Search PubMed⌕ Search

Biomedical subjects

R L Freyman

Publications and source records attributed to R L Freyman.

23 records · Page 2Linked to original sources

Temporal resolution in sensorineural hearing-impaired listeners.

Temporal masking curves were obtained from 12 normal-hearing and 16 hearing-impaired listeners using 200-ms, 1000-Hz pure-tone maskers and 20-ms, 1000-Hz fixed-level probe tones. For the delay times used here (greater than 40 ms), temporal masking curves obtained from both groups can be well described by an exponential function with a single level-independent time constant for each listener. Normal-hearing listeners demonstrated time constants that ranged between 37 and 67 ms, with a mean of 50 ms. Most hearing-impaired listeners, with significant hearing loss at the probe frequency, demonstrated longer time constants (range 58-114 ms) than those obtained from normal-hearing listeners. Time constants were found to grow exponentially with hearing loss according to the function tau = 52e0.011(HL), when the slope of the growth of masking is unity. The longest individual time constant was larger than normal by a factor of 2.3 for a hearing loss of 52 dB. The steep slopes of the growth of masking functions typically observed at long delay times in hearing-impaired listeners' data appear to be a direct result of longer time constants. When iterative fitting procedures included a slope parameter, the slopes of the growth of masking from normal-hearing listeners varied around unity, while those from hearing-impaired listeners tended to be less (flatter) than normal. Predictions from the results of these fixed-probe-level experiments are consistent with the results of previous fixed-masker-level experiments, and they indicate that deficiencies in the ability to detect sequential stimuli should be considerable in hearing-impaired listeners, partially because of extended time constants, but mostly because forward masking involves a recovery process that depends upon the sensory response evoked by the masking stimulus. Large sensitivity losses reduce the sensory response to high SPL maskers so that the recovery process is slower, much like the recovery process for low-level stimuli in normal-hearing listeners.

Female↗

Frequency discrimination as a function of tonal duration and excitation-pattern slopes in normal and hearing-impaired listeners.

Frequency difference limens were determined as a function of stimulus duration in five normal-hearing and seven hearing-impaired subjects. The frequency DL duration functions obtained from normal-hearing subjects were similar to those reported by Liang and Chistovich [Sov. Phys. Acoust. 6, 75-80 (1961)]. As duration increased, the DL's improved rapidly over a range of short durations, improved more gradually over a middle range of durations, and reached an asymptote around 200 ms. The functions obtained from the hearing-impaired subjects were similar to those from normal subjects over the middle and longer duration, but did not display the rapid changes at short durations. The paper examines the ability of a variation of Zwicker's excitation-pattern model of frequency discrimination to explain these duration effects. Most, although not all, of the effects can be adequately explained by the model.

Adult↗

Psychometric functions for frequency discrimination from listeners with sensorineural hearing loss.

Psychometric functions for pulsed pure-tone frequency discrimination were obtained from hearing-impaired listeners at frequencies with normal hearing and at frequencies with mild or moderate hearing losses. The general form of psychometric functions at hearing-impaired frequencies was found to be the same as at normal-hearing frequencies, i.e.,d' was linear with the frequency difference between tones, in Hz. For all but one psychometric function, the addition of an intercept term to the fitting equation did not account for significantly more variance than did the slope term alone. Therefore, it was concluded that psychometric functions for frequency discrimination can be adequately described with only one parameter: the slope of the psychometric function. Deficits in discrimination at hearing-loss frequencies were manifested by more gradual slopes of psychometric functions. Procedures for normalizing psychometric functions are presented, which facilitate comparisons of normal and impaired frequency discrimination data across studies and frequencies. Comparisons of dlf's (difference limen for frequency) obtained with adaptive and fixed procedures show a bias toward larger dlf's with adaptive procedures, but only at higher frequencies. A discussion of equal-interval and equal-ratio adaptive stepping rules indicates that an equal-ratio rule may be preferable.

Auditory Threshold↗

Broadened forward-masked tuning curves from intense masking tones: delay-time and probe-level manipulations.

Forward-masked psychophysical tuning curves were obtained from normal-hearing listeners under two conditions: lengthened delay time between masker and probe, and increased probe level. Both conditions required higher-level masking tones and both conditions resulted in broader tuning curves. Comparisons were made of tuning curves obtained with different probe-level and delay-time combinations that were chosen to require equivalent masker levels at the probe frequency. Nearly identical tuning-curve shapes were obtained when masker level at the probe frequency was the same. The results are predicted by a two-process model, consisting of a nonlinear filter followed by an exponential decay. Tuning-curve shapes in forward masking appear to be largely dependent upon the masker level (filter output level) at which one attempts to measure them.

Auditory Perception↗

A general equation describing frequency discrimination as a function of frequency and sensation level.

Frequency-discrimination thresholds, for a wide range of stimulus frequencies and stimulus levels, were obtained from three normal-hearing listeners. Linear regression analyses of the present data, and of data from two previous studies, indicate that an SL-1 transformation of stimulus level and a square root F transformation of stimulus frequency yield linear dimensions that allow accurate predictions of frequency-discrimination thresholds from normal-hearing listeners over a wide range of stimulus frequencies (125-8000 Hz) and stimulus levels (5-8 dB SL) with a single prediction equation.

Humans↗