Search PubMed⌕ Search

Biomedical subjects

R Hetzer

Publications and source records attributed to R Hetzer.

At least 163 records · Page 9Linked to original sources

Complicated chronic pancreatitis causing mycotic aortic aneurysm: in situ replacement with a cryopreserved aortic allograft.

Mycotic aortic aneurysm, which resulted from infected pancreatic pseudocysts with retroperitoneal abscess, developed in a patient with chronic pancreatitis. The aorta was approached through median laparotomy. Necrotic material was debrided from the pancreatic pseudocysts, and the mycotic aneurysm was resected. The aorta was replaced in situ with a cryopreserved aortic allograft. This report discusses the rare complication of pancreatic pseudocysts, which affect the infrarenal abdominal aorta and cause a large mycotic aneurysm. This case suggests that the use of cryopreserved allografts is promising for in situ reconstruction, even in a grossly infected field.

Aneurysm, Infected↗

Elimination of recombinant hirudin by modified ultrafiltration during simulated cardiopulmonary bypass: assessment of different filter systems.

UNLABELLED: Recombinant hirudin (r-hirudin) is being used increasingly in patients with heparin-induced thrombocytopenia type II. Renal failure has been demonstrated to prolong the half-life of r-hirudin and to cause bleeding in patients who have undergone cardiopulmonary bypass (CPB). We assessed the ability of different filter systems for modified ultrafiltration to eliminate r-hirudin in vitro using simulated CPB. r-Hirudin concentration was measured (chromogenic laboratory standard plus ecarin clotting time) before and after filtration, and its elimination was calculated using both controlled system flow and arterial inflow (separate pump). Four hemofilters (Renoflow II, Baxter; Arylane H4, Cobe; Ultraflux AV 600, Fresenius; and BCS 110 Plus, Iostra) and two plasmapheresis filter systems (ASAHI Plasmaflow OP, Diamed; and PF 2000 N, Gambro) were assessed (5 filters of each brand = 30 filters) in a closed in vitro CPB system applying conditions usually occurring during CPB. Ten plasmapheresis filters showed a greater ability than 20 hemofilters to eliminate r-hirudin (60%-70% vs 15%-42%) within the shortest time (80 vs 180 s). Among the four hemofilter systems, the Arylane H4 filter provided the most effective (42%) r-hirudin elimination. Elimination of r-hirudin was markedly improved using plasmapheresis systems, compared with hemofilter systems. Our findings may be relevant to patients with impaired renal function, who have been administered r-hirudin during CPB. IMPLICATIONS: Modified ultrafiltration may enhance the elimination of recombinant-hirudin, although plasmapheresis systems provide the most rapid and complete elimination of recombinant-hirudin during simulated cardiopulmonary bypass. The decision to use a specific system will ultimately depend on the prevailing clinical situation and overall health of the patient.

Adult↗

Modulation of contractions to ergonovine and methylergonovine by nitric oxide and thromboxane A2 in the human coronary artery.

This study explored the modulatory effects of nitric oxide and thromboxane A2 on contractions to ergonovine and methylergonovine in human coronary arteries. To elucidate the different role of nitric oxide synthase in the response to the ergot alkaloids, the serotonin (5-HT) receptors involved in nitric oxide synthase in the response to the ergot alkaloids, the 5-HT receptors involved in nitric oxide release and the contraction of the vascular smooth muscle were characterized with more selective 5-HT-receptor agonists and antagonists. Rings of human coronary arteries from explanted hearts were suspended in organ chambers for isometric tension recording. After testing for contractile (potassium chloride, 60 mM) and endothelial function (substance P, 10(-8) M), respectively, they were exposed to ergot alkaloids or other agonists in the absence or presence of U 46619 (10(-9) M), or nitro-L-arginine (10(-4) M), or both. Ergonovine and methylergonovine were comparable, weak vasoconstrictors in untreated preparations. Contractions to ergonovine were augmented by U 46619, but not by nitro-L-arginine. Contractions to methylergonovine were augmented only by combining U 46619 and nitro-L-arginine. Serotonin and methylergonovine, but not ergonovine, elicited endothelium-dependent, nitric oxide-mediated relaxations. Nonselective 5-HT(1B/1D)-receptor stimulation caused both contractions and relaxations; selective 5-HT1B stimulation caused relaxations only. In the human coronary artery, contractions to ergonovine are not dependent on NO release but are synergistically augmented by thromboxane. Methylergonovine causes similar effects on the vascular smooth muscle, but contractions are inhibited by the release of NO from the endothelium. The 5-HT receptor on the endothelium appears to be different from the receptor on the vascular smooth muscle, which mediates the contractile response to the ergot alkaloids.

