Search PubMed⌕ Search

Biomedical subjects

R Hansen

Publications and source records attributed to R Hansen.

At least 37 records · Page 2Linked to original sources

A quick assay for monitoring recombinant hirudin during cardiopulmonary bypass in patients with heparin-induced thrombocytopenia type II : adaptation of the ecarin clotting time to the act II device.

BACKGROUND: Recombinant hirudin is increasingly advocated as a promising alternative anticoagulation for patients with heparin-induced thrombocytopenia type II during cardiopulmonary bypass. This requires monitoring of the ecarin clotting time. No commercial ecarin clotting time assay is available for clinical use. We adapted the ecarin clotting time to the easy-to-handle ACT II device. METHODS: Three different concentrations of the ecarin reagent (20, 10, 5 U/mL) were investigated as preliminary studies. Standard calibration curves were constructed for concentrations of recombinant hirudin ranging from 0 to 5 microgram/mL. In vivo samples were collected from patients with heparin-induced thrombocytopenia type II who underwent cardiopulmonary bypass, and the values were compared with the values obtained by the chromogenic method. The final concentration for the assay of 5 IU/mL ecarin was further assessed in vitro for reproducibility and the influence of variations in hematocrit, platelet count, and procoagulants. RESULTS: All three concentrations of ecarin revealed linearity to 5 microgram/mL concentrations of recombinant hirudin. The ecarin concentration of 5 U/mL revealed the best correlation (0.87) to the laboratory method, was reproducible over the whole recombinant hirudin range, and was not influenced by the variations in the in vitro setup. CONCLUSIONS: The ACT II/ecarin clotting time with an ecarin concentration of 5 U/mL is a simple and reliable assay for monitoring recombinant hirudin during cardiopulmonary bypass. Use of this assay allows a wider use of recombinant hirudin in patients with heparin-induced thrombocytopenia type II during bypass and thereby may contribute to the safer management of these patients.

Anticoagulants↗

Elimination of recombinant hirudin by modified ultrafiltration during simulated cardiopulmonary bypass: assessment of different filter systems.

UNLABELLED: Recombinant hirudin (r-hirudin) is being used increasingly in patients with heparin-induced thrombocytopenia type II. Renal failure has been demonstrated to prolong the half-life of r-hirudin and to cause bleeding in patients who have undergone cardiopulmonary bypass (CPB). We assessed the ability of different filter systems for modified ultrafiltration to eliminate r-hirudin in vitro using simulated CPB. r-Hirudin concentration was measured (chromogenic laboratory standard plus ecarin clotting time) before and after filtration, and its elimination was calculated using both controlled system flow and arterial inflow (separate pump). Four hemofilters (Renoflow II, Baxter; Arylane H4, Cobe; Ultraflux AV 600, Fresenius; and BCS 110 Plus, Iostra) and two plasmapheresis filter systems (ASAHI Plasmaflow OP, Diamed; and PF 2000 N, Gambro) were assessed (5 filters of each brand = 30 filters) in a closed in vitro CPB system applying conditions usually occurring during CPB. Ten plasmapheresis filters showed a greater ability than 20 hemofilters to eliminate r-hirudin (60%-70% vs 15%-42%) within the shortest time (80 vs 180 s). Among the four hemofilter systems, the Arylane H4 filter provided the most effective (42%) r-hirudin elimination. Elimination of r-hirudin was markedly improved using plasmapheresis systems, compared with hemofilter systems. Our findings may be relevant to patients with impaired renal function, who have been administered r-hirudin during CPB. IMPLICATIONS: Modified ultrafiltration may enhance the elimination of recombinant-hirudin, although plasmapheresis systems provide the most rapid and complete elimination of recombinant-hirudin during simulated cardiopulmonary bypass. The decision to use a specific system will ultimately depend on the prevailing clinical situation and overall health of the patient.

Adult↗

A quick anti-Xa-activity-based whole blood coagulation assay for monitoring unfractionated heparin during cardiopulmonary bypass: a pilot investigation.

