Search PubMed⌕ Search

Biomedical subjects

R Itti

Publications and source records attributed to R Itti.

At least 19 recordsLinked to original sources

[Dosimetry and bone densitometry: examples of LUNAR IQ and HOLOGIC 4500A].

Patient dosimetry related to two bone densitometer units from different manufacturers (LUNAR IQ and HOLOGIC 4500A) were evaluated using the parallel beam technique and thermoluminescence from Ca (SO4)/Dy. The radiation dose measured for a phantom of 18 cm in thickness was 0,11 mGy (+/- 0,004) at a maximum current of 3 mA for the LUNAR IQ unit in the high-resolution mode. The radiation dose is 0,28 mGy (+/- 0,011) for the HOLOGIC 4500A unit used at 2,5 mA in the high resolution-mode. These results obtained by thermoluminescence of the Ca (SO4)/Dy are in favor of the LUNAR IQ unit. However, dosimetry must be weighted against image quality.

Absorptiometry, Photon↗

[The best in 2000 on heart imaging: "the transparent heart"].

Cardiac functional imaging focuses on three variables which complement each other: coronary perfusion reserve (during stress or after maximal vasodilation), myocardial viability (at cellular level) and ventricular contraction (endocardial motion or myocardial thickening). A combination of abnormal findings (location, size and severity) helps to characterise the myocardium in terms of normal, ischaemic, stunned, hibernating or necrosis. This functional information is then used to validate the morphological images of coronary lesions as seen on angiography, to assess the significance of a stenosis, to identify the culprit vessel in cases of multivessel disease, and to delineate the area at risk. "Non-invasive" techniques should no longer be considered only as screening methods with more sophisticated investigations in view, but should replace them at every step of patient management: at the time of diagnosis, with a "positive/negative" bayesian approach, before a therapeutic decision and during follow-up, especially when considering the prognosis of patients and risk stratification when the quantitation of functional abnormalities are major determinants.

Coronary Circulation↗

In vivo measurement of myocardial oxidative metabolism and blood flow does not show changes in cancer patients undergoing doxorubicin therapy.

PURPOSE: The aim was to investigate in patients receiving doxorubicin whether any alteration in myocardial oxidative metabolism or blood flow as assessed by positron emission tomography (PET) could be observed either after the first dose of the drug, or during its chronic administration. METHODS: Six female non-heart-failure cancer patients treated with doxorubicin were included in a longitudinal study. Resting radionuclide cineangiography and PET scanning with carbon-11 acetate were performed the day before the initiation of doxorubicin treatment at a dosage of 50 mg/m2 every 3 weeks, and 3 weeks after the cumulative administration of 300 mg/m2 (chronic toxicity). In addition, PET was performed 24 h after the first administration of doxorubicin (evaluation of acute toxicity). Myocardial oxidative metabolism and blood flow were assessed by PET (acute and chronic toxicity), and left ventricular ejection fraction was measured by radionuclide angiography (chronic toxicity). RESULTS: Using PET for both acute and chronic toxicity evaluations, no significant effect of doxorubicin was observed either on the flux through the tricarboxylic acid (TCA) cycle or on myocardial blood flow. However, systolic left ventricular function showed a small but significant impairment after the administration of 300 mg/m2 of doxorubicin. CONCLUSIONS: Other hypotheses should be explored to better explain the predominant mechanisms of the cardiotoxicity of anthracyclines in humans.

Aged↗

Severity and extent of perfusion defects provoked by transient coronary occlusion compared with myocardial damage observed after infarction.

A peripheral perfusion tracer injection at the time of coronary occlusion during percutaneous transluminal coronary angioplasty (PTCA) may delineate the myocardial 'area at risk' related to a given artery. To evaluate the location, size and severity of the corresponding scintigraphic defects, we conducted a prospective study of 36 patients who received a 99Tcm-sestamibi injection during single-vessel coronary angioplasty (PTCA = 18 LAD, 16 RCA and 2 LCX) followed by SPET. For comparison, a reference group of 36 successive patients examined during the early phase of myocardial infarction (MI), matched for the same vascular territories (18 anterior, 16 inferior and 2 lateral), were analysed in the same way after standard stress/reinjection 201Tl SPET. The imaging characteristics of both groups showed excellent agreement as well degree of uptake defects, in terms of topography and extent. A defect index, taking into account both size and severity, was in the same range for PTCA and MI patients (mean +/- standard deviation): for LAD vs anterior = 28.4 +/- 13.5% (PTCA), 27.1 +/- 12.2% (MI-stress) and 24.2 +/- 10.0% (MI-reinjection); for RCA vs inferior = 15.5 +/- 10.2% (PTCA), 14.7 +/- 9.7% (MI-stress) and 13.2 +/- 8.2% (MI-reinjection). Sectoral correlations between PTCA and MI groups were also highly significant.

