Search PubMed⌕ Search

Biomedical subjects

R Hipp

Publications and source records attributed to R Hipp.

At least 19 recordsLinked to original sources

Coagulation effects of a recently developed hydroxyethyl starch (HES 130/0.4) compared to hydroxyethyl starches with higher molecular weight.

BACKGROUND: Hydroxyethyl starches (HES) are known to interfere with blood coagulation according to molecular weight, the degree of substitution and the C2/C6 ratio. A recently developed low molecular hydroxyethyl starch (HES 130/0.4) was designed to reduce the blood compromising potency. METHODS: In this study, effects of a 30% in vitro haemodilution with the new HES preparation (HES 130/0.4) in comparison to HES 200/0.5, HES 450/0.7 and sodium chloride solution were investigated using intrinsic and extrinsic activated thrombelastography (TEG) and plasmatic coagulation tests. RESULTS: Whereas plasmatic tests revealed no prolongation of coagulation by HES in comparison to sodium chloride, the TEG variables clotting time, clot formation time and maximal clot firmness showed a significant (P<0.05) inhibition by all the HES preparations. The inhibition was most pronounced in HES 450 (P<0.05 vs HES 130) while HES 130 did not show a statistically significant difference in extrinsic activated maximal clot firmness when compared to sodium chloride. CONCLUSION: These in vitro results demonstrate that hydroxythyl starches especially compromise clot polymerisation. The new preparation HES 130/0.4 seems to inhibit platelet function to a lesser extent than hydroxyethyl starch preparations with a higher molecular weight and degree of substitution.

Blood Coagulation↗

Intravenous clonidine decreases minimum end-tidal isoflurane for induction of electroencephalographic burst suppression.

The aim of this study was to determine the individual end-tidal isoflurane (ET ISO) threshold concentration for the induction of electroencephalographic (EEG) burst suppression with and without intravenous (I.V.) clonidine and to evaluate the EEG and cardiovascular response to skin incision during isoflurane/N2O anesthesia. Thirty-nine patients (ASA physical status I or II, 20-68 yr of age) undergoing orthopedic surgery were randomly assigned to receive I.V. saline (n = 20) or I.V. clonidine (3 microg/kg, n = 19). After detection of isoflurane-induced burst suppression, ET ISO was decreased in 0.1% ET steps until burst suppression diminished. Median minimum ET ISO for induction of burst suppression was 1.4% in the saline group and 0.9% in the clonidine group (P < 0.05). Before skin incision, EEG alpha 2 activity was significantly higher in the clonidine group compared with saline group. Fourteen patients (70%) in the saline group and 12 patients (63%) in the clonidine group showed a cardiovascular response to skin incision. After skin incision, EEG alpha 2 power was significantly decreased in both groups. A significant increase of delta activity was only found in the saline group. We conclude that the known minimum alveolar anesthetic concentration reduction of clonidine seems to be due to a direct cerebral action.

Adjuvants, Anesthesia↗

[Comparison of the effect of desflurane and isoflurane on neuromuscular blockage with vecuronium on geriatric patients].

Volatile anaesthetics have long been known to intensify the effect of muscle relaxants. In this study we investigated the effects of desflurane and isoflurane on the neuromuscular blockade of vecuronium in geriatric patients. Fifty-two patients requiring elective surgery, aged > or = 65 years, with ASA status II - III were randomly assigned to receive general anaesthesia using desflurane (Des, n = 26) or isoflurane (Iso, n = 26). The effects of both inhalation anaesthetics on the neuromuscular blockade of vecuronium were compared by means of the duration of the depression of the first twitch (T1) of a train-of-four stimulation pattern. Succinylcholine 1.5 mg/kg was used to facilitate intubation, vecuronium 0.05 mg/kg was given as the succinylcholine wore off; additional doses of 0.01 mg/kg were given when T1 exceeded 25% of baseline amplitude. There were no significant differences in the patients' biometric data or the duration of anaesthesia. The median duration of action of the first vecuronium dose (0.05 mg/kg) was: Des: 18.3 (9.4-42.9) min and Iso: 15.9 (3.1-46.0) min. The number of repetitive dosages (0.01 mg/kg) was: Des: 5; 0-13 and Iso: 5; 0-14 and their median duration was: Des: 10.2 (3.6-37.6) min and Iso: 8.9 (2.1-43.9) min. There were no differences between the two groups (p > 0.05). These results suggest that augmentation of neuromuscular blockade by older fluorinated anesthetics is also exhibited by desflurane. The magnitude of this effect in geriatric patients is similar to that of isoflurane.

Aged↗

A lower solubility recommends the use of desflurane more than isoflurane, halothane, and enflurane under low-flow conditions.