Adult↗

Reproducibility of serial intravascular ultrasound measurements in patients with angiographically silent coronary artery disease after heart transplantation.

BACKGROUND: Intracoronary ultrasound (ICUS) imaging is the most sensitive method for the early detection and serial evaluation of vasculopathy of transplants. Both lack of agreement between observers and lack of agreement between serial, independent pullback procedures (repeatability), which can result in a variable intraluminal catheter position may limit the reproducibility of ICUS measurements. OBJECTIVE: To evaluate the reproducibility of serial measurements of standard linear and area cross-sectional coronary dimensions in patients with non-obstructive transplant vasculopathy. METHODS: We performed ICUS imaging of patients without angiographic evidence of obstructive epicardial coronary artery disease after heart transplantation. A 30 MHz phased-array transducer was used. Two independent pullbacks of the left anterior descending coronary artery were performed and recorded on CD-ROM for off-line quantitative analysis of the most severely diseased site. Agreement of observers and repeatability of serial measurements were calculated by the use of linear regression analysis and Bland-Altman plots. RESULTS: Regarding agreement of observers, correlation coefficients for intra-observer agreement ranged from r = 0.98 to r = 0.99; those for interobserver agreement ranged from r = 0.87 to r = 0.98. Serial measurements of the identical coronary artery cross-section within independent catheter pullback procedures were possible for 104 of 112 target lesions (92.90/%). Correlation coefficients ranged from r = 0.91 to r = 0.97 (for lumen diameter r = 0.91, for lumen area r = 0.93, for vessel diameter r = 0.91, for vessel area r = 0.97, for thickness of plaque r = 0.96 and for area of plaque 0.94). The mean difference of measurements was around zero for all parameters with SD from 0.13 to 0.4 mm for linear parameters and from 1.53 to 1.82 mm2 for area parameters. CONCLUSION: Serial intravascular ultrasound measurements are highly reproducible without any evidence of systematic error and a SD of differences of measurements beyond the maximal spatial resolution of currently available intravascular ultrasound catheters.

Coronary Angiography↗

Arterial switch procedure for D-transposition of the great arteries: quantitative midterm evaluation of hemodynamic changes with cine MR imaging and phase-shift velocity mapping-initial experience.

PURPOSE: To evaluate cine magnetic resonance (MR) imaging and phase-shift velocity mapping for assessment of the hemodynamic relevance of stenotic segments or specific hemodynamic changes in the great vessels after an arterial switch procedure for correction of D-transposition of the great arteries. MATERIALS AND METHODS: Twenty consecutive patients (age range, 2-17 years) with an acoustic window that was insufficient for Doppler transthoracic echocardiography were included in the study. Flow and diameter measurements of the pulmonary arterial trunk and its primary branches were performed with phase-shift velocity mapping and cine MR imaging. RESULTS: There were good correlations between pressure gradients in the pulmonary arteries estimated with MR imaging and those measured with Doppler echocardiography (r = 0.83, n = 15) and cardiac catheterization (r = 0.90, n = 13). Cine MR imaging revealed that the diameters of the right and left pulmonary arteries decreased with the expansion of the aorta during systole, which increased the peak velocity. This temporary stenosis was more severe in the right than in the left pulmonary artery and was accompanied by a significantly (P <.05) lower volume flow in the right artery. CONCLUSION: The anatomic situation after arterial switch repair tended to produce temporary stenoses in the primary pulmonary arterial branches, with significant changes in hemodynamics. These changes may affect the long-term outcome and go undetected with other imaging modalities.

Adolescent↗

Aortic rupture and concomitant transection of the left bronchus after blunt chest trauma.

We report a patient with traumatic aortic rupture and preoperatively unrecognized complete disruption of the bronchus for the left lower lobe. Preoperative state was complicated by inadequate oxygenation due to total atelectasis of the unventilated collapsed left lower lobe with consequent significant shunting of the unoxygenated blood. The patient had no massive pneumothorax because the intact peribronchial tissue and pleura covered the injured place, preventing important air leakage. The suspicion of possible concomitant tracheobronchial injury and early diagnostic bronchoscopy are important in patients with aortic rupture after blunt chest trauma.

Adult↗

Protein S-100beta in brain and serum after deep hypothermic circulatory arrest in rabbits: relationship to perivascular astrocytic swelling.

