Search PubMed⌕ Search

Biomedical subjects

R K Zeman

Publications and source records attributed to R K Zeman.

At least 55 records · Page 3Linked to original sources

Helical (spiral) CT of the abdomen.

Since its clinical introduction in the mid 1970s, techniques for CT have undergone many changes that have dramatically altered how CT scans are obtained. Helical (spiral) CT allows for faster acquisition of truly volumetric CT data than is possible with conventional scanners. Routine helical CT of the abdomen is now possible because of three major technical refinements: the development of the slip-ring gantry, improved detector efficiency, and greater tube cooling capability. This article reviews the technical principles that govern helical CT, the potential advantages and disadvantages of this technique, and initial clinical experience with helical CT of the abdomen.

Humans↗

Delayed contrast enhancement of ascitic fluid on CT: frequency and significance.

OBJECTIVE: Enhancing peritoneal fluid has been described as an uncommon finding resulting from active extravasation of contrast material from the bowel, urinary tract, or blood vessels. We have noted that enhancing peritoneal fluid occurs in other clinical settings. The CT number of ascites frequently increases between initial images obtained during bolus injection of IV contrast material and delayed images obtained after completion of the routine study. The objective of this study was to define the frequency and clinical significance of this phenomenon. SUBJECTS AND METHODS: Fifty patients (32 with malignant disease and 18 with benign disease) with free intraperitoneal fluid were examined with abdominal CT with IV contrast material. Active intraperitoneal bleeding or perforation of the bowel or bladder was not clinically suspected in any patient studied. When intraperitoneal fluid was detected on review of initial dynamic scans, a limited number of delayed scans were obtained also. Significant enhancement was determined by comparing the CT numbers of fluid on dynamic and delayed images. RESULTS: Significant delayed enhancement of intraperitoneal fluid was seen in 54% of patients, with increases averaging 25 H (range, 7-54 H). Parametric analysis indicated enhancement was inversely proportional to the amount of intraperitoneal fluid but independent of the type of IV contrast material (ionic vs nonionic), time delay (range, 10-104 min), clinical history, and serum creatinine and serum albumin levels. Enhancement occurred in both malignant and benign diseases and was more likely when small amounts of ascites were present. CONCLUSION: Enhancement of intraperitoneal fluid is a common and often striking finding on delayed CT scans after administration of IV contrast material. The phenomenon is nonspecific, occurring in a wide spectrum of clinical conditions. Caution should be used in interpreting the significance of high-attenuation intraperitoneal fluid on delayed images to avoid an erroneous diagnosis of active intraperitoneal bleeding or contrast extravasation.

Adult↗

Hepatic cavitation. A marker of transient hepatocellular injury during biliary lithotripsy.

Sonographically visible microbubbles attributable to cavitation effects have been observed in bile (within the gallbladder), in hepatic vessels, and within the liver of patients undergoing biliary lithotripsy. Cavitation effects are believed to contribute to stone fragmentation and possibly tissue injury during lithotripsy. To study the latter, the relationship between intraparenchymal hepatic cavitation and serum transaminase activity and clinical follow-up was analyzed in 81 patients undergoing 164 lithotripsy treatments. Seventy-one treatments (43%) resulted in sonographically evident microbubbles in the liver parenchyma during lithotripsy. A temporary, yet statistically significant (P < 0.01) rise in SGOT and SGPT was observed within 2 hr of completion of lithotripsy compared to those patients without hepatic microbubbles. All but one patient had a return to pretreatment baseline levels of SGOT and SGPT by two weeks after lithotripsy. In this patient, persistent elevation of transaminases was attributed to the delayed passage of fragments and not to any sequelae from hepatic cavitation effects. Ultrasound immediately after, two weeks after, and 3-12 months after lithotripsy showed no hepatic structural abnormalities. Ursodiol administration at the time of treatment did not predispose to hepatic cavitation or elevation of transaminase. Detection of hepatic microbubbles during lithotripsy is a marker of hepatocellular injury. Their correlation with transaminase elevation refutes the contention that transaminasemia results solely from fragment passage after lithotripsy. Although not associated with recognizable structural damage or long-term sequelae, cavitation effects and transaminasemia reiterate that shockwaves are not entirely benign as they traverse parenchymal organs.

