Search PubMed⌕ Search

Biomedical subjects

R Ganz

Publications and source records attributed to R Ganz.

At least 37 records · Page 2Linked to original sources

Anterior femoro-acetabular impingement due to acetabular retroversion. Treatment with periacetabular osteotomy.

BACKGROUND: This study was performed to evaluate whether symptomatic anterior femoro-acetabular impingement due to acetabular retroversion can be treated effectively with a periacetabular osteotomy. METHODS: The diagnosis of femoro-acetabular impingement was based on clinical symptoms, a positive anterior impingement test, and findings of acetabular rim lesions on magnetic resonance imaging. The radiographic diagnosis of acetabular retroversion was based on the cross-over and posterior wall signs. Twenty-nine hips in twenty-two patients (average age, twenty-three years) underwent a periacetabular osteotomy. An arthrotomy was performed in twenty-six hips in order to visualize intra-articular lesions and, in selected cases, to improve a low femoral head-neck offset. The range of motion of the hip was measured, clinical evaluation was performed with use of the score described by Merle d'Aubigné and Postel, and the anterior center-edge angle of Lequesne and de Sèze was measured on radiographs preoperatively and at the time of the latest follow-up. RESULTS: The duration of follow-up averaged thirty months (range, twenty-four to forty-nine months). The anterior center-edge angle of Lequesne and de Sèze decreased significantly from a preoperative average of 36 degrees (range, 26 degrees to 52 degrees ) to a postoperative average of 28 degrees (range, 16 degrees to 46 degrees ) (p = 0.002). There was a significant increase in the average range of internal rotation (10 degrees, p = 0.006), flexion (7 degrees, p = 0.014), and adduction (8 degrees, p = 0.017). The average Merle d'Aubigné score increased from 14.0 points (range, 12 to 16 points) preoperatively to 16.9 points (range, 15 to 18 points) postoperatively (p < 0.001), and the result was good or excellent for twenty-six hips. Three hips underwent subsequent surgery: one, because of early postoperative loss of reduction; one, for correction of posteroinferior impingement; and one, because of recurrent signs of anterior impingement. CONCLUSION: Periacetabular osteotomy is an effective way to reorient the acetabulum in young adults with symptomatic anterior femoro-acetabular impingement due to acetabular retroversion

Acetabulum↗

[Retrospective analysis of healing problems after reamed and unreamed nailing of femoral shaft fractures].

168 fractures of the femoral shaft treated by intramedullary nailing were analyzed retrospectively. From 1986-1992 116 fractures had been treated with the reamed AO universal nail (RFN) and from 1993-1996 52 fractures with the AO unreamed femoral nail (UFN). In 24% of the RFN-group and in 2% of the UFN-group (p < 0.0001) open reduction of the fracture had been necessary. The time to radiological consolidation was similar in both groups (18.1 weeks +/- 6.1 vs. 18.3 weeks +/- 5.7, [mean +/- SD]). Delayed unions were less frequent in the RFN-group than in the UFN-group (3% vs. 13%, p = 0.01). Non-unions occurred in the RFN-group in 4%, in the UFN-group in 8%, the difference is not statistically significant (p = 0.46). Fractures with impaired consolidation (delayed-unions and non-unions) in the RFN group were distributed randomly along the femoral diaphysis, whereas all 11 fractures with retarded healing in the UFN group were short transverse or oblique fractures localized immediately distal to the femoral isthmus. We believe that there is mainly a mechanical reason for this phenomen, in addition to fracture type and fracture localization the (insufficient) length of the unreamed nails might have impaired stability further. The different factors should be investigated in larger series. As a consequence we now treat transverse and short oblique fractures of diaphyseal femoral fractures distal to the femoral isthmus with a RFN whereas in other types and localizations of diaphyseal femoral fractures we continue to use the UFN with special attention to maximal nail diameter and length.

Adolescent↗

[Early damage to the acetabular cartilage in slipped capital femoral epiphysis. Therapeutic consequences].

