Analysis of astigmatic keratotomy.

Eighty-two keratotomy procedures were performed for both idiopathic and postsurgical astigmatism or myopic astigmatism and analyzed for efficacy using vector and linear regression analysis. Delta keratometry values (delta K) were computed for each case as delta K in the desired axis of effect using vector analysis. Six different procedures were compared including both intersecting and nonintersecting trapezoidal keratotomy, relaxing incisions with compression sutures, T cuts with radial keratotomy, T cuts alone, and RK with elliptical optical zones. Our results showed that the greatest shifts occurred in the trapezoidal groups, whereas the most predictable effects occurred in the relaxing incision/compression suture group. Astigmatic keratotomy is capable of producing large shifts in corneal astigmatism; however, the accuracy of these procedures remains highly variable.

Adult↗

Transcleral ciliary sulcus fixation of posterior chamber intraocular lens implants.

We present our results of transcleral ciliary sulcus fixation of posterior chamber intraocular lens implants (IOL) in IOL exchange cases, secondary implants, and complicated cataract extractions. Follow-up data are presented on a total of 19 patients. The technique is facilitated by using a long needle attaching 10-0 prolene suture to both haptics of an all polymethylmethacrylate (PMMA) posterior chamber intraocular lens implant (PCL). Our early results show that the procedure is safe and predictable.

Cataract Extraction↗

Neodymium: YAG laser vitreolysis for treatment and prophylaxis of cystoid macular oedema.

Eighteen eyes with vitreous strands adherent to the corneoscleral wound of previous cataract surgery were treated with neodymium: YAG laser to achieve vitreolysis. Twelve eyes were treated for management of cystoid macular oedema (CMO group) and six eyes were treated for prophylaxis of possible CMO (prophylactic group). In the CMO group, visual acuity improved two or more Snellen lines in 10 eyes (83.3%) and seven eyes had a post-laser visual acuity of 20/40 or better (one eye had a pre-treatment visual acuity of 20/40 or better). In the prophylactic group, visual acuity was either maintained at the pre-treatment level or improved in five eyes (83.3%) eighteen months after laser treatment. This procedure was complicated by retinal detachment in one case and elevation of intraocular pressure over 10 mmHg in another case.

Adult↗

Preclinical evaluation of a new donor corneal trephination system.

A new corneal trephination system developed by the University of Minnesota, Department of Ophthalmology and Vision Care/3M features a corneal holder that orients and stabilizes the donor cornea during storage, transportation, and trephination. A gravity corneal punch, and disposable trephine and cutting block minimize corneal button irregularities that in other devices may contribute to postoperative astigmatism. This new system was compared with the Iowa Press by evaluating trephinated corneas on the basis of profile projectors. Buttons trephined from 10 pairs of human corneas stored in (CSM) preservation solution at 4 degrees C were evaluated by measuring diameters and edge angles and correlating them with the trephine size used. In contrast with the Iowa Press, this new system produces corneal buttons that are consistently circular, parallel-edged, and identical in size to the trephine used.

Analysis of Variance↗

Transscleral fixation of posterior chamber intraocular lenses in the absence of capsular support.

We present results obtained by transscleral ciliary sulcus fixation of posterior chamber intraocular lenses in secondary implantation, lens exchange, and in primary implantation of transsclerally fixated lenses during complicated cataract extraction. Follow-up data on 38 patients, 17 of whom have been followed for more than 12 months, are included. We conclude that the procedure is safe, effective, and predictable.

Ciliary Body↗

The importance of intraocular lens inspection prior to implantation.

Open-loop, posterior chamber intraocular lenses were obtained from existing inventories of regional hospitals and surveyed for functional (optical) and structural defects. The majority of lenses (90%) were acceptable by industry optical grade standards. Most of the lenses (90%) varied by at least 0.5 diopter from the power stated on the packaging. Two lenses did not meet optical resolution standards. Most of the lenses (80%) had some surface or loop surface abnormality as judged by scanning electron microscopy. Four of the lenses had surface protrusions or burrs, either at the tip of the loop or at the lens-optic junction. These more serious defects could be seen easily at magnifications of the operating microscope. The lenses with serious structural defects tended to be the same as those lenses with functional (optical) defects. This study demonstrates the usefulness of careful intraoperative examination using the operating microscope prior to intraocular lens implantation to detect manufacturing defects which continue to exist in currently manufactured lenses. Lens inspection should be directed to the ends of the loops, the loop-optic junction, and the internal surface of the positioning holes.

Humans↗