MRI-guided needle localization of suspicious breast lesions: results of a freehand technique.

Magnetic resonance imaging (MRI) can detect clinically and mammographically occult breast lesions. In this study we report the results of MRI-guided needle localization of suspicious breast lesions by using a freehand technique. Preoperative MRI-guided single-needle localization was performed in 220 patients with 304 MRI-only breast lesions at our hospital between January 1997 and July 2004. Procedures were performed in an open 0.5-T Signa-SP imager allowing real-time monitoring, with patient in prone position, by using a dedicated breast coil. MRI-compatible hookwires were placed in a noncompressed breast by using a freehand technique. MRI findings were correlated with pathology and follow-up. MRI-guided needle localization was performed for a single lesion in 150 patients, for two lesions in 56 patients, and for three lesions in 14 patients. Histopathologic analysis of these 304 lesions showed 104 (34%) malignant lesions, 51 (17%) high-risk lesions, and 149 (49%) benign lesions. The overall lesion size ranged from 2.0-65.0 mm (mean 11.2 mm). No direct complications occurred. Follow-up MRI in 54 patients showed that two (3.7%) lesions were missed by surgical biopsy. MRI-guided freehand needle localization is accurate and allows localization of lesions anterior in the breast, the axillary region, and near the chest wall.

Adult↗

Freehand iMRI-guided large-gauge core needle biopsy: a new minimally invasive technique for diagnosis of enhancing breast lesions.

The lack of reliable methods for minimally invasive biopsy of suspicious enhancing breast lesions has hindered the utilization of contrast-enhanced magnetic resonance imaging (MRI) for the detection and diagnosis of breast cancer. In this study, a freehand method was developed for large-gauge core needle biopsy (LCNB) guided by intraprocedural MRI (iMRI). Twenty-seven lesions in nineteen patients were biopsied using iMRI-guided LCNB without significant complications. Diagnostic tissue was obtained in all cases. Nineteen of the 27 lesions were subsequently surgically excised. Histopathologic analysis confirmed that iMRI-guided LCNB correctly distinguished benign lesions from malignancy in 18 of the 19 lesions. The histology revealed by core biopsy was partially discrepant with surgical biopsy in 2 of the other 19 lesions. Freehand iMRI-guided LCNB of enhancing breast lesions is promising. Larger studies are needed to determine the smallest lesion that can be sampled reliably and to precisely measure the accuracy of iMRI-guided LCNB as a minimally invasive tool to diagnose suspicious lesions found by breast MRI. J. Magn. Reson. Imaging 2001;13:896-902.

Adult↗

Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection.

PURPOSE: To retrospectively determine the mammographic characteristics of cancers missed at screening mammography and assess the ability of computer-aided detection (CAD) to mark the missed cancers. MATERIALS AND METHODS: A multicenter retrospective study accrued 1,083 consecutive cases of breast cancer detected at screening mammography. Prior mammograms were available in 427 cases. Of these, 286 had lesions visible in retrospect. The 286 cases underwent blinded review by panels of radiologists; a majority recommended recall for 112 cases. Two experienced radiologists compared prior mammograms in 110 of these cases with the subsequent screening mammograms (when cancer was detected), noting mammographic characteristics of breast density, lesion type, size, morphology, and subjective reasons for possible miss. The prior mammograms were then analyzed with a CAD program. RESULTS: There were 110 patients with 115 cancers. On the prior mammograms with missed cancers, 35 (30%) of the 115 lesions were calcifications, with 17 of 35 (49%) clustered or pleomorphic. Eighty of the 115 (70%) were mass lesions, with 32 of 80 (40%) spiculated or irregular. For calcifications and masses, the most frequently suggested reasons for possible miss were dense breasts (12 of 35; 34%) and distracting lesions (35 of 80; 44%), respectively. CAD marked 30 (86%) of 35 missed calcifications and 58 (73%) of 80 missed masses. CONCLUSION: Detection errors affected cases with calcifications and masses. CAD marked most (77%; 88 of 115) cancers missed at screening mammography that radiologists retrospectively judged to merit recall.

Adult↗

Breast electron boost planning: comparison of CT and US.

