Perioperative validation of localisation of the mental foramen.

AIM: To assess the accuracy of panoramic radiography and spiral or computed tomography for the localisation of the mental foramen. MATERIALS AND METHODS: The distance from the alveolar crest to the mental foramen was measured from panoramic radiographs, spiral tomograms and CT scans. The same distance was measured during implant surgery using a specially designed caliper. RESULTS: Panoramic radiography showed more deviation (+0.6 mm) from the perioperative measurements than either spiral or computed tomography (+0.4 and -0.3 mm respectively). The difference was significant (P<0.05). In general, distances were overestimated on the panoramic radiographs. CONCLUSIONS: Cross-sectional imaging techniques are recommended for the pre-operative planning of implants in the posterior mandible.

Adult↗

A comparison of the effective dose from scanography with periapical radiography.

OBJECTIVES: To compare organ and effective doses from analogue scanographic and periapical radiography. METHODS: Thermoluminescent dosimeters (TLD-700) were inserted in the parotid glands (bilateral), submandibular glands (bilateral) and bone marrow (left ascending ramus) of three human cadavers. Dosimeters were also attached to the skin, thyroid gland and lens of both eyes. Central, left lateral and left posterior scanograms were obtained with a Cranex Tome (Soredex, Helsinki, Finland) multimodal imaging system. A similar procedure was applied for periapical radiographs of the midline, left lateral and left molar regions using E-speed film both with and without rectangular collimation. Organ and effective doses were calculated for scanograms and periapical radiographs. RESULTS: The effective doses for the scanograms were 0.001 mSv (central), 0.011 mSv (lateral) and 0.015 mSv (posterior). The effective doses for periapical radiographs were 0.001 mSv (anterior), 0.001 mSv (lateral) and 0.003 mSv (posterior) for rectangular collimation and 0.001 mSv (anterior), 0.002 mSv (lateral) and 0.005 mSv (posterior) for round collimation. CONCLUSIONS: When a larger area of the upper or lower jaw needs to be visualised, scanograms might be considered as an alternative to periapical radiography since the effective dose is lower.

Bone Marrow↗

The accuracy and reliability of radiographic methods for the assessment of marginal bone level around oral implants.

OBJECTIVES: To determine the accuracy and reliability of radiographic methods for assessment of the marginal bone level around oral implants in human cadavers. METHODS: In three human cadavers two implants were placed according to the Instruction Manual for the Brånemark System. One implant was installed in the canine and one in the premolar region of the left mandible. For each implant, conventional and digital intra-oral paralleling radiography were performed. Digital images were printed with a Kodak 1200 Distributed Medical Imaging printer on blue transparent film, glossy and plain paper. Furthermore, digital scanographic, panoramic and tomographic images were taken with the Cranex Tome multimodal X-ray unit and printed on Agfa Drystar TM 1 B transparent films. All images were evaluated by five dental specialists. Data were statistically compared with real measurements of the marginal bone level on the human cadavers, performed by the same group of observers. Intra- and inter-observer variability were determined. RESULTS: Digital intra-oral images on glossy paper showed the smallest absolute difference between real and measured bone level, followed by digital intra-oral images on film and on plain paper, conventional intra-oral images on analogue film, panoramic, scanographic and tomographic images on film. The difference between real and radiographic measurements was not statistically significant (P>0.05) for all radiographic techniques. Intra- and inter-observer reproducibility was high for all techniques. CONCLUSIONS: The selected imaging techniques showed an acceptable accuracy for peri-implant bone level measurements with an overall error of less than 0.5 mm. Intra-oral images showed the smallest absolute differences.

Alveolar Process↗

Risk factors, atherosclerosis, and cardiovascular disease among Aboriginal people in Canada: the Study of Health Assessment and Risk Evaluation in Aboriginal Peoples (SHARE-AP).