The aim of this study was to evaluate the relationship between the kinetic patterns of the protein S-100beta, an astroglial cell marker, and its immunohistochemical expression in the brain in rabbits that underwent cardiopulmonary bypass with deep hypothermic circulatory arrest. Fourteen New Zealand rabbits (weight, 3.1+/-0.25 kg) were anaesthetised, intubated and mechanically ventilated. Four animals were not connected to the cardiopulmonary bypass and served as controls. Ten animals were perfused according to a uniform protocol. After systemic cooling, deep hypothermic circulatory arrest was induced for 60 minutes. After reperfusion and rewarming, the animals were weaned from bypass and sacrificed. In the brain, astrocyte reactivity for S-100beta was evaluated immunocytochemically (DPC Immustain) and the serum concentrations of S-100beta were analysed using a commercially available immunoluminometric kit (Byk-Sangtec, Dietzenbach, Germany). In all experimental animals a significant increase of the serum concentration of the protein S-100beta was found immediately after reperfusion and the termination of cardiopulmonary bypass. In comparison with the control animals, increased staining of S-100beta was found in the astroglial cells and swollen astrocytic end-feet in the perivascular regions. There were fewer signs of neuronal cell injury of neurones in the hippocampus structure. In conclusion, astrocytic activation and S-100beta overexpression seems to precede the neurodegeneration following deep hypothermic circulatory arrest. The marked perivascular cell swelling may support the assumption of reperfusion injury of the astroglial cell complex that forms the blood-brain barrier, which may be indicative of the source of the released S-100beta into the blood stream.

Animals↗

[Use of patient-related contrast media protocols in cardiovascular computerized tomography].

PURPOSE: To determine the temporal variability of the time to maximum aortic density after peripheral venous contrast injection in cardiovascular CT studies and to calculate potential contrast agent savings of selecting scan delay from test bolus kinetics. METHODS: A peripheral contrast bolus was administered intravenously in 138 consecutive patients to determine the time to maximum density in a left ventricular or aortic region of interest by electron beam CT. 20 EKG-triggered scans were acquired within 70 heartbeats. The deviation of the time to maximum density from a standard, fixed scan delay was determined. RESULTS: Mean time to maximum density was 22 s, and the average deviation from that mean was 5 s. At an injection rate of 4 cc/s, this deviation implies that determining the individual scan delay from a test bolus injection may potentially save 20 cc contrast per patient. This amount of contrast agent, in turn, is required for the test bolus. CONCLUSION: Deriving the individual scan delay from test bolus kinetics may improve image contrast in cardiovascular CT studies without additional contrast expense.

Adult↗

Intramyocardial electrogram recordings (IMEG) for diagnosis of cellular and humoral mediated cardiac allograft rejection.

OBJECTIVE: The purpose of this study was to prove the reliability of intramyocardial electrogram (IMEG) recordings for diagnosis and treatment monitoring of (1) cellular and (2) humoral mediated allograft rejection after heart transplantation. MATERIAL AND METHODS: Fifteen beagle dogs underwent heterotopic neck-heart transplantation. Eight of them were previously sensitized through several skin transplantations. IMEG recordings were performed daily. Donor-specific antibodies (IgG, IgM) were determinated in serum daily. Transmyocardial biopsies were performed every two days. RESULTS: In the sensitized group (group I) accelerated rejection occurred under triple drug immunosuppression with cyclosporine A, azathioprine, and cortisone on the fifth postoperative day (range: 4th-5th). All episodes were detected through IMEG diagnosis. In each case rejection could be treated successfully. In the cellular mediated group (group II), the average sensitivity for rejection diagnosis of a single lead was 24% for the unipolar and 42% for the bipolar leads. When the voltages of different leads were summed up the sensitivity rose to 36% (3 unipolar), 81% (3 bipolar) and 100% (all leads). During rejection therapy the IMEG recovered within 24-48 hours. CONCLUSION: The IMEG detects cellular and humoral mediated rejection early and with high reliability. The rejection-related changes of grade 2/3a rejection in IMEG seem to follow a Ofocal patternO similar to the histology. Therefore the recording of several, preferably bipolar, electrode configurations appears to enhance diagnostic reliability.

Animals↗

Recombinant hirudin as an alternative for anticoagulation during cardiopulmonary bypass in patients with heparin-induced thrombocytopenia type II: a 1-year experience in 57 patients.

