Search PubMed⌕ Search

Biomedical subjects

R J Meijer

Publications and source records attributed to R J Meijer.

At least 19 recordsLinked to original sources

[Modifiable determinants of delayed hospital admission following a cerebrovascular accident].

OBJECTIVE: To identify the modifiable determinants of delayed hospital admission of stroke patients. DESIGN: Multicentre observational study. METHOD: In the period from 1 October 1998 to 31 May 1999, before thrombolysis was an accepted treatment for ischaemic stroke in the Netherlands, we interviewed 252 consecutively admitted patients with stroke upon admission. The patients were asked to describe their symptoms and personal reaction to the stroke event in everyday language. The study was carried out in 14 regional hospitals and one university hospital in the Netherlands. The determinants of delay were calculated by means of multiple linear regression analysis. RESULTS: A total of 252 patients took part in the study: 136 men and 116 women, of whom 130 (52%) were 75 years of age or older. The median time from onset of symptoms to calling in any professional assistance was 60 minutes. The median time from onset of symptoms to arrival at the hospital was 5 hours and 10 minutes. One-third (n = 87; 34%) of the patients reached the hospital within 2.5 hours. Nearly half of the patients (46%) recognised their symptoms as a stroke. Patients who had not recognised their symptoms as a stroke (54%) and patients who had waited until their symptoms had worsened (20%) waited longer before calling in professional assistance than those who did not. Hospital admission was delayed in patients who had waited until their symptoms had worsened, and in those who had first called a family physician (87%). On the other hand, a more rapid admission was achieved in case of referral by the family physician by telephone and also after transportation by ambulance (77%). CONCLUSION: The modifiable determinants of delayed calling for professional help by stroke patients were the fact that they did not recognise the symptoms as a stroke, and the circumstance that they waited until the symptoms would disappear or become worse. This latter circumstance, referral by the family physician by telephone and transportation by ambulance, were modifiable determinants of delayed hospital admission.

Acute Disease↗

Accuracy of eosinophils and eosinophil cationic protein to predict steroid improvement in asthma.

BACKGROUND: There is a large variability in clinical response to corticosteroid treatment in patients with asthma. Several markers of inflammation like eosinophils and eosinophil cationic protein (ECP), as well as exhaled nitric oxide (NO), are good candidates to predict clinical response. AIM: We wanted to determine whether we could actually predict a favourable response to inhaled corticosteroids in individual patients. METHODS: One hundred and twenty patients with unstable asthma were treated with either prednisolone 30 mg/day, fluticasone propionate 1000 microg/day b.i.d. or fluticasone propionate 250 microg/day b.i.d., both via Diskhaler. They were treated during 2 weeks, in a double-blind, parallel group, double dummy design. We measured eosinophils and ECP in blood and sputum, and exhaled nitric oxide as inflammatory parameters before and after 2 weeks in order to predict the changes in forced expiratory volume in 1 s (FEV1), provocative concentration of methacholine causing a 20% fall in FEV1 (PC20 Mch), and asthma quality of life (QOL). Secondly, to test whether these results were applicable in clinical practice we determined the individual prediction of corticosteroid response. RESULTS: We found that changes in FEV1, PC20 Mch and QOL with corticosteroids were predominantly predicted by their respective baseline value and to a smaller extent by eosinophils in blood or sputum. ECP, measured in blood or sputum, was certainly not better than eosinophils in predicting clinical response to corticosteroids. Smoking status was an additional predictor for change in FEV1, but not for change in PC20 Mch or QOL. Prediction of a good clinical response was poor. For instance, high sputum eosinophils (> or = 3%) correctly predicted an improvement in PC20 Mch in only 65% of the patients. CONCLUSION: Our findings show that baseline values of the clinical parameters used as outcome parameters are the major predictors of clinical response to corticosteroids. Eosinophil percentage in blood or sputum adds to this, whereas ECP provides no additional information. Correct prediction of clinical response in an individual patient, however, remains poor with our currently used clinical and inflammatory parameters.

Adolescent↗

Corticosteroid-induced improvement in the PC20 of adenosine monophosphate is more closely associated with reduction in airway inflammation than improvement in the PC20 of methacholine.

