Wide-field optically sectioning fluorescence microscopy with laser illumination.

We describe an extremely simple method by which optically sectioned fluorescence images may be obtained with conventional microscopes using laser illumination. A one-dimensional grid pattern is introduced into the illumination system, together with a rotating ground glass diffuser. This causes an image of the grid pattern to be projected into the specimen. Images taken at three spatial positions of the grid are processed in a simple manner to provide optically sectioned images of fluorescent specimens.

Animals↗

A wavefront generator for complex pupil function synthesis and point spread function engineering.

We describe a simple method to produce an arbitrary complex optical field using a ferroelectric liquid crystal spatial light modulator. The system is configured so as to act as a pupil plane filter in a confocal microscope. The ability to tune the complex pupil function permits the system to be used both to modify the imaging performance by effectively engineering the point spread function as well as to remove optical aberrations present in the optical system.

Journal Article↗

Adaptive aberration correction in a two-photon microscope

We demonstrate aberration correction in two-photon microscopy. Specimen-induced aberrations were measured with a modal wavefront sensor, implemented using a ferro-electric liquid crystal spatial light modulator (FLCSLM). Wavefront correction was performed using the same FLCSLM. Axial scanned (xz) images of fluorescently labelled polystyrene beads using an oil immersion lens show restored sectioning ability at a depth of 28 &mgr;m in an aqueous specimen.

Journal Article↗

A method for characterizing longitudinal chromatic aberration of microscope objectives using a confocal optical system

We describe a novel method of characterizing the longitudinal chromatic aberration of microscope objectives by recording a series of axial responses as a function of wavelength as a plane reflector is scanned through the focal region of a confocal microscope. Measurements are presented for a variety of objectives with differing degrees of correction. The use of the chromatic focal shift to measure surface profiles is also discussed.

Journal Article↗

Real-time three-dimensional imaging of macroscopic structures.

We describe an extremely simple method of obtaining optically sectioned images with conventional low-power imaging systems in real time. A single spatial frequency grid pattern is projected onto an object. Images taken at three spatial positions of the grid projection are processed to provide 3D images of macroscopic structures.

Journal Article↗

Efficient real-time confocal microscopy with white light sources.

The main advantage of confocal microscopes over their conventional counterparts arises from their ability to optically 'section' nearly transparent materials; the thin image slices thus obtained can be used to reconstruct three-dimensional images, a capability which is particularly useful for the study of biological specimens. Confocal microscopes have previously used either a single laser-illuminated point-source and single point-detector (which are scanned in tandem across the object) or white-light illumination with multiple point-sources and detectors. Single-point-source systems, however, do not usually form images in real time and are restricted to using available laser wavelengths. Multiple-point-source systems, on the other hand, produce images in real time but use light very inefficiently--typically 1% or less is used for imaging. Here we demonstrate a white-light, multiple-point-source method which can in principle produce images in real time with light efficiencies as high as 50%. This system is likely to find broad practical application, particularly in the imaging of weakly reflecting or weakly fluorescent specimens.