BACKGROUND: Little is known about the rates of cardiovascular disease (CVD), atherosclerosis, and their risk factors among Canada's Aboriginal people. To establish the relative prevalence of risk factors, atherosclerosis, and CVD, we undertook a population-based study among people of Aboriginal and European ancestry in Canada. METHODS: We randomly recruited 301 Aboriginal people from the Six Nations Reservation, and 326 people of European origin from Hamilton, Toronto, and Edmonton, Canada. Clinical CVD was defined by history or electrocardiographic findings, atherosclerosis was measured by B-mode carotid ultrasonography, and conventional and new CVD risk factors were measured using standardised methods. FINDINGS: Aboriginal people had significantly more carotid atherosclerosis (mean of the maximum intimal-medial thickness 0.82 (SD 0.20) mm vs 0.78 (0.20) mm, p=0.027), and had a higher frequency of CVD (18.5% vs 7.6%, p=0.00002) compared with Europeans. Aboriginal people had significantly higher rates of smoking, glucose intolerance, obesity, abdominal obesity, and substantially higher concentrations of fibrinogen, and plasminogen activator inhibitor-1. Aboriginal people had significantly higher rates of unemployment and a lower annual household income. For any given income level, Aboriginal people had higher rates of risk factors and CVD compared with the Europeans. INTERPRETATION: A significant proportion of Aboriginal people live in poverty which is associated with high rates of CVD and CVD risk factors. Improvement of the socioeconomic status of Aboriginal people might be a key to reduce CVD in this group.

Adult↗

CD56bright cells differ in their KIR repertoire and cytotoxic features from CD56dim NK cells.

In this study we present new differential characteristics of NK cells expressing CD56 surface antigen in low (CD56dim) or high (CD56bright) density. In contrast to CD56bright NK cells CD56dim cells express killer cell immunoglobulin (Ig)-like receptors (KIR) such as CD158a, CD158b, and NKB1. However, c-type lectin-like receptors (KLR) CD94/NKG2 and CD161 are present on both subsets. The ability to form conjugates with susceptible targets is approximately twice as strongly pronounced in CD56dim vs. CD56bright NK cells. Last but not least, granules of CD56dim cells contain about tenfold more perforin and granzyme A enabling potentially more effective cytolysis compared to CD56bright NK cells. On the other hand, CD56bright NK cells are superior in producing the proinflammatory cytokines IFN-gamma (28.5% vs. 20.8%, p<0.05) and TNF-alpha (28% vs. 15.8%, p<0.001). The different NK cell populations retained their specific phenotype in vitro during culture in the presence of IL-2 contradicting that they simply display different stages of maturity. Taken together our data support the view that CD56bright cells are specialized NK cells that regulate immunological response mechanisms rather by cytokine supply than by their cytotoxic potential. The poor cytolytic capacity of CD56bright NK cells can be explained by weak ability in forming conjugates with target cells and low contents of perforin and granzyme A in their granules.

Antigens, CD↗

An adaptive model of sensory integration in a dynamic environment applied to human stance control.

An adaptive estimator model of human spatial orientation is presented. The adaptive model dynamically weights sensory error signals. More specific, the model weights the difference between expected and actual sensory signals as a function of environmental conditions. The model does not require any changes in model parameters. Differences with existing models of spatial orientation are that: (1) environmental conditions are not specified but estimated, (2) the sensor noise characteristics are the only parameters supplied by the model designer, (3) history-dependent effects and mental resources can be modelled, and (4) vestibular thresholds are not included in the model; instead vestibular-related threshold effects are predicted by the model. The model was applied to human stance control and evaluated with results of a visually induced sway experiment. From these experiments it is known that the amplitude of visually induced sway reaches a saturation level as the stimulus level increases. This saturation level is higher when the support base is sway referenced. For subjects experiencing vestibular loss, these saturation effects do not occur. Unknown sensory noise characteristics were found by matching model predictions with these experimental results. Using only five model parameters, far more than five data points were successfully predicted. Model predictions showed that both the saturation levels are vestibular related since removal of the vestibular organs in the model removed the saturation effects, as was also shown in the e xperiments. It seems that the nature of these vestibular-related threshold effects is not physical, since in the model no threshold is included. The model results suggest that vestibular-related thresholds are the result of the processing of noisy sensory and motor output signals. Model analysis suggests that, especially for slow and small movements, the environment postural orientation can not be estimated optimally, which causes sensory illusions. The model also confirms the experimental finding that postural orientation is history dependent and can be shaped by instruction or mental knowledge. In addition the model predicts that: (1) vestibular-loss patients cannot handle sensory conflicting situations and will fall down, (2) during sinusoidal support-base translations vestibular function is needed to prevent falling, (3) loss of somatosensory information from the feet results in larger postural sway for sinusoidal support-base translations, and (4) loss of vestibular function results in falling for large support-base rotations with the eyes closed. These predictions are in agreement with experimental results.