Epiphyseolysis capitis femoris represents the most common disorder of the adolescent hip, which is followed by a significant rate of early osteoarthrosis. Based on intraoperative findings during the surgical management of 23 hips with epiphyseolysis, early acetabular cartilage abrasion by a cam effect and acetabular rim impingement elicited by the prominent femoral metaphysis have been identified. Both phenomena cause direct damage to the hip joint, especially during flexion and flexion/internal rotation of the hip. As evidenced during surgery, the prominent and sometimes sharp-edged anterior neck metaphysis leveling or exceeding the femoral head showed marks of contusion and the labrum revealed erosions, scars, or tears. Moreover, adjacent acetabular cartilage damage was present ranging from superficial abrasions to a full thickness cartilage loss propagating into the weight-bearing area. In all patients the femoral head cartilage was intact; no avascular necrosis was present. These findings suggest that osteoarthrosis is triggered by direct mechanical damage in the epiphysiolysis hip already during the process of slipping and that chondrolysis appears to represent just the most severe form of this cartilage damage. Consequently, we propose that treatment should not only address the avoidance of a further slippage but also the prevention of impingement and cam leading to early acetabular cartilage damage.

Adolescent↗

Femoral revision using the Wagner stem: results at 2-9 years.

We followed 39 patients with 40 revision hip arthroplasties using the Wagner stem. Mean follow-up was 65 (29-108) months. There were 12 intraoperative proximal femoral fractures, which all united, five postoperative dislocations not related to subsidence, and two loose stems that were revised. Clinical improvement was best for pain. Once the stem was osteointegrated the clinical and radiological result remained stable for up to 9 years.

Adult↗

Early lesions of the labrum and acetabular cartilage in osteonecrosis of the femoral head.

Osteonecrosis of the femoral head can be caused by a variety of disorders and affects the relatively young patient. Most studies have concentrated on the femoral changes; the sites of early lesions of the labrum and acetabular cartilage have not been recorded. We studied 17 hips with osteonecrosis and a wide congruent joint space on radiographs and by direct inspection of the femoral head, labrum and acetabular cartilage during surgery. All of the femoral heads had some anterosuperior flattening which reduced the head-neck ratio in this area. A consistent pattern of damage to the labrum and the acetabular cartilage was seen in all hips. Intraoperatively, impingement and the cam-effect with its spatial correlation with lesions of the labrum and acetabular cartilage were observed. These findings could be helpful when undertaking conservative surgery for osteonecrosis, since the recognition of early radiologically undetectable acetabular lesions may require modification of the surgical technique.

Adolescent↗

Perfusion of the femoral head during surgical dislocation of the hip. Monitoring by laser Doppler flowmetry.

We used laser Doppler flowmetry (LDF) with a high energy (20 mW) laser to measure perfusion of the femoral head intraoperatively in 32 hips. The surgical procedure was joint debridement requiring dislocation or subluxation of the hip. The laser probe was placed within the anterosuperior quadrant of the femoral head. Blood flow was monitored in specific positions of the hip before and after dislocation or subluxation. With the femoral head reduced, external rotation, both in extension and flexion, caused a reduction of blood flow. During subluxation or dislocation, it was impaired when the posterosuperior femoral neck was allowed to rest on the posterior acetabular rim. A pulsatile signal returned when the hip was reduced, or was taken out of extreme positions when dislocated. After the final reduction, the signal amplitudes were first slightly lower (12%) compared with the initial value but tended to be restored to the initial levels within 30 minutes. Most of the changes in the signal can be explained by compromise of the extraosseous branches of the medial femoral circumflex artery and are reversible. Our study shows that LDF provides proof for the clinical observation that perfusion of the femoral head is maintained after dislocation if specific surgical precautions are followed.

Adult↗

Comparison of polyethylene wear with femoral heads of 22 mm and 32 mm. A prospective, randomised study.