OBJECTIVE: To explore the possible use of recombinant hirudin (r-hirudin) as an alternative to heparin for anticoagulation during cardiovascular surgery. DESIGN: Retrospective analysis. SETTING: Two university hospitals. PARTICIPANTS: Fifty-seven patients with heparin-induced thrombocytopenia type II (HIT II) in whom r-hirudin was used during cardiovascular surgery with cardiopulmonary bypass (CPB). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The r-hirudin concentration was monitored on-line, at the point of the patient's care using the ecarin clotting time and maintained in the range of 3 to 4 microg/mL. The r-hirudin elimination at the conclusion of CPB was augmented through modified zero-balanced ultrafiltration and forced diuresis. The duration of CPB was 63 to 246 minutes. The r-hirudin requirement per minute of CPB was 0.016 to 0.035 microg/kg/min, and the 24-hour blood drainage was 50 to 2,200 mL. Of the 57 patients, 54 fully recovered, including 9 patients who did not require any allogenic products. Four patients, all with impaired renal function, showed prolonged r-hirudin elimination and excessive bleeding and required surgical reexploration. Three patients died as a result of complications unrelated to the perioperative management. CONCLUSION: This study provides evidence that r-hirudin can be used safely and effectively for routine anticoagulation during CPB in patients diagnosed with HIT II. Almost 95% of the patients in whom it was used were discharged uneventfully. Patients with perioperative renal failure, however, showed increased bleeding.

Adult↗

Hirudin monitoring using the TAS ecarin clotting time in patients with heparin-induced thrombocytopenia type II.

OBJECTIVE: To assess the reliability of the TAS/ecarin clotting time (ECT) for on-line monitoring of r-hirudin in cardiovascular surgery with and without cardiopulmonary bypass (CPB). DESIGN: Samples were spiked with r-hirudin (0 to 5 microg/mL) and calibration curves constructed. Reproducibility was evaluated by measurement of the sample five times at each concentration. The influence of variations in hematocrit, plasma factors, and platelet count on the test results was examined. Samples were obtained from patients during cardiovascular surgery with CPB (n = 8), without CPB (n = 3), and from volunteers (n = 5) and compared with the laboratory reference tests. All tests were performed in duplicate. SETTING: Deutsches Herzzentrum Berlin. PARTICIPANTS: Five healthy volunteers and 11 patients undergoing cardiovascular surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The TAS/ECT showed linearity and reliability to an r-hirudin concentration of 5 microg/mL and was not influenced (p < 0.005) by the varying conditions of the in vitro setup. The correlation to the laboratory method was 0.74 for the CPB group and 0.87 for the non-CPB group. CONCLUSIONS: The TAS/ECT is a reliable assay for monitoring r-hirudin at the point of care. With this information, the use of r-hirudin during surgery or angioplasty should become more effective and safer.

Adult↗

[Advances and perspectives in mechanical heart assist].

Mechanical circulatory support devices were first developed to permanently replace the failing heart. Today, however, the majority of these devices are used as a mechanical bridge in patients awaiting heart transplantation. With this indication, important information on using mechanical assist devices has been assembled. We present our experience, which has been gained since 1987 in the area of patient selection, post-implant patient care and device maintenance. More than 450 patients have since been implanted with assist devices at our institution. Mechanical circulatory support may not only lead to recovery from secondary organ failure, but also to myocardial remodeling and recovery of the heart function in some patients. Additionally we report our experience with a newly developed implantable axial flow pump and discuss the possibility and costs of permanent support in some patients.

Adult↗

Annular stabilization in mitral repair without a prosthetic ring.

BACKGROUND AND AIM OF THE STUDY: Annular stability is not guaranteed after mitral repair without a prosthetic ring. We introduce a newly developed plication technique and detail its stabilizing effect on the mitral annulus after Gerbode plasty. METHODS: Patients suffered degenerative mitral valve prolapse with chordal rupture restricted to the middle scallop of the posterior leaflet. Between 1986 and 1997, 102 patients underwent Gerbode plasty with or without annular reinforcement with a pericardial strip or modified Paneth plasty (group C). The mean (+/- SD) follow up was 70.4 +/- 41.1 months. Since 1996, 32 patients have undergone a newly developed annuloplasty technique (group N), where a pericardial strip was tightly anchored to the bilateral trigones and posterior annulus, which was folded by Gerbode plasty. With the final anchoring suture the intention was to prevent plication breakdown of this portion. Mean follow up for this group was 17.6 +/- 7.1 months. Progression of mitral regurgitation after surgery in both groups was studied. RESULTS: In group C, postoperative progression of mitral valve regurgitation occurred in 41.1% of patients (5.9% to grade 1, 17.6% to grade 2, 17.6% to grade 3). Among these patients, reoperation was due to plication breakdown of the Gerbode plasty in six cases (5.9%), and to either chordal rupture or annular dilatation in 10 cases each (9.8%). In contrast, no reoperation due to recurrent severe mitral regurgitation was needed in group N. Progression of mitral regurgitation after surgery was seen in six patients (two to grade 1; four to grade 2). CONCLUSION: The newly developed annuloplasty technique may be useful in stabilizing the mitral annulus after Gerbode plasty.