Adult↗

Three-dimensional automatic image warping in cardiac SPECT.

This study presents a new tool for the visualization and analysis of three-dimensional (3-D) cardiac single-photon emission computed tomography (SPECT). The first step consisted of computing the 3-D pseudo-skeleton of a binarized myocardium and, using the skeleton points, to design a bullet model (half ellipsoid prolonged by a cylinder). Afterwards, this model was used to drive the warping of the 3-D myocardium, initially egg-shaped, into a thick, flat disc using the thin-plate splines as deformation method. Hence, instead of achieving several rotations of the initial egg-shaped volume to have an idea on the myocardial outer face (epicardial) only, the whole myocardium is seen by looking either on top of the disc-shaped transformed myocardium (epicardial surface) or underneath for the inner face (endocardial). This new shape permitted us to localize any type of defect and to evaluate its extent and depth just by a single glance. A detailed analysis, achieved after stripping away this shape in about 10 layers, allowed us to evaluate the defect extent layer by layer and to determine whether the defect involves the totality of the myocardium layers. Finally, its flattening following the ventricular long-axis led to a summed bull's eye.

Algorithms↗

Gated blood-pool SPECT evaluation of changes after radiofrequency catheter ablation of accessory pathways: evidence for persistent ventricular preexcitation despite successful therapy.

OBJECTIVES: This study was designed to prospectively evaluate the effects of radiofrequency ablation in Wolff-Parkinson-White (WPW) syndrome by scintigraphic analysis. BACKGROUND: The functional changes triggered by radiofrequency current ablation of atrioventricular accessory pathways are not fully known. METHODS: Forty-four patients with WPW syndrome were consecutively investigated before and 48 h after radiofrequency therapy. Fourteen patients had right sided atrioventricular pathways and 30 patients had left sided bypass-tracts. Planar gated imaging and gated blood pool tomography were performed in all of these patients. RESULTS: A significant increase in the left ventricular ejection fraction (LVEF) was demonstrated in patients with left preexcitation (62.2+/-7.9% before ablation against 64.4+/-6.3% after ablation, p = 0.02) but not for those with right sided anomalous pathway. Phase analysis only gave significant differences following ablation of right sided pathways (left-to-right phase difference = 14.4+/-13.8 degrees before ablation versus 7.5+/-7.2 degrees after ablation, p<0.05). Early abnormal ventricular contraction persisted in 12 patients with right accessory pathways and in 8 patients with left accessory pathways despite the complete disappearance of any abnormal conduction as proven electrophysiologically. CONCLUSIONS: Following catheter ablation of atrioventricular accessory pathways: 1) an improvement of left ventricular function may be seen, particularly in patients with left sided accessory pathways, and 2) unexpected persistence of local ventricular preexcitation at the site of successful ablation may be detected.

Adult↗

Two-year assessment by exercise thallium scintigraphy of myocardial revascularization using bilateral internal mammary and gastroepiploic arteries.