UNLABELLED: We developed a quick and easy method to perform anti-Xa-activity-based whole blood assay and assessed its reliability for online monitoring of unfractionated heparins (UFHs) during cardiopulmonary bypass. Seventy-five microliters of a mixture of 1:3 large- and small-range Heptest reagent were transferred into blank cartridges of the ACT II device. The plastic flags for clot detection and stirring the sample and reagent were inserted and overlaid with 75 microL of Recalmix for recalcification. One-hundred fifty microliters of citrated whole blood were added and measurements performed. In vitro, the linearity of the test over a range of 1-8 IU/mL UFH, as well as the influence of variations in hematocrit (60%, 30%, and 20%), plasma coagulation factors (50%, 30%, and 20%) and platelets (100, 50, and 20 x 10(3)/microL) on the test results were assessed. In vivo measurements performed during cardiopulmonary bypass were compared with the chromogenic assay. The test revealed linearity to concentrations of 6 IU/mL of UFH and was not significantly influenced by the variations in the in vitro set-up despite a prolongation in samples with a hematocrit of 60%. In vivo, the correlation to the chromogenic test was R: = 0.90. The ACT II anti-Xa-UFH assay performed in whole blood was reliable when used over a wide range of conditions that could be encountered clinically. Although the test is useful for point-of-care monitoring, the necessity of individual calibrations and pipetting in the operation room requires further automation before its use in clinical practice. IMPLICATIONS: The ACT II anti-Xa-unfractionated heparin assay allows for reliable monitoring of large concentrations of UFH over a wide range of hematocrit, platelet, and coagulation factor levels. Further evaluation of this point-of-care device is indicated.

Adult↗

Reliability of the heparin management test for monitoring high levels of unfractionated heparin: in vitro findings in volunteers versus in vivo findings during cardiopulmonary bypass.

BACKGROUND: The authors assessed the heparin management test in vitro in volunteers and in vivo during cardiopulmonary bypass. METHODS: In vitro, the heparin management test was analyzed for heparin levels between 0 and 6 IU/ml using variations in hematocrit, platelets, procoagulants, and storage time. The in vivostudies consisted of two groups: In group I (cardiopulmonary bypass </= 90 min, n = 40), anticoagulation was performed according to the activated clotting time (with or without aprotinin); in group II (cardiopulmonary bypass >/= 180 min, with aprotinin) included use (n = 10) and nonuse of coumadin (n = 10) and anticoagulation according to the automated heparin dose-response assay. Tests were performed in duplicate (whole blood, two heparin management test analyzers) and compared with anti-Xa activity (plasma). RESULTS: In vitro, the results of the heparin management test (n = 1,070) correlated well with heparin concentration (r2 = 0.98). Dilution and storage time did not affect the heparin management test; a hematocrit of 60% and reduced procoagulants (10%) prolonged clotting time. In vivo, the correlation (heparin management test vs. anti-Xa) was strong in group I (r2 = 0.97 [with aprotinin] and 0.96 [without aprotinin]; n = 960) and group II without coumadin (r2 = 0.89, n = 516). In group II with coumadin, the overall correlation was r2 = 0.87 and 0.79 (n = 484), although the range varied widely (0.57-0.94, between-analyzer differences 0-47%). CONCLUSIONS: The results of the heparin management test were influenced by hematocrit, plasma coagulation factors, and the heparin level, but not by use of aprotinin. The heparin management test provided reliable values in vitro in group I, and in group II without coumadin but was less reliable in group II with coumadin.

Adult↗

Abundant defective viral particles budding from microglia in the course of retroviral spongiform encephalopathy.

A pathogenetic hallmark of retroviral neurodegeneration is the affinity of neurovirulent retroviruses for microglia cells, while degenerating neurons are excluded from retroviral infections. Microglia isolated ex vivo from rats peripherally infected with a neurovirulent retrovirus released abundant mature type C virions; however, infectivity associated with microglia was very low. In microglia, viral transcription was unaffected but envelope proteins were insufficiently cleaved into mature viral proteins and were not detected on the microglia cell surface. These microglia-specific defects in envelope protein translocation and processing not only may have prevented formation of infectious virus particles but also may have caused further cellular defects in microglia with the consequence of indirect neuronal damage. It is conceivable that similar events play a role in neuro-AIDS.

Animals↗

Recombinant hirudin as an alternative for anticoagulation during cardiopulmonary bypass in patients with heparin-induced thrombocytopenia type II: a 1-year experience in 57 patients.

