Search PubMed⌕ Search

Biomedical subjects

R G Martin

Publications and source records attributed to R G Martin.

At least 37 records · Page 2Linked to original sources

Regulation of the multiple antibiotic resistance (mar) regulon by marORA sequences in Escherichia coli.

The mar operon and adjacent sequences were subcloned on a low-copy-number plasmid to identify essential regulatory elements. A 1.1-kbp fragment containing 133 bp of the operator-promoter region (marO), the full marRA gene sequences, and only 10 of 72 marB codons provided a dela mar strain with normal repressibility and inducibility and the ability to beget mar constitutive mutants.

Bacterial Proteins↗

Purification and regulatory properties of MarA protein, a transcriptional activator of Escherichia coli multiple antibiotic and superoxide resistance promoters.

Expression of the marA or soxS genes is induced by exposure of Escherichia coli to salicylate or superoxides, respectively. This, in turn, enhances the expression of a common set of promoters (the mar/soxRS regulons), resulting in both multiple antibiotic and superoxide resistance. Since MarA protein is highly homologous to SoxS, and since a MalE-SoxS fusion protein has recently been shown to activate soxRS regulon transcription, the ability of MarA to activate transcription of these genes was tested. MarA was overexpressed as a histidine-tagged fusion protein, purified, cleaved with thrombin (leaving one N-terminal histidine residue), and renatured. Like MalE-SoxS, MarA (i) activated the transcription of zwf, fpr, fumC, micF, nfo, and sodA; (ii) required a 21-bp "soxbox" sequence to activate zwf transcription; and (iii) was "ambidextrous," i.e., required the C-terminal domain of the alpha subunit of RNA polymerase for activation of zwf but not fumC or micF. Thus, the mar and soxRS systems use activators with very similar specificities and mechanisms of action to respond to different environmental signals.

Bacterial Proteins↗

Thin-section contrast-enhanced computed tomography accurately predicts the resectability of malignant pancreatic neoplasms.

A prospective diagnostic study was designed to determine the ability of thin-section contrast-enhanced computed tomography (CT) to predict the resectability of malignant neoplasms of the pancreatic head. Patients with a presumed resectable pancreatic neoplasm referred during a 21-month period were studied with abdominal CT performed at 1.5-mm section thickness and 5-mm slice interval during the bolus phase of intravenous contrast enhancement. CT criteria for resectability included the absence of extrapancreatic disease, no evidence of arterial encasement, and a patent superior mesenteric-portal venous confluence. Of 145 patients evaluated, 42 were considered to have resectable tumors by CT criteria, and 37 (88%) underwent potentially curative pancreaticoduodenectomy. Six patients were found to have a microscopically positive retroperitoneal resection margin; no patient had a grossly positive resection margin. Five (12%) of 42 patients were found at laparotomy to have unresectable, locally advanced or metastatic tumors. Thin-section contrast-enhanced CT is an essential component of the preoperative evaluation for pancreaticoduodenectomy and can prevent needles laparotomy in most patients with locally advanced or metastatic disease.

Adenocarcinoma↗

Efficacy of diclofenac sodium ophthalmic solution versus placebo in reducing inflammation following cataract extraction and posterior chamber lens implantation.

One hundred forty-eight patients were enrolled in a randomized, prospective, placebo-controlled clinical trial evaluating the efficacy of diclofenac sodium (Voltaren Ophthalmic) in reducing ocular inflammation following extracapsular cataract extraction with posterior chamber intraocular lens implantation. Eligible patients were enrolled and randomized (2:1 diclofenac:placebo) if the sum of anterior chamber cells plus flare one day postoperatively (baseline) was at least four. None of the patients received concomitant steroidal anti-inflammatory treatment. The 99 patients receiving diclofenac sodium had significantly greater improvement from baseline in summed flare plus cell score than the 49 placebo patients at two to five days and seven to nine days after baseline. Similarly, diclofenac sodium patients had significantly less post-baseline conjunctival erythema and ciliary flush than placebo patients. Significantly more diclofenac sodium patients than placebo patients showed moderate to marked improvement from baseline in overall assessment of inflammatory response. Forty-nine percent of placebo patients but only 17% of diclofenac patients were considered therapeutic failures (P < .001). By five to seven days, 82% of diclofenac sodium patients and 59% of placebo patients had corrected visual acuities of 20/40 or better (P < .001). There were no clinically important differences in mean intraocular pressure at any visit.