Alanine Transaminase↗

PACS clinical experience at Georgetown University.

Georgetown University Hospital has been operating an image management and communications system (IMACS or PACS) for 3.5 years. This work was initially funded under the Army Medical Research and Development Command Digital Imaging Network Systems (DINS) project. The system was taken from a research system supporting only radiology tasks to one extended to clinical use, and has been used in clinical work for 3 years. This paper will summarize our PACS clinical experience and will describe the operational features implemented and those still necessary.

Computer Systems↗

Lateral arcuate ligaments of the diaphragm: anatomic variations at abdominal CT.

The authors have occasionally observed nodular areas abutting the lateral diaphragmatic surface and extending into the posterior pararenal space on computed tomographic (CT) scans. Review of the anatomy literature revealed that this finding represents inferolateral extension of the lateral arcuate ligaments, which reflect over the quadratus lumborum muscles to fuse with the diaphragm. CT scans from 100 consecutive patients were reviewed to determine the frequency, relationship to habitus, and appearance of this finding. Nodularity was found in five patients (bilateral in three, unilateral in two). The average size was 9.4 mm in the transverse plane, 6.3 mm in the anteroposterior plane, and 4.3 cm in the cephalocaudal plane. The extent of retroperitoneal fat was normal in all five patients. In one patient, there were easily visible lobulations; three patients had prominent lobulations, and one patient had few lobulations. It is important to recognize this anatomic variant to avoid confusion with disease.

Adult↗

Intraoperative bile duct sonography during laparoscopic cholecystectomy: experience with a 12.5-MHz catheter-based US probe.

During elective laparoscopic cholecystectomy, 20 patients underwent intraoperative evaluation of the biliary tract with a commercial 6.2-F, 12.5-MHz catheter-based ultrasound (US) probe. The study tested the feasibility of this technology for mapping the anatomy of the hepatoduodenal ligament and Calot triangle, assessing bile duct integrity, and detecting choledocholithiasis. The duct was studied with a transmural approach, the catheter being placed parallel to, but remaining outside, the bile duct. The common hepatic duct and common bile duct in the vicinity of the cystic duct were seen in all 20 patients; the junction of the cystic duct with the common hepatic duct was seen in nine patients (45%). After the cystic duct was clamped, no sonographic evidence to suggest bile duct injury was noted in any patient. The transmural imaging approach was tested in four pigs in whose common bile duct a single human calculus had been placed. In all instances the size and location of the calculus were accurately detected. Intraoperative US with a catheter-based system is a safe and effective means for interrogation of the extrahepatic biliary tree during laparoscopic cholecystectomy.

Adult↗

Parameters for predicting electromagnetic lithotripter failure: quality assurance implications.

Despite the extensive use of lithotripsy for treating renal and biliary calculi, there has been little data reported regarding the causes and manifestations of lithotripter failure. The clinical and service records for 145 consecutive treatments performed with the Siemens Lithostar Plus were reviewed. Service record analysis revealed eight failures of shock wave generation during a 10-month period. Six of these failures were subtle and still allowed shock wave generation. There were five in-line ultrasound probe failures during this period. The most useful clinical parameter for predicting lithotripter failure was reduced severity of sonographically evident cavitation bubbles during treatment. Lack of stone fragmentation and unexpectedly low analgesia requirements at high-power levels were less useful in predicting lithotripter failure. All clinical parameters suffered from nonspecificity. Preliminary experience, with an ongoing quality assurance program using a test object hydrophone, suggests this is a useful method of predicting lithotripter function and avoiding compromised treatments.

