Search PubMed⌕ Search

Biomedical subjects

R Jaszczak

Publications and source records attributed to R Jaszczak.

13 recordsLinked to original sources

The role of lung perfusion imaging in predicting the direction of radiation-induced changes in pulmonary function tests.

BACKGROUND: The aim of this study was to determine whether preradiation (pre-RT) single photon emission computed tomography (SPECT) lung perfusion scans can be used to predict RT-induced changes in pulmonary function tests (PFTs). METHODS: Ninety-four patients irradiated for thoracic tumors had pre-RT SPECT lung perfusion scans. The presence of SPECT hypoperfusion distal to a central mediastinal tumor was qualitatively assessed visually without knowledge of PFT changes. Patients were grouped based on whether the diffusion capacity (DLCO) ever increased post-RT. Comparisons of patient groups were performed using 1-tailed Fisher exact tests. Patient follow-up was 6-56 months (mean, 30 months). To assess SPECT hypoperfusion objectively, the average dose to the computed tomography (CT)-defined lung was compared with the weighted-average dose (based on relative perfusion) to the SPECT-defined lung. The ratio between the CT- and SPECT-defined mean lung dose provided a quantitative assessment of hypoperfusion. The mean ratio for patients with central tumor and adjacent hypoperfusion was compared with that of the others (Wilcoxon rank-sum one-sided test). RESULTS: In patients with central tumors, 41% (9 of 22) with adjacent hypoperfusion had improvements in DLCO following radiation, versus 18% (3 of 17) of those without hypoperfusion (P = 0.11). In patients with lung carcinoma, the corresponding ratios were 40% (8 of 20) and 10% (1 of 10), respectively (P = 0.10). The mean ratio of CT dose to SPECT dose was 1.35 for patients with central tumors and adjacent hypoperfusion versus 1.16 for others (P = 0.017). CONCLUSIONS: The presence of SPECT hypoperfusion adjacent to a central mediastinal mass may identify patients likely to have improved PFTs following RT. Thus, SPECT imaging may be useful in models for predicting radiation-induced changes in PFTs.

Adult↗

Radiation-induced pulmonary injury: symptomatic versus subclinical endpoints.

PURPOSE: To assess the relationship between radiation (RT)-induced pulmonary symptoms and subclinical changes in pulmonary functions tests (PFT) and radiographs. MATERIALS AND METHODS: A total of 184 patients irradiated between 1992 and 1998 were prospectively evaluated for RT-induced pulmonary symptoms, changes in computed tomography (CT) density, reductions in single photon emission CT (SPECT) perfusion, and changes in pulmonary functions tests (forced expiratory volume in 1 s [FEV1] and diffusion capacity to carbon monoxide [DLCO]). Comparisons between the evaluable patients with (N=34) and without (N=106) RT-induced pulmonary symptoms were made. RESULTS: Within 6 months of RT, 80% of the RT-induced symptoms were noted. There was no association between the presence or absence of RT-induced pulmonary symptoms and the frequency of RT-induced radiographic changes (p=0.53), or in the dose-response curve for RT-induced reductions in regional perfusion. Overall, RT-induced changes in SPECT images were more commonly seen than increased density changes on CT (p<0.001). Most patients with pulmonary symptoms had relatively low pre-RT PFTs and experienced further declines following RT. CONCLUSIONS: Regional radiographic changes in CT-defined tissue density or SPECT-defined tissue perfusion are similar in patients with and without RT-induced pulmonary symptoms because these endpoints do not consider the volume of lung affected. RT-induced pulmonary symptoms are better related to post-RT PFT because they are an assessment of whole lung function. Additional studies are necessary to better define models that can predict the degree of radiation-induced changes in whole lung function.

Adult↗

Regional dose response to pulmonary irradiation using a manual method.