STUDY OBJECTIVE: To determine whether the lower solubility of desflurane, over that of isoflurane, enflurane, and halothane, favors its use in low-flow anesthesia. DESIGN: Prospective clinical study. SETTING: Technical University of Munich. PATIENTS: 40 elderly (> or = 65 yrs), ASA physical status II and III surgical patients. INTERVENTIONS: All patients were anesthetized and received delivered concentrations (FD) of 4% desflurane, 1.5% isoflurane, 1.8% enflurane, or 0.9% halothane (n = 10 patients for each anesthetic) in a fresh gas inflow of 3 L/min (high-flow), until end-tidal target concentrations (FA) of 2% desflurane, 0.5% isoflurane, 0.6% enflurane, and 0.3% halothane were obtained. After 30 minutes, the inflow was decreased to 1 L/min (low-flow), and the FD and the inspired concentration (FI) were adjusted to maintain the target concentration. MEASUREMENTS AND MAIN RESULTS: The concentrations of the halogenated anesthetics, as well as nitrous oxide, oxygen (O2), and carbon dioxide, were measured in delivered gas at the common gas outlet and at the endotracheal tube connector. Transcutaneous O2 saturation, noninvasive blood pressure, and heart rate were also measured. During the first 30 minutes of high-flow administration, the target concentration was attained sooner with desflurane than with isoflurane, enflurane, or halothane (median levels: 4 min vs. 6 min, 8 min, or 10 min; p < 0.01). After the reduction of inflow to 1 L/min, FD had to be materially increased to maintain F1 and FA for the more soluble anesthetics, but not for desflurane. CONCLUSIONS: At low flows, FD provides a reasonable surrogate of F1 and FA for desflurane, but not for isoflurane, enflurane, or halothane. The rapid and predictable titrability of desflurane favors its safe use in low-flow technique.

Aged↗

[Anesthesia with low fresh gas flow in clinical routine use].

Anaesthesia in low-flow techniques gains increasing interest. The possibility of cost reduction, widespread use of highly developed anaesthesia machines and monitors, and introduction of two new fluorinated inhalational anaesthetics with low solubility in human tissues encourage the use of low-flow anaesthesia techniques. Further advantages are improved climatisation of breathing gas and estimation or even measurement of the important parameter "oxygen consumption". The anaesthesia machines and inhalational anaesthetics currently available allow a safe use of low-flow techniques if safety requirements are complied with (tight circle system, monitoring of: inspired oxygen concentration, minute ventilation, airway pressure, transcutaneous oxygen saturation). Low-flow anaesthesia techniques using a fresh gas flow rate of 1 l/min can be performed with almost every anaesthesia machine. However, the use of multigas monitors, analyzing most parts of the breathing gas, facilitates the use of low-flow techniques. Multigas monitors and anaesthesia machines equipped with intermittent fresh gas delivery are recommended for the use of fresh gas flow rates close to the metabolic rate. Because of its physicochemical properties the new inhalational anaesthetic desflurane offers advantages for the use in low-flow anaesthesia techniques.

Anesthesia, Closed-Circuit↗

[Comparison of the effectiveness of orally administered clorazepate dipotassium and nordiazepam on preoperative anxiety].

Clorazepate dipotassium (Tranxilium) is one of the benzodiazepines which is widely used for oral premedication. After oral administration it is decarboxylated to its active metabolite nordiazepam (desmethyldiazepam). Nordiazepam is also commercially available in the form of drops (Tranxilium N). The aim of the present study was to compare the effect of these drugs on preoperative anxiety. One hundred and eight patients scheduled for orthopaedic surgery (ASA I-II) were studied. Medication was administered at 10 p.m. the evening before surgery (E) and at 7 a.m. on the morning of surgery (M). There were four groups: 1) E no medication; M clorazepate dipotassium; 2) E no medication; M nordiazepam; 3) E clorazepate dipotassium; M clorazepate dipotassium, 4) E clorazepate dipotassium; M nordiazepam. Dosages were: clorazepate dipotassium: body weight < 55 kg: 10 mg; body weight > 55 kg: 20 mg; nordiazepam: 1 gtt/kg; 5 mg = 24 gtt). Anxiety was measured by using the self-evaluating Erlangen anxiety scales, which measure both background and situational anxiety. Background anxiety (EAS-H) was evaluated during the evening before surgery; situational anxiety (EAS-S) was evaluated at the same time and also on the day of surgery before premedication and immediately before surgery. Pulse rate was measured each time the test was administered. There were no differences between the groups in sex, age, weight or the intervals between premedication and anaesthesia induction (p > 0.05). There were no statistically significant differences between the groups with respect to background anxiety. Situational anxiety did not significantly increase or decrease at any of the testing times, nor were there any differences between the groups (p > 0.05). Heart rate did not vary between the groups or with time (p > 0.05). In this group of patients undergoing elective orthopaedic procedures, clorazepate prevented a rise in anxiety in the immediate preoperative period. Since clorazepate is rapidly metabolized to nordiazepam when administered orally it might be predicted that the two drugs have similar properties. This hypothesis is confirmed by the results of the present study. We conclude that orally administered clorazepate dipotassium and nordiazepam have a similar effect on preoperative anxiety.

