Improved design of nasogastric feeding tubes.

Disappointed with the overall performance of weighted and unweighted nasogastric feeding tubes, a design programme was initiated which resulted in the development of two new nasogastric tubes, one weighted and one unweighted. The tubes were manufactured with polyurethane rather than polyvinylchloride (PVC) which permitted an increase in diameter of the internal lumen which in turn was coated with water activated lubricant to ease removal of the introducer wire. A specially modelled outflow port was incorporated into the tips of both tubes. The performance of the two new polyurethane nasogastric feeding tubes was assessed under controlled trial condition using as a reference a widely used PVC unweighted open ended tube. While intubation times were similar in patients without concurrent endotracheal intubation, it took a significantly shorter time to intubate patients with concurrent endotracheal intubation with the new weighted tube. Following tube intubation, it was possible to aspirate gastric contents significantly more often through the new polyurethane tubes (p < 0.001) than through the PVC tube, and the unweighted polyurethane tube stayed in situ longer (p < 0.05) than the PVC tube. The newly designed polyurethane nasogastric feeding tubes are the first tubes that have been shown to have advantages over the simpler type of open ended, unweighted PVC nasogastric feeding tubes.

Journal Article↗

Administration of fat emulsions with nutritional mixtures from the 3-liter delivery system in total parenteral nutrition.

A series of studies was performed to test the efficacy and safety of a parenteral lipid emulsion, Lipofundin S, when given as part of a complete nutritive mixture from the three-liter bag total parenteral nutrition (TPN) delivery system. In vitro stability studies with mixtures corresponding to high and low nutritional intakes showed the fat emulsion to be stable during refrigerated storage for at least 6 days. The clinical use of Lipofundin S in 3-liter TPN bags was studied in 39 consecutive patients requiring TPN, and there were no untoward side-effects. Nitrogen balance was maintained in patients with pancreatitis, those recovering postoperatively, and those with miscellaneous conditions. However, patients with multiple trauma remained in negative balance. The ability of sera, from patients on TPN to agglutinate Lipofundin S was compared to that from healthy controls, and acutely ill patients not on TPN. Patients on TPN showed a higher degree of in vitro creaming than acutely ill controls, and this may have been related to the severity of the underlying illness. These studies suggest that this parenteral lipid emulsion can be safely administered to patients requiring TPN when given from the 3-liter bag delivery system.

Agglutination↗

Elemental diet administered nasogastrically without starter regimens to patients with inflammatory bowel disease.

The present study questions the concept of routinely using 'starter regimens' at the outset of enteral feeding with chemically defined elemental diets. A hypertonic elemental diet with an osmolality of 630 mOsm/kg was administered by 24-hr nasogastric infusion to 12 patients with exacerbations of inflammatory bowel disease and to two patients with short bowel syndrome. Starter regimens were not used. Upper gastrointestinal symptoms of nausea, abdominal bloating, and colicky pain occurred transiently in only five of 14 patients. Stool frequency did not increase during full-strength feeding, and daily stool weights decreased significantly (p less than 0.01). These findings show that it is safe to administer undiluted hypertonic elemental diets by constant nasogastric infusion to patients with inflammatory bowel disease. Avoiding starter regimens leads to increased nutrient intake and improved nitrogen balance.

Adolescent↗

Clinical efficacy and design changes of "fine bore" nasogastric feeding tubes: a seven-year experience involving 809 intubations in 403 patients.

We report here our clinical experiences of "fine bore" nasogastric feeding tubes. Data have been collated over a 7-year period (1978-1985). A total of 403 patients were intubated on 809 occasions. In the first retrospective study, the clinical use of 491 unweighted tubes was compared with that of fifty 3.5-g weighted tubes. No advantage was found in the use of the weighted tubes. In the second prospective controlled clinical trial, these results were confirmed. Forty-six patients were intubated on 76 occasions with an 85-cm open-ended, unweighted nasogastric feeding tube (Prima, Portex UK), and 57 patients were intubated on 79 occasions with a 91-cm 3.0-g weighted tube (Entriflex, Biosearch, Raritan, NJ). Mean duration of placement was similar in each case, and 62% of both types of tubes were inadvertently removed. Without exception, all the tubes remained in the stomach throughout. Disappointed with the similar and overall performance of both types of tubes, we initiated a design program which resulted in the development of two new nasogastric tubes, one weighted and one unweighted. The tubes were manufactured with polyurethane, rather than polyvinylchloride (PVC), which permitted an increase in diameter of the internal lumen which, in turn, was coated with water-activated lubricant to ease removal of the introducer wire. A specially modeled outflow port was incorporated into the tips of both tubes. The performance of the two new polyurethane nasogastric feeding tubes was assessed under controlled trial conditions; as a reference, a widely used PVC unweighted open-ended tube was used.(ABSTRACT TRUNCATED AT 250 WORDS)

Clinical Trials as Topic↗

Assessment of an automated chemiluminescence nitrogen analyzer for routine use in clinical nutrition.