Equipment Failure↗

Evaluation of STIR imaging as a complement to spin-echo MR and CT of the porta hepatis/hepatoduodenal ligament.

Short TI inversion-recovery (STIR) imaging provides specific advantages over standard spin-echo (SE) MR sequences by producing additive effects of T1 and T2 brightening of pathology and suppression of the signal from surrounding fat. We retrospectively evaluated 12 patients with abnormalities, primarily neoplastic, of the porta hepatis/hepatoduodenal ligament (PH/HdL) with CT and MR imaging, including SE and STIR imaging. Masses on CT were of slightly decreased density compared to liver and seen in contrast to surrounding fat in the PH/HdL region. On MR, T1-weighted images provided comparable anatomic detail to CT, with masses clearly distinguished from surrounding fat due to the low signal intensity of masses as compared to fat. T2-weighted images clearly depicted intrahepatic lesions because of their high signal intensity relative to liver. Increased signal in extrahepatic lesions made them less distinctly seen from surrounding fat. STIR images best demonstrated tumor relative to fat. In six cases, CT was equivalent in demonstrating pathology to the best MR sequence. At least one MR sequence demonstrated pathology better than CT in 6 of 12 cases. In five of these six cases, the STIR sequence was better than CT. Thus, MR, particularly STIR imaging, provides a useful technique in imaging of PH/HdL pathology.

Adult↗

Detection of tissue injury after extracorporeal shockwave lithotripsy of gallstones.

We evaluated seven patients undergoing gallstone lithotripsy for evidence of hepatic or renal trauma after each of 10 lithotripsy treatments. Postlithotripsy magnetic resonance imaging (MRI) and sonography showed no evidence of hepatic or renal injury as compared with baseline studies. Four treatments resulted in sonographic evidence of gaseous hepatic microbubbles (analogous to "the bends") due to cavitation effects of the shockwaves. Three of these four treatments produced serum glutamicoxaloacetic transaminase and -pyruvic transaminase elevation. One patient had microscopic hematuria. Minimal tissue damage results from gallstone lithotripsy. MRI and ultrasound, performed after lithotripsy, appear to be less sensitive than transaminasemia in detecting this low-grade injury.

Adult↗

Gallstone lithotripsy: relevant physical principles and technical issues.

A basic understanding of shock wave generation is essential for the radiologist who performs gallstone lithotripsy. Shock waves differ from ordinary acoustic waves in that they have a rapid rise time, a positive pressure component that gives rise to compressive forces approaching 1,000 atm, and a low-amplitude sustained negative pressure (rarefactive) component. Shock waves are created by means of three different types of shock wave generators: spark-gap, electromagnetic, and piezoelectric. The authors describe and compare these three types of shock wave generators with regard to equipment selection. Regardless of how shock waves are generated, they share common interactions with tissue. These interactions are reviewed along with the proposed mechanisms of stone fragmentation.

Cholelithiasis↗

Gallbladder varices: imaging findings in patients with portal hypertension.

A retrospective review of the medical and imaging records of 50 patients with portal hypertension examined in the authors' department during a 2-year period identified six patients with gallbladder wall varices. Imaging studies performed in these patients included computed tomography (CT) (four patients), duplex and color Doppler flow (five patients), and magnetic resonance (MR) (four patients). Five of six patients with gallbladder varices had portal vein thrombosis. Anechoic areas within the gallbladder wall detected with ultrasonography could be distinguished from intramural edema by using duplex or color Doppler flow imaging in all five patients in whom it was used. Contrast material enhancement of these varices was detected with CT in three patients, two of whom also had adjacent mesenteric collaterals. Gradient-echo MR imaging (fast imaging in steady precession/fast low-angle shot) showed flow-related enhancement within the gallbladder wall in two patients. The presence of gallbladder wall varices may imply the presence of portal vein thrombosis. Since these varices can be a source of major blood loss, surgeons must be made aware of them when operating on patients with portal hypertension.

