Hypoxemia during outpatient gastrointestinal endoscopy: the effects of sedation and supplemental oxygen.

STUDY OBJECTIVES: To compare the effects on oxygen saturation as measured by pulse oximetry (SpO2) and ECG changes of endoscopy alone, sedation followed by endoscopy, and sedation followed by endoscopy with supplemental oxygen (O2) during upper gastrointestinal (GI) endoscopy. STUDY DESIGN: Randomized trial. SETTING: Outpatient gastroenterology clinic at a university medical center. PATIENTS: 58 healthy patients scheduled for outpatient upper GI endoscopy, with no clinical evidence of respiratory disease. INTERVENTIONS: Patients were randomly allocated to three groups: Group 1 received no benzodiazepines before endoscopy and breathed room air throughout (n = 18), Group 2 received midazolam intravenously (i.v.) before endoscopy and breathed room air throughout (n = 20), and Group 3 received i.v. midazolam and 2 L/min O2 through nasal cannulae during endoscopy (Group 3; n = 20). MEASUREMENTS AND MAIN RESULTS: Data collection, which included heart rate, cardiac rhythm, and SpO2 were recorded at seven intervals: baseline, topical anesthesia of the oropharynx, mouth gag insertion, endoscope insertion, biopsy, endoscope removal, and five minutes postendoscopy. In Group 2, mean SpO2 decreased after midazolam was administered and remained depressed during endoscopy (p < 0.05). After midazolam was given, Group 2 patients differed significantly from patients in Groups 1 and 3 (p < 0.05). CONCLUSIONS: The use of hypnotic doses of benzodiazepines is the primary factor responsible for the reduced oxygenation seen during endoscopy. Neither the presence of the endoscope alone nor the use of midazolam with supplemental O2 caused a decreased oxygenation. This study also suggests that the routine use of benzodiazepines is unnecessary when the endoscopy is of short duration, and the endoscopist employs good topicalization of the oropharynx. In patients who require sedation for endoscopy, O2 administration prevents hypoxemia.

Electrocardiography↗

Foreign body complications of central venous catheterisation in critically ill patients.

In three critically ill patients, central venous catheter--associated foreign bodies were identified while the patients were in the intensive care unit. Two patients had fragments of retained catheter; in the third patient a guide-wire was lost within the vascular tree. The catheter fragments were associated with clinical symptoms while side effects were not observed with loss of the guide-wire. All three foreign bodies were removed without complications.

Catheterization, Central Venous↗

The fast flush test: evaluation in radial artery catheter-manometer systems.

The 'fast flush test' is commonly used to determine the dynamic response of catheter-manometer systems in vivo. We compared the fast flush test with an established bench top test in vitro. The results of the two tests were compared in fifteen underdamped radical artery catheter-manometer systems. There were significant differences between the results, (P less than 0.001 for both resonant frequency and damping factor), and the variance of estimates within measurement systems was significantly greater in the case of the fast flush test (P less than 0.05 and P less than 0.005 for resonant frequency and damping factor respectively). Nevertheless, the differences between the tests were small by comparison with the errors associated with either test; in addition there was a significant linear correlation between the results of the two tests (r = 0.91, P less than 0.001 and r = 0.85, P less than 0.001 for resonant frequency and damping factor respectively). In the in vitro situation, therefore, the fast flush test provides a crude estimate of the dynamic parameters of underdamped catheter-manometer systems.

Arteries↗

Off-air recording licences.

The scheme operated by the Educational Recording Agency Ltd. (ERA) to licence educational establishments to make off-air recordings of television and radio broadcasts became effective from 30 May 1990. Rob Kirkham who is launching the scheme on behalf of ERA describes the current position and how the licence will work in practice.

Copyright↗

A study of the routine use of the Imugard IG500 Leukocyte Removal Filter illustrating a possible cause of transfusion reactions and a method of prevention.

The results of the use of the Imugard IG500 Leukocyte Removal Filter in the transfusion of 100 patients requiring leucocyte poor blood are presented. The patients were suffering from a variety of disorders. Many of them had previously received leucocyte poor blood prepared by other methods. Five patients developed non-haemolytic transfusion reactions. Subsequent investigations suggested that these were reactions to the plasma proteins present in the leucocyte poor blood prepared by filtration. A simple method of removal of these plasma proteins combined with filtration is described. The resultant product has been transfused, without incident, into the patients who previously reacted.

Anemia, Sideroblastic↗