In this prospective, randomised study, we have compared the wear rate of cemented, acetabular polyethylene cups articulating with either a 22 mm or a 32 mm cobalt-chromium head. We evaluated 89 patients who had a total of 484 radiographs. The mean follow-up period was 71.4 months (SD 29.1). All the radiographs were digitised and electronically measured. The linear wear rate was significantly higher during the first two years and decreased after this period to a constant value. We suggest that this is partly due to a 'run-in' process caused by irregularities between surfaces of the cup and head and an initial plastic deformation of the polyethylene. The mean volumetric wear was 120.3 mm/year for the 32 mm head, which was significantly higher than the 41.5 mm3/year for the 22 mm heads. The mean linear wear rate was not significantly different. We were, however, unable to find radiological signs of osteolysis in the patients who had higher wear rates.

Acetabulum↗

Antilambda production in Au+Au collisions at 11.7A GeV/c.

We present results for antilambda and antiproton production in Au+Au collisions at 11.7 A GeV/c including spectra and extracted invariant yields for both species in central and peripheral collisions in the rapidity range 1.0<y<1.4. The antilambda yield increases from dN(Lambda;)/dy = 1.2(+0.7+0.2)(-0.6-0.2)x10(-3) in peripheral collisions to 19(+4+3)(-5-2)x10(-3) in central collisions. The direct antiproton yield is deduced from the measured total antiproton spectra to extract the ratio of antilambda-to-direct-antiproton production. The Lambda/p ratio near midrapidity increases from 0.26(+0.19+0.5)(-0.15-0.4) in peripheral collisions to 3.6(+4.7+2.7)(-1.8-1.1) in central collisions, a value larger than current theoretical estimates.

Journal Article↗

Baryon rapidity loss in relativistic Au + Au collisions.

An excitation function of proton rapidity distributions for different centralities is reported from AGS Experiment E917 for Au+Au collisions at 6, 8, and 10.8 GeV/nucleon. The rapidity distributions from peripheral collisions have a valley at midrapidity which smoothly change to distributions that display a broad peak at midrapidity for central collisions. The mean rapidity loss increases with increasing beam energy, whereas the fraction of protons consistent with isotropic emission from a stationary source at midrapidity decreases with increasing beam energy. The data suggest that the stopping is substantially less than complete at these energies.

Journal Article↗

[Hooked roof cup in revision of difficult loose hip prosthesis cups. Results after a minimum of 10 years].

The long-term results of acetabular revision after total hip arthroplasty (THA) with the use of a reinforcement ring with hook were evaluated. The study included 57 cases of surgery dating back 10 years or more. Of a total of 54 patients (57 operated hips), 18 patients (19 hips) died during the 10-year period and 2 patients (2 hips) were completely lost to follow-up. At the time of the revision surgery, the mean age of the remaining 34 patients (36 hips) was 62.5 years (range: 47-80). A THA revision was done in 25 cases and an acetabular revision only in 11 cases. The most common acetabular defect was a combined segmental and cavitary defect (n = 19), and in three cases there was pelvic discontinuity. Autologous or homologous cancellous bone grafts were used to fill acetabular cavities in 17 hip joints. Structured bone grafts, predominantly homologous bone, were used in ten cases for acetabular reconstruction. At a mean follow-up of 11.4 years (range: 10-14.5) three hip joints (8%) had undergone further revision. The revisions were done for aseptic loosening of the acetabular component in two cases and a septic loosening of both components in one case. Three further cases (8%) revealed signs of acetabular loosening. Two of these three patients were symptomatic but refused further revision surgery. In the 33 unrevised hip joints, a good or excellent clinical result with a d'Aubingé score of more than 14 points was found in 30 cases (92%). Osseous acetabular reconstruction with the use of a reinforcement ring leads to favorable results compared to other techniques. In the authors' opinion, this technique is preferable to those using oversized cups without osseous reconstruction of the acetabulum.

Acetabulum↗

Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study. Results of a clinical study with special emphasis on difficult cases.