PURPOSE: To compare computed tomography (CT) with ultrasonography (US) for depiction of the biopsy cavity. MATERIALS AND METHODS: Thirty-two consecutive patients who underwent radiation therapy following lumpectomy with a planned electron boost were examined. At the time of simulation for whole-breast radiation therapy, all patients underwent planning CT (CT 1) at 3-mm section intervals. At the time of electron boost simulation, US was performed to define the biopsy cavity. In 17 cases, a second CT examination (CT 2) was performed at the time of electron boost simulation. CT and US studies were reviewed jointly and assigned a cavity visualization score (CVS) of 1 (cavity not visualized) to 5 (all cavity margins clearly defined). RESULTS: The median CVS at CT 1 was 5; at CT 2, 4; and at US, 4. For patients who underwent all three studies, the median CVS at CT 1 was 5; at CT 2, 4; and at US, 4. Factors related to CVS at CT 1 were homogeneous versus heterogeneous appearance (score, 5 vs 4), surgery-to-CT interval (< or =30 days, 5; 31-60 days, 4; >60 days, 4), and cavity size (>15 cm(3), 5; <15 cm(3), 4). In all cases, cavity volume decreased somewhat during the CT 1-to-CT 2 interval. CONCLUSION: CT performed at the time of whole-breast simulation can be used to plan electron boost fields, with cavity visualization similar to that at US.

Adult↗

Breast cancer: variables affecting sentinel lymph node visualization at preoperative lymphoscintigraphy.

PURPOSE: To compare patients with visualized sentinel lymph nodes (SLNs) and patients with nonvisualized SLNs, with a focus on variables affecting SLN visualization at preoperative lymphoscintigraphy and on nodal drainage basins as related to tumor location. MATERIALS AND METHODS: One hundred thirty-six patients who had breast cancer underwent preoperative lymphoscintigraphy before SLN biopsy. Patients with visualized and nonvisualized SLNs were compared for age; tumor site, size, and histologic findings; injection guidance method; diagnostic biopsy type; interval between biopsy and lymphoscintigraphy; intraoperative identification method; and surgical identification rate. Visualized SLN drainage basins were noted. RESULTS: Ninety-nine patients had visualized and 37 had nonvisualized SLNs, without statistically significant differences in tumor site, size, and histologic findings; injection guidance method; diagnostic biopsy type; and interval between biopsy and lymphoscintigraphy. Ninety-nine (73%) of the 136 SLNs were visualized at lymphoscintigraphy; 30 (81%) of the 37 nonvisualized SLNS were identified at surgery. Of the seven SLNs not identified at surgery, five were mapped with radiocolloid only. Patients with nonvisualized SLNs were older than those with visualized SLNs. Eleven (46%) of 24 tumors with internal mammary drainage were in the outer part of the breast. CONCLUSION: Patients with and those without visualization differed in age, SLN identification at surgery, and surgical identification method. Nonvisualized status does not preclude axillary metastasis. In older patients with nonvisualized SLNs, blue dye may aid in SLN detection, as compared with isotope-only localization.

Adult↗

The mammography quality standards act: benefits and burdens.

The Mammography Quality Standards Act (MQSA) took the voluntary peer review process of the American College of Radiology (ACR) Mammography Accreditation Program (MAP) and used it for the foundation of a stringent set of federal regulations. By mandating accreditation, certification, and inspection for all providers, the legislative objective was to assure American women that they have the equal opportunity for quality breast cancer screening no matter where they reside. However, as with any government regulation there is an inherent cost to the regulated community. This article will address the need for regulation, the positive impact and the additional burdens that have resulted.

Journal Article↗

Potential role of magnetic resonance imaging and other modalities in ductal carcinoma in situ detection.

Ductal Carcinoma In Situ (DCIS) is the earliest form of ductal cancer, with a high rate of care if treated early. This article outlines the use of breast imaging in DCIS diagnosis, including mammography, MR imaging, and nuclear medicine studies. While MR imaging and nuclear medicine show great promise in DCIS diagnosis, mammography remains the mainstay of DCIS detection by the presence of microcalcifications in early tumors on the mammogram.

Breast Neoplasms↗

Characterization of breast lesion morphology with delayed 3DSSMT: an adjunct to dynamic breast MRI.

The purpose of the study was to determine the sensitivity and specificity of various morphologic criteria in distinguishing malignant from benign breast lesions using a new sequence (3DSSMT) performed immediately after dynamic breast MRI. 3DSSMT combines a water-selective spectral-spatial excitation and an on-resonance magnetization transfer pulse with three-dimensional spoiled gradient-echo imaging. Morphologic features of 87 pathologically confirmed lesions were analyzed. The presence of either skin thickening, or a combination of a spiculated or microlobulated border, with a rim, ductal, linear, or clumped enhancement pattern was 94% specific and 54% sensitive for malignancy. Conversely, the presence of either a perfectly smooth border, a well-defined margin, non-enhancing internal septations, or a macrolobulated border was 97% specific and 35% sensitive for a benign diagnosis. In conclusion, delayed 3DSSMT discriminates a significant number of benign and malignant breast lesions; it has the potential to improve the diagnostic accuracy of dynamic breast MRI.