OBJECTIVE: To assess the blood flow supply offered to the myocardium by surgical revascularization using bilateral internal mammary (IMAs) and gastroepiploic (GEA) arteries. METHODS: Two-year assessment by exercise thallium myocardial scintigraphy without medical treatment was performed in 122 patients (mean age 61 +/- 9 years) who underwent coronary artery bypass grafting (CABG) with exclusive use of IMAs and GEA. Usually, the right IMA was used to bypass the left anterior descending coronary artery, and the left IMA to bypass the diagonal and the marginal arteries as a sequential graft if required. The GEA was used to bypass the right coronary artery (RCA) in 50 patients and its posterior branches in 72 patients. RESULTS: During maximal or submaximal exercise stress testing, 119 patients (98%) were asymptomatic and 26 patients (21%) exhibited moderate ischemic ECG modifications which were correlated (P < 0.01) with incomplete revascularization and with the use of GEA to bypass the RCA. A third of patients had moderate ischemic thallium defects on exercise reversible after redistribution (anterior, 10; lateral, 2; inferior, 28). Silent residual myocardial ischemia detected by thallium scintigraphy was correlated (P < 0.001) with ECG modifications and incomplete revascularization; and inferior thallium defects were more frequent when GEA bypassed the RCA (P < 0.05). However, 26% of patients had residual ischemia despite a complete revascularization, and in at least 18% of cases for GEA and 8% for right IMA, arterial graft blood flow was insufficient at maximum exercise level and caused silent residual myocardial ischemia detected by thallium scintigraphy. CONCLUSIONS: Myocardial revascularization using bilateral IMAs and GEA offers a satisfactory myocardial perfusion in the majority of cases; however silent residual myocardial ischemia was detected in a third of patients and was related to incomplete revascularization and to insufficient blood flow supply probably due to small diameter of the arterial grafts.

Adult↗

Effects of lipid-lowering drugs on left ventricular function and exercise tolerance in dyslipidemic coronary patients.

Previous studies suggested that certain lipid-lowering drugs such as statins suppress ubiquinone, affect mitochondrial function, and may have deleterious effect on skeletal or cardiac muscles with potentially serious clinical consequences, especially in patients with established coronary heart disease and left ventricular dysfunction. In this double-blind study, we assessed the effects of 20 mg simvastatin (S, n = 32) or 200 mg micronized fenofibrate (F, n = 32, control group) on rest and exercise left ventricular function in hypercholesterolemic survivors of a previous Q-wave acute myocardial infarction. Left ventricular radionuclide imaging was performed at rest and during submaximal exercise and global and segmental (nine segment regional wall-motion score) ejection fractions were measured before treatment and 12 weeks later. Serum ubiquinone was reduced after treatment (p = 0.03) in the S but not the F group, whereas total and low-density lipoprotein (LDL) cholesterol were significantly reduced in both groups. Before treatment, mean global ejection fraction was 52.1+/-12.2% and 49.3+/-11.8% at rest in F and S patients, respectively, and increased (56.0+/-13.7% in F and 52.1+/-12.9% in S) at peak exercise (no difference between groups). After treatment, the increase in ejection fraction tended to be lower in S (0) than in F (+3.8%) but not significantly. However, ejection fraction at rest increased after treatment in S (p = 0.009) but not in F. Subgroup analyses indicated that the improvement in rest ejection fraction in S was essentially observed in patients with ejection fraction <40% (n = 8, +6%), whereas it was stable in patients with ejection fraction >40% (+1.8%). Finally, the numbers of akinetic or hypokinetic segments at rest and during exercise were not different in the two groups before and after treatment. Mean maximal exercise load (113+/-23 watts in F vs. 104+/-27 W in S before treatment) was not modified by the treatment (111+/-21 and 104+/-27 W). Thus a 12-week lipid-lowering treatment with either S or F did not negatively alter left ventricular function during exercise in dyslipidemic patients with established coronary heart disease and did not affect their ability to exercise. The improvement in left ventricular function at rest after simvastatin in patients with left ventricular dysfunction warrants confirmation in further studies with large sample size.

Blood Pressure↗

Does the extended use of arterial grafts compromise the myocardial recovery after coronary artery bypass grafting in left ventricular dysfunction?