It has been suggested in cross-sectional studies that provocation with adenosine 5'-monophosphate (AMP) more closely reflects the inflammatory process in asthma than does provocation with methacholine or histamine. We investigated whether the steroid-induced improvement in the provocative concentration of AMP producing a 20% decline in FEV1 (PC20 AMP) is more closely associated with the concomitant reduction in airway inflammation than is the improvement in PC20 methacholine. In 120 asthmatic patients, we measured PC20 methacholine and PC20 AMP as well as sputum induction and nitric oxide (NO) in exhaled air before and after 2 weeks of treatment with corticosteroids. Improvement in PC20 AMP was solely related to reduction in airway inflammation (i.e., change in the number of sputum eosinophils, lymphocytes, epithelial cells, and concentration of NO in exhaled air). In contrast, improvement in PC20 methacholine was related to both reduction in airway inflammation (i.e., change in the number of sputum eosinophils and lymphocytes) and increase in FEV1 %predicted. The total explained variance of the improvement in bronchial hyperresponsiveness was greater for AMP than for methacholine (36% versus 22%, respectively). We conclude that PC20 AMP is more sensitive to changes in acute airway inflammation than is PC20 methacholine, further reinforcing the notion that PC20 AMP can be a useful tool for monitoring the effects of antiinflammatory therapy.

Adenosine Monophosphate↗

Effect of paracetamol (acetaminophen) on body temperature in acute ischemic stroke: a double-blind, randomized phase II clinical trial.

BACKGROUND AND PURPOSE: Body temperature is a strong predictor of outcome in acute stroke. However, it is unknown whether antipyretic treatment leads to early and clinically worthwhile reduction of body temperature in patients with acute stroke, especially when they have no fever. The main purpose of this trial was to study whether early treatment of acute ischemic stroke patients with acetaminophen (paracetamol) reduces body temperature. METHODS: Seventy-five patients with acute ischemic stroke confined to the anterior circulation were randomized to treatment with either 500 mg (low dose) or 1000 mg (high dose) acetaminophen or with placebo, administered as suppositories 6 times daily during 5 days. Body temperatures were measured with a rectal electronic thermometer at the start of treatment and after 24 hours and with an infrared tympanic thermometer at 2-hour intervals during the first 24 hours and at 6-hour intervals thereafter. The primary outcome measure was rectal temperature at 24 hours after the start of treatment. RESULTS: Treatment with high-dose acetaminophen resulted in 0.4 degrees C lower body temperatures than placebo treatment at 24 hours (95% CI 0.1 degrees C to 0.7 degrees C). The mean reduction from baseline temperature with high-dose acetaminophen was 0.3 degrees C (95% CI 0 degrees C to 0.6 degrees C) higher than that in placebo-treated patients. Treatment with low-dose acetaminophen did not result in lower body temperatures. After 5 days of treatment, no differences in temperature were found between the placebo and the high- or low-dose acetaminophen groups. CONCLUSIONS: Treatment with a daily dose of 6000 mg acetaminophen may result in a small, but potentially beneficial, decrease in body temperature shortly after ischemic stroke, even in normothermic and subfebrile patients. Further studies should determine whether this effect is reproducible and whether early reduction of body temperature leads to improved outcome.

Acetaminophen↗

PC(20) adenosine 5'-monophosphate is more closely associated with airway inflammation in asthma than PC(20) methacholine.

Inhalation of a direct stimulus such as histamine or methacholine is generally used to measure bronchial hyperresponsiveness (BHR). Provocation with adenosine 5'-monophosphate (AMP), an indirect airway challenge, has been suggested to be a better marker of airway inflammation than direct challenges. However, so far little information on this subject is available. The aim of our study was to assess whether the concentration of AMP causing the FEV(1) to drop by 20% (PC(20)) is more closely associated with inflammatory parameters in asthma than PC(20) methacholine. In 120 patients with atopic asthma (median FEV(1) 81% predicted [pred], median age 27 yr), PC(20) methacholine and PC(20) AMP as well as sputum induction, blood sampling, and measurement of nitric oxide in exhaled air were performed. PC(20) methacholine was predominantly predicted by FEV(1) %pred (explained variance [ev] = 18%) with the percentage of peripheral blood monocytes being a weak additional independent predictor (total ev = 23%). By contrast, PC(20) AMP was predominantly predicted by the percentage of eosinophils in sputum (ev = 25%), while FEV(1) %pred was only an additional independent predictor (total ev = 36%). PC(20) AMP reflects more closely the extent of airway inflammation due to asthma than PC(20) methacholine.

Adenosine Monophosphate↗

Effects of inhaled fluticasone and oral prednisolone on clinical and inflammatory parameters in patients with asthma.

