[Digital radiography in thoracic diagnosis].

Technologies and performance of digital projection radiography are reviewed. Storage phosphor imaging plates can be used in existing diagnostic equipment and the resulting digital images permit the recognition of fine interstitial changes, if a high frequency edge enhancement is performed. While a generalized enhancement of low and medium spatial frequencies and a grey scale reversal do not improve the detectability of pulmonary nodules, selective enhancement of low frequencies in the mediastinal and retro-diaphragmatic areas may well improve diagnostic performance. Dose can be reduced if the resulting signal-to-noise ratio is adequate for diagnosis. Further dose savings can be achieved by the reduced number of retakes. Dual energy techniques improve the detectability and differential diagnosis of pulmonary nodules. The further development of picture archiving and communication systems (PACS) will turn the digital projection radiography into the method of choice for the diagnosis of chest disease.

Humans↗

The Saccharomyces cerevisiae SEC14 gene encodes a cytosolic factor that is required for transport of secretory proteins from the yeast Golgi complex.

We have obtained and characterized a genomic clone of SEC14, a Saccharomyces cerevisiae gene whose product is required for export of yeast secretory proteins from the Golgi complex. Gene disruption experiments indicated that SEC14 is an essential gene for yeast vegetative growth. Nucleotide sequence analysis revealed the presence of an intron within the SEC14 structural gene, and predicted the synthesis of a hydrophilic polypeptide of 35 kD in molecular mass. In confirmation, immunoprecipitation experiments demonstrated SEC14p to be an unglycosylated polypeptide, with an apparent molecular mass of some 37 kD, that behaved predominantly as a cytosolic protein in subcellular fractionation experiments. These data were consistent with the notion that SEC14p is a cytosolic factor that promotes protein export from yeast Golgi. Additional radiolabeling experiments also revealed the presence of SEC14p-related polypeptides in extracts prepared from the yeasts Kluyveromyces lactis and Schizosaccharomyces pombe. Furthermore, the K. lactis SEC14p was able to functionally complement S. cerevisiae sec14ts defects. These data suggested a degree of conservation of SEC14p structure and function in these yeasts species.

Amino Acid Sequence↗

Impact of postprocessing on the detection of simulated pulmonary nodules with digital radiography.

The authors compared the impact of five postprocessing algorithms on diagnostic performance in the detection of simulated pulmonary nodules on storage phosphor-based digital chest radiographs. Tissue equivalent paraffin nodules (0.5-2.5 cm diameter) were randomly positioned over the chest of a normal volunteer. Receiver operating characteristics (ROC) analysis of a total of 2500 observations by five readers indicated that the default unenhanced image having the appearance of a conventional chest radiograph (ROC area = 0.87 +/- 0.05) was as good as an image with moderate enhancement of medium frequencies (ROC area = 0.85 +/- 0.03), an image with reversed gray scale polarity (ROC area = 0.84 +/- 0.02), an image with reversed gray scale and moderate enhancement of medium frequencies (ROC area = 0.87 +/- 0.03), and an image with a linear rather than a sigmoid gradation curve and incorporating moderate enhancement of medium frequencies (ROC area = 0.87 +/- 0.03). The authors conclude that the specific algorithms they tested had no effect on the detection of pulmonary nodules.

Algorithms↗

"Single-exposure" dual energy digital radiography in the detection of pulmonary nodules and calcifications.

We studied the detectability of mineralized and non-mineralized simulated pulmonary nodules with dual energy digital radiography. "Soft tissue" and "bone" images (pixel size = 0.2 mm, 10 bits deep) were obtained with subtraction image processing after a single simultaneous exposure (100 kVp, 8 mAs, 17 mR skin exposure dose) of two storage phosphors with an interleaved 0.9 mm copper wafer. Three classes of paraffin-based nodules (0.5 to 3.0 cm) of varying mineral concentration (0, 120 and 190 mg/cm3 K2HPO4) were randomly positioned on the chest wall of two healthy volunteers to simulate calcified and non-calcified nodules. The average receiver operating characteristics (ROC) area of six readers (n = 2880 observations) showed that digital "bone" images (ROC area: 0.77 +/- 0.03) were significantly better (P less than 0.04) than conventional radiographs (OC Film, Lanex medium screens, 141 kVp, 19 mR skin exposure dose) (ROC area: 0.71 +/- 0.05) in detecting calcification in nodules. The unsubtracted digital images of lower kilovoltage were not superior to the 141 kVp conventional radiographs in a subgroup of two readers (ROC area: 0.73 +/- 0.02). Digital "soft tissue" images were equivalent to conventional chest radiographs in detecting soft tissue pulmonary nodules (ROC areas: 0.92 +/- 0.04 and 0.92 +/- 0.05, respectively.

