A video-based system for acquiring biomechanical data synchronized with arbitrary events and activities.

A video-based data acquisition and interactive multimedia data extraction system are described for measuring and synchronizing large quantities of biomechanical analog data with arbitrary events and activities. Analog signals from up to 32 channels are digitized, frequency-shift key (FSK) coded, and recorded directly onto the audio tracks of a video tape in synchronization with the video information. The data acquisition system includes an A/D converter that digitizes up to 16 multiplexed channels of 8-b data at a fixed sample rate between 60 and 960 Hz, and an FSK modem that transfers the data onto one of two VHS high fidelity (20 Hz-20 kHz bandwidth) audio tracks. Twenty megabytes of digitized data and time codes, along with associated video and normal audio are contained on a conventional 120-min video tape. An analyst interactively reviews the video tape off-line using a computer-controlled VCR and identifies specific events that divide arbitrary activities into time segments. The computer automatically extracts the biomechanical data corresponding to each time segment for further processing or analysis. This system is useful for ergonomics, gait analysis, sports medicine, sleep laboratory, biomechanics, or any application where complex visual events are synchronized with low-frequency analog data.

Analog-Digital Conversion↗

Functional psychomotor deficits associated with carpal tunnel syndrome.

A reliable task was developed for investigating functional deficits associated with carpal tunnel syndrome (CTS). A rapid pinch and release psychomotor task utilizing muscles of the hand innervated by the median nerve was administered using a strain gauge dynamometer and providing limited force feedback. The motor performance characteristics studied were speed and force control. An experiment was conducted for studying the effects of force level, hand dominance, test-retest reliability, learning, and inter-subject variability using 13 subjects free from any hand disabilities or symptoms. A companion study was also conducted using 17 normal subjects and ten subjects diagnosed having CTS to investigate differences between CTS and control subjects. Dominant hands performed 4% to 8% better than the non-dominant hands by having a greater pinch rate, a smaller overshoot force, and less time above the upper force level and below the lower force level. Control subjects performed 25% to 82% better than CTS subjects. Age contributed 6% of the total variance for pinch rate and 7% of the total variance for the time below the lower force level. The results suggest that people suffering from CTS may experience similar functional psychomotor deficits in daily living and manual work activities.

Adult↗

Exposure assessment of biomechanical stress in repetitive manual work using frequency-weighted filters.

A quantitative exposure assessment strategy for physical stress associated with repetitive manual tasks is proposed using continuous biomechanical data measured directly from electrogoniometers or force sensors. This paper describes an efficient method for reducing large quantities of biomechanical data into a quantifiable metric that accounts for recognized musculoskeletal exposure factors, including repetitiveness, postural or forceful exertion stress, and duration. A frequency domain approach is used for averaging elemental data recorded for repetitive cycles. Parameters for frequency-weighted filters are developed using psychophysical data for equivalent discomfort levels resulting from repetitive movements of different amplitudes and frequencies. These filters enable continuous biomechanical data to be filtered and integrated, resulting in a single quantity corresponding to psychophysical response characteristics for repetitive motion stress. It is anticipated that a similar approach may be used for epidemiological response characteristics. Applications of this theory may make it possible for assessing exposure to physical stress in a manner analogous to the way in which sound level meters are used for measuring exposure to acoustic noise. Repetitive wrist flexion and localized discomfort was used for demonstrating the feasibility of this approach. Suitable data reduction techniques are necessary for evaluating work methods, job designs, and for conducting large scale detailed epidemiological investigations of cumulative trauma disorder risk factors. Frequency-weighted filters based on human response to physical stress at different frequencies can greatly simplify exposure analysis and ultimately may make it possible for quantitative exposure limits to be established.

Adult↗

An analytical method for characterizing repetitive motion and postural stress using spectral analysis.