The LISS-DF (Less invasive stabilization system-distal femur) is a new type of implant system for the treatment of distal femoral fractures according to the principles of "Minimally Invasive Surgery". A plate, pre-contoured to the anatomy, is inserted through a minimally invasive incision into the epiperiosteal space by means of an aiming device after indirect, closed fracture reduction. The implant is stabilized by insertion of screws which lock into the plate holes and prevent tilting. This is performed with the aid of an aiming device and through stab incisions. It is not necessary for a large area to be exposed at the fracture site. As part of an AO prospective multicenter study, the new system was applied to 112 patients with 116 fractures. The time to follow-up was on average 13.7 months (minimum 7 months, maximum 33 months). Fractures treated were distal femoral shaft and supracondylar femoral fractures. Eight patients died during the study of causes unrelated to the implant. Of the remaining 104 patients with 107 fractures, 96 patients with 99 fractures were available for complete follow-up (93% follow-up rate). In 90% of all cases treated and followed up, the fracture had consolidated during the period of observation. Twenty-three revision operations were necessary in 21 patients. In two cases, implant failure occurred as the result of a pseudarthrosis. The complications can be attributed in nearly all cases to the severity of the trauma and/or a lack of experience when applying the new style implant to a wider range of indications. The results of the study show that with a sound knowledge of the operative technique and careful preoperative planning this system represents an excellent, safe procedure for the treatment of almost all distal femoral fracture types including periprosthetic fractures of the distal femur. There is generally no need for primary cancellous bone grafting.

Adolescent↗

Loads acting in an intramedullary nail during fracture healing in the human femur.

The form and function of the musculo-skeletal system is closely related to the forces acting in its components. Significant forces are present in the long bones, but their magnitudes have so far only been estimated from mathematical models. Fracture fixation by means of metal implants provides an opportunity to measure the implant-born forces and to estimate the long bone forces before healing occurs. The load changes during fracture healing may provide additional information. Therefore, a telemetrized, interlocking femoral nail for wireless transmission of forces and moments acting across the fracture site was developed. The design was based on the geometry and material of a 16 mm AO nail with a circular, closed cross-section allowing full protection of the electronic circuits from the body fluids. After careful testing, it was implanted in a 33-year-old patient who had sustained a multifragmentary fracture of the left femur. Measurements at a rate of approx. 0.4 Hz were performed in different patient postures between the 2nd and 26th postoperative week. Significant axial forces and bending moments were measured during several activities such as sitting, unsupported leg elevation and partial weight bearing in a standing position. Forces orthogonal to the nail axis remained small. The reductions of the implant loads due to fracture consolidation were in the order of 50%. Dynamization of the nail did not change the forces. Even though the telemetry system did not allow for dynamic measurements and the results presented here provide data from one subject only, the new information will be useful with respect to implant design, biomechanics of fracture fixation and evaluation of healing progression.

Adult↗

Gluteus minimus-induced femoral head deformation in dysplasia of the hip.

Lateral notching of the femoral head is considered pathognomonic for spastic subluxation of the hip. Less frequently, flattening is seen with extrusion of the femoral head in nonspastic hip dysplasia. The aim of this study was to throw light on its underlying pathomechanism. On the radiographs of 297 hips with developmental dysplasia, lateral flattening of the femoral head was seen in 18 hips (6%), but notching was present in only 1. Of 7 dysplasias due to cerebral palsy, 6 showed lateral notching. The gluteus minimus was felt to be responsible for the lateral femoral head changes as the muscle counteracts lateral migration of the femoral head. Intraoperative dissection of 3 hips supported this view. 1 hip with developmental dysplasia and lateral notching was subjected to a periacetabular osteotomy. At surgery, the tendon of the gluteus minimus was found to fit tightly into the notch. Of 2 hips with spastic dysplasia, 1 presented with and the other without lateral notching. In the hip with lateral notching, the gluteus minimus had a normal appearance and it lay in the defect of the femoral head. In the hip without notching, the gluteus minimus was atrophied with signs of fatty degeneration. We therefore believe that lateral notching is a sign of hypertonicity of the gluteus minimus muscle.

Adolescent↗

Femoroacetabular impingement and the cam-effect. A MRI-based quantitative anatomical study of the femoral head-neck offset.

