[Experimental histological contribution to the development and treatment of pseudarthrosis].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R K Schenk.
Explore the source record for details and available documents.
An electron microscopic study of the tibial epiphyseal plates of growing rats reveals that the resorption of unmineralized and mineralized cartilage occurs by two different mechanisms. During resorption the unmineralized transverse cartilaginous walls between chondrocytes are invaded by capillary sprouts. At the resorption zone, numerous cytoplasmic processes derived primarily from the perivascular cells and, to a lesser extent, from the endothelial cells of the sprouts penetrate and appear to lyse the unmineralized transverse cartilaginous walls. Hydrolases released from the degenerating chondrocytes and/or capillary sprouts may also participate in this process. The second resorption mechanism involves the mineralized longitudinal cartilaginous septa. Resorption of these septa is mediated by chondroclasts whose fine structure is identical with that of osteoclasts. The active surface of the chondroclasts has a ruffled border. The surface membrane of the chondroclasts is relatively smooth on either side of the ruffled border and lies in direct apposition with the underlying mineralized cartilage. This observation suggests that the microenvironment in the zone of resorption may be maintained by the neighboring unruffled surfaces of the chondroclasts, which thus seal off and segregate the active portions of these cells.
The present study investigated the osseointegration of dental implants with a titanium plasma-sprayed surface (TPS) in regenerated and native bone in an experimental dog study. Initially, lateral bone defects were created in the alveolar ridge on both sides of the mandible. Two months later, lateral ridge augmentation was performed with (1) autogenous corticocancellous block grafts, (2) autogenous corticocancellous block grafts and e-PTFE membrane, (3) tricalcium phosphate particles and e-PTFE membrane, or (4) canine-derived demineralized freeze-dried bone allograft particles and e-PTFE membrane. After 4 months, membranes were removed, and non-submerged titanium implants were placed in regenerated bone (test implants) and in native bone (control implants). Two months later, the animals were sacrificed and non-decalcified orofacial sections were evaluated histometrically. All implants demonstrated high percentages (59% to 75%) of bone-to-implant contact, with no significant differences across the various treatment groups. The different grafting techniques did not significantly influence the location of first bone-to-implant contact and the horizontal bone width at the most coronal bone level.
Generally, endosseous implants can be placed according to a nonsubmerged or a submerged technique and in 1-piece or 2-piece configurations. Recently, it has been shown that peri-implant crestal bone reactions differ significantly radiographically as well as histometrically under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of a microgap (interface) between the implant and the abutment/restoration in 2-piece configurations. The purpose of this study was to evaluate whether standardized radiography as a noninvasive clinical diagnostic method correlates with peri-implant crestal bone levels as determined by histometric analysis. Fifty-nine implants were placed in edentulous mandibular areas of 5 foxhounds in a side-by-side comparison in both submerged and nonsubmerged techniques. Three months after implant placement, abutment connection was performed in the submerged implant sites. At 6 months, all animals were sacrificed, and evaluations of the first bone-to-implant contact (fBIC), determined on standardized periapical radiographs, were compared to similar analyses made from nondecalcified histology. It was shown that both techniques provide the same information (Pearson correlation coefficient = 0.993; P < .001). The precision of the radiographs was within 0.1 mm of the histometry in 73.4% of the evaluations, while the level of agreement fell to between 0.1 and 0.2 mm in 15.9% of the cases. These data demonstrate in an experimental study that standardized periapical radiography can evaluate crestal bone levels around implants clinically accurately (within 0.2 mm) in a high percentage (89%) of cases. These findings are significant because crestal bone levels can be determined using a noninvasive technique, and block sectioning or sacrifice of the animal subject is not required. In addition, longitudinal evaluations can be made accurately such that bone changes over various time periods can be assessed. Such analyses may prove beneficial when trying to distinguish physiologic changes from pathologic changes or when trying to determine causes and effects of bone changes around dental implants.
Explore the source record for details and available documents.
To test the osteopromotive activity in large non-spacemaking alveolar bone sites, a total of 20 titanium dental implants were placed superior to a previously modified mandibular alveolar process in five adult beagle dogs. The supracrestal implant position resulted in a mean buccal dehiscence of 5.1 +/- 1.03 mm and a mean supracrestal bone deficit of 2.69 +/- 0.45 mm. Three treatment groups were randomly assigned: group I, ten implants treated with a titanium-reinforced expanded polytetrafluoroethylene (ePTFE) membrane (TR); group II, six implants treated with a standard ePTFE membrane (ST); and group III, four implants that received no membrane (control). Before mucoperiosteal flap closure, the bone surface was perforated and peripheral blood was injected around the implants and underneath the membranes. Clinical evaluation of submerged implant sites showed evidence of complete regeneration of the peri-implant bone defects in groups I and II, minimal bone formation in control group III, and a widening of the ridge in group I. Corresponding histologic examination of undecalcified sections demonstrated large amounts of newly formed bone beneath both types of membranes with a superficial layer of loose connective tissue. Mean gain of supracrestal regenerated bone amounted to 1.82 +/- 1.04 mm (TR group), 1.90 +/- 0.30 mm (ST group), and 0.53 +/- 1.34 mm (control group). Mean bone regeneration at the buccal dehiscences was 3.33 +/- 1.44 mm (TR group), 2.46 +/- 0.51 mm (ST group), and 2.76 +/- 0.84 mm (control group). The TR membranes showed evidence of increased alveolar bone width compared to ST membranes and control sites. These results suggest that supracrestal bone regeneration can successfully be enhanced by a submerged membrane technique in the dog model and that the titanium-reinforced membranes were able to maintain a large, protected space for blood clot stabilization without the addition of bone grafts and produced a larger bone quantity when compared to standard membranes.
In this study, standard and prototype reinforced e-PTFE membranes were used to evaluate the pattern of bone regeneration in membrane-protected defects in the mandibles of four dogs. Following a healing period of 2 and 4 months, control sites without membranes exhibited incomplete osseous healing with a persisting defect. Test sites with membranes demonstrated significantly better bone healing, although bone regeneration was not yet completed at 4 months. The histologic evaluation showed that bone regeneration, once activated, progresses in a programmed sequence through a series of maturation steps, which closely resemble the pattern of bone development and growth.
In the present histologic study of the mandibles of five foxhounds, 15 nonsubmerged titanium implants were placed in bone regenerated in extended membrane-protected defects during a 6-month healing period. The clinical and radiographic evaluation demonstrated that all 15 implants achieved functional ankylosis within 3 months following implant placement. Subsequently, eight implants were restored with fixed partial dentures and were functionally loaded for 6 months, and seven implants were left unrestored. At the completion of the study, the histologic analysis demonstrated osseointegration with direct bone-to-implant contact for all 15 implants. Therefore, it can be concluded that bone regenerated in membrane-protected defects responds to implant placement like nonregenerated bone, and that this bone is capable of bearing and sustaining functional load. The histologic comparison of restored and unrestored sites demonstrated no apparent differences concerning bone remodeling activities. Furthermore, control sites without implant placement demonstrated bone atrophy underneath the membranes with a thin cortical layer and sparse bone trabeculae. Thus, it can also be concluded that the placement of an implant into regenerated bone stimulated bone maturation and bone remodeling, whereas implant loading did not influence bone remodeling in the present study model.