PURPOSE: To better understand the dose dependence of radiation therapy (RT)-induced changes in regional lung perfusion and tissue density, using a manual method to reduce inaccuracies that might be present in previously described automated methods. MATERIALS AND METHODS: Patients who were to receive RT for tumors in and around the thorax, wherein portions of healthy lung would be incidentally irradiated, were prospectively studied. Changes in regional perfusion and tissue density were assessed by comparison of pre- and post-RT single photon emission computed tomography (SPECT), lung perfusion scans and computed tomography (CT) scans, respectively. The three-dimensional dose distribution was calculated on the pre-RT CT scan and correlated to the other scans via image registration. Study volumes were defined by hand and individually visualized on pre- and post-RT scans. The manually generated dose response data were compared to data generated using automated methods. The relationship between CT density and SPECT perfusion was also determined. RESULTS: Thirteen patients with lung cancer were evaluated for changes in tissue density and 11 patients were evaluated for changes in regional perfusion at 12 months post-RT. In general, density increases with increasing regional dose, with marked changes at >60 Gy. Regional perfusion decreases with increasing regional dose. In the low dose regions, relative perfusion increases by 35% on average. Manually measured dose responses correlated well with those determined automatically. The relationship between regional perfusion and CT density indicates a wide range of perfusion over a narrow range of CT density, with markedly reduced perfusion at CT densities of > -600 and < -900 H. CONCLUSIONS: The manually generated CT density dose response data broadly agree with data previously generated using automated methods. The manually generated perfusion dose response data are in fairly good agreement with automated data, lending credibility to the accuracy of the automated methods. Regional perfusion is markedly diminished where CT density is outside the range of normal lung tissue.

Dose-Response Relationship, Radiation↗

Physical and biological predictors of changes in whole-lung function following thoracic irradiation.

PURPOSE: To develop methods of predicting the pulmonary consequences of thoracic irradiation (RT) by prospectively studying changes in pulmonary function following RT. METHODS AND MATERIALS: 100 patients receiving incidental partial-lung irradiation during treatment of tumors in or adjacent to the thorax had whole-lung function assessed via symptoms and pulmonary function tests (PFTs: FEV1-forced expiratory volume 1 s; DLCO-diffusion capacity) before and repeatedly 6-48 months following RT. All had computed tomography-based three-dimensional (3D) dose calculations with lung density heterogeneity corrections for dose-volume histogram (DVH) and normal tissue complication probability (NTCP) calculations. Functional DVHs (DVfH) based on SPECT (single photon emission computed tomography) lung perfusion scans, and serial transforming growth factor-beta (TGF-beta1) levels were available in 50 and 48 patients, respectively. The incidence and severity of changes in whole-lung function were correlated with clinical, physical, and biological factors. Exploratory statistical analyses were performed using chi-square, Pearson correlations, logistic regression, and multiple linear regression. RESULTS: RT-induced symptoms developed in 21 patients. In the overall group, the single best predictor for the development of symptoms was the NTCP (p < 0.05). Pre-RT PFTs alone were less predictive (p = 0.1 for FEV1, p = 0.08 for DLCO). A multivariate model based on pre-RT DLCO and CT-based NTCP was strongly predictive for the development of symptoms (p < 0.001). NTCPs based on SPECT-derived DVf Hs and TGF-beta1 levels did not appear to provide additional predictive value. The presence or absence of pulmonary symptoms was correlated with the decline in PFT 6 months following RT (p < 0.05). In the overall group, the degree of decline in PFTs was not well correlated with any of the dose-volume variables considered. In patients with "good" pre-RT PFTs, there was a relationship between the percent reduction in PFT and dose-volume parameters such as the percent of lung volume receiving > 30 Gy (p < 0.05). CONCLUSION: The extent of alteration in whole-lung function (symptoms or PFT changes) appears to be related to both dose-volume and pre-RT PFT parameters. The data suggest that no one variable is likely to be an adequate predictor and that multivariate predictive models will be needed. Additional studies are underway to develop better predictive models that consider physical factors such as the DVH and regional perfusion, as well as biological/clinical factors such as pre-RT PFTs and TGF-beta1.

Adult↗

The role of three dimensional functional lung imaging in radiation treatment planning: the functional dose-volume histogram.