Adolescent↗

Acute changes in functional and metabolic parameters following transmyocardial laser revascularization: an experimental study.

Today there is no doubt that angina in patients with diffuse end-stage coronary artery disease can be treated effectively by transmyocardial laser revascularization (TMLR). But until now, the underlying mechanism of TMLR is a matter of debate. The aim of this study was to investigate the immediate changes in functional and metabolic parameters after the creation of TMLR channels. In 12 pigs the local myocardial function (pressure-wall thickness-loops), tissue oxygen partial pressure (PO(2)), and the left ventricular intramyocardial wall pressure (IMP) was investigated simultaneously. The left ventricle was divided into 3 areas. Ischemia was induced in regions 1 and 2 by interrupting the coronary blood flow via the left anterior descending artery for 30 seconds. Region 3 served as non-ischemic control region. Thirty minutes after creation of 15-20 TMR channels in region 1, we repeated the coronary occlusion in regions 1 and 2 followed by measurement of all parameters in the 3 regions. The TMLR-treated region 1 showed a better contractility, a higher tissue PO2 and a higher intramyocardial wall pressure during the post-TMLR coronary occlusion in 8 out of 12 pigs when compared with the pre-TMLR occlusion (p<0.05), whereas the untreated region 2 continued to show severe disturbances in myocardial contractility combined with a lower tissue PO(2) and lower IMP during ischemia. Our results suggest that a blood flow via the laser channels immediately after TMLR is principally possible. However, because the channels seem to occlude in the early postoperative phase, the long-term effects of TMLR are likely to be a result of other mechanisms.

Animals↗

Medium-term results of heart transplantation using donors over 63 years of age.

BACKGROUND: The continual shortage of hearts for transplantation (HTx) led to the expansion of the donor pool by accepting older donors. We compared the medium-term follow-up of patients after HTx with older hearts (over the age of 63 years) with those of patients after HTx with younger hearts. PATIENTS AND METHODS: Since April 1994 we have used hearts for HTx from donors older than the age of 63 years. Until November 1998, 309 HTx and 9 re-HTx were performed in 309 adults with a mean age of 50.7+/-10.9 years (range 17-68 years). There were 252 men and 57 women. The patients were divided into two groups: group I--donor age under 63 years (296 patients, mean age 50.4+/-11 years; mean donor age 38.1+/-13 years; mean follow-up 1.7+/-1.6 years); group II-donor age of more than 63 years (13 patients, mean age 57.4+/-5.6 years; mean donor age 65.1+/-2.1; mean follow-up 2.2+/-1.6 years). There were no differences in the etiology of heart failure, gender, or ischemia time between the groups. The patients in group II were significantly older (P = 0.008). Multiple factors were analyzed in the groups, which included changes in the left/right ventricle ejection fraction, early postoperative mortality (up to 30 days), cumulative survival rates and cardiac-dependent morbidity [myocardial infarction, malignant arrhythmias, coronary stenosis (>50% in one of the main coronary arteries) and transplant vasculopathy]. Additionally, freedom from cytomegalovirus infection (rise of titer or seroconversion) and freedom of acute rejection episodes grade > or =2 (International Society of Heart & Lung Transplantation [ISHLT]) were analyzed. RESULTS: After 1 year mean left and right ventricle ejection fraction were good in both groups and did not significantly change for up to 2 years. No Re-HTx was performed in group II. The early postoperative mortality was similar in both groups (P = 0.8). Also, the cumulative survival rates were similar in both groups (P = 0.87). Long-term cardiac morbidity was lower in group I (P = 0.03). The long-term freedom from cytomegalovirus infection in group I was significantly higher when compared with group II (P = 0.0002). The long-term freedom from severe rejection episodes was similar in both groups (P = 0.3) CONCLUSION: The study found a significant increase in long-term cardiac morbidity due to more focal coronary stenosis in group II, and freedom from cytomegalovirus infection, but did not find significant differences in the long-term survival between patients who received hearts from donors of up to 63 years of age and from those more than 63 years. The acceptance of donors older than 63 years old for HTx does not worsen the outcome of the recipients. The careful selection of older donors, with close monitoring of the coronary situation after HTx and expanded indications for revascularization of older hearts, could make HTx with older hearts, even in older recipients, a safe option.

Adolescent↗