Adaptation, Physiological↗

The inner ear of dogs with X-linked nephritis provides clues to the pathogenesis of hearing loss in X-linked Alport syndrome.

Alport syndrome is an inherited disorder of type IV collagen with progressive nephropathy, ocular abnormalities, and high-tone sensorineural deafness. In X-linked Alport syndrome, mutations in the COL4A5 gene encoding the alpha5 chain of type IV collagen lead to loss of the alpha3/alpha4/alpha5 network and increased susceptibility of the glomerular basement membrane to long-term damage. The molecular defects that underlie the otopathology in this disease remain poorly understood. We used a canine model of X-linked Alport syndrome to determine the expression of type IV collagen alpha-chains in the inner ear. By 1 month in normal adult dogs, the alpha3, alpha4, and alpha5 chains were co-expressed in a thin continuous line extending along the basilar membrane and the internal and external sulci, with the strongest expression along the lateral aspect of the spiral ligament in the basal turn of the cochlea. Affected dogs showed complete absence of the alpha3/alpha4/alpha5 network. The lateral aspect of the spiral ligament is populated by tension fibroblasts that express alpha-smooth muscle actin and nonmuscle myosin and are postulated to generate radial tension on the basilar membrane via the extracellular matrix for reception of high frequency sound. We propose that in Alport syndrome, the loss of the alpha3/alpha4/alpha5 network eventually weakens the interaction of these cells with their extracellular matrix, resulting in reduced tension on the basilar membrane and the inability to respond to high frequency sounds.

Animals↗

Neuropsychological profile of a 9-year-old child with subcortical band heterotopia or 'double cortex'.

Subcortical band heterotopia (SBH) or 'double cortex', is a congenital brain abnormality that results from aberrant migration of neurons during development of the cortex. MRI shows a continuous band of heterotopic grey matter located between the cortex and ventricular walls, separated from them by a thin layer of white matter. The condition is quite rare, found predominantly in females, and is occasionally familial with an X-linked dominant inheritance. Current research has focused on genetic and neurological correlates, with cognitive assessment restricted to a global measure of general intellectual functioning. This paper describes in detail the results of a neuropsychological assessment of a 9-year-old female recently diagnosed with SBH. Predominant features were a significantly reduced speed of processing for visuomotor and oral output and reduced immediate registration of information. This difficulty has functional implications affecting skill acquisition, learning in the classroom, and social interaction.

Attention↗

Alternative methods to examine hospital efficiency: data envelopment analysis and stochastic frontier analysis.

There has been increasing interest in the ability of different methods to rank efficient hospitals over their inefficient counterparts. The UK Department of Health has used three cost indices to benchmark NHS hospitals (Trusts). This study uses the same dataset and compares the efficiency rankings from the cost indices with those obtained using Data Envelopment Analysis (DEA) and Stochastic Frontier Analysis (SFA). The paper concludes that the methods each have particular strengths and weaknesses and potentially measure different aspects of efficiency. Several specifications should be used to develop ranges of inefficiency to act as signalling devices rather than point estimates. It is argued that differences in efficiency scores across different methods may be due to random "noise" and reflect data deficiencies. The conclusions concur with previous findings that there are not truly large efficiency differences between Trusts and savings from bringing up poorer performers would in fact be quite modest.