OBJECTIVE: To explore the possible use of recombinant hirudin (r-hirudin) as an alternative to heparin for anticoagulation during cardiovascular surgery. DESIGN: Retrospective analysis. SETTING: Two university hospitals. PARTICIPANTS: Fifty-seven patients with heparin-induced thrombocytopenia type II (HIT II) in whom r-hirudin was used during cardiovascular surgery with cardiopulmonary bypass (CPB). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The r-hirudin concentration was monitored on-line, at the point of the patient's care using the ecarin clotting time and maintained in the range of 3 to 4 microg/mL. The r-hirudin elimination at the conclusion of CPB was augmented through modified zero-balanced ultrafiltration and forced diuresis. The duration of CPB was 63 to 246 minutes. The r-hirudin requirement per minute of CPB was 0.016 to 0.035 microg/kg/min, and the 24-hour blood drainage was 50 to 2,200 mL. Of the 57 patients, 54 fully recovered, including 9 patients who did not require any allogenic products. Four patients, all with impaired renal function, showed prolonged r-hirudin elimination and excessive bleeding and required surgical reexploration. Three patients died as a result of complications unrelated to the perioperative management. CONCLUSION: This study provides evidence that r-hirudin can be used safely and effectively for routine anticoagulation during CPB in patients diagnosed with HIT II. Almost 95% of the patients in whom it was used were discharged uneventfully. Patients with perioperative renal failure, however, showed increased bleeding.

Adult↗

Hirudin monitoring using the TAS ecarin clotting time in patients with heparin-induced thrombocytopenia type II.

OBJECTIVE: To assess the reliability of the TAS/ecarin clotting time (ECT) for on-line monitoring of r-hirudin in cardiovascular surgery with and without cardiopulmonary bypass (CPB). DESIGN: Samples were spiked with r-hirudin (0 to 5 microg/mL) and calibration curves constructed. Reproducibility was evaluated by measurement of the sample five times at each concentration. The influence of variations in hematocrit, plasma factors, and platelet count on the test results was examined. Samples were obtained from patients during cardiovascular surgery with CPB (n = 8), without CPB (n = 3), and from volunteers (n = 5) and compared with the laboratory reference tests. All tests were performed in duplicate. SETTING: Deutsches Herzzentrum Berlin. PARTICIPANTS: Five healthy volunteers and 11 patients undergoing cardiovascular surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The TAS/ECT showed linearity and reliability to an r-hirudin concentration of 5 microg/mL and was not influenced (p < 0.005) by the varying conditions of the in vitro setup. The correlation to the laboratory method was 0.74 for the CPB group and 0.87 for the non-CPB group. CONCLUSIONS: The TAS/ECT is a reliable assay for monitoring r-hirudin at the point of care. With this information, the use of r-hirudin during surgery or angioplasty should become more effective and safer.

Adult↗

Physiological and cognitive performance of soldiers conducting routine patrol and reconnaissance operations in the tropics.

The physiological and cognitive performance of acclimatized soldiers undertaking routine patrol and reconnaissance activities in the tropics was investigated. Data were obtained during a patrol and a reconnaissance exercise followed by a short assault. Ambient conditions were characterized by temperatures of 30 to 33 degrees C, low humidity (52-59%), and moderate to high solar radiation. Maximum metabolic rates during patrol were high, although the equipment carried was modest and the terrain was not severe. Rectal temperatures peaked at 38.2 and 38.4 degrees C for patrol and assault activities, respectively; peak heart rates were 160 beats min-1 for each activity. Sweat rates of approximately 9 and 14 g kg-1 body weight h-1 were recorded for patrol and assault activities, respectively. The soldiers maintained adequate hydration levels and displayed no evidence of deterioration in cognitive performance. The data show that routine operational activities in tropical conditions induced physiological strain in acclimatized soldiers. However, this strain was not maintained at hazardous levels for lengthy periods.

Acclimatization↗

Cell ashing for trace element analysis: A new approach based on ultraviolet/ozone.

We studied a new approach to cell ashing based on illuminating the specimens with a low-pressure mercury discharge lamp. We analyzed with synchrotron spectromicroscopy its effects on different physiological elements in neurobiological specimens. Our results demonstrate that carbon is removed, whereas phosphorus, calcium, potassium, and sulfur are retained and their relative concentrations are enhanced. Applied to trace elements, this technique will enhance their practical detectability.

Animals↗

Nitric oxide diffusion across membrane lungs protects platelets during simulated extracorporeal circulation.