Breast↗

Dynamic breast MRI with spiral trajectories: 3D versus 2D.

A three-dimensional (3)D spiral sequence was developed for dynamic breast magnetic resonance (MR) imaging with much improved image quality. Partial Z phase encoding was applied to obtain thinner slices for a coverage of the whole breast. Comparison between the 3D and a previously developed multi-slice 2D spiral sequences was performed on ten healthy volunteers without contrast and five breast patients with gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA). The 3D spiral images had significantly less off-resonance blurring and spiral artifacts. With a small compromise on temporal resolution (7.7 seconds in 2D and 10.6 seconds in 3D), we obtained 32 interpolated 3-5 mm slices (with 20 Z phase encodes) for a full coverage of 10-16 cm breast with the same 1 x 1 mm2 in-plane resolution as the 2D sequence, which had 12 8-13 mm slices. Contrast between glandular and soft tissue in normal breasts was increased by about 25%. The reduced repetition time in the 3D spiral acquisition led to an increased Gd-enhanced signal. The difference between the enhancement of malignant and benign lesions increased by sevenfold. We expect that this new development could lead to improved specificity in characterizing breast lesions using MR imaging.

Adult↗

Radiofrequency ablation of breast cancer: first report of an emerging technology.

HYPOTHESIS: Radiofrequency (RF) energy applied to breast cancers will result in cancer cell death. DESIGN: Prospective nonrandomized interventional trial. SETTING: A university hospital tertiary care center. PATIENTS: Five women with locally advanced invasive breast cancer, aged 38 to 66 years, who were undergoing surgical resection of their tumor. One patient underwent preoperative chemotherapy and radiation therapy, 3 patients received preoperative chemotherapy, and 1 had no preoperative therapy. All patients completed the study. INTERVENTIONS: While patients were under general anesthesia and just before surgical resection, a 15-gauge insulated multiple-needle electrode was inserted into the tumor under sonographic guidance. Radiofrequency energy was applied at a low power by a preset protocol for a period of up to 30 minutes. Only a portion of the tumor was treated to evaluate the zone of RF ablation and the margin between ablated and nonablated tissue. Immediately after RF ablation, the tumor was surgically resected (4 mastectomies, 1 lumpectomy). Pathologic analysis included hematoxylin-eosin staining and enzyme histochemical analysis of cell viability with nicotinamide adenine dinucleotide-diaphorase (NADH-diaphorase) staining of snap-frozen tissue to assess immediate cell death. MAIN OUTCOME MEASURE: Cancer cell death as visualized on hematoxylin-eosin-stained paraffin section and NADH-diaphorase cell viability stains. RESULTS: There was evidence of cell death in all patients. Hematoxylin-eosin staining showed complete cell death in 2 patients. In 3 patients there was a heterogeneous pattern of necrotic and normal-appearing cells within the ablated tissue. The ablated zone extended around the RF electrode for a diameter of 0.8 to 1.8 cm. NADH-diaphorase cell viability stains of the ablated tissue showed complete cell death in 4 patients. The fifth patient had a single focus of viable cells (<1 mm) partially lining a cyst. There were no perioperative complications related to RF ablation. CONCLUSIONS: Intraoperative RF ablation results in invasive breast cancer cell death. Based on this initial report of the use of RF ablation in breast cancer, this technique merits further investigation as a percutaneous minimally invasive modality for the local treatment of breast cancer.

Adult↗

Silicone breast implant rupture: pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound.