Benchmarking↗

Organ radiation dose assessment for conventional spiral tomography: a human cadaver study.

The head of a human cadaver was positioned in a Cranex TOME multifunctional unit (Orion Corporation Soredex, Helsinki, Finland) to measure the organ radiation doses after tomographic examinations of the upper and lower edentulous jaw bone. Five consecutive examinations were carried out in the upper and lower anterior jaw regions to cover the entire frontal area, 2 in the upper and lower left premolar regions, and 3 and 4 in the upper and lower left molar regions, respectively. Each examination consisted of 4 slices with a 2 mm slice thickness. Thermoluminescent dosimeter chips were placed in the thyroid gland and bilaterally in the parotid and submandibular glands. Dosimetric measurements were repeated for the different tomographic examinations mentioned above. For spiral tomography in the maxilla, organ doses for both parotid glands were most elevated, while those for the thyroid glands were the lowest. Average doses per examination reached levels of 0.27 mGy for the right (OS) parotid gland with frontal tomography, and 3.89 mGy and 1.67 mGy for the parotid gland at tube-side (TS) for premolar and molar tomography. For the thyroid gland, a minimal dose of < or = 0.004 mGy was noticed for all examinations. For spiral tomography of the frontal area in the mandible, the OS parotid gland received the highest dose (0.77 mGy), while for an analysis of the premolar and molar areas, doses were more elevated for the TS parotid gland (1.22 mGy and 1.72 mGy, respectively). For the TS submandibular gland, organ doses were also raised, with values of 0.39 mGy for frontal, 1.31 mGy for premolar and 1.61 mGy for molar tomography. This study thus indicates that for conventional spiral tomographic examinations in the maxilla and the mandible, radiation doses for the TS submandibular and parotid glands were significantly more elevated than those to the thyroid gland. These values remain however below the organ doses previously reported for spiral CT involving both a full upper or lower jaw.

Aged↗

Evaluation of speech in patients rehabilitated with various oral implant-supported prostheses.

In the present study, speech function was assessed in edentulous patients wearing fixed or removable dental prostheses supported or not by oral implants. A total of 138 patients participated in the present research. The experimental group (n=113) was divided in 4 subgroups. Subgroup FD/FFPi comprised 22 patients with a maxillary full denture (=FD) and a mandibular fixed full prosthesis on implants (=FFPi). Subgroup FFPi/ND consisted of 27 patients with a maxillary fixed full prosthesis on implants and a natural dentition (=ND) in the mandible. Subgroup FD/ODi included 49 patients wearing a maxillary full denture and a mandibular overdenture on 2 implants (=ODi). Subgroup FFPi/FFPi comprised 15 patients having a fixed full prosthesis on implants in both jaws. The outcome of the logopedic screening of the experimental group was compared with that of a control group of subjects having a natural dentition (ND/ND; n=25). A standard clinical procedure for evaluation of speech was carried out by a speech pathologist. Besides, specific oral and prosthetic parameters were scored in all patients. It was established that one or more pronunciation difficulties occurred in 84% of the patients of the experimental group. This was significantly more than in the control group, where half the number of subjects had some speech deficiencies. No clear influence of specific oral and prosthetic parameters could be identified. From the present results, it could be concluded that in patients rehabilitated with oral implant-supported prostheses speech disorder is more frequently observed than in subjects with a natural dentition.

Adult↗

Localisation of the mandibular canal using conventional spiral tomography: a human cadaver study.

