R L Ehman

Publications and source records attributed to R L Ehman.

At least 127 records · Page 7Linked to original sources

Diradical nitroxyl spin label contrast agents for magnetic resonance imaging. A comparison of relaxation effectiveness.

The proton relaxation enhancement characteristics of seven potential MRI contrast agents containing two nitroxyl spin labels per molecule (diradicals) were compared with eight similar agents with only one spin label per molecule (monoradicals). Diradical nitroxyls were evaluated to test the hypothesis that multiple paramagnetic centers in one molecule will result in stronger proton relaxation enhancement characteristics, allowing effective contrast enhancement at lower molar concentrations and thus a reduced osmotic load and greater safety. The acute toxicity of these agents is believed to be largely related to osmotic load. Five of seven diradical nitroxyls tested had spin-lattice relaxivities that were substantially greater than all eight of the monoradicals tested. The spin-spin relaxation properties of these agents and other pertinent characteristics are favorable for contrast enhancement. The results indicate that diradical nitroxyl spin labels may be used advantageously for the design of safer, more effective MRI contrast agents.

Chemical Phenomena↗

Influence of physiologic motion on the appearance of tissue in MR images.

Studies were performed to determine the possible influence of physiologic motion on the parenchymal intensity of organs in magnetic resonance (MR) images. It is known that periodic motion associated with respiration and cardiac function causes characteristic artifacts in spin-warp images. The present study shows that bulk motion can also cause striking intensity changes at velocities equivalent to the craniocaudal respiratory excursion of organs in the upper abdomen. The magnitude of the effect depends on the velocity and direction of motion with respect to the three orthogonal axes of the imager and on the technical details of the imager and pulse sequence. Large systematic errors in calculated tissue relaxation times are possible due to this phenomenon. The findings have important implications for clinical imaging because motion can cause artifactual changes in the gray-scale relationships among tissues. Some pulse sequences are much less sensitive to these effects. These results provide guidance for selecting MR techniques that reduce the detrimental effect of respiratory and other physiologic motion on examinations of the upper abdomen and thorax.

Abdomen↗

Bone marrow in children with acute lymphocytic leukemia: MR relaxation times.

Magnetic resonance imaging of the lumbar spine was performed in 17 children with acute lymphocytic leukemia (ALL): eight with newly diagnosed ALL, four with ALL in relapse, and five with ALL in remission. Eleven age-matched children were also imaged as controls. The T1 and T2 relaxation times of the bone marrow in the lumbar spine were calculated for all the children. The T1 relaxation times of the bone marrow were as follows (mean +/- standard deviation): newly diagnosed ALL, 968 msec +/- 68; ALL in relapse, 765 msec +/- 19; ALL in remission, 404 msec +/- 135; and age-matched controls, 441 msec +/- 82. T1 relaxation time was statistically significant in differentiating children with newly diagnosed ALL from normal children and from children with ALL in remission. In addition, T1 may be useful in differentiating children with ALL in relapse from children with ALL in remission and from healthy children. T2 was not significantly different among the four groups.

Adolescent↗

Magnetic resonance imaging of musculoskeletal trauma.

Magnetic resonance imaging has unique capabilities for evaluating musculoskeletal trauma. It can clearly delineate tears and hemorrhage in muscles, ligaments, and tendons and can provide clinically useful information in patients with joint injuries. Other developing applications include evaluation of compartment syndromes, injuries of peripheral nerves and blood vessels, and chronic sequelae of trauma. If a correct technical approach is employed, MRI has a clinical role that is complementary to other imaging modalities.

Adolescent↗

Enhanced MRI of tumors utilizing a new nitroxyl spin label contrast agent.