OBJECTIVE: To assess the prognostic factors of myocardial recovery expected after coronary bypass surgery and the impact of surgical technique used, a prospective non-randomized study including a 1-year postoperative evaluation of left ventricular function was performed in patients with left ventricular dysfunction (left ventricular ejection fraction (LVEF) < 0.40). METHODS: From 1993 to 1996, 110 patients (mean age 61+/-11 years) were included in the study. The mean LVEF was 31+/-6%. All patients had preoperative radionuclide investigations based on the combination of stress/reinjection thallium single photon emission computed tomography (SPECT) and planar evaluation of LVEF; 88% of patients had reversible ischemic thallium defects. Two surgical technique were used: 53 patients received the left internal mammary artery with associated sequential vein graft, and 57 patients received only arterial grafts, internal mammary and gastroepiploic arteries. The mean number of distal anastomoses was 3.2+/-0.8 and 54% of patients had complete revascularization. At 1 year, all survivors had clinical evaluation and the same radionuclide investigations. RESULTS: The early mortality was 2.7%. At 1 year, 100 patients were surviving; on average, NYHA class decreased 1.9+/-0.8 to 1.4+/-0.6 (P < 0.01) and CCS class from 2.8+/-0.6 to 1+/-0.3 (P < 0.01). The mean LVEF increase from 31+/-9 to 34+/-10% (P < 0.01) and the mean LV end-diastolic volume decreased from 317+/-112 to 285+/-108 ml (n.s.). The postoperative improvement in LV function was higher in patients in NYHA class 3 or 4 before surgery (P < 0.05), when associated sequential vein graft had been used (P < 0.01), and in patients with low preoperative LVEF (P < 0.01). The postoperative LVEF improvement observed was significantly correlated with the improvement in left ventricular end-diastolic (LVED) volume and the improvement in redistribution/reinjection thallium uptake. Multivariate analysis showed that the surgical technique used and the preoperative LVEF were independent prognostic factors of the postoperative myocardial function recovery, with a significant positive impact of the vein use. CONCLUSION: This study confirms the excellent clinical results of coronary artery bypass grafting (CABG) in patients with coronary artery disease and LV dysfunction; improvement in LV function can be documented objectively and is correlated with reperfusion of hibernating myocardium. However, the extended use of arterial grafts does not allow to achieve the significant myocardial recovery observed with the use of one internal mammary artery (IMA) and associated sequential vein graft; it seems to be related to the preoperative selection of patients, but a direct negative impact of arterial grafts was documented and leads to be cautious in patients with severe LV dysfunction.

Abdominal Muscles↗

Risk stratification after myocardial infarction. A reappraisal in the era of thrombolysis. The Groupe d'Etude du Pronostic de l'Infarctus du Myocarde (GREPI)

OBJECTIVES: The present study was performed to evaluate whether the modalities of risk stratification after myocardial infarction were still operative in the thrombolytic era. BACKGROUND: Prediction of fatal events in the aftermath of myocardial infarction relies on tests which aim to assess myocardial function, residual ischaemia and propensity for ventricular arrhythmias. Recent data on improved myocardial infarction prognosis have led to the view that risk stratification needs to be updated. METHODS: In this multicentre, prospective study, 471 acute myocardial infarction patients, 45% of whom were given thrombolytic therapy, were enrolled from the 10th day and underwent all or part of the following tests exercise test, radionuclide ventriculography (resting and exertional ejection fraction). Holter monitoring, signal-averaged electrocardiography and programmed electrical stimulation. Univariate and multivariate analyses were performed to identify predictors of mortality. RESULTS: One year and long-term (mean follow-up 31.4 months) mortality rates were 5.5% and 8.4%, respectively. Prediction of mortality was assessed and the role of the following variables was thus determined: age over 56 years (P = 0.01), previous coronary attacks (P < 0.001), history of heart failure (P < 0.001), early heart failure after myocardial infarction (P = 0.017), maximum workload of lest than 120 W at exercise test (P = 0.014), ineligibility to perform exercise (P = 0.002), depressed left ventricular ejection fraction (P = 0.013), late potentials as identified using 50 Hz high pass filtering (P = 0.012), mean night-time cycle length of less than 750 ms (P < 0.001), standard deviation of day time RR intervals of less than 100 ms (P = 0.04), the last two measures reflecting heart rate variability. In this population, neither ventricular ectopic activity nor inducibility of sustained monomorphic ventricular tachycardia at electrophysiological study carried any prognostic significance. Multivariate analyses showed that decreased heart rate variability, presence of late potentials and low ejection fraction (< 30%) made an independent contribution to the survival models. CONCLUSION: In the current context of management of acute coronary patients, the basis for risk stratification after myocardial infarction remain roughly unchanged.

Adult↗

Tomographic myocardial imaging with technetium-99m tetrofosmin. Comparison with tetrofosmin and thallium planar imaging and with angiography.