PURPOSE: During thoracic irradiation (XRT), treatment fields are usually designed to minimize the volume of nontumor-containing lung included. Generally, functional heterogeneities within the lung are not considered. The three dimensional (3D) functional information provided by single photon emission computed tomography (SPECT) lung perfusion scans might be useful in designing beams that minimize incidental irradiation of functioning lung tissue. We herein review the pretreatment SPECT scans in 86 patients (56 with lung cancer) to determine which are likely to benefit from this technology. METHODS AND MATERIALS: Prior to thoracic XRT, SPECT lung perfusion scans were obtained following the intravenous injection of approximately 4 mCi of 99mcTc-labeled macro-aggregated albumin. The presence of areas of decreased perfusion, their location relative to the tumor, and the potential clinical usefulness of their recognition, were scored. Patients were grouped and compared (two-tailed chi-square) based on clinical factors. Conventional dose-volume histograms (DVHs) (DVFHs) are calculated based on the dose distribution throughout the computed tomography (CT)-defined lung and SPECT-defined perfused lung, respectively. RESULTS: Among 56 lung cancer patients, decreases in perfusion were observed at the tumor, adjacent to the tumor, and separate from the tumor in 94%, 74%, and 42% of patients, respectively. Perfusion defects adjacent to the tumor were often large with centrally placed tumors. Hypoperfusion in regions separate from the tumor were statistically most common in patients with relatively poor pulmonary function and chronic obstructive pulmonary disease (COPD). Considering all SPECT defects adjacent to and separate from the tumor, corresponding CT abnormalities were seen in only approximately 50% and 20% of patients, respectively, and were generally not as impressive. Following XRT, hypoperfusion at and separate from the tumor persisted, while defects adjacent to the tumor improved in several patients. In four patients who achieved a complete response scored by CT with chemotherapy prior to XRT, persistent hypoperfusion was present at and adjacent to the tumor site in three. Among 30 patients with cancers not arising in the lung (14 breast, 12 lymphoma, 4 others), perfusion defects were seen in only 4 (2 adjacent and 2 apart). Recognition of decreases in perfusion mainly impacted on treatment planning for a few patients with poor pulmonary function and limited target volumes. DVFHs have been useful in beam selection for patients with marked perfusion heterogeneities. CONCLUSIONS: Lung perfusion scans provide functional information not provided by CT scans that can be useful in designing radiation treatment beams that minimize incidental irradiation of the function regions of the lung. This approach appears to be most helpful in patients with gross intrathoracic lung cancer, especially those with small targets and relatively poor pulmonary function. One limitation of this approach is that some of the defects adjacent to the tumor site reperfuse following treatment, indicating that these scans identify perfusion rather than potential perfusion. Three dimensional functional data can be used to generate DVFHs that may be more predictive of the physiological consequences of the radiation than conventional DVHs. Additional work is currently underway to test this hypothesis.

Forced Expiratory Volume↗

Study and performance evaluation of statistical methods in image processing.

Two statistical image processing formalisms involving the entropy concept and Bayesian analysis are studied. Iterative imaging algorithms of the formalisms are formulated by employing, for the purpose of performance evaluation and easy implementation, the steepest descent method for the solution of entropy concept and the expectation maximization technique for the solution of Bayesian analysis. Quantitative evaluation and comparison of the convergence performance of the iterative algorithms on computer generated ideal and experimental radioisotope phantom imaging noisy data are given. The study concludes that the entropy algorithm can converge relatively fast, but it is very sensitive to noise in measured data due to the ill-posed nature of inverse problems and its lack of ability to consider the statistics of data fluctuation; while the Bayesian algorithm converges monotonically even with noisy data and has the advantage of considering both the a priori source distribution information and the statistical fluctuation of measured data.

Algorithms↗

Single photon emission computed tomography and its application in the lung.

SPECT systems should affect nuclear medicine because of their ability to eliminate overlying and underlying radionuclide activity, their capacity for total volume imaging, and the increased contrast for lesions, compared with conventional planar imaging and their quantitative potential. The authors offer a preview of the uses of this developing technology in the delineation of perfusion abnormalities.

Animals↗

In vivo regional quantitation of intrathoracic Tc-99m using SPECT: concise communication.

A whole-body single-photon emission computed tomographic system (SPECT) was used to quantitate the activities of a series of Tc-99m point sources in the dog's thorax and to evaluate attenuation of a uniform esophageal line source containing a known concentration of Tc-99m. A first-order attenuation correction and an empirically derived attenuation coefficient of 0.09 cm-1 were used in the SPECT analyses of the intrathoracic point sources. The relationship between SPECT measurements of multiple point-source activities and the same sources measured in air was linear over a range of 100 to 1000 muCi (slope 1.08; R2 coefficient of determination 0.97). These data are sufficiently accurate to allow an estimate of the regional activity of radiopharmaceutical in the dog's thorax and justify their use in experimental quantitation of regional pulmonary perfusion.

Animals↗

Muscarinic cholinergic receptor binding: in vivo depiction using single photon emission computed tomography and radioiodinated quinuclidinyl benzilate.