For certain surgical procedures (e.g. placement of implants), an accurate localisation of the mandibular canal is of utmost importance to avoid injuries to the neurovascular bundle. The aim of the present study was to evaluate, on human fresh cadavers (n = 6), the accuracy of conventional spiral tomography for the localisation of the mandibular canal. By means of the Cranex TOME multifunctional unit (Orion Corporation Soredex, Helsinki, Finland), tomographic slices were taken at 3 different locations in the left posterior mandible (distal to the mental foramen). The mandibles were then sectioned at these 3 sites with a microtome. With a digital sliding caliper, the following 3 measurements were performed both on the tomograms and the bone sections at the three sites: 1) distance from the crest to mandibular canal, 2) overall bone height and 3) bone width. Overestimations of the distance to the mandibular canal (8/18) ranged from 1.05 to 0.10 mm and underestimations from 0.30 to 1.36 mm. The same number of over- and underestimations occurred for the bone height (1.14 to 0.14 mm and 0.15 to 1.40 mm, respectively). The bone width scored more overestimations (10/18), ranging from 1.40 to 0.12 mm, while underestimations ranged from 0.25 to 1.35 mm. From the present results, it is concluded that spiral tomography using the Cranex TOME multifunctional X-ray unit provides accurate information and sufficient detail for preoperative planning of implant placement in the posterior mandible.

Algorithms↗

Absorbed doses from spiral CT and conventional spiral tomography: a phantom vs. cadaver study.

For several radiological examinations, a clinician can select between conventional and spiral computed tomography. Using both techniques, this study aimed at evaluating the difference in absorbed doses when examining a single lateral jaw segment in a human cadaver head and Rando phantom. The present study involved the placement of thermoluminescent dosimeter (TLD) chips (GR-200) in the thyroid gland, and bilaterally, in the parotid and submandibular glands and the lenses of the eyes in both a human cadaver and a Rando phantom at corresponding locations. Consecutive conventional spiral tomographic examinations were carried out in both the left upper and lower premolar area, using a Cranex TOME multifunctional unit. Each examination consisted of 4 slices with a 2 mm slice thickness and exposure parameters of 57 kV, 56 seconds and 1.6-2.0 mA. Regarding spiral computed tomography (CT), a Somatom Plus S scanner (Siemens, Erlangen, Germany), with a slice thickness of 1 mm with settings at 120 kV and 165 mA, was used on both phantoms and separately in the upper and lower jaw. With conventional tomography, the findings of the present study showed that the parotid and submandibular glands on the side near the X-ray tube received the highest dose, both for the cadaver head (doses ranging from 0.5 to 1.3 mGy) and the phantom (doses ranging from 0.6 to 2.6 mGy). For CT of the upper jaw, the highest doses were delivered to the parotid glands with an average absorbed dose of 9.2 and 10.6 mGy for the cadaver head and phantom, respectively. The submandibular glands received the highest doses during CT examination of the lower jaw with an average of 7.8 and 12.9 mGy for the cadaver head and phantom, respectively. It appears from the present investigation that if small edentulous regions are examined, radiation doses during conventional tomography remain much lower than during CT imaging. However, when multiple tomographic cuts are required, a spiral CT examination can replace a series of conventional examinations, especially in cases such as the rehabilitation of an edentulous upper jaw or a more complex surgery.

Aged↗

Marginal bone loss around implants retaining hinging mandibular overdentures, at 4-, 8- and 12-years follow-up.

AIM: The aim of the present study was to study the effect of occlusal factors, oral hygiene, gender and age on the long-term maintenance of alveolar bone height around screw-shaped machined surface commercially pure (c.p.) titanium implants retaining hinging mandibular overdentures. METHOD: In this retrospective study a long-term (4-, 8-, up to 12-years) follow-up of such implant-retained overdentures was performed. From the population of patients so treated at the University Hospital of the Catholic University Leuven, Department of Periodontology and Department of Prosthetic Dentistry, 158 patients were selected on the basis of being treated before March 1994, and the availability of intra-oral radiographs (paralleling technique) present at abutment connection (baseline) and at years 4, 8, and 12. For each patient, all relevant clinical data were recorded, and measurements of marginal bone height around the implants were performed on intra-oral radiographs by means of a digital sliding caliper. RESULTS: Results indicated that only the factor "time" had a significant influence on marginal bone loss. The age and gender of the patients, dental/prosthetic status in the antagonistic jaw, oral hygiene variables, and location of the implants had no significant effect. CONCLUSION: The very high cumulative success rate (97.2%) and limited marginal bone loss (on average 1.7 mm) after 12-years, encourage this kind of treatment using this type of implants.