Administration, Oral↗

[Hypervolemic hemodilution as a means of preventing homologous blood transfusion. A simple alternative to acute normovolemic hemodilution].

PROBLEM: Acute normovolenic hemodilution (ANH) is timeconsuming and complicated, and has only a small effect in reducing the need for homologous blood. A simpler procedure is hypervolemic hemodilution (HHD). In the present prospective, randomized study, HHD is compared with ANH for its blood-saving effect. STUDY DESIGN: Forty-nine patients undergoing total hip replacement were admitted. Group I (ANH): Withdrawal of 15 ml/kg bodyweight autologous blood and isovolemic replacement by hydroxyethyl starch (200/0.5). Group II (HHD): Infusion of 15 ml/kg bodyweight hydroxyethyl starch (200/0.5). RESULTS: No significant differences were found between the groups in terms of Hb, hematocrit and coagulation. The blood loss (intra-operative+drainage losses) was comparable in the two groups at 1274 +/- 310 ml (HHD) and 130 +/- 335 ml (ANH). During the period under investigation, 66% of the patients in the HHD group and 57% in the ANH group required no homologous blood. CONCLUSION: HHD is just as effective as ANH for reducing homologous blood requirements, and is much simpler to apply.

Blood Loss, Surgical↗

[Strategies for minimizing homologous blood transfusion in elective interventions].

The risks associated with homologous blood transfusion necessitates the development of strategies for reducing the need for it. The most effective method is certainly preoperative donation of autologous blood, which leads to an increase in the absolute numbers of erythr789789 by the time surgery is performed. Depending on the type of preparation and storage, erythrocytes may be viable for between 49 days (liquid storage) and many years (deep frozen). By employing preoperative plasmapheresis, high-quality autologous fresh frozen plasma can be made available for use during surgery. Donation of autologous blood and plasmapheresis are preoperative measures that need to be organized. Another possibility is the use of a cell separator to recycle blood lost during surgery, and may be applied intra-operatively (aspiration from the surgical wound) or postoperative (drainage). Hemodilution has but little effect in reducing homologous blood requirements. Instead of the technically complex and time-consuming acute normovolemic hemodilution (ANH), the simpler hypervolemic alternative version (HHD) should be employed. Applying all the measures described above, an appreciable reduction in the need for homologous blood can be achieved. A prerequisite, however, is close cooperation between the surgeon an anaesthesiologist.

Blood Transfusion, Autologous↗

[Blood transfusion in surgical gynecology. Strategies for preventing homologous blood transfusion].

A statistical evaluation of homologous blood transfusions is imperative in any gynecological surgical department, to be able to define the transfusion-associated risk of the individual interventions. On the basis of our own statistical data and reports in the literature, strategies for limiting the use of homologous blood are discussed. So far, experience with autologous blood transfusion in surgical gynecology is limited, and clinical studies are needed to better define its role. In special cases, the use of erythropoietin and gonadotropin-releasing hormone (GnRH) analogues extends the possibilities for reducing homologous blood transfusion.

Adult↗

[Drug administration via the endobronchial route. Possibilities of drug administration in emergency medicine].

For cardiopulmonary resuscitation, the endobronchial route represents a good means of administering drugs with a systemic effect, such as adrenaline and atropine, even without a venous line. Via this route, however, higher doses are needed (2.5 times as much as those normally given intravenously). In order to produce a larger surface area within the bronchio-alveolar space and thus speed up absorption, the drugs are diluted in 5-10 ml solvent (isotonic saline solution or distilled water). For endobronchial administration of a drug, various techniques are employed, for example, simply injecting it into the upper end of the (endotracheal) tube, puncture of the tube the use of an application probe introduced into the endobronchial tube, aspiration or venacaval catheter, or the EDGAR tube with an injection needle incorporated within the tube wall. After injection, the diluted medication is distributed into the tiny branches of the bronchial tree by repeated hyperventilation. Despite the need for an adequate alternative to the venous route in the field of cardiopulmonary resuscitation, we still have very few reliable facts about the endobronchial application technique.