Aged↗

The effects of respirator use on workers' productivity in a mentally stressing task.

This article quantitatively determines the effect of wearing half-facepiece respirators, the most widely used type in industry, on worker productivity and efficiency in a mentally stressing task. An experiment investigated the performance of 10 subjects in a task simulating inspection of printed circuit boards. Accuracy and mean reaction time were tested automatically. Paced and unpaced task simulations were used to evaluate the effect of wearing the respirator on response times and the accuracy of subjects' responses for different product complexities and quality levels. The results indicated that wearing the respirator, in general, did not affect the speed or accuracy of subjects performing simulated inspection tasks. Pacing the task resulted in longer response times but did not affect accuracy. More complex products resulted in longer response times but also did not affect accuracy. High product quality resulted in longer response times and a higher miss rate. In terms of accuracy and reaction times a statistically significant difference was found in the performance of subjects.

Adult↗

When keratometric measurements do not accurately reflect corneal topography.

The keratometer has been the standard for measuring corneal curvature for decades and until recently seemed sufficient for most clinical situations. However, it measures only four points from a small region of the cornea and assumes that the cornea is symmetrical. We document with a number of examples a variety of clinical cases in which keratometry provides either incomplete or frankly misleading information. We believe that corneal topography is now an invaluable clinical tool and will replace the keratometer in standard clinical practice.

Astigmatism↗

Effect of cataract wound incision size on acute changes in corneal topography.

A randomized prospective trial compared keratometric and visual outcomes for 196 patients receiving 3.2 mm, 5.0 mm, or 6.0 mm incisions for cataract removal and intraocular lens implantation. There were no statistically significant differences among the groups preoperatively or at one to two days or three to six months postoperatively in mean keratometric cylinder, no differences postoperatively in surgically induced cylinder, and no differences in best-corrected visual acuity. Significantly more (P < .01) 3.2 mm cases (75%) had uncorrected visual acuity of 20/40 or better at one to two days postoperatively than 5.0 mm (50%) or 6.0 mm cases (47%). Computer-assisted corneal topographic images were available for the last 56 patients enrolled. Patients receiving 3.2 mm incisions had significantly less wound-related flattening than other patients (P < .05) and tended to have fewer surgically induced changes in corneal shape overall. Changes identified by corneal topography were inconsistent with keratometrically assessed cylinder in 14 patients.

Acute Disease↗

Effect of posterior chamber intraocular lens design and surgical placement on postoperative outcome.

Intraocular lens (IOL) design, optical configuration, and placement have potential effects on postoperative outcome. Laboratory studies have suggested that one-piece, biconvex designs may reduce or delay posterior capsular opacification and that in-the-bag fixation of the posterior chamber IOL may reduce inflammation. To document the clinical significance of IOL design and placement, we conducted a randomized, prospective, clinical trial. Six hundred uncomplicated capsulorhexis and phacoemulsification patients were randomized in a three-factor design to receive an IOL that was one-piece or three-piece, had a biconvex, plano-convex, or laser ridge optic, and was bag-or sulcus-fixated. Treatment differences were related to lens placement. Patients with bag-fixated IOLs had less posterior capsular opacification, fewer YAG laser capsulotomies, a higher percentage of centered lenses, less inflammation, and fewer late posterior capsular striae than those with sulcus-fixated IOLs. In the latter group, patients with three-piece IOLs had fewer posterior capsular striae at three months postoperatively. All six occurrences of haptic loop distortion were in patients with three-piece IOLs. Patients with the one-piece design had less late inflammation than those with the three-piece design. Fewer YAG capsulotomies were necessary at one year in patients with the biconvex design than in those with the plano-convex or laser ridge configurations. Operative complications, endothelial cell loss, and postoperative complications were not IOL-related.