Nitroxyl spin labels have been shown to be effective in vivo contrast agents for magnetic resonance imaging (MRI) of the central nervous system, myocardium, and urinary tract. A new pyrrolidine nitroxyl contrast agent (PCA) with better resistance to in vivo metabolic inactivation than previously tested agents was studied for its potential to enhance subcutaneous neoplasms in an animal model. Twenty-two contrast enhancement trials were performed on a total of 15 animals 4-6 weeks after implantation with human renal adenocarcinoma. Spin echo imaging was performed using a .35 T animal imager before and after intravenous administration of PCA in doses ranging from 0.5 to 3mM/kg. The intensity of tumor tissue in the images increased an average of 35% in animals receiving a dose of 3 mM/kg. The average enhancement with smaller doses was proportionately less. Tumor intensity reached a maximum within 15 min of injection. The average intensity difference between tumor and adjacent skeletal muscle more than doubled following administration of 3 mM/kg of PCA. Well-perfused tumor tissue was more intensely enhanced than adjacent poorly perfused and necrotic tissue.

Animals↗

The "broken ring" sign in magnetic resonance imaging of partial anomalous pulmonary venous connection to the superior vena cava.

In two patients with partial anomalous pulmonary venous connection to the superior vena cava, we attempted to demonstrate the pertinent anatomic abnormalities by using magnetic resonance imaging. The results show that magnetic resonance imaging is an ideal cardiovascular imaging modality. The observation of a "broken ring" structure in the magnetic resonance image of the superior vena cava is proposed as a diagnostic sign of partial anomalous pulmonary venous connection to the superior vena cava.

Adolescent↗

Magnetic resonance imaging in the diagnosis of acute renal allograft rejection and its differentiation from acute tubular necrosis. Experimental study in the dog.

This study was designed to evaluate the potential utility of magnetic resonance imaging (MRI) for the diagnosis of acute renal allograft rejection and its differentiation from acute tubular necrosis (ATN). Eighteen canines were used. Five animals served as controls. ATN was induced in six animals by cross-clamping of the left renal artery for 90 minutes. In order to study acute renal allograft rejection, seven animals were subjected to exchange allograft transplantation of the left kidney. MRI was performed with a 0.35T superconductive magnet. A double spin-echo technique was used with varying TR and TE parameters. The spin echo images were analyzed for morphology, signal intensity, T1 and T2 relaxation times, and spin density. The most useful MRI criteria for the diagnosis of ATN and acute rejection were found to be the renal size, the intensity difference between cortex and medulla (corticomedullary contrast), and the T1 relaxation time of the cortex. Normal kidneys showed maximal corticomedullary contrast (19% +/-2) on images obtained with TR = 0.5 sec and TE = 28 msec. Cortical T1 relaxation time was 551 msec + /-73. In the ATN group, the kidneys were slightly swollen (P = ns) and the corticomedullary contrast (11% + /-3) was reduced by 42% (P less than .01). T1 of the cortex (689 + /-142) was increased by 25% (P less than .10). In acute rejection, significant renal enlargement was noted (P less than .05).(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Kidney Injury↗

MR imaging with surface coils.

The use of specialized coils to improve signal-to-noise ratios in magnetic resonance (MR) imaging is an important innovation. The role of surface coils has not yet been well defined, but it seems likely that they will be routinely used for clinical imaging of the orbit, neck, and spine. Surface coils have important limitations that make other designs, such as "closely coupled" volume coils, attractive for some applications, especially for limb imaging. With improvement in our ability to visualize anatomy with MR imaging, specialized radio frequency coils may provide new imaging capabilities for clinical problems that were not previously considered to be indications for diagnostic imaging.

Humans↗

Reproducibility of T1 and T2 relaxation times calculated from routine MR imaging sequences: phantom study.

Measurement of T1 and T2 relaxation times has been sought as one fundamental way to characterize tissue. Relaxation times can be calculated from routine spin-echo (SE) imaging sequences using two distinct repetition times (TRs), each with two SE samplings of signal intensity. Previous reports have quantified relaxation times without discussing the variation in their measurements. By imaging a phantom containing different samples with known T1 and T2 relaxation times on three separate occasions, the variation in relaxation time measurements inherent in different routine imaging sequences was studied. For the present study a more complete and accurate equation was used to calculate T1 values. The variation in T1 and T2 relaxation times for samples with relaxation times similar to solid tissue was 2%-4%. The amount of variability in calculated relaxation times was found to be dependent on the magnitude of the relaxation times themselves. However, the mean values were independent of the imaging sequences used to calculate the relaxation times. No significant differences were seen between left-to-right or section-to-section position within the same study or between studies performed on different occasions. The variability in the calculated T1 was dependent on the pair of TR sequences used to calculate T1. Samples with long T1 and T2 relaxation times, similar to many body fluids, had much larger variability. A computer simulation of measurement error was created to explain these results. This study indicates that properly performed routine imaging studies do yield reproducible T1 and T2 measurements.