The availability of small, inexpensive electrogoniometers has made wrist posture measurement during repetitive manual work practical. Efficient analytical methods, however, are not currently available for quantifying the degree of repetitiveness and the interaction with postural stress. Spectral analysis was investigated as a method for characterizing repetitive wrist motion and postural stress using a simple peg transfer task. Wrist posture was controlled by adjusting the pegboard location and by having subjects reach over an obstruction. Work pace was externally controlled using an auditory signal. Angular wrist flexion/extension and ulnar/radial deviation was recorded using a 60 Hz sample rate. Power spectra were computed by stratifying data segments into individual work elements, divided by break points associated with the task. Peak spectral magnitudes and frequency components corresponded closely with joint displacement amplitudes and repetition rates. Spectrum DC component magnitudes were directly related to sustained wrist postures.

Cumulative Trauma Disorders↗

Pistol grip power tool handle and trigger size effects on grip exertions and operator preference.

Finger and palmar forces were measured during actual pneumatic nutrunner operation using a strain gauge dynamometer. Eighteen student subjects were assigned to one of three categories based on hand length. Two triggers and four handle spans were presented randomly. Handle span affected maximal and submaximal grip force. As span increased from 4 cm to 7 cm, average peak finger force increased 24%, peak palmar force increased 22%, and average finger and palmar tool-holding forces increased 20%. When an extended trigger was used, average peak finger force decreased 9%, peak palmar force decreased 8%, finger tool-holding force decreased 65%, and palmar tool-holding force decreased 48%. Hand size affected grip strength (MVC), grip force, and exertion level (force/MVC). Holding exertion level was maximum for large-handed subjects using a 4-cm handle and for small-handed subjects using a 7-cm handle. Subjective handle span preference increased as hand size increased. A similar experiment was performed using 11 factory workers.

Adult↗

Gain effects on performance using a head-controlled computer input device.

The purpose of this study was to use a Fitts' task to (1) determine how control-display gain influences performance using a head-controlled computer input device; (2) compare relative sensitivity to gain and optimal gain between head control and hand/arm control; and (3) investigate control-display gain interactions with other task factors including target width, movement amplitude and direction. The task was a discrete target acquisition task using circular targets of 2.9 mm, 8.1 mm, and 23.5 mm, movement amplitudes of 24.3 mm and 61.7 mm, and eight radial directions including 0 degrees, 45 degrees, 90 degrees, 135 degrees, 180 degrees, 225 degrees, 270 degrees, and 315 degrees. Each device was operated at four gain levels. Ten subjects participated. The results indicated that gain had a significant effect on movement time for both types of pointing devices and exhibited local minimums. Discrete target acquisition at all gains was aptly described using Fitts' Law for both input devices. The mouse gain resulting in minimum movement time and RMS cursor deviation was between 1.0 and 2.0. The minimum movement time and RMS cursor deviation for the head-controlled pointer occurred at a gain between 0.3 and 0.6. Average movement time at the optimal head-controlled pointer gain had a slope of 169 ms/bit and was more than 76% greater than at the optimal mouse gain with a slope of 135 ms/bit. In addition, average RMS displacement was more than 27% greater for the head-controlled pointer at its optimal gain setting than for the mouse. Gain had the greatest effect for small target widths and long movement amplitudes using the head-controlled pointer. Average movement time increased 37% when increasing the head-controlled pointer gain from 0.6 to 1.2 for the small target width, but only increased 0.3% when increasing gain for the large target width. Average movement time also increased 12% when decreasing the head-controlled pointer gain from 0.3 to 0.15 for the long movement amplitude, but decreased 0.3% when decreasing gain for the short movement amplitude.

Ergonomics↗

External finger forces in submaximal five-finger static pinch prehension.

