Interface stresses in the resurfaced hip. Finite element analysis of load transmission in the femoral head.

The load transmission and interface stresses in the Wagner resurfaced femoral head were evaluated for the purpose of studying possible failure mechanisms. We found that unnatural stress patterns occur in the head and at the implant-bone interfaces, in addition to regions of stress protection in the bone, possibly enhancing interface failure and bone remodelling. However, these stresses are not higher than those reported for other kinds of prostheses, e.g. acetabular cup, tibial plateau. From these findings, together with clinical observations, it is hypothesized that the femoral surface cup is more sensitive to local loosening than other prostheses. This hypothesis would indicate that prosthetic designs should be analysed relative to their potential to provoke failure propagation, rather than only initiation of mechanical failure and loosening.

Bone Cements↗

Local stresses and bone adaption around orthopedic implants.

The severest long-term complications of orthopedic joint-prostheses are associated with loosening of the implant-bone interface, due to adverse reactions in bone and subsequent weakening of the connection between the two materials. Mechanical stresses, caused by joint loading, play a key role in the adaption of interface bone and in the loosening process. In the present study, it is shown how local interface stress patterns can be evaluated using advanced methods of computer-based, engineering stress analyses (the Finite Element Method, FEM). The stress patterns are compared with the local bone structure and bone resorption phenomena as found in animal experiments. The results indicate that loosening and bone resorption is associated with high peak stresses at the interface in the immediate post-operative stage. In addition, there appears to be similarity between the local stress patterns and the bone morphology at the interface if resorption does not occur. Finally, it is found that implants of high local stiffness generate lower peak stresses in bone, as compared with low stiffness implants.

Animals↗

Bone grafting in total hip replacement for acetabular protrusion.

Total hip replacement combined with acetabuloplasty was performed in 43 hips in 40 patients with protrusion secondary to arthrosis, rheumatoid arthritis or trauma. Depending on the acetabular defect, the acetabuloplasty encompassed reinforcement of the medial wall with bone grafts, vitallium meshes, protrusion rings and cups. The clinical and radiographic results were uniformly good on average 2 years postoperatively. All grafts appeared to be united and incorporated, without evidence of resorption. The only patient suffering from pain had radiographic signs of progressive varus migration of the femoral component.

Acetabulum↗

A survey of finite element analysis in orthopedic biomechanics: the first decade.

The finite element method (FEM), an advanced computer technique of structural stress analysis developed in engineering mechanics, was introduced to orthopedic biomechanics in 1972 to evaluate stresses in human bones. Since then, this method has been applied with increasing frequency for stress analyses of bone and bone-prosthesis structures, fracture fixation devices and various kinds of tissues other than bone. The aims of these investigations were to assess relationship between load carrying functions and morphology of the tissues, and to optimize designs and fixation techniques of implants. Although the amounts of significant findings and useful concepts generated by the FEM during the first decade of its application in this field were limited, many publications have served to illustrate its capabilities and limitations. The method is now well established as a tool for basic research and for design analysis in orthopedic biomechanics, and the number of publications in which it is used is increasing rapidly. In the meantime, following developments in engineering mechanics, the capabilities of the method are augmented which, together with an increasing sophistication of computers, guarantees exciting possibilities for the future. However, the biological structures and the clinical problems concerned are complex. Scientific progress in this area requires a sound understanding of engineering mechanics on the one hand, and a profound appreciation of the complex reality on the other. These features were not always apparent in the FEM work reported during the first ten years. In the following survey, the developments of FEM applications in orthopedic biomechanics during the first decade are discussed. Special problem areas are indicated and future trends anticipated.

Biomechanical Phenomena↗

On the modelling of long bones in structural analyses.

Results of experimental strain gauge and theoretical stress analysis methods are used to investigate the mechanical behavior of the human femur as a structural element under loading. It is shown that when the cortical bone material is assumed to demonstrate linear elastic, homogeneous and transversely isotropic behavior excellent agreement between experimental results and theoretical predictions is obtained. It also follows that the bone shaft can, by reasonable approximation, be represented by an axisymmetric model.

Biomechanical Phenomena↗

The biomechanics of Wolff's law: recent advances.

"Wolff's law" is widely known in orthopaedics. For example, it is often said that load bearing devices, such as joint replacement prostheses or external fixators, cause bone to adapt according to Wolff's law. In this article, the scientific basis for Wolff's law is described in the light of recently developed biomechanical theories of bone behaviour.