Adult↗

High frequency edge enhancement in the detection of fine pulmonary lines. Parity between storage phosphor digital images and conventional chest radiography.

Fine linear structures represent a severe test of the minimum spatial resolution that is needed for digital chest imaging. We studied the comparative observer performance of storage phosphor digital imaging (1760 X 2140 pixel matrix, 10 bits deep), and conventional radiography (Lanex medium screen, Ortho C film) in the detection of simulated fine pulmonary lines superimposed on the normal chest when exposure factors were identical (20mR skin entrance dose at 141 kVp). Receiver operating characteristics analysis of 2160 observations by six readers found that high frequency edge-enhanced digital images (ROC area: 0.78 +/- 0.06) performed better than unenhanced digital images (ROC area: 0.70 +/- 0.07) (P less than 0.01 for paired t-test), and that edge enhanced digital images performed on a par with conventional radiography (ROC area: 0.78 +/- 0.09). We conclude that for the detection of fine linear structures, storage phosphor digital images can perform on a par with higher resolution conventional chest radiographs when a high frequency edge-enhancement algorithm is employed.

Adult↗

Neuropeptide-Y. A peptide found in human coronary arteries constricts primarily small coronary arteries to produce myocardial ischemia in dogs.

Neuropeptide-Y (NPY), a brain peptide, is located in the walls of human coronary arteries. This study assessed the effects of NPY on the coronary circulation in 40 chloralose-anesthetized, open-chest dogs. Intracoronary NPY (42 nmol over 5.2 min) caused a 39% reduction in coronary blood flow without changing heart rate or aortic pressure. To determine whether this vasoconstriction could produce ischemia, intramyocardial pH was measured in seven dogs (group I) and decreased from 7.45 +/- 0.06 to 7.37 +/- 0.06 pH units after NPY in the subendocardium (P less than 0.0002), and from 7.45 +/- 0.06 to 7.40 +/- 0.05 pH units (P less than 0.04) in the subepicardium of the infused zone. Left ventricular ejection fraction (LVEF), measured by radionuclide angiography, decreased from 0.52 +/- 0.08 to 0.42 +/- 0.12 U (n = 5, P less than 0.01) during NPY. NPY-induced vasoconstriction was also associated with ST-T wave changes on the electrocardiogram (ECG) in eight of nine other animals (group V). In another group of six dogs (group IV), the change in small vessel resistance accounted for 94% of the increase in total resistance, so that the primary vasoconstrictor effect of NPY was exerted on small coronary arteries. Thus, NPY, a peptide found in human coronary arteries, caused constriction of primarily small coronary arteries that was severe enough to produce myocardial ischemia as determined by ECG ST-T wave changes, and decreases in intramyocardial pH and LVEF in dogs.

Animals↗

Contrasting effects of verapamil and nifedipine on pH of ischemic myocardium in the dog.

