Search PubMed⌕ Search

Biomedical subjects

R J Pawluk

Publications and source records attributed to R J Pawluk.

At least 19 recordsLinked to original sources

Osteoarthritic changes in the biochemical composition of thumb carpometacarpal joint cartilage and correlation with biomechanical properties.

The biochemical composition and biomechanical properties of articular cartilage from 53 human thumb carpometacarpal (CMC) joints from cadavers aged 20 to 79 years were measured and studied in normal, mildly fibrillated, and advanced osteoarthritic (OA) joints. Statistical analyses were performed to determine the correlations between the compositional measures and biomechanical properties. For these CMC joint tissues we found that water content increased, proteoglycan content decreased, and collagen content per dry weight remained unaltered with progression of OA degeneration. We also found that with disease progression, as defined by an OA staging score, the aggregate modulus (ie, compressive stiffness) decreased, along with an unexpected moderate decrease in permeability. This latter finding appears to be specific to CMC cartilage degeneration since articular cartilage from knees and hips generally demonstrates an increase in permeability with water content and OA score. Correlations between biochemical composition and biomechanical properties were found to be stronger in joints with OA than in joints without OA. This finding suggests that OA changes in biochemical composition, relative to baseline normal values, directly affect the biomechanical properties of cartilage, even though the baseline compositional values themselves do not directly determine the magnitude of the biomechanical properties in normal tissue.

Adult↗

Thenar insertion of abductor pollicis longus accessory tendons and thumb carpometacarpal osteoarthritis.

Although the etiology of osteoarthritis of the thumb carpometacarpal (CMC) joint remains unclear, some theories have focused on variations in the local anatomy of the abductor pollicis longus tendon insertion. This cadaver study of 68 specimens analyzed the relationship between a thenar insertion of an accessory abductor pollicis longus tendon and the presence and severity of thumb CMC osteoarthritis. The joint cartilage surfaces were visually graded for degenerative changes. Thirty-five of 68 specimens (51%) had a thenar insertion, most frequently inserting on either the abductor pollicis brevis or opponens pollicis fascia or muscle belly. No significant association between a thenar insertion and thumb CMC arthritis was observed. Conversely, increasing age was noted to have a significant association with degenerative joint disease. Thus, these findings indicate that a thenar slip of the abductor pollicis longus tendon does not correlate with the presence or severity of CMC osteoarthritis.

Adolescent↗

Topography of the osteoarthritic thumb carpometacarpal joint and its variations with regard to gender, age, site, and osteoarthritic stage.

The articular topography of 46 osteoarthritic thumb carpometacarpal joints was quantitatively analyzed, as well as variations with regard to gender, age, site, and anatomic osteoarthritic stage. It was found that for osteoarthritic thumb carpometacarpal joints, (1) the opposing articular surfaces of elder and severely degenerated joints are more congruent than those of middle-aged and minimally or moderately degenerated joints, although the articular contact area is not significantly different when accounting for thinning of the cartilage layer with age or disease; (2) significant changes in joint topography due to osteoarthritis only occur in severely degenerated joints; (3) joints in women are less congruent, have smaller contact areas, and are likely to experience higher contact stresses than joints in men for similar activities of daily living that involve similar joint loads; and (4) osteoarthritic changes are less severe on the dorsoulnar aspect of the trapezium and the dorsal aspect of the metacarpal, which are known to be low load-bearing regions.

Adult↗

Contact areas in the thumb carpometacarpal joint.