Administration, Inhalation↗

[Electroencephalographic demonstration of central nervous system effects of different premedication regimens].

INTRODUCTION: For many years, the main goal of premedication was prevention of the dangerous side effects sometimes encountered in anesthetics with anticholinergics, antiemetic antihistaminics, and opioids. Because the rules were always preoperative fasting, premedication was administered i.m. Thus, the onset of action was within 15-30 min from administration. In recent years, with the introduction of newer anesthetics with fewer side effects, anxiolysis became the main aim in premedication. Moreover, the oral route became popular since it obviously did not increase the acidity or volume of the gastric content. However, the uptake and thus onset of action of orally administered drugs may take longer and can differ considerably between individual patients. Therefore, the optimum interval between administration and induction of anesthesia remains controversial. The present study was carried out to examine the time course of drug action and the effects of different premedication regimens on the electroencephalogram (EEG). PATIENTS AND METHODS: After obtaining informed consent, in 38 unselected adult patients (ASA I and II, < 65 years) scheduled for elective surgery, the EEG was recorded continuously before and after premedication. The patients were randomly assigned to four groups: M: midazolam, 0.2 mg/kg BW orally; N: nordazepam, 0.2 mg/kg BW orally; AP: atropine, 0.5 mg, plus promethazine, 50 mg i.m.; APP: atropine, 0.5 mg, plus promethazine, 50 mg, plus pethidine, 0.7 mg/kg BW i.m. The EEG was recorded for a reference period of 10 min before and a study period of 30 min after premedication. Automated EEG processing was performed with CATEEM (computer-aided topographical electroencephalometry). Surface electrodes were placed according to the 10-20 system. Date were collected via an amplifier (resistance 10 M omega) and a digitalization unit (filter 0.2-35 Hz, sampling rate 512 Hz, 12 bit A/D convertor). The original EEG signals were used in an interpolation algorythm to produce an additional 82 virtual recording points, allowing for high topographical resolution. After spectral analysis (fast Fourier transformation), the different frequency ranges of the EEG power spectrum are displayed in different colors. The screen displays the on-line map with color-based topographical power distribution. In order to achieve a pharmacodynamic time profile, the study period was subdivided into three periods of 10 min each. For clinical evaluation of vigilance, a 6-grade scoring system was used 1 = awake, 6 = not arousable). RESULTS: All data are presented with respect to reference period. The power density of each frequency range for each electrode is integrated over the selected period and mean values are shown. Changes in power density with time are expressed as percentage change from reference period. Biometrical data showed no significant differences between groups. The median vigilance score 30 min after premedication (end of study period) was 4 in groups M, AP, and APP, and 3 in group N. In both benzodiazepine groups, a distinct increase in power density was found in the beta-bands, while in groups AP and APP the increase was most pronounced in the delta and theta bands. In group M, there was a linear increase in beta 1 power up to 310%, while in the beta 2 range there was a 170% maximum within the second period of 10 min. In group N, there was a similar course with a lower increase in beta 1 (220%) and beta 2 (130%). Increases in both beta-bands were most pronounced with frontal electrodes. While group M showed an increase in delta power (150%), together with moderate suppression in alpha (alpha 1 50%, alpha 2 40%), nordazepam caused only a slight increase in delta (124%) and a distinct increase in alpha 2 to 150%, predominantly in the frontal areas. Group APP showed a linear increase in both delta up to 210% and theta power to 190%. (ABSTRACT TRUNCATED)

Adult↗

[Anesthesia with the closed PhysioFlex system in comparison with conventional anesthesia procedures].

So far the anaesthetic technique of the closed circuit system in clinical routine could not be used adequately, because suitable mixtures of respiration gas components were not available and the maintenance of a sufficient gas volume in the anaesthetic circle system was not possible with the standard anaesthesia machines. The anaesthesia machine PhysioFlex was especially constructed to deliver anaesthetics in a closed circuit system. In this anaesthesia machine the concentrations of the respiratory gases and the gas volume in the circle system are automatically controlled by a feedback mechanism. We compared the closed circuit system (CC group), with a high-flow system (HF group) and a low-flow system (LF group)--each system on 10 patients. It was noted that the respiratory gas concentrations were adjustable and held constant to a greater degree precise in the circuit system. After the induction the desired inspiratory oxygen-concentration was reached within 5 minutes, the expiratory isoflurane-concentration within 10 minutes in the CC group and was maintained reliable. The consumption of liquid isoflurane was 12.9 ml/h in the HF group, 7.5 ml/h in the LF group and 5.3 ml/h in the CC group. The anaesthetic management was possible without any problems in all three groups.

Adult↗