Adult↗

Gallstone fragmentation during biliary lithotripsy: effect of stone composition and structure.

In vitro lithotripsy with the Siemens Lithostar was conducted on 36 radiolucent or minimally calcified gallstones housed in an anthropomorphic phantom. The ease and pattern of fragmentation were correlated with global composition for the entire stone, regional or microcomposition (determined by Fourier-transform infrared spectroscopy), and microstructure (determined by scanning electron microscopy). Stones made up of more than 62% cholesterol required 50% more shock waves to pulverize all fragments to 0.3 cm or less than did stones of less than 62% cholesterol (p less than .01). An inverse relationship was found between the number of shock waves needed for fragmentation and the cholesterol content (r = .77). Although a broad range of fragmentation responses occurred, little variation was seen in the ease of fragmentation within stone families. The majority of stones fractured along radially oriented cholesterol plates, but one third of stones treated showed initial chipping or flaking at the periphery before radial fracture. This type of peripheral erosion most often occurred in stones with peripheral pigment rims. These stones required more shock waves and lagged in pulverization compared with more homogeneous cholesterol stones. The efficiency of fragmentation during biliary lithotripsy correlates with the stones' global cholesterol content. A stone's architecture, as reflected by its regional composition and microstructure, partially predicts the mechanism of fragmentation. These in vitro data may be useful in further refining criteria for selecting patients and understanding the fragmentation process.

Bile Pigments↗

Imaging the gallbladder: a historical perspective.

After Wilhelm Conrad Roentgen's discovery of the X-ray in 1895, it was initially thought that gallstones could not be visualized. Surgeons relied solely on the clinical examination to detect biliary disease. Today, no evaluation of the gallbladder would be complete without the performance of an imaging study. Radiology has gone through several eras in the imaging of gallstones. The plain film era, 1895-1924, was characterized by techniques that improved soft-tissue detail, allowing better detection of radiopaque stones. The contrast media era, 1924-1960, was initiated by the invention of IV cholecystography. In 1925, oral cholecystography was developed. During the era of expanding technology, 1960-1979, percutaneous transhepatic cholangiography, scintigraphy, and sonography came into use. The therapeutic era began in the 1980s.

Cholecystography↗

MR imaging of the portal venous system: value of gradient-echo imaging as an adjunct to spin-echo imaging.

We evaluated the use of gradient-echo (GRE) as an adjunct to spin-echo (SE) MR imaging of the portal venous system. GRE imaging was performed in 31 subjects, 15 normal volunteers and 16 patients with documented portal venous disease (15 cases) or suspected disease (one case). Eight of 16 patients had venous thrombosis, five had focal thrombus, and three had complete occlusion. Six patients had extrinsic venous compression by tumor. Of the two other patients, one had an arteriovenous fistula and the other a falsely positive angiogram, suggesting portal vein occlusion. In normal subjects, GRE scans had excellent visualization of the portal venous system with high intravascular signal compared with surrounding tissues. Nine (60%) of 15 normal subjects and three patients had an artifact consisting of a curvilinear area of decreased signal that could mimic clot. In three of five patients with focal thrombus, clot was identified on GRE but not on SE images. In all three patients with occlusion, SE and GRE images demonstrated similar findings. In five of the six patients with extrinsic venous compression by tumor, SE and GRE studies showed similar findings. Of the two patients, an arteriovenous fistula was seen on GRE MR in one, and in the other, patency of the left portal vein was seen on SE and GRE images after angiography had suggested portal vein occlusion. Collateral vessels were seen in nine of 16 patients. In five of nine cases, GRE MR demonstrated more extensive collaterals than did SE MR. In summary, GRE MR provides a useful adjunct to standard SE MR imaging. Benefits include high contrast between vascular structures and surrounding tissues, reduced motion artifact, and rapid scanning within a breath-hold.

Adolescent↗