The thumb carpometacarpal joint is a common site of osteoarthritis. It has been hypothesized that peaks of localized stress on the dorsoradial or volar-ulnar regions, or both, of the articular surfaces of the trapezium and metacarpal lead to erosion of cartilage and may be responsible for the progression of the disease. The objective of this study was to determine the contact areas in this joint under the functional position of lateral (key) pinch and in the extremes of range of motion of the joint. These contact areas were assessed relative to the observed sites of cartilage thinning. Eight hands from cadavers of women and five from cadavers of men were tested in vitro with the thumb under a 25 N load in the lateral pinch position, and under small muscle loads (0-5 N) with the thumb in flexion, extension, abduction, adduction, and neutral positions. Contact areas of articular surfaces of the thumb carpometacarpal joint were determined for these positions using a stereophotogrammetric technique. The lateral pinch position produced contact areas predominantly on the central, volar, and volar-ulnar regions of the trapezium and the metacarpal. In three specimens, contact areas were distinctly separated between the dorsoradial and volar-ulnar regions, and in one specimen, from a man, contact occurred exclusively on the dorsoradial region of the trapezium. Using stereophotogrammetry, maps of cartilage thickness also were determined for a subset of nine specimens. The volar-ulnar, ulnar, and dorsoradial regions of the trapezium were the most common sites of thin cartilage, and these may be sites of cartilage wear.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Computer simulation of glenohumeral and patellofemoral subluxation. Estimating pathological articular contact.

Analytic stereophotogrammetry and an interactive computer graphics program were used to obtain first order assessments of joint contact patterns in patellofemoral and glenohumeral joints, simulating normal and abnormal articulations. Precise (90 microns accuracy) computer graphic representations of the humeral head, glenoid, patella, and femoral articular surfaces were obtained from cadaver knees and shoulders. These surface representations were then manipulated into an articulated position, and joint contact areas computed by a proximity criterion. Pathologic states were then simulated, and contact recomputed. Simulated glenohumeral subluxations dramatically reduced contact area, and focused it eccentrically on the glenoid rim. Simulated size mismatch of humeral heads to glenoids reduced contact area, producing a pattern of peripheral contact on the glenoid if the humeral head had a larger radius of curvature, and central contact on the glenoid if the humeral head had a smaller radius of curvature. At 30 degrees knee flexion, the patellofemoral joint demonstrated a broad distribution of contact along the distal aspect of the patella and proximal aspect of the trochlea. Simulated lateral tilt (5 degrees) and translation (5 mm) of the patella resulted in shift of the predominant contact area laterally, along with a drastic decrease in the contact area. These results have implications for prosthetic sizing and biomechanical modeling of the glenohumeral and patellofemoral joints, and in selecting models for more rigorous empiric studies of joint contact. Furthermore, this technique allows a first order assessment of the effects of specific surgical reconstructions on articular mechanics.

Computer Graphics↗

Tensile properties of the inferior glenohumeral ligament.

The tensile properties of the inferior glenohumeral ligament have been determined in 16 freshly frozen cadaver shoulders. The inferior glenohumeral ligament was divided into three anatomical regions: a superior band, an anterior axillary pouch, and a posterior axillary pouch. This yielded 48 bone-ligament-bone specimens, which were tested to failure in uniaxial tension. The superior band was consistently the thickest region, averaging 2.79 mm. The thickness of the inferior glenohumeral ligament decreased from antero-superiorly to postero-inferiorly. The resting length of all three anatomical regions was not statistically different. Total specimen strain to failure for all bone-ligament-bone specimens averaged 27%. Variations occurred between the three regions, with the anterior pouch specimens failing at a higher strain (34%) than those from the superior band (24%) or the posterior pouch (23%). Strain to failure for the ligament midsubstance (11%) was found to be significantly less than that for the entire specimen (27%). Thus, larger strain must occur near the insertion sites of the inferior glenohumeral ligament. Stress at failure was found to be nearly identical for the three regions of the ligament, averaging 5.5 MPa. These values are lower than those reported for other soft tissues, such as the anterior cruciate ligament and patellar tendon. The anterior pouch was found to be less stiff than the other two regions, perhaps suggesting that it is composed of more highly crimped collagen fibers. Three failure sites were seen for the inferior glenohumeral ligament: the glenoid insertion (40%), the ligament substance (35%), and the humeral insertion (25%). In addition, significant capsular stretching occurred before failure, regardless of the failure mode.

Aged↗

Quantitation of in situ contact areas at the glenohumeral joint: a biomechanical study.