The objective of this study was to evaluate the relative efficacies of magnetic resonance (MR) imaging, ultrasonography, and mammography in implant rupture detection and to illustrate pitfalls in MR image interpretation. Thirty patients referred by plastic surgeons with suspected breast implant rupture were prospectively evaluated using MR, ultrasonography, and mammography. Imaging examinations were interpreted independently and blindly for implant rupture and correlated to operative findings. Surgical correlation in 16 patients (53 percent) with 31 implants showed 13 (42 percent) were intact, 5 (16 percent) had severe gel bleed, and 13 (42 percent) were ruptured. MR sensitivity was 100 percent and specificity was 63 percent. Accuracy for rupture was 81 percent with MR, higher than with ultrasonography and mammography (77 and 59 percent, respectively). We describe a specific pitfall in MR interpretation, the "rat-tail" sign, composed of a medial linear extension of silicone along the chest wall. Seen in eight cases (four intact, three ruptures, one gel bleed), the rat-tail sign may lead to misdiagnosis of implant rupture if seen in isolation. Magnetic resonance imaging is more accurate and sensitive than ultrasonography and mammography in detecting breast implant rupture. We describe a new sign (rat-tail sign) composed of medial compression of the implant simulating silicone extrusion as a potential false-positive MR finding for rupture. This article presents clinical experience with magnetic resonance, mammography, and ultrasound in the diagnosis of implant rupture and defines and illustrates potential pitfalls of MR interpretation, including the new rat-tail sign.

Adult↗

Methods of compliance with Mammography Quality Standards Act regulations for tracking positive mammograms: survey results.

OBJECTIVE: We sent a questionnaire to fellows of the Society of Breast Imaging to determine how breast imaging facilities comply with regulations mandated by the Mammography Quality Standards Act for tracking patients whose mammograms show positive findings. SUBJECTS AND METHODS: We surveyed the Society of Breast Imaging fellows to determine practice types, follow-up methodology, additional time and personnel required, and end points of radiologists' responsibility for follow-up of mammograms with positive findings. RESULTS: Forty-six (68%) of 68 surveyed practices responded, including 21 academic, 16 private, and nine mixed practices that averaged 15,761 mammograms a year (range, 300-50,000). The 46 practices used computers (n = 30) or handwritten paper (n = 16) audits. Radiologists (n = 8), technologists (n = 6), other personnel (n = 10), or a combination (n = 22) tracked procedures and patients with abnormal mammographic results. Average time spent tracking was given as a few hours a week (n = 28), 2-4 hr a day (n = 11), and 40 hr a week (n = 5). The remaining two practices indicated that less than 1 hr per month was required (n = 1) or that they used two full-time data managers (n = 1). Accepted tracking end points included surgical biopsy (n = 30), referring physician recommended other management (n = 16), patient refused recommendation (n = 27), medical care transfer (n = 27), patient moved (n = 22), or patient lost to referring physician follow-up (n = 16). CONCLUSION: Among dedicated mammographers, the methodology in the task of tracking patients with positive findings on mammography varies. All methodologies described in responses to our survey involved considerable time and effort.

Breast Neoplasms↗

Virtual endoscopy using perspective volume-rendered three-dimensional sonographic data: technique and clinical applications.

OBJECTIVE: We present a technique for obtaining three-dimensional external and virtual endoscopy views of organs using perspective volume-rendered gray-scale and Doppler sonographic data, and we explore potential clinical applications in the carotid artery, the female pelvis, and the bladder. CONCLUSION: Using the proposed methods, radiologists will find it possible to create virtual endoscopy and external perspective views using sonographic data. The technique works well for revealing the interior of fluid-filled structures and cavities. However, expected improvements in computer performance and integration with existing sonographic equipment will be necessary for the technique to become practical in the clinical environment.

Carotid Arteries↗

Breast lesion localization: a freehand, interactive MR imaging-guided technique.

PURPOSE: To evaluate interactive magnetic resonance (MR) imaging-guided preoperative needle localization and hookwire placement in the noncompressed breast in patients in the prone position. MATERIALS AND METHODS: Nineteen MR imaging-guided breast lesion localization procedures were performed in 17 patients aged 38-70 years (mean age, 48 years) by using an open-platform breast coil in either a 1.5-T, closed-bore imager (n = 14) or a 0.5-T, open-bore imager (n = 5). Rapid imaging (fast spin-echo, water-selective fast spin-echo, or water-specific three-point Dixon gradient-echo) was alternated with freehand manipulation of an MR-compatible needle to achieve accurate needle placement. RESULTS: Up to three manipulations of the needle were required during an average of 9 minutes to reach the target lesion. MR imaging findings confirmed the final needle position within 9 mm of the target in all cases. The accuracy of 10 localizations was independently corroborated either at mammography or at ultrasonography. Nine lesions were visible on MR images only. CONCLUSION: Interactive MR imaging-guided, freehand needle localization is simple, accurate, and requires no special stereotactic equipment. Lesions throughout the breast, including those in the anterior part of the breast and those near the chest wall, which can be inaccessible with standard grid or compression-plate techniques, can be localized. A variety of needle trajectories in addition to the horizontal path are possible, including circumareolar approaches and tangential needle paths designed to avoid puncture of implants.