Small conductive polymer force sensors were attached to the distal phalangeal pads for measuring individual finger forces exerted during submaximal static pinch. A linear force summing strain gauge dynamometer for measuring resultant five-finger pinch force was grasped vertically using a neutral wrist posture. Individual finger forces were measured at fixed total pinch force levels of 10%, 20%, and 30% of maximum voluntary exertion using pinch spans of 45 mm and 65 mm. Total pinch force and individual finger forces were also measured while similarly grasping the dynamometer and supporting fixed weights for 1.0 kg, 1.5 kg, and 2.0 kg loads using pinch spans of 45 mm and 65 mm. The index and middle fingers exerted more than 3 N greater average force than the ring and small fingers for the fixed total pinch force task. No significant individual finger force differences were observed at the 10% maximum voluntary exertion level, however both the index and middle fingers exerted more than 5 N greater force than the ring and small fingers at the 30% maximum voluntary exertion level. The average contribution of the index, middle, ring, and small fingers were 33%, 33%, 17%, and 15%, respectfully, for the fixed total pinch force task. As exertion level increased from 10% to 30%, the contribution of the middle finger was not constant increasing from 25% to 38%. Total pinch force increased from 15 N to 30 N when the load weight increased from 1.0 kg to 2.0 kg.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Maximal dynamic range electrotactile stimulation waveforms.

A new method to measure the dynamic range of electrotactile (electrocutaneous) stimulation uses both steepest ascent (gradient) and one-variable-at-a-time methods to determine the waveform variables that maximize the subjective magnitude (intensity) of the electrotactile percept at the maximal current without discomfort for balanced-biphasic pulse bursts presented at a 15-Hz rate. The magnitude at the maximal current without discomfort is maximized by the following waveform (range tested in parentheses): number of pulses/burst = 6 (1-20), pulse repetition rate within a burst = 350 Hz (200-1500), and phase width = 150 microseconds (40-350). The interphase interval (separation between positive and negative phases in a biphasic pulse) does not affect dynamic range from 0-500 microseconds. The number of pulses/burst has a large effect on the perceived dynamic range when this is measured using a subjective-magnitude-based algorithm, whereas it has little effect on the traditional dynamic range measure, i.e., (maximal current without discomfort)/(sensation threshold current). The perceived stimulus magnitude at the maximal current without discomfort is approximately twice as strong with 6 pulses/burst as it is with 1 pulse/burst (a frequently-used waveform).

Bias↗

A linear force-summing hand dynamometer independent of point of application.

Theory, design and construction details are presented for a versatile strain gauge hand dynamometer. What distinguishes this instrument is that sensitivity is completely independent of the location. Force is applied so it is capable of linearly summing forces exerted at multiple locations along the length of the active area of the dynamometer. In addition to including the basic principles of this transducer, a template for the instrument and an accompanying spread sheet is provided for computing transducer response characteristics for instruments of arbitrary size, including sensitivity and force range, depending on particular measurement requirements. Variations of this dynamometer were constructed and used for measuring grip and pinch strength, as well as for measuring submaximal exertions produced during manual activities and tasks. Because this dynamometer is compact and rigid, one of suitable dimensions may be substituted as a handle for tools or objects handled during work for directly measuring applied exertions and grip force. Examples of practical applications of this instrument are given for hand biomechanics, hand tool ergonomics, and clinical evaluations.

Journal Article↗

A conductive polymer sensor for measuring external finger forces.

This paper describes the construction and use of a durable and thin force sensor that can be attached to the palmar surface of the fingers and hands for studying the biomechanics of grasp and for use in hand injury rehabilitation. These force sensors were constructed using a modified commercially available conductive polymer pressure sensing element and installing an epoxy dome for directing applied forces through a 12 mm diameter active sensing area. The installation of an epoxy dome was effective for making the sensors insensitive to contact surfaces varying from 25 to 1100 mm2 and a 16 mm radius surface curved convex towards the finger. The completed sensors were only 1.8 mm thick and capable of being taped to the distal phalangeal finger pads. They were calibrated on the hand by pinching a strain gage dynamometer. The useful range was between 0 and 30 N with an accuracy of 1 N for both static loading and normal dynamic grasp activities. The sensor time constant was 0.54 ms for a step force input. Because of varying offset voltages every time the sensors were attached, these sensors should be calibrated on the hand before each use. The sensors were used for measuring finger forces during controlled pinching and lifting tasks, and during ordinary grasping activities, such as picking up a book or a box, where the useful force range and response for these sensors were adequate.

