Clinical experience with Nikkiso centrifugal pumps for extracorporeal circulation.

A comparative study of a newly developed impeller-type centrifugal pump, Nikkiso HMS-15, was made to assess the effects on hemolysis, platelet function, and renal function for extracorporeal circulation (ECC) during open heart surgery. The Bio-pump (cone-type, Medtronic) and the roller pump were used as controls. The increase of serum hemoglobin level in the Nikkiso pump was significantly lower than that in the other pumps. The decrease of platelet counts was recognized after the initiation of ECC in the three pumps whereas the levels of platelet factor 4 and beta-thromboglobulin in the Nikkiso pump group increased by far less than in the other two groups. Moreover, renal function was better maintained in the Nikkiso pump group; in particular, a significantly higher urine output was recorded during ECC and for 1 h after the termination of ECC. The results of our clinical studies suggest that the Nikkiso centrifugal pump is suitable for ECC during open heart surgery.

Extracorporeal Circulation↗

[Red tide].

Explore the source record for details and available documents.

Dinoflagellida↗

Experimental evaluation of a newly developed ultrathin silicone layer coated hollow fiber oxygenator.

The authors developed a new membrane oxygenator that consists of microporous polypropylene hollow fibers coated with a 0.2 micron ultrathin silicone layer. Five venoarterial bypasses were conducted on mongrel dogs for 24 hr using these new oxygenators. The blood flow rate was maintained at 750 ml/min, and the V/Q ratio was maintained at 1:1. As a control, three venoarterial bypasses were conducted under the same conditions using an oxygenator with the same design but without the silicone coating. Eight to 16 hr after the initiation of bypass, severe plasma leakage occurred in all control experiments, so the bypasses were terminated. However, plasma leakage did not occur throughout the 24 hr of any of the experiments using the new oxygenator. The O2 transfer rate of the new oxygenators after 24 hr of perfusion was 59.7 +/- 6.6 ml/min/m2, and the plasma free hemoglobin level 8 hr after the initiation of bypass was 41.4 +/- 40.2 mg/dl, compared with 145.3 +/- 189.6 mg/dl in the control group. Scanning electron microscopic examination of the silicone coated fibers after 24 hr of bypass revealed a few scattered platelet adherents and no damage to the silicone coated surface. These results suggest that this new oxygenator has satisfactory gas transfer and good durability.

Animals↗