Technetium-99m tetrofosmin is a new myocardial imaging agent with improved handling and kinetic characteristics. The purpose of this study was to compare the ability of planar and SPECT Tc-99m tetrofosmin imaging with Thallium-201 planar data to detect coronary artery disease and individual vessel lesions ( > 50% diameter stenosis). Seventy-two patients with definite or suspected coronary artery disease were included. Sixty-three had angiographic evidence of coronary artery disease, among whom 42 had had a previous myocardial infarction, while 21 had not. The total number of diseased arteries was 111. Patients underwent symptom-limited treadmill or bicycle exercise to similar endpoints. Thallium and tetrofosmin images were analysed separately by consensus reading. Interpretation was made for five standard anatomical regions (anterior, septal, inferior, lateral and apex), classified into four categories (normal, reversible, fixed and mixed defects). Sensitivity and specificity to detect coronary artery disease were 71% and 78% for Thallium-201 vs 68% and 78% for tetrofosmin by planar imaging, and 87% and 89% for tetrofosmin by SPECT. The improved sensitivity of SPECT was confirmed both in patients with and without previous myocardial infarction. The sensitivity to detect individual vessel lesions was improved by SPECT (59% tetrofosmin SPECT vs 50% thallium planar and 51% tetrofosmin planar). Individual vessel lesion detection by SPECT was 50% for the left anterior descending coronary artery, 42% for the left circumflex and 86% for the right coronary artery. This study confirms the value of technetium-99m tetrofosmin as a myocardial imaging agent. Improvements in diagnosis and in evaluating extent of disease can be expected from using SPECT.

Adult↗

Automated detection of the left ventricular region in gated nuclear cardiac imaging.

An approach to automated outlining the left ventricular contour and its bounded area in gated isotopic ventriculography is proposed. Its purpose is to determine the ejection fraction (EF), an important parameter for measuring cardiac function. The method uses a modified version of the fuzzy C-means (MFCM) algorithm and a labeling technique. The MFCM algorithm is applied to the end diastolic (ED) frame and then the (FCM) is applied to the remaining images in a "box" of interest. The MFCM generates a number of fuzzy clusters. Each cluster is a substructure of the heart (left ventricle,...). A cluster validity index to estimate the optimum clusters number present in image data point is used. This index takes account of the homogeneity in each cluster and is connected to the geometrical property of data set. The labeling is only performed to achieve the detection process in the ED frame. Since the left ventricle (LV) cluster has the greatest area of the cardiac images sequence in ED phase, a framing operation is performed to obtain, automatically, the "box" enclosing the LV cluster. THe EF assessed in 50 patients by the proposed method and a semi-automatic one, routinely used, are presented. A good correlation between the two methods EF values is obtained (R = 0.93). The LV contour found has been judged very satisfactory by a team of trained clinicians.

Algorithms↗

Myocardial perfusion imaging with 99mTc tetrofosmin. Comparison to 201Tl imaging and coronary angiography in a phase III multicenter trial. Tetrofosmin International Trial Study Group.