We have observed damage to the labrum as a result of repetitive acetabular impingement in non-dysplastic hips, in which the femoral neck appears to abut against the acetabular labrum and a non-spherical femoral head to press against the labrum and adjacent cartilage. In both mechanisms anatomical variations of the proximal femur may be a factor. We have measured the orientation of the femoral neck and the offset of the head at various circumferential positions, using MRI data from volunteers with no osteoarthritic changes on standard radiographs. Compared with the control subjects, paired for gender and age, patients showed a significant reduction in mean femoral anteversion and mean head-neck offset on the anterior aspect of the neck. This was consistent with the site of symptomatic impingement in flexion and internal rotation, and with lesions of the adjacent rim. Furthermore, when stratified for gender and age, and compared with the control group, the mean femoral head-neck offset was significantly reduced in the lateral-to-anterior aspect of the neck for young men, and in the anterolateral-to-anterior aspect of the neck for older women. For patients suspected of having impingement of the rim, anatomical variations in the proximal femur should be considered as a possible cause.

Acetabulum↗

Surgical dislocation of the adult hip a technique with full access to the femoral head and acetabulum without the risk of avascular necrosis.

Surgical dislocation of the hip is rarely undertaken. The potential danger to the vascularity of the femoral head has been emphasised, but there is little information as to how this danger can be avoided. We describe a technique for operative dislocation of the hip, based on detailed anatomical studies of the blood supply. It combines aspects of approaches which have been reported previously and consists of an anterior dislocation through a posterior approach with a 'trochanteric flip' osteotomy. The external rotator muscles are not divided and the medial femoral circumflex artery is protected by the intact obturator externus. We report our experience using this approach in 213 hips over a period of seven years and include 19 patients who underwent simultaneous intertrochanteric osteotomy. The perfusion of the femoral head was verified intraoperatively and, to date, none has subsequently developed avascular necrosis. There is little morbidity associated with the technique and it allows the treatment of a variety of conditions, which may not respond well to other methods including arthroscopy. Surgical dislocation gives new insight into the pathogenesis of some hip disorders and the possibility of preserving the hip with techniques such as transplantation of cartilage.

Adolescent↗

Development of transplanted fetal bones: differences between isografts and allografts in mice.

Allogeneic bone from bone banks frequently is used when large skeletal defects have to be bridged in orthopaedic surgery. Beside immunologic rejection of the graft, the loss in osteogenic potential caused by bone banking procedures may be a major reason for limited clinical success. Similar problems as described for bone have occurred with cartilage and osteochondral transplants. Improving the properties of allogenic bone so that its biologic activity becomes comparable to autologous bone could be substantially beneficial for the outcome of allograft transplantation. To dissect the steps involved in the integration of a fetal osteochondral graft as it matures to bone, the current study compared the development and biologic function of metatarsals from 18-day-old fetal mice freshly transplanted in three different immunologic settings. Morphologic assessment of (1) isografts and (2) allografts in nonsensitized hosts 12 days after transplantation revealed that the grafts bear an intrinsic potential to develop after transplantation. In allografts in nonsensitized hosts, however, a slight alteration in biologic activity as compared with isografts could be detected already in this early phase after transplantation by in situ hybridization for messenger ribonucleic acids encoding extracellular matrix proteins. (3) In contrast to isografts and allografts in nonsensitized hosts, morphologic features and biologic function of allografts transplanted to presensitized hosts were altered severely.

Acid Phosphatase↗

Rationale of periacetabular osteotomy and background work.

The Bernese periacetabular osteotomy is a joint-preserving procedure used after growth plate closure to correct acetabular coverage and stabilize the femoral head. The polygonal, juxta-articular osteotomy respects the vascular blood supply to the acetabular fragment and facilitates an extensive acetabular reorientation. It achieves improvement of the insufficient coverage of the femoral head, reduction of mediolateral displacement, and correction of the version of the fragment. All osteotomies are performed through the modified Smith-Petersen approach, which also allows for an anterior capsulotomy. Joint inspection not only provides information on lesions of the rim but also facilitates the control of an impingement-free range of motion after the correction. The posterior column remains partially intact, allowing minimal internal fixation of the acetabular fragment and early mobilization similar to that after an intertrochanteric osteotomy. Because the majority of this patient population consists of young women, it is important to note that the dimensions of the true pelvis and thus the potential for future vaginal delivery are preserved.

Acetabulum↗