BACKGROUND: Guidelines state that oral and inhaled corticosteroids are the cornerstone of asthma treatment. The effect of both types of treatment can be assessed by measuring lung and systemic parameters. Treatment for two weeks with either oral prednisolone (30 mg/day), high dose fluticasone propionate (2000 microg/day, FP2000), or lower dose FP (500 microg/day, FP500), both given by a dry powder inhaler, were compared. METHODS: One hundred and twenty patients with asthma were treated for two weeks in a double blind parallel group design. Lung function, asthma symptoms, airway hyperresponsiveness (PC(20) methacholine and adenosine-5'-monophosphate), sputum eosinophil and eosinophilic cationic protein (ECP) levels were measured as lung parameters. In addition, morning serum blood cortisol, blood eosinophil, and serum ECP levels were measured as systemic parameters. RESULTS: PC(20) methacholine and adenosine-5'-monophosphate showed significantly greater improvement with FP2000 (1.99 and 4.04 doubling concentrations (DC), respectively) than prednisolone (0.90 DC, p = 0.02; 2.15 DC, p = 0. 05) and marginally more than with FP500 (1.69 and 3.54 DC). Changes in sputum eosinophil and ECP concentrations showed similar trends; the decrease in ECP was significantly greater with FP2000 than with FP500. In contrast, the systemic parameters of steroid activity (cortisol, peripheral blood eosinophils, and serum ECP) decreased to a similar extent with FP2000 and prednisolone but significantly less with FP500. CONCLUSIONS: Oral prednisolone (30 mg/day) was inferior to FP2000 in improving airway hyperresponsiveness to both methacholine and AMP, with similar trends in forced expiratory volume in one second (FEV(1)), sputum eosinophil and ECP concentrations. Systemic effects were similar with prednisolone and FP2000 and less with FP500.

Administration, Inhalation↗

Nitric oxide measured with single-breath and tidal-breathing methods in asthma and COPD.

Nitric oxide (NO) can be measured in exhaled air with the single-breath (SB) and tidal-breathing (TB) methods. To allow comparison between different laboratories, a European Respiratory Society task force recently reported guidelines for standardization of both methods. To facilitate comparison between laboratories further, this study investigated whether there is a difference between NO values measured with SB and TB methods in subjects with asthma or chronic obstructive pulmonary disease (COPD), and in healthy subjects. Moreover, the differences between groups were studied and the influence of smoking in asthma was assessed. Sixteen atopic nonsmoking asthmatics, 16 atopic currently smoking asthmatics, 16 nonatopic nonsmoking healthy controls, 16 nonatopic exsmokers with COPD and 16 nonatopic exsmoking healthy controls were studied. NO concentrations differed substantially between both methods. Mean NO concentrations were higher with the SB than with the TB method in nonsmoking and in smoking asthmatics and especially so with the higher NO values. Furthermore, NO values with both methods were higher in nonsmoking asthmatics than in nonsmoking healthy subjects. NO was not significantly different between exsmokers with COPD and healthy exsmokers. In conclusion nitric oxide values of the single-breath and tidal-breathing methods are not interchangeable. Both methods can be used to measure differences between groups.

Adolescent↗

Selective hydrolysis of milk proteins to facilitate the elimination of the ABBOS epitope of bovine serum albumin and other immunoreactive epitopes.

Milk proteins are hydrolyzed to prevent immunological reactions, but immunoreactive epitopes, including the ABBOS epitope of bovine serum albumin (BSA), can still be detected in commercially available milk protein hydrolysates. We used lactococcal cell-envelope proteinase (CEP) for the hydrolysis of the individual milk proteins and of mixtures thereof, or for the hydrolysis of sodium caseinate (contaminated with whey proteins). CEP exclusively degraded casein, leaving the four major whey proteins intact. This property facilitated the removal of the intact whey proteins from the casein fragments by ultrafiltration. Depending on the molecular mass of the whey protein to be removed, membranes with cutoff values between 3 and 30 kDa were used, resulting in casein hydrolysates free of protein fragments with cross-reactive whey-protein-specific IgE (immunoglobulin E) or ABBOS antibody-binding sites. Even the casein itself was degraded in such a way by CEP that cross-reactive casein-specific IgE antibody-binding sites could be eliminated. The product could find application in infant formulas for therapeutic and preventive treatment of children with cow's milk allergy; in addition, the preventive use of such formulas in children genetically susceptible to the development of insulin-dependent diabetes mellitus (IDDM) should be considered if a relationship between the consumption of BSA and IDDM were to become more apparent. The method is also applicable for preparing casein-free whey protein preparations.

Animals↗

Collateral projections from the rat hippocampal formation to the lateral and medial prefrontal cortex.