BACKGROUND: Our objective was to compare the sensitivity and specificity of tetrofosmin, a new 99mTc-labeled myocardial perfusion imaging agent for the detection of myocardial perfusion abnormalities, with those of 201Tl and coronary angiography. Our hypothesis was that same-day stress/rest tetrofosmin imaging could provide data comparable to those of 201Tl imaging. Myocardial perfusion imaging plays an important role for the evaluation of coronary artery disease. Newer 99mTc-labeled agents offer several advantages over 201Tl, the conventional myocardial perfusion imaging agent. Tetrofosmin is a new 99mTc-labeled agent with promising results in preliminary studies. METHODS AND RESULTS: Two hundred fifty-two patients with suspected coronary artery disease were enrolled in 10 centers in the United States and Europe. All patients underwent exercise and rest myocardial perfusion imaging with 99mTc-tetrofosmin using two separate injections of the radiotracer 4 hours apart on the same day. Planar images were obtained in three standard views 15 to 60 minutes after radiotracer injection. Patients also underwent standard exercise and redistribution planar 201Tl imaging within 2 weeks of tetrofosmin imaging. In addition, 58 healthy subjects with low likelihood of coronary artery disease underwent exercise and rest tetrofosmin imaging. Coronary angiograms were available in 181 patients with suspected coronary artery disease. All radionuclide images were processed in the central core laboratory and interpreted blindly by a panel of four experienced readers. 201Tl images and tetrofosmin images were read separately. Discrepancies were resolved by consensus. The workload, peak heart rate, and double products were comparable during exercise for both imaging agents. Technically acceptable paired 201Tl and tetrofosmin images were available in 224 of 252 patients. Tetrofosmin images were generally of good quality, with low extracardiac activity, and easy to interpret. Patients were categorized as showing normal, ischemia, infarction, or mixture with each imaging modality. Precise concordance for each of these categories was 59.4% (kappa = 0.44; 95% CI, 0.35 to 0.53). When patients were categorized as normal or abnormal, the concordance was 80.4% (kappa = 0.55; 95% CI, 0.43 to 0.67). When each of five anatomic territories (septal, anterior, inferior, lateral, and apical) was categorized as normal versus abnormal, the concordance varied from 81% to 90%. When similar comparison was made for the specific category of abnormality, the concordance was 64% to 84%. When coronary angiography was used as the criterion, the sensitivity and positive and negative predictive accuracy of tetrofosmin and 201Tl were comparable. The normalcy rate of tetrofosmin images in the healthy subjects with low likelihood of coronary artery disease was 97%. CONCLUSIONS: 99mTc tetrofosmin is a new myocardial imaging agent with favorable imaging characteristics with results comparable to those of 201Tl.

Adult↗

Risk and results of bypass grafting using bilateral internal mammary and right gastroepiploic arteries.

From January 1990 to June 1994, 240 patients (mean age, 60 +/- 10 years) underwent myocardial revascularization with the exclusive use of in situ bilateral internal mammary and right gastroepiploic arteries. Left ventricular function was normal in 34% of patients, moderately impaired in 58.5%, and severely impaired in 7.5%. The mean number of distal anastomoses was 3.5 +/- 0.7 and the rate of complete myocardial revascularization was 80%. Early mortality was 0.4%, and complications occurred in 20 patients: myocardial infarction, 1.6%; intraaortic balloon pump, 0.8%; reoperation for bleeding, 0.8%; and mediastinitis, 0.4%. Early (15th postoperative day) angiographic control of grafts was performed in 51 patients; the rate of functional and patent anastomoses was 100% for internal mammary arteries and 96% for gastroepiploic arteries. Early functional results (3 +/- 1 postoperative months) were studied in 141 patients during exercise test with medical treatment: 99% were symptom-free and 14% had ischemic modification of electrocardiograms. A 2-year postoperative functional assessment without medical treatment was performed during exercise test in 66 patients: 98% were symptom-free and 26% had ischemic modification of electrocardiograms; during the same procedure, thallium myocardial scintigraphy was obtained in 50 patients and 18 patients had moderate ischemic defect on exercise. Ischemic modifications of electrocardiograms and defects seen on thallium scintigraphy were correlated significantly with incomplete revascularization (p < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Abdominal Muscles↗

Technical aspects and late functional results of gastroepiploic bypass grafting (400 cases).