Adult↗

Effect of small incision intraocular lens surgery on postoperative inflammation and astigmatism. A study of the AMO SI-18NB small incision lens.

A single center, single surgeon, randomized, prospective clinical trial was performed comparing the effectiveness of small (3.5 mm to 4.0 mm) incision intraocular lens surgery and a larger (6.0 mm) incision in improving uncorrected visual acuity and reducing post-operative inflammation and surgically induced astigmatism. One hundred twelve eligible unilateral cases were randomized to receive a 3.5 mm to 4.0 mm incision with implantation of an Allergan Medical Optics three-piece SI-18NB silicone lens (56 cases) or a 6.0 mm incision with implantation of a three-piece biconvex poly(methyl methacrylate) lens (56 cases). At one day after surgery, significantly (P less than .01) more patients with 3.5 mm incisions had 20/40 or better uncorrected visual acuity than patients with 6.0 mm incisions (45% vs 20%). Forty percent of patients with 6.0 mm incisions vs 14% of patients with 3.5 mm incisions had visual acuities of 20/100 or worse. At one day after surgery, the larger incision group had significantly higher (P less than .01) mean keratometric cylinder (2.28 diopters vs 1.28 diopters in the small incision group). The two groups were comparable by three months. Laser flare/cell meter measurements were taken for each group but showed no significant differences in mean flare or cell measurements between the groups.

Aged↗

Milk and water intakes of foals sucking grazing mares.

Intakes of milk and milk nutrients were determined for 8 foals at 11-18 days of age and for 10 foals at 30-44 days and 60-74 days of age while sucking grazing mares. Water intakes (sources other than milk) of the foals were determined at 30-44 days and 60-74 days of age. Five of the 10 mares were fed a protein supplement (24% crude protein) in addition to grazing during the stud season. The protein supplement did not influence foal intakes of milk and milk nutrients, milk composition, weight gains of the mares or the growth rate of the foals. Foal milk intakes increased (P less than 0.05) from 16.9 kg/day at 11-18 days to 18.1 kg/day at 60-74 days of age. The water intakes of the foals increased (P less than 0.01) from 3.9 kg/day at 30-44 days to 5.5 kg/day at 60-74 days of age. Total fluid intakes per kg foal liveweight were 246, 202 and 172 g at 11-18, 30-44 and 60-74 days of age, respectively. For each kg of weight gain, foals consumed 12.8, 15.7 and 16.4 kg milk at 11-18, 30-44 and 60-74 days of age. Stage of lactation had a significant effect on the total solids, lactose and protein content of milk. The fat and gross energy content of milk remained constant.

Animal Feed↗

Visual, astigmatic, and inflammatory results with the Staar AA-4203 single-piece foldable IOL: a randomized, prospective study.

One hundred twelve unilateral cataract extraction patients were randomly assigned to receive either a one-piece Staar Model AA-4203 silicone intraocular lens (IOL) implanted through a 3.2-millimeter incision, or a one-piece polymethylmethacrylate IOL implanted through a 6.0-millimeter incision. Follow up was 96% at 1 day postoperatively, 90% at 3 months, and 70% at 1 year. Fifty-three percent of the eyes that received a smaller incision could see 20/40 or better uncorrected at 1 day, as compared with 19% of the eyes that received a 6-millimeter incision (P < .01). At 3 months, significantly more smaller-incision eyes could still see 20/40 or better (P = .03). The smaller-incision eyes also had significantly less surgically-induced astigmatism at both 1 day (P < .01) and 3 months (P = .02), and had significantly less flare (P < .01) and cellular reaction (P = .04) at 1 day.

Aged↗

Effects of a protein deficient diet and urea supplementation on lactating mares.