Projections from the hippocampal formation to the medial prefrontal cortex are well known. In this report we used two retrogradely transported tracers to show that a small but significant subpopulation of pyramidal neurons in area CA1 and subiculum of the hippocampal formation projects to the lateral prefrontal cortex. About half of these neurons also possess collateral projections to the medial prefrontal cortex. The neurons projecting only to the lateral PFC are found in the intermediate hippocampal formation and in the most ventral part of the temporal subdivision. On the other hand, most of the neurons projecting to the medial prefrontal cortex only are present in the temporal and ventral intermediate hippocampal formation, and their number decreases in the dorsal intermediate subdivision. The distribution of neurons having collateral projections is comparable to that of neurons projecting to the medial prefrontal cortex only. In view of proposed functional differences between the septal one-third and the temporal two-third of the hippocampal formation, it is of interest that the neurons projecting to the prefrontal cortex are only present in the temporal two-thirds.

Amidines↗

Comparison of guidelines and self-management plans in asthma.

Since the rise in asthma mortality and morbidity, many guidelines and self-management plans have been published. Many of these guidelines and self-management plans are not, however, based on results of previous studies but on the opinion of experts. We compared the five most frequently cited asthma guidelines concerning treatment steps and self-management plans with special regard to peak expiratory flow (PEF)-guided plans in asthma. We also compared results of published studies with asthma-management in the context of the guidelines. Classification of asthma severity differed considerably between the guidelines. This was also true for PEF-guided patient self-management plans. Although there was agreement on the type of drug to be used, guidelines varied with respect to when to use the drug, the "best" strategy to increase the dose, and the maximum dose. The studies available on self-management do not make it possible to determine which part of the programme is most important or cost-effective. The latter is an important issue.

Asthma↗

Water vapour and carbon dioxide decrease nitric oxide readings.

Measurement of nitric oxide levels in exhaled air is commonly performed using a chemiluminescence detector. However, water vapour and carbon dioxide affect the chemiluminescence process. The influence of these gases at the concentrations present in exhaled air, has not yet been studied. For this in vitro study, mixtures of 50, 100 and 200 parts per billion (ppb) NO in air were prepared and fed into the NO analyser either directly or bubbled through water. Mixtures with CO2 were prepared by adding 0-10% CO2 to the diluent air. We found a significant decrease in NO readings in the water-saturated samples compared to the dry gas (p < 0.001), strongly dependent on the partial pressure of water. NO levels in exhaled air (mean 10 +/- 2 ppb) showed a decrease of 17 +/- 3% when water vapour was not absorbed. From the experiments with CO2 we found a decrease in NO reading of 1.04 +/- 0.07% per volume CO2 (%). Presence of water vapour, thus, leads to a systematic underestimation of NO levels. Insertion of a water absorber might, therefore, be advantageous. The influence of CO2 concentrations in the normal respiratory range is negligible. With high expiratory CO2 levels as applied in permissive hypercapnia, the effects may be substantial.

Carbon Dioxide↗

Incomplete elimination of the ABBOS epitope of bovine serum albumin under simulated gastrointestinal conditions of infants.

OBJECTIVE: Because the bovine serum albumin residues 126-144 (ABBOS) have been reported to be responsible for the autoimmune reaction directed against pancreatic islet cells, it was our aim to study the potential survival of the ABBOS epitope during digestion in the gastrointestinal tract. RESEARCH DESIGN AND METHODS: Either nontreated (commercially available) or heat-treated bovine serum albumin (BSA) was hydrolyzed in vitro with pepsin at a pH of 2.0, 3.0, and 4.0 and subsequently with pancreatic enzymes at a pH of 7.5. Cross-reactivity between the ABBOS peptide and the BSA hydrolysates was determined by competitive enzyme-linked immunosorbent assay (ELISA) using a rabbit polyclonal antibody raised against the ABBOS peptide in BSA. RESULTS: Biochemical findings clearly showed that the degradation of BSA during simulated physiological digestion depended on its conformation and on the pH of its pepsin-catalyzed hydrolysis. Raising the pH of the pepsin-catalyzed hydrolysis from 2.0 to 4.0 decreased the efficiency of the process, especially when BSA had first been denatured by heat treatment. As a consequence, a large proportion of the cross-reactive anti-ABBOS antibody-binding sites was still intact in the final hydrolysates. CONCLUSIONS: The present results suggest that the ABBOS epitope of BSA will not be completely eliminated during digestion under conditions that prevail in the stomach of infants (pH 3-4).