Biomechanical Phenomena↗

ESB Research Award 1992. The mechanism of bone remodeling and resorption around press-fitted THA stems.

A major problem threatening the long-term integrity of total hip replacement is the loss of proximal bone often found around noncemented stems in the long term. It is generally accepted that 'stress shielding' is the cause for this problem: after implantation of the prosthesis the surrounding bone is partially 'shielding' from load carrying and starts to resorb. One of the proposed answers to this problem is the application of press-fitted stems. These smooth-surfaced implants are thought to provoke higher proximal bone loading, and, hence, less stress shielding than bonded implants, because they are wedged into the femur every time when loaded. However, in a two-year experiment in dogs, similar amounts of resorption of the proximal cortex were found around press-fitted and bonded implants. The question arises how similar resorption patterns can develop under completely different stress conditions, and whether this phenomenon can be explained by adaptive bone remodeling theories based on Wolff's law. In the present study an answer was sought for this question. An advanced iterative computer simulation model was used to analyze the remodeling process in the animal experiment. Three-dimensional finite element models were constructed from the animal experimental configuration, in which smooth, press-fitted stems were applied unilaterally in the canine. The FE model was integrated with iterative remodeling procedures, validated in earlier studies. In the model an appropriate non-linear representation of the loose bone-implant interface was realized, also capable of simulating the proximal interface gap that was found around the uncoated implants. The simulation models predicted similar amounts of proximal bone loss and distal bone densification as found in the animal model. Hence, the cortical bone loss could indeed be predicted by the strain-adaptive bone remodeling theory. By unraveling the simulation process, the question stated above could be answered. Densification of the distal bone bed during the initial remodeling process was found to cause reduced axial stem displacement (elastic subsidence), decreasing the wedging effect of the stem and, hence, decreasing the loading of the proximal bone, resulting in proximal bone loss. Hence, whereas in the case of bonded stems the proximal resorption process develops monotonously to a new equilibrium, the process around smooth, press-fitted stems develops nonmonotonously. This is due primarily to the unbonded interface conditions and the development of a proximal fibrous membrane. The remodeling process then gradually causes the stem to be jammed in the distal diaphyses (proximal 'stress bypass').

Alloys↗

Mechanical and textural properties of pelvic trabecular bone.

So far, virtually nothing is known about the mechanical properties of pelvic trabecular bone. In this study, several techniques have been used to establish some insight in these properties. Dual-energy quantitative computer tomography (DEQCT) was used to look at the distribution of bone densities throughout the pelvic bone and nondestructive mechanical testing was used to obtain Young's moduli and Poisson's ratios in three orthogonal directions for cubic specimens of pelvic trabecular bone. The same specimens were then used for stereological measurements to obtain volume fractions and the spatial orientations of the mean intercept lengths. The combined data on the mechanical tests and the stereological measurements made it possible to calculate Young's moduli and Poisson's ratios for the specimens' principal material axes. DEQCT showed that bone densities within a pelvic bone are significantly higher in the superior part of the acetabulum, extending to the sacroiliac joint area and, secondly, in the area of the pubic symphysis. Volume fractions found for the specimens did not exceed 20%. This may be considered rather low when compared to values reported in the literature for trabecular bone of femoral or tibial origin, but the values do lie in the same range as vertebral trabecular bone. With the volume fraction as its primary predictor, values of Young's moduli were also low. For most specimens these values were not higher than 100 MPa, with an occasional peak of 250 MPa. Looking at the ratio of the highest and lowest Young's modulus or at the components of the fabric tensor, it can be concluded that pelvic trabecular bone is not highly anisotropic. On an average, Poisson's ratio was found to be closer to 0.2 rather than 0.3, which is in accordance with other studies on Poisson's ratio of trabecular bone.

Acetabulum↗

The anisotropic Hooke's law for cancellous bone and wood.

A method of data analysis for a set of elastic constant measurements is applied to data bases for wood and cancellous bone. For these materials the identification of the type of elastic symmetry is complicated by the variable composition of the material. The data analysis method permits the identification of the type of elastic symmetry to be accomplished independent of the examination of the variable composition. This method of analysis may be applied to any set of elastic constant measurements, but is illustrated here by application to hardwoods and softwoods, and to an extraordinary data base of cancellous bone elastic constants. The solid volume fraction or bulk density is the compositional variable for the elastic constants of these natural materials. The final results are the solid volume fraction dependent orthotropic Hooke's law for cancellous bone and a bulk density dependent one for hardwoods and softwoods.