BACKGROUND: The absence of a protective endothelial surface on membrane oxygenators during extracorporeal circulation (ECC) promotes platelet trapping and damage, leading to increased bleeding complications. We investigated the effects of transmembranous diffusion of gaseous nitric oxide (NO) on platelets during simulated ECC. MATERIAL AND METHODS: Two paired circuits were run in parallel with fresh, heparinized (1 U mL-1) blood from healthy human donors for 240 min. To one of the paired circuits, 20 ppm NO was added transmembranously. RESULTS: NO significantly attenuated platelet trapping and reduced intracircuit platelet activation evaluated by the release of beta-thromboglobulin, platelet factor 4 and soluble P-selectin. Furthermore, NO significantly preserved platelet reactivity to stimulating agents (ADP and adrenaline), evaluated as the ability to expose P-selectins and activate glycoprotein (GP)-IIb-IIIa. Nevertheless, circulating activated platelets expressing P-selectin or activated GPIIb-IIIa were not different and were not significantly increased. The mean fluorescence intensity of GPIb and GPIIb-IIIa decreased in both circuits equally. CONCLUSIONS: Transmembranous diffusion of gaseous NO revealed protective effects on platelets by reducing thrombocytopenia/pathia and preserving platelet reactivity.

Adenosine Diphosphate↗

Diagnostic accuracy and image quality using a digital camera for teledermatology.

OBJECTIVE: The study was designed to evaluate the effectiveness of digital photography for dermatologic diagnoses and compare it with in-person diagnoses. MATERIALS AND METHODS: Patients referred for specialty consultations (n = 308) were recruited from a university dermatology clinic. Patients were examined in-person by one of three board-certified dermatologists who provided clinical diagnoses. Digital photos were obtained on all patients and were evaluated as computer images by a panel of dermatologists. RESULTS: There was 83% concordance between in-person versus digital photo diagnoses. Intradermatologist concordance averaged 84%, and interdermatologist concordance averaged 81%. Decision confidence was rated as "very definite" to "definite" 62% of the time. Concordance with biopsy results was achieved in 76% of the cases. Image sharpness and color quality were rated "good" to "excellent" 83% and 93% of the time, respectively. CONCLUSION: Digital photography for store-and-forward teledermatology produces high-quality images and diagnostic concordance rates that compare favorably with in-person clinical diagnoses.

Arizona↗

Quantitative detection of porcine interferon-gamma in response to mitogen, superantigen and recall viral antigen.

Five monoclonal antibodies (mAbs) specific for porcine interferon-gamma (PoIFN-gamma) were isolated and utilized to develop a PoIFN-gamma sandwich ELISA. Specific reactivity of each mAb with E. coli derived recombinant PoIFN-gamma, but not with rPoIL-2 or rPolL-10, was confirmed in an indirect ELISA and in Western blots. Competitive ELISAs showed that mAbs P2A4 and P2C11 bound an epitope which was not recognized by mAbs P2G10, P1B7 or P2F6. The latter three mAbs were able to neutralize the ability of natural and recombinant PoIFN-gamma to induce the de novo expression of class II MHC antigens on porcine endothelial cells. To simplify the detection of biologically active porcine IFN-gamma, a sandwich ELISA was developed using the mAb P2G10 as a capture antibody and mAb P2C11 as the detecting reagent. The sensitivity of the assay for PolFN-gamma ranged from 1 to 50 ng/ml. Peripheral blood mononuclear cells (PBMC) from all pigs tested produced IFN-gamma when stimulated with either mitogen (PHA) or superantigen (SEB). In contrast, only PBMC obtained from pigs which had previously been vaccinated against PrV produced IFN-gamma in response to stimulation with this virus. Interestingly, cultures with the highest lymphoproliferative response did not necessarily have the highest level of IFN-gamma production.Furthermore, for recall viral antigen, the lymphoproliferative response decreased with time after immunization, whereas the IFN-gamma response increased. Thus, measurement of IFN-gamma production appears to be a good indicator of anti-viral immunological memory.

Animals↗

Pharmacokinetics and pharmacodynamics of single and multiple oral doses of a novel 5-lipoxygenase inhibitor (ABT-761) in healthy volunteers.