An automated method of chemiluminescence analysis of nitrogen used routinely for 4 yr. Liquid samples (urine, enteral, and parenteral feeds) required simple dilution, whereas feces required a modified acid-digestion procedure, before analysis. For urine samples, the coefficient of variation was within batch from 0.9-3.6%, and between batch 4.3-7.6%. At a sample injection rate of 2 microliter/sec, the useful dynamic range, for urine diluted 1:200, was 0-14 g N/liter. Precision for fecal nitrogen analysis was 3.8-6.7% for samples of low to high nitrogen content. The correlation between this technique and an established Kjeldahl method for fecal analysis was studied (r = 0.96, slope = 1.30). The discrepancy between the methods was due to inefficient conversion of nitrogen to NH4+ during Kjeldahl digestion of feces, rather than systematic errors in chemiluminescence analysis. Reliability was as good as for other automated clinical analyzers and sample cost was ca. 0.22 pounds. It has proved possible to analyze approximately 80 samples in the working day. The efficiency of measuring 24-hr urine urea-nitrogen (UUN) and total urine nitrogen (TUN) in patients on general wards was measured. Results were obtained on 87% of TPN days, but large variations were noted in UUN/TUN from less than 30% to greater than 90% (average 75.7%) in patients receiving TPN, and from less than 55% to 100% (average 83.8%) in patients receiving enteral nutrition. In contrast, UUN/TUN was 87.0% and 84.0% in healthy subjects, fasted or receiving iv nutrition, respectively. We therefore expect that clinical nutritionists will find increasing applications for this method of nitrogen analysis.

Autoanalysis↗

Clinical evaluation of two-liter prepacked enteral diet delivery system: a controlled trial.

Following a recent study in our Unit which showed that significantly more of prescribed enteral diet was administered from 2-liter bags than 0.51 bottles, a controlled clinical trial was undertaken to investigate further the effectiveness of the 2-liter prepackaged enteral delivery system. Forty patients with normal gastrointestinal function requiring enteral nutrition were randomized to receive nasogastrically 2-liter/day of polymeric diet (2000 kcal, 12 g N) either from a presterilized 2-liter PVC bag (Express EFI Ltd, UK) or from two 1-liter rigid plastic containers filled with cans of Clinifeed 400 (Roussel Laboratories Ltd, UK). The actual volumes of feed infused were monitored in patients fed for 5 days or more. Both nursing and dietetic staff preferred the 2-liter bags which were more convenient to prepare and use. Significantly larger quantities of prescribed diet were delivered from the 2-liter bags than from the 1-liter containers (p less than 0.001). It was concluded that the 2-liter bag system was potentially more convenient and nutritionally efficacious than 1-liter containers. Although the incidence of microbial contamination associated with the 2-liter bags was low, measures to maintain the sterility of this system may need to be more stringent.

Aged↗

Spontaneous transpyloric passage and performance of 'fine bore' polyurethane feeding tubes: a controlled clinical trial.

Certain groups of patients requiring enteral nutritional support are at increased risk of regurgitation and pulmonary aspiration of feed. Positioning of enteral feeding tubes distal to the pylorus has been advocated as a method of reducing such complications. Various techniques have been suggested to achieve postpyloric siting. Reports have indicated that lengthening the tube or altering the distal end tip configuration, by varying the tip profile or by the addition of a weight, may facilitate spontaneous transpyloric passage of the tube. This prospective controlled clinical study using three new polyurethane tubes demonstrates that the frequency of spontaneous transpyloric passage of the tube is not affected by tip profile or by the addition of a weight. Indeed, with all three tube designs only about one-third had passed spontaneously through the pylorus at 24 hr. Once through the pylorus the unweighted tube stayed in position significantly longer than the weighted tubes (p less than 0.005). We suggest that in those patients requiring post-pyloric feeding, endoscopic or fluoroscopic techniques should be used to position the tubes at the time of insertion, and that an unweighted tube should be used to prolong tube usage.

Clinical Trials as Topic↗