Adult↗

Diagnostic yield of conventional and digital cephalometric images: a human cadaver study.

OBJECTIVES: To compare the clinical efficacy of digital and conventional cephalometric imaging. METHODS: Conventional and photostimulable phosphor cephalometric radiographs were obtained from three human cadavers at nine different exposure settings. Subjective image quality was assessed by six observers who evaluated six cephalometric landmarks. Organ doses were measured with TLDs and effective doses calculated. RESULTS: Compared with conventional cephalometric images, digital images had a consistently better subjective image quality for all exposure settings which was significant (P<0.05) for all but two. Organ doses were comparable. Higher kV and lower mAs settings yielded the lowest effective dose, which was highly dependent on the position of the thyroid gland in the beam. CONCLUSION: Relatively small variations in exposure settings do not influence subjective diagnostic image quality of digital cephalometric radiographs. Higher kV and lower mAs settings have the lowest effective dose and should therefore be preferred.

Cephalometry↗

Organ doses and subjective image quality of indirect digital panoramic radiography.

OBJECTIVES: To determine if slight variations in exposure will affect diagnostic image quality and absorbed radiation doses for digital and analogue panoramic radiography. METHODS: Thermoluminescent dosimeters were placed in the thyroid gland, eyes, submandibular glands, parotid glands and skin of two human cadaver heads. Three different exposure settings were used: 70 kV, 120 mAs; 77 kV, 75 mAs; and 81 kV, 60 mAs. Subjective image quality was assessed using a phantom head. Storage phosphor (SP) images were printed on film and both analogue and SP images were assessed for their subjective image quality on a five-point rating scale. The results were statistically analysed using logistic regression analysis and chi(2) tests. RESULTS: Highest organ doses were measured for the submandibular glands, followed by the parotid glands. Salivary gland doses tended to be higher at lower kV settings. Image quality was not statistically different for the different exposure settings. Imaging technique did not seem to influence diagnostic image quality, except for the periapical status of upper premolars where SP was better. The main reason for any differences appeared to be interobserver variation. CONCLUSIONS: Analogue and SP panoramic radiography performed equally well for subjective diagnostic image quality. No significant differences could be found at the exposure settings used in this study. Radiation doses were highest for the salivary glands, especially at lower kV settings.

Eye↗

Systemic lupus erythematosus and rheumatoid arthritis patients differ from healthy controls in their cytokine pattern after stress exposure.

OBJECTIVE: To study whether patients with rheumatoid arthritis (RA) or systemic lupus erythematosus (SLE) differ from healthy individuals in their immune responses to acute psychological stress. METHODS: The phenotype and function of peripheral blood lymphocytes were analysed before and after stress exposure in patients and healthy subjects. RESULTS: Natural killer (NK) cell numbers increased transiently in all groups under stress. NK activity, however, increased in healthy controls only. We observed a stress-induced increase in interleukin (IL)-4-producing (IL-4(+)) cells in SLE patients only, whereas interferon (IFN) gamma(+) cell numbers increased due to stress in all three groups. An analysis of supernatants from phytohaemagglutinin (PHA) cultures revealed increased IFN gamma and IL-10 levels in healthy subjects but not in SLE or RA patients after stress exposure. CONCLUSIONS: These data demonstrate that RA and SLE patients differ in their immune response to stress from healthy controls. Changes in cytokine patterns might be responsible for stress-induced exacerbation of disease activity in RA and SLE patients.

Adult↗