OBJECTIVE: This study evaluated the safety, pharmacokinetics and pharmacodynamics of ABT-761 [R(+)-N-[3-[5-(4-fluorophenylmethyl)-2-thienyl]-1- methyl-2-propynyl]-N-hydroxyurea], a new N-hydroxyurea analog. METHODS: This was a randomized, double-blind, placebo-controlled, single- and multiple-dose (15-day) study of ABT-761 (50 to 200 mg/day) in healthy, nonsmoking adult male volunteers. The pharmacokinetics were evaluated by investigation of the time- and dose-dependent effects of ABT-761, and the pharmacologic selectivity of ABT-761 was evaluated based on calcium ionophore-stimulated leukotriene B4 (LTB4) and thromboxane B2 (TXB2) biosynthesis ex vivo in whole blood. RESULTS: After single and multiple doses, mean observed time to reach maximum concentration values of ABT-761 ranged from 4.0 to 7.5 hours. Mean values for maximum concentration and area under the plasma concentration-time curve from 0 to 24 hours increased approximately linearly with dose. Mean terminal half-life and apparent volume of distribution during the terminal elimination phase of ABT-761 ranged from 15.4 to 17.8 hours and 69.5 to 78.9 L, respectively, and was dose independent. Steady state was reached on day 11 after multiple dosing. Less than 0.05% of unchanged ABT-761 was recovered in urine within the 24-hour period after day 15 dosing. Population ABT-761 plasma concentration at which 50% of the maximum possible inhibition was observed for LTB4 inhibition was 0.24 microgram/ml. No differences in mean TXB2 inhibition were observed between the subjects receiving ABT-761 and placebo. CONCLUSIONS: These results indicate that ABT-761 is a potent and selective inhibitor of 5-lipoxygenase and the pharmacokinetics of ABT-761 are time and dose independent between 50 and 200 mg/day after single and multiple dosing.

Administration, Oral↗

Impaired NK1.1+ T cells do not prevent the development of an IgE-dependent allergic phenotype.

BACKGROUND: The induction of TH2 immune responses is critically dependent on initial IL-4. Although crucial, the source of this early IL-4 has not been identified. One candidate is a CD1 restricted NK1.1+ T cell subpopulation which is known to produce such early IL-4. OBJECTIVES AND METHODS: The necessity of NK1.1+ T cells for the expression of an IgE-dependent phenotype was investigated in a NK1.1+ T cell deficient mouse model. The allergic phenotype was defined as immediate cutaneous hypersensitivity. It was induced by immunization of mice with ovalbumin. Mouse strains used were C57BL/6 mice and C57BL/6 mice homozygous for a targeted mutation of the beta2 microglobulin gene with consecutive loss of CD1 expression, which leads to a drastic reduction of NK1.1+ T cells. Manifestation of an allergic sensitization was assessed by intradermal allergen challenge after i.v. injection of Evans blue solution. The blue stained weal formations were quantified with the Bonitur method. In addition, the Th2 response was confirmed by the measurement of cytokines and serum immunoglobulins. The capability to produce early IL-4 was tested through the assessment of IL-4 mRNA shortly after a single challenge. RESULTS: Wild type and mutated mice did not differ in any of the immunological parameters measured. CONCLUSION: A single exposure to antigen with or without adjuvant induces early IL-4 production in C57BL/6 beta2m-/- mice. This early IL-4 is therefore independent of the presence of NK1.1+ T cells and functional MHC class I molecules and leads to IgE production and immediate cutaneous hypersensitivity.

Animals↗

Lack of cytochrome P450 1A2 interaction effect of ABT-761 on the pharmacokinetics of theophylline.

ABT-761 is a second-generation 5-lipoxygenase inhibitor for the treatment of asthma. The effects of ABT-761 on the pharmacokinetics of theophylline were assessed in 15 adult volunteers in a phase I, multiple-dose, open-label, one-period study. Subjects received a single 400-mg dose of theophylline on days 1 and 8 and 200-mg oral doses of ABT-761 once daily beginning on day 3 and continuing through day 9. The pharmacokinetic parameters of theophylline after administration of theophylline alone and concomitantly with ABT-761 were compared using a paired t-test. No statistically significant differences were observed between the pharmacokinetic parameters of theophylline administered alone and theophylline with concomitant administration of ABT-761. The 95% confidence interval for the ratio of the mean with ABT-761 dosing to the mean for theophylline alone was 0.970 to 1.127 for area under the plasma concentration-time curve and 0.887 to 1.036 for maximal plasma concentration. The lack of an inhibition effect by ABT-761 on theophylline clearance suggested that ABT-761 may have a low affinity for the cytochrome P450 1A2 isozyme, the primary isozyme responsible for theophylline metabolism.

Adult↗