Computers↗

Reproducibility of relaxation times and spin density calculated from routine MR imaging sequences: clinical study of the CNS.

This study was undertaken to determine if routine clinical magnetic resonance imaging sequences using only two different repetition times (TRs) and with only two sequential spin echoes (SEs) can be used to calculate reproducible relaxation time and spin density values for normal central nervous system tissue using a 0.35 T production-model instrument. In 43 patients 650 regions of interest of 11 different anatomic sites were measured. T1 and T2 relaxation times and spin density were measured. For each anatomic location, the mean and standard deviation of these values were determined. In most solid regions of brain, the standard deviation of both T1 and T2 was 4%-8%. Relaxation times of cortical gray matter varied more, with a standard deviation of 10%, probably because of volume-averaging with adjacent cerebrospinal fluid (CSF). CSF and ocular vitreous humor were neither reproducibly nor accurately measured because of the short TR and TE settings of the imaging sequences relative to the long T1 and T2 relaxation times of these substances. Significant and reproducible differences were found between the spin densities of gray matter and white matter, as well as between different regions of white matter. These differences are of major importance in contrast discrimination of gray and white matter on the long TR images. Knowing that relaxation values and spin densities calculated from routine imaging sequences are in fact reproducible, these normal ranges can now be used to investigate changes occurring in disease states.

Adolescent↗

Acute myocardial ischemia: magnetic resonance contrast enhancement with gadolinium-DTPA.

Gadolinium-DTPA (Gd-DTPA) was used to improve the diagnostic utility of magnetic resonance (MR) in detecting early ischemia, before the onset of infarction. Following one minute of left anterior descending coronary artery occlusion, 9 dogs were intravenously injected with either 0.5 mM/kg of Gd-DTPA (6 dogs) or normal saline (3 dogs). One more minute was allowed for perfusion of injectate prior to cardiectomy and MR imaging of the ex situ heart. There was no visible difference in intensity or alterations in magnetic relaxation times between normal and ischemic myocardium in the control (saline-injected) animals. The Gd-DTPA-injected dogs had a well-defined segment of high intensity representing the ischemic myocardium in the anterior wall of the left ventricle, due to significant T2 relaxation rate enhancement in the adjacent normal myocardium. Both T1 and T2 were significantly (p less than 0.01) shortened in the normal myocardium of the Gd-DTPA animals, but relatively greater T2 relaxation rate enhancement resulted in reduced intensity of normal myocardium, thus increasing contrast with ischemic myocardium. As a result of the significant shortening of T1 and T2 in the normal myocardium relative to the ischemic myocardium, improved delineation of the ischemic segment could be obtained using calculated T1 and T2 images. It is concluded that Gd-DTPA has the potential to expand the sensitivity and diagnostic utility of MR in the study of occlusive coronary artery disease.

Animals↗

Effect of gadolinium-DTPA on the magnetic relaxation times of normal and infarcted myocardium.

Acute myocardial infarctions were produced in 11 dogs by ligation of the left anterior descending coronary artery. Twenty-four hours after ligation, 0.35 millimoles per kilogram of Gd-DTPA was injected intravenously, followed by cardiectomy either 90 seconds (3 dogs) or 5 minutes (5 dogs) later. The remaining 3 dogs had cardiectomy without injection of Gd-DTPA at 24 hours after coronary occlusion. The 3 dogs that did not receive Gd-DTPA had longer T1 and T2 relaxation times in infarcted myocardium than in normal myocardium, as measured by a 10.7-MHz magnetic resonance (MR) spectrometer. The T1 and T2 relaxation times of normal myocardium at 90 seconds postinjection of Gd-DTPA were significantly shorter (p less than 0.05) than those of the normal myocardium of animals that did not receive Gd-DTPA. At five minutes postinjection, significantly (p less than 0.01) greater T1 shortening was exhibited in the infarcted myocardium compared with adjacent normal myocardium in the dogs injected with Gd-DTPA. Thus, Gd-DTPA has differential and time-varying effects on relaxation times of normal and infarcted myocardium.