Biomechanical Phenomena↗

Ridge detection tactility deficits associated with carpal tunnel syndrome.

A ridge detection threshold task was administered to patients diagnosed as having carpal tunnel syndrome for studying performance in an occupationally relevant functional tactile inspection task. Thresholds were compared with a reference group of subjects not having carpal tunnel syndrome symptoms, performing the same task. The threshold detection task used the method of limits for studying the effects of carpal tunnel syndrome, rate of ridge height changes, ridge gradient, and direction of shearing against the skin on ridge detection thresholds for a repeated measures factorial experimental design. Sixteen carpal tunnel syndrome hands and 30 normal hands were studied. Average ridge detection threshold was 0.08 mm for the normal subjects and increased to 0.20 mm for the carpal tunnel syndrome subjects. No significant age effect was observed. These results suggest that workers having carpal tunnel syndrome may not detect an edge or surface defect in a tactile inspection task unless it was more than twice as high as detected by workers without CTS.

Adult↗

A 16-channel 8-parameter waveform electrotactile stimulation system.

We have developed a general-purpose electrotactile (electrocutaneous) stimulation system as a research tool for studying psychophysiological performance associated with various stimulation waveforms. An experimenter-defined command file specifies the stimulation current and waveform of each of the 16 channels. The system provides burst onset delay of 0-20 ms, phase current of 0-50 mA, interphase interval of 0-1000 microseconds, number of pulses per burst from 1-100, pulse repetition rate of 0.1-25 kHz, phase width of 2-1000 microseconds, and functionally-monophasic pulses (with zero dc current) or balanced-biphasic pulses (with equal positive and negative phases). The system automatically delivers the desired stimulation, prompts the subject for responses, and then logs subject responses. Key features of the system are 1) very flexible choice of bursts of pulsatile waveforms, 2) real-time control of all of the waveform parameters as mathematical functions of external analog inputs, and 3) high-performance electrode-driver circuitry.

Electric Stimulation↗

Use of computer aided drafting for analysis and control of posture in manual work.

Computer aided design (CAD) in conjunction with digitised anthropometric manikins can be used for analysis and control of stressful work postures, one of the most frequently cited occupational risk factors of upper extremity cumulative trauma disorders. This paper describes the use of macros for manipulating manikins and workstation components and for designing the workplace. AutoCAD, a popular computer aided design software package, was used to demonstrate the feasibility of these concepts. Specifically, macros are used for drawing work equipment using parametric designs, manipulating manikins and analysing jobs. In comparing the macros to the use of primitive CAD commands, the macros not only decrease the amount of time needed to create workstation components, but they also make the task easier for the user and decrease the risk of errors. Despite the limitation of anthropometric data and manikins, CAD is an effective method for identifying postural stresses and redesigning the workstation to control the identified stresses.

Journal Article↗

Vibration exposure for selected power hand tools used in automobile assembly.

A practical method for assessing vibration exposure for workers operating vibrating hand tools on an automobile assembly line is presented. Vibration exposure is difficult to assess directly using many fast Fourier transform (FFT) spectral analyzers because of long task cycle times. Exposure time cannot be accurately estimated using time standards because of the high variability between operators and work methods. Furthermore, because workers frequently move about and get into inaccessible spaces, it is difficult to record vibration without interfering with the operation. A work sampling method was used for determining vibration exposure time by attaching accelerometers to the tools and suspending a battery-operated digital data logger from the air hose. Vibration acceleration and frequency spectra for each tool were obtained off-line replicating actual working conditions and analyzed together with exposure time data for determining individual worker vibration exposure. Eight pneumatic vibrating power hand tools, representing tools commonly used in an automobile assembly plant, were studied. Spectra for the rotary and reciprocating power tools and had large distinct dominant fundamental frequencies occurring in a narrow frequency range between 35 Hz and 150 Hz. These frequencies corresponded closely to tool free-running speeds, suggesting that major spectral component frequencies may be predicted on the basis of speed for some tools.