Six lactating mares were fed either a low protein diet or the same diet with added urea ad libitum over 71 days. The quantity consumed by the mares, milk intakes of their foals, milk composition, plasma urea nitrogen (PUN), mare liveweight changes and foal growth rates were measured. The mares were unable to consume sufficient quantities of either diet to meet their nitrogen requirements and all lost weight. Adding urea to the diet significantly increased PUN in mares and foals, raised urea concentrations in the milk, decreased the mares' feed intake and significantly increased their weight loss. Low concentrations of protein were measured in milk from mares on both diets. Milk intakes of all the foals were reduced and they showed poor growth rates.

Animal Feed↗

Caveat emptor.

Explore the source record for details and available documents.

Biological Science Disciplines↗

Sequence similarities among monkey ori-enriched (ors) fragments.

Nucleotide sequences have been determined for eight ors (ori-enriched sequence) fragments isolated from monkey DNA by a method that was designed to enrich for origins of DNA replication [Kaufmann et al., Mol. Cell. Biol. 5 (1985) 721-727]. Evidence has been presented that some or possibly all of these sequences can serve, albeit inefficiently, as oris in vivo [Frappier and Zannis-Hadjopoulos, Proc. Natl. Acad. Sci. USA 84 (1987) 6668-6672]. Two of the fragments were found to contain the long terminal repeat-like elements of the 'O-family' of moderately repetitive sequences that are present in human DNA as a transposon-like element [Paulson et al., Nature 315 (1985) 359-361]. Extensive pair-wise comparisons of the sequences failed to detect any statistically significant common sequences, except for long asymmetrically distributed A + T-rich stretches. Nonetheless, when the ors fragments were examined for the presence of published consensus sequences, seven of eight were found to contain the control sequence described by Dierks et al. [Cell 32 (1983) 695-706], and the same seven of eight were found to contain both the scaffold attachment region T consensus [Gasser and Laemmli, Cell 46 (1986) 521-530] and the minimal Saccharomyces cerevisiae autonomously replicating sequence consensus [e.g., Palzkill and Newlon, Cell 53 (1988) 441-450].

Amino Acid Sequence↗

Occluded peripheral arteries: clinical utility of argon laser recanalization.

Optically diverged direct argon laser light energy was used prior to conventional balloon angioplasty to recanalize 30 occluded peripheral arteries in 26 patients. Three of five (60%) iliac and 22 of 25 (88%) femoropopliteal lesions ranging in length from 1 to 47 cm (mean, 17.3 cm) were successfully treated, for an overall technical success rate of 83%. In the femoropopliteal system, 13 of 14 (93%) procedures in lesions less than 20 cm and nine of 11 (82%) procedures in lesions greater than 20 cm were treated successfully. No statistically significant differences in success rate based on lesion site, lesion length, degree of lesion calcification, or severity of peripheral vascular disease were found. Major complications were a laser perforation resulting in treatment failure in one case (3%) and a successfully treated distal embolus in another (3%). No reocclusions occurred in the immediate postoperative period. While long-term follow-up will be required to assess continued patency, this system can potentially increase the number of patients amenable to conventional balloon angioplasty and is currently advocated as an alternative to amputation in patients in whom surgical bypass grafting is contraindicated or unfeasible.

Aged↗

Scientific hype.

Explore the source record for details and available documents.

Newspapers as Topic↗

Is asteroid hyalosis ocular gout?

In 76 cases of asteroid hyalosis, seven (9.2%) had gout, eight (10.5%) had close relatives with gout, and two (2.6%) were in both categories. Three of the gouty seven were receiving gout medications. Serum uric acid measurements were elevated in 28.3% of the 46 cases (60.5%) measured. In the 68 monocular cases (89.5%), whites (57 cases) showed no right/left predilection, but blacks (11 cases) had 100% left eye involvement (P less than .001). From a review of 49,000 records, prevalence rates were calculated for discrete age and sex groups. Females under age 60 had no asteroid hyalosis. After age 60 they had a constant prevalence rate of one case per 600 (0.15%). Males of all ages had a higher prevalence rate than females, increasing with age to one per 126 (0.79%) in the 80-or-older group. In all 76 patients, the male-to-female ratio was 1.45:1. Among whites it was, 1.74:1, and among blacks, 0.63:1.

Age Factors↗