Animals↗

Spin-spin relaxation time (T2) dependence in MR saturation- and inversion- recovery images.

The intensities of regions of interest in saturation-recovery (SR) and inversion-recovery (IR) images obtained with a new magnetic resonance (MR) scanner were compared with theoretically expected results, using phantom materials that had been accurately characterized in a specialized MR spectrometer. The data revealed significant dependence on the spin-spin relaxation time (T2), which was not expected on the basis of a simple model. The cause of this T2 dependence is discussed. The appearance and contrast of certain tissues in IR and SR images may be different than expected on the basis of the simple model. The results indicate that caution is required in making general claims about the efficacy of specific MR techniques because of potential subtle differences in the way that even the most basic sequences are implemented on individual imaging devices.

Electron Spin Resonance Spectroscopy↗

Magnetic resonance imaging with respiratory gating: techniques and advantages.

Respiratory motion is an important problem in magnetic resonance imaging (MRI) of the thorax and upper abdomen. This study assessed several approaches for practical respiratory gating. Methods of acquiring respiratory signals, gated sequencing methods, duration of examination, strategies for reducing examination time, diagnostic quality of gated images, and the influence of respiratory gating on relaxation time measurements were evaluated. Of three different devices for acquiring the respiratory signal, a belt containing a displacement transducer placed around the upper abdomen was found to be most effective and practical. Two pulse-gating modes were implemented, as well as a method for combining cardiac and respiratory gating. Gating methods were tested using phantoms and human volunteers. A spin-conditioned mode of respiratory gating was found to be superior to a more simply implemented triggered mode in which spin-echo (SE) sequencing was interrupted. The time penalty for respiratory gating is technique-dependent. Gated studies with uncontrolled tidal breathing took two to four times longer than nongated studies. When the time between respirations was voluntarily prolonged, gated studies could be only 30%-50% longer than nongated. The standard deviation of relaxation-time measurements for organs that are displaced during respirations was substantially reduced by respiratory gating. Gating acquisition without spin-conditioning gating. Respiratory gating is a practical and useful technique for improving the contrast and spatial resolution of SE images of the upper abdomen and chest. SE images produced with short repetition times were particularly improved by respiratory gating.

Humans↗

Retrorenal gallbladder. A case report.

Abdominal computed tomography revealed a mass posterior to the right kidney in a patient with a history of malignancy. This mass was demonstrated to be an abnormally situated gallbladder.

Aged↗

Tracking motion with tagged rapid gradient-echo magnetization-prepared MR imaging.

A technique for rapid assessment of tissue motion was developed by combining spatially selective radio-frequency tagging pulses with centric phase-encoding view ordering in a T1-weighted, magnetization-prepared gradient-echo acquisition sequence. This sequence allowed labeling and tracking of tissue motion with single-image acquisition times of less than 3 seconds. Multiple tagged bands 3mm thick were superimposed orthogonal to the imaging plane. Motion in the interval between tagging and the start of image acquisition could then be precisely determined. The technique was evaluated with phantom studies and then applied to human volunteers for assessment of skeletal muscle motion, phonation, and pelvic floor motion.

Humans↗

Pelvic imaging with phased-array coils: quantitative assessment of signal-to-noise ratio improvement.

The signal-to-noise ratios (S/Ns) of two different pelvic magnetic resonance (MR) imaging phased arrays were compared with that of the body coil. Each array consisted of two coils placed anteriorly and two posteriorly, oriented transversely in one array and longitudinally in the other. S/N measurements were obtained in an adjustable water-filled phantom that stimulated the shape and radio-frequency loading effects of various-size patients. Depending on the simulated anterior-posterior thickness of the patient, the S/N produced by the longitudinal array ranged from 2.3 to 3.1 times higher than that of the body coil. The S/N of the transverse array was 3.1 to 3.4 times higher. The increased coil sensitivity permits imaging with shorter acquisition times, smaller fields of view, finer resolution, and/or thinner sections. Two examples in patients demonstrate the enhanced imaging capability of the phased arrays.

Female↗