Automobiles↗

A method for evaluating head-controlled computer input devices using Fitts' law.

The discrete movement task employed in this study consisted of moving a cursor from the center of a computer display screen to circular targets located 24.4 and 110.9 mm in eight radial directions. The target diameters were 2.7, 8.1, and 24.2 mm. Performance measures included movement time, cursor path distance, and root-mean-square cursor deviation. Ten subjects with no movement disabilities were studied using a conventional mouse and a lightweight ultrasonic head-controlled computer input pointing device. Average movement time was 306 ms greater (63%) for the head-controlled pointer than for the mouse. The effect of direction on movement time for the mouse was relatively small compared with the head-controlled pointer, which was lowest at 90 and 270 deg, corresponding to head extension and head flexion, respectively. Average path distance and root mean square displacement was lowest at off-diagonal directions (0, 90, 180, and 270 deg). This methodology was also shown to be useful for evaluating performance using an alternative head-controlled input device for two subjects having cerebral palsy, and measured subtle performance improvements after providing a disabled subject with lateral torso support.

Adult↗

Muscle response to pneumatic hand tool torque reaction forces.

Surface electromyography was used for studying the effects of torque reaction force acting against the hand, on forearm muscle activity and grip force for five subjects operating right angle, air shut-off nutrunners. Four tools having increasing spindle torque were operated using short and long torque reaction times. Nutrunner spindle torque ranged between 30 Nm and 100 Nm. Short torque reaction time was considered 0.5 s while long torque reaction time was 2 s. Peak horizontal force was the greatest component of the reaction force acting against the hand and accounted for more than 97% of the peak resultant hand force. Peak hand force increased from 89 N for the smallest tool to 202 N for the largest tool. Forearm muscle rms EMG, scaled for grip force, indicated average flexor activity during the Torque-reaction phase was more than four times greater than the Pre-start and Post Shut-off phases, and two times greater than the Run-down phase. Flexor EMG activity during the Torque-reaction phase increased for increasing tool peak spindle torque. Average flexor rms EMG activity, scaled for grip force, during the Torque-reaction phase increased from 372 N for the 30 Nm nutrunner to 449 N for the 100 Nm nutrunner. Flexor rms EMG activity averaged during the Torque-reaction phase and scaled for grip force was 390 N for long torque reaction times and increased to 440 N for short torque reaction times. Flexor rms EMG integrated over the torque reaction phase was 839 Ns for long torque reaction times and decreased to 312 Ns for short torque reaction times. The average latency between tool spindle torque onset and peak initial flexor rms EMG for long torque reaction times was 294 ms which decreased to 161 ms for short torque reaction times. The average latency between peak tool spindle torque, just prior to tool shut-off, and peak final rms EMG for long torque reaction times was 97 ms for flexors and 188 ms for extensors, which decreased for short torque reaction times to 47 ms for flexors and 116 ms for extensors. The results suggest that right angle nutrunner torque reaction forces can affect extrinsic hand muscles in the forearm, and hence grip exertions, by way of a reflex response.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Ergonomics and the effects of vibration in hand-intensive work.

Along with ergonomic factors, such as forceful and repeated exertion and certain postures, vibration has been cited as a factor of chronic nerve and tendon disorders such as carpal tunnel syndrome and tendinitis. The arguments for the contribution of vibration come from epidemiologic studies, clinical case analyses, and studies of short-term effects. It is well established that vibration stimulates muscle contraction, which is called the tonic vibration reflex. It is also known that vibration reduces tactility and that tactility affects the amount of force exerted to hold or manipulate a given object. For localized vibration exposure of the hand and arm to occur, the hand must grip a vibrating object. Vibration may increase the risk of chronic tendon and nerve disorders by increasing the force exerted in repetitive manual tasks. This close relationship between force and vibration, and difficulties in measuring force and vibration in manual work, makes it very difficult to determine their relative contributions in epidemiologic and clinical studies.

Carpal Tunnel Syndrome↗