From January 1990 to February 1994, 400 patients (mean age 59 +/- 9 years) underwent myocardial revascularization using the right gastroepiploic artery (GEA) to bypass the right coronary artery trunk or branches. They represented 40% of all patients undergoing isolated coronary surgery during the same period, from 19% in 1990 to 54% in 1994. Left ventricular function was normal in 32% of patients, moderately impaired in 62% and severely impaired in 6%. The GEA was used alone in six patients, associated with one internal mammary artery (IMA) in 111 patients (two arterial grafts, 2.2 +/- 0.4 anastomoses) and with both IMAs in 283 patients (three arterial grafts, 3.4 +/- 0.6 anastomoses); no vein graft was used. The rate of complete myocardial revascularization was 79%. Early mortality was 1.7% and influenced by left ventricular ejection fraction (P < 0.05). Complications occurred in 37 patients: myocardial infarction 4%, intra-aortic balloon pump 0.5%, reoperation for bleeding 0.5%, mediastinitis 0.25%. Early (15th postoperative day) angiographic control of the GEA graft was performed in 104 patients operated from January 1990 to December 1991 and the patency rate was 92%; anomalies of GEA were three occlusions, five stenoses, three competitive flow, no string or slender sign. Early functional results (3 +/- 1 months postoperatively) were studied in 192 patients during exercise test with medical treatment: 99% were symptom-free and 14% had electrocardiographic (ECG) ischemic modification significantly correlated with incomplete revascularization (P < 0.01). The 2- and 4-year actuarial survival rate was 96.7 +/- 1.9%. The rate of late cardiac events was 2% patient/year; Angioplasty for GEA graft failure was required in four patients. A 2-year postoperative functional assessment without medical treatment was performed during exercise test in 66 patients who had received three arterial grafts: 98% were symptom-free and 26% had ECG ischemic modification significantly correlated with incomplete revascularization (P < 0.01); during the same procedure, thallium myocardial scintigraphy was obtained in 50 patients: 18 patients (36%) had asymptomatic ischemic defects on exercise significantly correlated with incomplete revascularization and ECG ischemic changes (P < 0.01). However, posterior thallium defects demonstrated limited GEA flow at the maximum level of exercise in at least 8% of patients. Myocardial revascularization using the GEA can be achieved with minimal operative risk and offers satisfactory functional results and midterm survival rate.

Adult↗

[Preliminary study of an implantable device powered by an inductive link for telemetry of the epicardial electrocardiogram and the radionuclide activity of the left ventricle].

In nuclear cardiology, radionuclide data concerning the cardiac function are presently collected using external detectors, providing scintigraphic images or activity curves with respect to time. This paper presents a new approach to the latter kind of instruments, which are often called nuclear stethoscopes. This proposed system is composed of a cardiac implant, a miniature transmitter positioned externally on the chest and a remote receiver system allowing the processing of the cardiac function data. The transcutaneous magnetic link permits the power transfer in order to energize the electronic implant, and permits the telemetry of the electrocardiogram and the radionuclide data between the implant and the external receiver system. The nuclear activity measured by a photodiode for gamma rays based on cadmium telluride, with pulse width modulation, constitutes the carrier of the electrocardiographic activity. The composite signal is transmitted by means of the implant impedance modulation. The use of this transmission concept reduces to a minimum the volume of the implant. Furthermore, this system, allowing the correct positioning of the external transmitter facing the left ventricle, increases the performance of the global transmission system. Theoretical results on the design of the magnetic link are presented.

Electrocardiography↗

[Radionuclide ejection fraction at rest and in exercise in chronic aortic insufficiency. Pre- and postoperative study in asymptomatic or paucisymptomatic patients].

Twenty patients (17 men and 3 women: average age 50 +/- 14 years) with asymptomatic or paucisymptomatic aortic regurgitation were studied to compare the values of radionuclide left ventricular ejection fraction (EF) at rest and on exercise before (1) and 6 +/- 1 months (2) and 5.7 +/- 1.1 years (3) after surgery. The resting EF was similar at all three examinations: 53 +/- 8 (1); 57 +/- 8 (2); 55 +/- 16 (3). However, it increased significantly on exercise from 40 +/- 10 (1) to 54 +/- 12 (2) (p < 0.001) and to 52 +/- 20 (3) (p = 0.036 versus 1). In the 7 patients with resting EF greater than 55 before surgery, there was no postoperative improvement: 61 +/- 6 (1); 61 +/- 5 (2); 65 +/- 9 (3). However, the exercise EF increased from 44 +/- 13 (1) to 55 +/- 17 (2) and 69 +/- 11 (3) (p = 0.004 vs 1). In 13 patients with resting EF < 55%, the value increased in the early postoperative phase but not later: resting: 49 +/- 5 (1); 55 +/- 8 (2) (p = 0.04); 49 +/- 17 (3) (NS vs 1); effort: 38 +/- 7 (1); 54 +/- 10 (2) (p < 0.001); 40 +/- 16 (3) (NS vs 1). Left ventricular systolic function only returns to normal and exercise after surgery in patients with resting preoperative EF > or = 55%, but nothing indicates that this normalisation is an absolute condition for a successful surgical result in aortic insufficiency in terms of survival and quality of life.

Adult↗