It remains unknown whether the actions of verapamil to depress and nifedipine to enhance contractile function of ischemic myocardium influence the degree of myocardial ischemic injury. Thus, we measured intramyocardial pH using fiberoptic pH probes in 43 anesthetized open-chest dogs pretreated for 30 min with verapamil, or nifedipine in doses that decreased aortic pressure 10 to 15 mm Hg before ligation of the left anterior descending coronary artery for 15 min. Drugs were continued during the 15-min ischemic period until the animals were euthanized without reperfusion: verapamil, 10-20 micrograms/kg/min and nifedipine, 2 to 4 micrograms/kg/min i.v. Verapamil-treated dogs showed higher pH of ischemic subendocardium after 15 min ischemia (6.75 +/- 0.07) than did the nifedipine (6.48 +/- 0.04) or placebo (6.43 +/- 0.05) groups, even if the animals were paced (6.71 +/- 0.11) to prevent the negative chronotropic effect of verapamil (P less than 0.01). Neither verapamil nor nifedipine changed collateral myocardial blood flow from 0.10 +/- 0.02 in the subendocardium and 0.17 +/- 0.03 ml/min/g in the subepicardium. Left ventricular function estimated by left ventricular dp/dt was depressed 15% by verapamil and enhanced 26% by nifedipine. Thus, verapamil, but not nifedipine, relieves acidosis of ischemic myocardium after acute coronary occlusion in doses that sustain a 10 to 15 mm Hg decrease in aortic pressure. Nifedipine, in doses that produced the same 10 to 15 mm Hg decrease in mean aortic pressure, did not increase intramyocardial pH, as it enhanced contractile function, estimated by left ventricular dp/dt.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Asbestos-related pleural plaques and lung function.

The present study examines the association between asbestos-related pleural plaques and lung function in a group of workers with occupational exposure to asbestos. Exposure, smoking, and respiratory histories, chest radiographs, flow-volume loops, and single breath DLCOs were obtained on 383 railroad workers. A score based on the ILO-1980 classification system was used to quantify the extent of plaquelike thickening. In order to eliminate potential confounders, we excluded from final analysis subjects with diffuse pleural thickening (n = 10) or small irregular opacities classified as profusion 0/1 or greater (n = 6) on chest radiograph. Definite pleural plaques were observed in 22.6%. The single breath DLCO was similar in the groups with and without plaques (p = 0.0550). Decrement in FVC and the occurrence of pulmonary restriction were associated with the presence of definite plaques (p = 0.0306 and 0.0431, respectively) and with quantitative pleural score (p = 0.0135 and 0.0126), controlling for duration of asbestos exposure and smoking. A test for trend revealed an association between level of diagnostic certainty (none, suspect, definite) for pleural plaques and these measures of lung function (p less than 0.02). Our findings reveal an association between asbestos-related pleural plaques and decrement in lung function as measured by FVC and criteria for pulmonary restriction.

Asbestosis↗

A comparison of digitized storage phosphors and conventional mammography in the detection of malignant microcalcifications.

The detectability of malignant tumor-derived microcalcifications with conventional mammography was compared to that with digital images (2000 X 2510 pixels by 10 bits) derived from a storage phosphor-based digital radiography system capable of 5 line pair/mm resolution at identical exposure factors (30 kVp, 250 mAs, 65 cm film-focus distance). Microcalcifications (50-800 microns in diameter) were randomly superimposed on a preserved human breast specimen. ROC analysis based on 480 observations made by four readers indicated that the ability to detect the calcifications with digital images (ROC area = 0.871 +/- 0.066) was equivalent to conventional mammography (ROC area = 0.866 +/- 0.075) despite lower spatial resolution. With digital mammography, 62% of all clusters were correctly localized, but only 23.6% of the individual calcifications were counted. With conventional mammography 61% of all clusters were correctly localized, but significantly more of the individual calcifications (31.5%) were counted.

Breast Diseases↗

Lung lesions: correlation between viewing time and detection.

The influence of viewing time on the detectability of subtle and obvious lung cancers was studied. Frontal chest radiographs of 40 patients with subtle cancers, 40 patients with obvious cancers, and 40 healthy control subjects were shown to four observers for four different viewing times (0.25 second, 1 second, 4 seconds, and unlimited time). Receiver operating characteristic analysis was used to compare the detectability of lesions. Performance was degraded as viewing time decreased. The true-positive fractions for subtle and obvious cancers were 30% and 70% at 0.25 second and 74% and 98% at unlimited viewing time, respectively, for a given false-positive fraction of 20%. Thus, even with unlimited viewing time, the false-negative fraction for subtle cancers was 26%. The difference in detectability between subtle and obvious lung cancers was exaggerated at 1.0 second compared with 4 seconds and unlimited viewing time. The following conclusions were reached: (a) a substantial proportion of subtle lung lesions are missed, even with unlimited viewing time; (b) a large proportion of obvious lung cancers are detected with flash viewing; (c) the detectability of lesions decreases considerably as viewing time becomes less than 4 seconds; and (d) differences in detectability are exaggerated by short viewing times.