Amino Acid Sequence↗

Home assessment of peak inspiratory flow through the Turbohaler in asthmatic patients.

BACKGROUND: The efficacy of dry powder inhalers depends on the patient's inspiratory flow. Drug delivery from the Turbohaler (Turbuhaler in some countries), a multidose powder inhaler, is optimal at flows of > 40 l/min. The aim of this study was to investigate the peak inspiratory flow that can be generated by asthmatic patients through the budesonide Turbohaler (PIFTBH) during maintenance treatment at home. METHODS: Thirty asthmatic patients, consecutively recruited from the outpatient clinic, inhaled their maintenance dose of 800 (n = 16) or 1600 micrograms/day (n = 14) for two months or one month, respectively. The Turbohaler was connected to a modified Vitalograph Compact installed at home to obtain printed PIFTBH values for all inhalations. Peak expiratory flow (PEF) was measured twice daily. RESULTS: Flows were remarkably constant with individual mean PIFTBH values ranging from 55 l/min to 95 l/min. Only 13 of the 5248 PIFTBH recordings taken at home (three patients) were < 40 l/min and all were > 30 l/min. Weekly mean morning PEF values ranged from 114 l/min to 733 l/min. PIFTBH values could not be accurately predicted from lung function parameters in individual patients. CONCLUSIONS: In a group of stable asthmatic patients inspiratory flow rates rarely fell below the 40 l/min needed to operate a Turbohaler.

Adolescent↗

Detection by competitive enzyme-linked immunosorbent assay of a bovine serum albumin peptide (ABBOS) in infant formulas based on hydrolyzed cow's milk protein.

OBJECTIVE: Our aim was to determine whether currently available products based on hydrolyzed milk protein and a small peptide (ABBOS) in bovine serum albumin (BSA) (positions 126-144) share common antigenic sites. The commercial products are primarily developed to reduce cow's milk protein-associated allergenicity, but whether they also could be used in intervention trials to elucidate the role of BSA in the etiology of IDDM is not known. RESEARCH DESIGN AND METHODS: A sensitive competitive enzyme-linked immunosorbent assay (ELISA) using a rabbit polyclonal antibody raised against the ABBOS peptide in BSA was developed. With this method, we determined cross-reactivity between the ABBOS peptide and commercially available products: four milk protein hydrolysates and eight infant formulas based on hydrolyzed milk protein. The products were further characterized by physicochemical techniques. RESULTS: Hydrolyzed milk protein products are found to inhibit competitively the binding of ABBOS peptide to antibody. The number of residual reactive sites varied considerably among products and was not strongly related to the degree of hydrolysis (DH) or the molecular mass distribution of the hydrolysates. CONCLUSIONS: The presence of possible immunoreactive peptides in infant formulas based on hydrolyzed cow's milk protein cannot be adequately predicted by the DH or molecular mass distribution of the hydrolysates. Its specific determination is needed to ensure infant formulas free of cross-reactive ABBOS antibody binding sites for use in ongoing and forthcoming intervention trials to elucidate the role of BSA as a possible environmental triggering agent of IDDM.

Amino Acid Sequence↗

Residual antigenicity of hypoallergenic infant formulas and the occurrence of milk-specific IgE antibodies in patients with clinical allergy.

BACKGROUND: Milk protein hydrolysates are frequently used in milk substitutes for children with cow's milk allergy. However, cases of hypersensitivity to commercially available hypoallergenic infant formulas based on milk protein hydrolysates have been reported. OBJECTIVE: Our purpose was to determine the immunologic response of milk protein-specific IgE and IgG in the serum of patients allergic to cow's milk against four commercially available hypoallergenic milk protein hydrolysates and eight infant formulas. METHODS: Antibody levels in patients' serum and milk protein-specific residual antigenicity of the hypoallergenic products were determined by indirect and competitive ELISA. RESULTS: Patients allergic to cow's milk had IgE and IgG antibodies to several protein fractions of cow's milk; intraindividual and interindividual variation in the concentrations of these antibodies was considerable. In general, IgE and IgG residual antigenicity of individual milk proteins in the hypoallergenic products was lower compared with that of the intact milk protein, but immunoreactive epitopes could still be detected in all products. Their number varied considerably among the individual milk proteins and also differed among products. CONCLUSIONS: The individual sensitization pattern of the patient allergic to cow's milk and the milk protein-specific residual antigenicity might be considered as possible laboratory predictors of adverse reactions to hypoallergenic products. Their determination could be a useful preclinical screening test for pediatricians to select a formula adapted to the individual patient.

Animals↗