An attempt was made to characterize, in vivo, specific binding to the muscarinic cholinergic receptor in the calf using the radioiodinated ligand quinuclidinyl benzilate (123I-OH-QNB) and single photon detection emission computed tomography (SPECT). The supratentorial brain activity was significantly increased after the intravenous infusion of 123I-OH-QNB as compared to free 123I. Scopolamine, a muscarinic cholinergic receptor antagonist, decreased the measured brain activity when infused prior to 123I-OH-QNB consistent with pharmacologic blockade of specific receptor binding. Quantitative in vitro tissue distribution studies obtained following SPECT imaging were consistent with regionally distinct specific receptor binding in the striatum and cortical gray matter, nonspecific binding in the cerebellum, and pharmacologic blockade of specific binding sites with scopolamine. Although 123I-OH-QNB is not the ideal radioligand, our limited success will hopefully encourage the development of improved binding probes for SPECT imaging and quantitation.

Animals↗

Single photon emission computed tomography in the canine lung.

A whole body single photon emission computed tomographic system (SPECT) has been used to investigate canine pulmonary perfusion utilizing 99mTc-microspheres and has been compared to conventional radionuclide pulmonary perfusion studies. The SPECT data were reconstructed and displayed in 32 transverse, 16 sagittal, and 16 coronal plane sections, producing additional anatomical information on the pattern of pulmonary perfusion compared to that available with the conventional perfusion scan. The major bronchi, the major blood vessels, and the pulmonary hila are readily seen on the SPECT examination (confirmed anatomically) but are not easily identified on a conventional lung scan. Qualitative assessment of serial SPECT scans established that the distribution and relative concentration of infected radiopharmaceutical was consistent provided the studies had been performed with the animal in the same anatomical position. Changes in the dog's position resulted in a redistribution of radiopharmaceutical such that the most dependent lung contained the greatest concentration.

Animals↗

Simultaneous reconstruction, segmentation, and edge enhancement of relatively piecewise continuous images with intensity-level information.

A multinomial image model is proposed which uses intensity-level information for reconstruction of contiguous image regions. The intensity-level information assumes that image intensities are relatively constant within contiguous regions over the image-pixel array and that intensity levels of these regions are determined either empirically or theoretically by information criteria. These conditions may be valid, for example, for cardiac blood-pool imaging, where the intensity levels (or radionuclide activities) of myocardium, blood-pool, and background regions are distinct and the activities within each region of muscle, blood, or background are relatively uniform. To test the model, a mathematical phantom over a 64 x 64 array was constructed. The phantom had three contiguous regions. Each region had a different intensity level. Measurements from the phantom were simulated using an emission-tomography geometry. Fifty projections were generated over 180 degrees, with 64 equally spaced parallel rays per projection. Projection data were randomized to contain Poisson noise. Image reconstructions were performed using an iterative maximum a posteriori probability procedure. The contiguous regions corresponding to the three intensity levels were automatically segmented. Simultaneously, the edges of the regions were sharpened. Noise in the reconstructed images was significantly suppressed. Convergence of the iterative procedure to the phantom was observed. Compared with maximum likelihood and filtered-backprojection approaches, the results obtained using the maximum a posteriori probability with the intensity-level information demonstrated qualitative and quantitative improvement in localizing the regions of varying intensities.

Algorithms↗

In vivo quantitation of regional cerebral blood flow in glioma and cerebral infarction: validation of the HIPDm-SPECT method.

Iodine-123 labeled hydroxyiodopropyldiamine (HIPDm) is a diffusible indicator with an 85%-90% extraction fraction and stable retention in the brain for more than 2 hr. Equilibrium-phase imaging and quantitation using single-photon emission computed tomographic (SPECT) scanning defined a distribution of HIPDm in proportion to regional cerebral blood flow (rCBF). Studies in calves affirmed a close correspondence (r = 0.97) in calculated rCBF between HIPDm and microspheres using the tissue deposition-arterial input function microsphere methodology. Using this same mathematical analysis in vivo, reproducible rCBF data within the expected range of normal were obtained on repeated studies in the same nonhuman primate. With a diffuse encephalopathy secondary to subarachnoid blood, a bilaterally symmetric decrease in rCBF was present. A prominent focal decrease in HIPDm accumulation and calculated rCBF was noted with cerebral infarction in the distribution of a ligated middle cerebral artery. Patient studies with glioma revealed diminished HIPDm accumulation due to decreased flow and/or pH in the region of the neoplasm as well as in the associated vasogenic edema and overlying gray matter.

Animals↗