Adult↗

Breast disease: dynamic spiral MR imaging.

PURPOSE: To compare various subjective, empiric, and pharmacokinetic methods for interpreting findings at dynamic magnetic resonance (MR) imaging of the breast. MATERIALS AND METHODS: Dynamic spiral breast MR imaging was performed in 52 women suspected of having or with known breast disease. Gadolinium-enhanced images were obtained at 12 locations through the whole breast every 7.8 seconds for 8.5 minutes after bolus injection of contrast material. Time-signal intensity curves from regions of interest corresponding to 57 pathologically proved lesions were analyzed by means of a two-compartment pharmacokinetic model, and the diagnostic performance of various parameters was analyzed. RESULTS: Findings included invasive carcinoma in 17 patients, isolated ductal carcinoma in situ (DCIS) in six, and benign lesions in 34. Although some overlap between carcinomas and benign diagnoses was noted for all parameters, receiver operating characteristic analysis indicated that the exchange rate constant had the greatest overall ability to discriminate benign and malignant disease. The elimination rate constant and washout were the most specific parameters. The exchange rate constant, wash-in, and extrapolation point were the most sensitive parameters. DCIS was not consistently distinguished from benign disease with any method. CONCLUSION: Dynamic spiral breast MR imaging proved an excellent method with which to collect contrast enhancement data rapidly enough that accurate comparisons can be made between many analytic methods.

Breast↗

Compliance with recommended follow-up after percutaneous breast core biopsy.

OBJECTIVE: The purpose of this study was to use information from an established patient tracking system to evaluate patient outcome and assess patient compliance with recommended follow-up after percutaneous breast core biopsy. MATERIALS AND METHODS: All breast core biopsies performed from January 1994 through February 14, 1996, that used stereotaxic or sonographic guidance were reviewed. Clinical, imaging, and pathologic findings were correlated with patient outcomes established by recommended surgical and nonsurgical follow-up. RESULTS: Of 160 core biopsies in 153 women, 30 biopsies were performed on the basis of clinical complaints. One hundred thirty lesions were detected by mammography or sonography or both. Of the 70 lesions recommended for surgical excision, 52 (74%) had documented surgical outcomes. Mammographic surveillance was recommended for 90 lesions, of which 10 (11%) had resolved at the time of this study, 49 (54%) were on track toward 3-year lesion stability, 21 (23%) were being followed up elsewhere, four (4%) were lost to physicians, and six (7%) were lost to follow-up for other reasons. CONCLUSION: Known compliance with follow-up recommendations among these 153 patients who underwent breast core biopsy was higher for patients receiving surgical recommendation (74%) than for patients receiving imaging surveillance recommendation (54%). Problems tracking patients were caused both by loss of patients to follow-up and by incomplete reporting from referring physicians.

Biopsy, Needle↗

Interactive MR-guided, 14-gauge core-needle biopsy of enhancing lesions in a breast phantom mode.

RATIONALE AND OBJECTIVES: The authors attempted to determine the accuracy of magnetic resonance (MR) imaging-guided core-needle biopsy performed with a titanium biopsy needle in a breast phantom. MATERIALS AND METHODS: Eight 6-7-mm lesions were created at random positions in a lard breast phantom. Each 0.2-mL lesion contained 0.118 mg of gadopentetate dimeglumine, 0.0025 mL of methylene blue dye, and 23.8 mg of gelatin. Rapid fast spin-echo MR imaging was used to guide placement of a 14-gauge titanium core-biopsy needle. A 1.5-T MR imager was used with an open-platform phased-array breast coil. RESULTS: Visualization of blue dye in core specimens confirmed successful biopsy in 16 of 16 attempts. One (n = 13) or two (n = 3) passes through the "skin" of the phantom were necessary for biopsy. The needle trajectory was adjusted less than three times for each pass through the "skin" in 15 of 16 biopsies. Cores that contained lesion material were obtained in the first sample in 15 of 16 biopsies. On T1-weighted images, needles cast 7-mm-diameter artifacts. CONCLUSION: MR imaging can be used accurately to guide core-needle biopsy of 6-7-mm lesions in a breast phantom.

Biopsy, Needle↗