False Negative Reactions↗

Subtle lung cancers: impact of edge enhancement and gray scale reversal on detection with digitized chest radiographs.

The authors studied the impact of edge enhancement and gray scale polarity reversal on the detection of subtle lung cancers. Three experienced readers reviewed 46 biopsy-proved subtle lung cancers and 46 normal controls on chest radiographs that had been digitized into a 1,024 X 1,536-pixel matrix 8 bits deep. Receiver-operating characteristics (ROC) analysis of 1,656 pooled observations indicated that performance was best with the unmodified images (ROC area = 0.83), degraded by moderate enhancement of medium frequencies (ROC area = 0.80), and markedly impaired by severe enhancement of low frequencies (ROC area = 0.69). Gray scale polarity reversal further degraded performance (unenhanced ROC area = 0.74; moderately enhanced ROC area = 0.76; severely enhanced ROC area = 0.76). The authors conclude that edge enhancement and gray scale polarity reversal can impair the detectability of subtle lung cancers on digitized radiographs of medium resolution.

Humans↗

IgE-challenged human lung mast cells excite vagal sensory neurons in vitro.

Substances released from immunoglobin (Ig) E-stimulated mast cells are likely to be among the chemical mediators responsible for changes in the vagal component of airway reactivity. We have attempted to identify a direct role for mast cell mediators in the control of visceral afferent excitability by examining intracellular electrophysiological changes in vagal neurons after application of extracts prepared from purified and IgE-stimulated human lung mast cells (HLMC). HLMC's, applied by superfusion or by focal pressure ejection from micropipettes, reversibly enhanced the excitability of a subpopulation of rabbit visceral sensory C-fiber neurons by 1) abolishing the slow Ca2+-dependent post-spike after hyperpolarization that uniquely resides in these neurons and controls their spike frequency, 2) depolarizing the cell membrane potential, and 3) increasing membrane input resistance. Control HLMC prepared by subjecting purified human lung mast cells to normal goat serum had no measurable affects on neuronal excitability. The immunologically released constituents responsible for these excitability changes are likely to be lipid mediators, because essentially all biological activity is extractable into an organic phase after methanol-chloroform solvent extraction of the HLMC preparations. These results provide the first unambiguous evidence that products released from immunologically challenged HLMC's directly affect visceral afferent nerve cell function.

Humans↗

Single exposure simultaneous acquisition of digital and conventional radiographs utilizing unaltered dose.

We describe the simultaneous acquisition of digital and conventional radiographs with a single standard radiographic exposure. A digitizable storage phosphor (ST Imaging Plate, FujiTM) is sandwiched into a radiographic cassette (X-Omatic, KodakTM) behind a conventional radiographic film-screen combination (Lanex medium screens, OC film, KodakTM). The barium fluorohalide storage phosphor is digitized with a helium-neon laser scanner (TCR 201, ToshibaTM), and the conventional radiograph is processed in the standard fashion (M7B, KodakTM). The storage phosphor is exposed by the "wasted" radiation normally exiting the back of the film-screen combination (32% of the cassette entrance dose at 141 kVp). At a standard exposure (6.3 mAs), the conventional radiograph is of unaltered quality, and the digital image appears to have an adequate signal-to-noise ratio for chest studies despite the lower exposure dose. This technique produces twin images of identical spatial and temporal registration and avoids the added radiation exposure normally required to carry out comparative studies.

Film Dosimetry↗

Lung alterations in thoracic trauma.

The most important lung alterations associated with blunt trauma are contusion, laceration, and diffuse alveolar damage. The first two are the direct consequences of injury to the chest, while the third is the indirect result of thoracic or nonthoracic trauma. In addition to these three conditions, there are a number of epiphenomena and less common posttrauma abnormalities that are important to the radiologist involved in the care of injured patients.

Contusions↗