[Isolated cartilage abrasions on the knee joint].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Ganz.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: Osteoporosis reveals a higher risk of fractures. Due to the lack of possibilities to anchor fixation elements, fracture treatment often turns out to be complicated. An experimental study served to investigate the extent to which the application of bone cement through a modified gliding screw (Dynamic Hip Screw DHS) would improve the screw anchoring in osteoporotic femoral heads. METHODS: Quasi-static compressive and torsional load tests were used to assess the desired improvement of the screw anchoring. Cadaver femur pairs served to compare the cement augmentation to the uncemented contralateral control. RESULTS: The improvement of the holding strength of the screw under static compressive and torsional load depended on the cement flow into the adjacent bone tissue. The filling with additional cement was only successful after having created a small hollow space at the screw tip with a special instrument. Consequently, under compression as well as torsion, the cement application yielded improvements from 17% up to several times as much. CONCLUSION: In the application of gliding screws in osteoporotic femoral heads, the locally limited cement application through the implant has been shown to be a biomechanical possibility to improve screw fixation.
AIM: The study was undertaken to determine the value of standard radiographs in the early stages of osteoarthritis. METHODS: Standard radiographs and arthro-MRI's from thirty hips operated on for early arthrosis (age 25-57 years) were independently analyzed by two orthopaedic surgeons and one radiologist blinded from the intra-operative findings. The radiographs were read on two occasions two months apart. The radiographic findings were then compared to the intra-operative findings. RESULTS: Intra-operatively, all cases had a labral lesion and, in all but three of the cases, there was a major acetabular cartilage lesion. Each investigator diagnosed all of the labral and/or cartilage lesions on the arthro-MRI. However, on average, the investigators judged 20% (10-35%) of the hips to be normal on the standard radiographs. The probability of detecting an abnormal hip joint was statistically significantly better with arthro-MRI in four of six readings (p < 0.05) and there was a trend in favor of the arthro-MRI in the other two readings (p < 0.1). Intra-observer agreement when using the Tönnis classification of arthrosis on standard radiographs was 0.26 (-0.1-0.62), 0.69 (0.42-0.96) and 0.83 (0.53-1) [kappa-statistic, (95% confidence interval)]. The interobserver agreement was 0.24 (-0.07-0.55). CONCLUSION: Plain radiographs in the early stages of osteoarthrosis of the hip are neither reliable nor valid to diagnose the onset of disease. Therefore, in the case of a normal radiograph and clinical suspicion of arthrosis, a "normal" radiograph does not exclude the diagnosis and an artho-MRI should be obtained for further evaluation.
AIM: In residual hip dysplasia the fovea capitis femoris lays often more cranial than in the normal hip morphology, the ligamentum capitis femoris thereby articulating with the weight-bearing area of the acetabular cartilage. The aim of this study was to quantitate this aspect with regard to its potential negative effect for the degeneration of the dysplastic acetabulum. METHOD: The relation between the fovea capitis femoris and the weight-bearing area were studied using the a.p.-pelvis view in normal and dysplastic hips. The measurements were made by digital image analysis. RESULTS: The hypothesis that the "fovea alta" is characteristic for the dysplastic hip was confirmed. In dysplastic hips the typically wider fovea lays on average 30 degrees more cranial, touching the weight-bearing area over 11 degrees. The fovea in normal hips has on average a distance of 26 degrees to the acetabular roof. In dysplastic hips the steeper roof, the tendency for decentering of the femoral head as well as a higher CCD angle explain this phenomenon to a certain degree. In a theoretical model to correct the acetabular position over the femoral head alone one quarter of the foveae would still touch the weight-bearing area. Nevertheless, in our series after periacetabular osteotomy this was never the case due to better centering. CONCLUSION: lt is our hypothesis that a "fovea alta", which further reduces the already smaller loaded cartilage surface, is one part leading to the early degeneration of the dysplastic hip. Therefore, it should be considered in biomechanical models and in the planning of corrective procedures.