Glenohumeral arthritis may result from abnormal articular mechanics, and shoulder reconstructive procedures often rely implicitly on the belief that the restoration of normal articular mechanics is required to obtain satisfactory clinical results. Despite this, limited knowledge of normal or pathologic glenohumeral joint articular mechanics and contact is available. This study uses a stereophotogrammetry technique to determine contact areas in normal cadaver glenohumeral joints with intact ligaments and capsule through a large range of motion using simulated forces of the four rotator cuff muscles and three deltoid heads. All shoulders were first elevated to their maximum elevation in the scapular plane at an external rotation (starting rotation = 40 +/- 8 degrees), which allowed each shoulder to attain its maximal elevation in the scapular plane, and then repeated at 20 degrees internal to this rotation. Contact areas consistently increased with increasing elevation until 120 degrees to an average of 5.07 cm2 before decreasing with further increased elevation to an average of 2.59 cm2 at 180 degrees of total arm elevation. At 20 degrees internal to the starting rotation, contact areas reached high values 60 degrees earlier (averaged 4.56 cm2 at 60 degrees of total arm elevation) and then remained fairly constant through 120 degrees before decreasing with further increased elevation to 2.51 cm2 at 180 degrees total arm elevation. With increasing elevation in the external starting rotation, humeral head contact dramatically migrates from an inferior region to a superocentral-posterior region while glenoid contact shifts posteriorly. When the humeral shaft is positioned 20 degrees internal to the starting rotation, humeral head contact shifts from inferocentral-anterior to superocentral-posterior regions. Simultaneously, a similar posterior shift in glenoid contact is observed. Furthermore, whereas only a small portion of the humeral head surface area is in contact in any given position, contact on the glenoid surface is much more uniformly distributed over its entire articulating surface.

Aged↗

Bioengineering activities at the New York Orthopaedic Hospital Research Laboratory.

The studies described above are representative of the Laboratory's long-standing dedication to the philosophy of multi-disciplinary research. Results from these studies will continue to provide new insights as to the function of diarthrodial joints, articular cartilage and other hydrated soft tissues. It appears reasonable to expect that in the years ahead we will have a better understanding of the mechanisms behind histomorphogenesis, growth, functional adaptation, regeneration, ageing and degeneration of connective tissues and osteoarthritis resulting from these investigations being conducted at the New York Orthopaedic Hospital Research Laboratory.

Biomechanical Phenomena↗

A non-operative salvage of surgically-resistant pseudarthroses and non-unions by pulsing electromagnetic fields. A preliminary report.

This report documents, for the first time, to the authors' knowledge, the therapeutic use in humans of low energy, electromagnetic fields pulsing in the extremely low frequency (E.L.F.) range. These fields, established outside the body, were used to treat congenital and acquired pseudarthroses and non-unions. Energy of this type appears to affect biological processes, not through heat production, but through electrically-induced changes in the environment of cells within the organism. Of the 29 patients included in the study, 17 had experienced at least one failure of surgical repair and, in each of these, amputation had been recommended. The overall success rate, including those patients treated with inadequate pulse characteristics and those who failed to follow the protocol, was in excess of 70 per cent. Improvements in the specificity of pulse characteristics hold promise for increasing the rate of success. The simple, clinical methodology, which is conducted on an out-patient basis, appears to be both safe and effective. It can be applied with or without surgery. This approach requires additional controlled investigations before it is ready for general use in the orthopaedic community. The indications for amputation of surgically-resistant pseudarthroses, however, should be reassessed. The principles and technology, which have been established during this endeavor, may have physiologic and practical significance for processes other than pseudarthrosis and non-union.

Adolescent↗

Augmentation of bone repair by inductively coupled electromagnetic fields.

Pulsing electromagnetic fields of low frequency and strength have been inductively coupled across skin, directly to bone, to enhance the repair of canine osteotomies. The induced voltage field in bone appears to increase the organization and strength of the repair process at 28 days after "fracture."

Animals↗

Electrical behavior of cartilage during loading.

When cartilage is deformed, it becomes electrically polarized. At least two mechanisms seem to underlie this phenomenon, namely, a short-duration, high-amplitude, piezoelectric-like response and a longer-duration, lower-amplitude response secondary to streaming potentials. The polarity of articular cartilage during loading could hypothetically facilitate joint lubrication.

Animals↗