Search PubMed⌕ Search

Biomedical subjects

R G Dong

Publications and source records attributed to R G Dong.

7 recordsLinked to original sources

Modeling of time-dependent force response of fingertip to dynamic loading.

An extended exposure to repeated loading on fingertip has been associated to many vascular, sensorineural, and musculoskeletal disorders in the fingers, such as carpal tunnel syndrome, hand-arm vibration syndrome, and flexor tenosynovitis. A better understanding of the pathomechanics of these sensorineural and vascular diseases in fingers requires a formulation of a biomechanical model of the fingertips and analyses to predict the mechanical responses of the soft tissues to dynamic loading. In the present study, a model based on finite element techniques has been developed to simulate the mechanical responses of the fingertips to dynamic loading. The proposed model is two-dimensional and incorporates the essential anatomical structures of a finger: skin, subcutaneous tissue, bone, and nail. The skin tissue is assumed to be hyperelastic and viscoelastic. The subcutaneous tissue was considered to be a nonlinear, biphasic material composed of a hyperelastic solid and an invicid fluid, while its hydraulic permeability was considered to be deformation dependent. Two series of numerical tests were performed using the proposed finger tip model to: (a) simulate the responses of the fingertip to repeated loading, where the contact plate was assumed to be fixed, and the bone within the fingertip was subjected to a prescribed sinusoidal displacement in vertical direction; (b) simulate the force response of the fingertip in a single keystroke, where the keyboard was composed of a hard plastic keycap, a rigid support block, and a nonlinear spring. The time-dependent behavior of the fingertip under dynamic loading was derived. The model predictions of the time-histories of force response of the fingertip and the phenomenon of fingertip separation from the contacting plate during cyclic loading agree well with the reported experimental observations.

Bone and Bones↗

Dynamic interaction between a fingerpad and a flat surface: experiments and analysis.

Many neural and vascular diseases in hands and fingers have been related to the degenerative responses of local neural and vascular systems in fingers to excessive dynamic loading. Since fingerpads serve as a coupling element between the hand and the objects, the investigation of the dynamic coupling between fingertip and subjects could provide important information for the understanding of the pathomechanics of these neural and vascular diseases. In the present study, the nonlinear and time-dependent force responses of fingertips during dynamic contact have been investigated experimentally and theoretically. Four subjects (2 male and 2 female) with an average age of 24 years participated in the study. The index fingers of right and left hands of each subject were compressed using a flat platen via a micro testing machine. A physical model was proposed to simulate the nonlinear and time-dependent force responses of fingertips during dynamic contact. Using a force relaxation test and a fast loading test at constant loading speed, the material/structural parameters underlying the proposed physical model could be identified. The predicted rate-dependent force/displacement curves and time-histories of force responses of fingertips were compared with those measured in the corresponding experiments. Our results suggest that the force responses of fingertips during the dynamic contacts are nonlinear and time-dependent. The physical model was verified to characterize the nonlinear, rate-dependent force-displacement behaviors, force relaxations, and time-histories of force responses of fingertips during dynamic contact.

Adult↗

Simulation of mechanical responses of fingertip to dynamic loading.

Extended exposure to mechanical vibration has been related to many vascular, sensorineural and musculoskeletal disorders of the hand-arm system, frequently termed 'hand-arm vibration syndrome' (HAVS). A two-dimensional, nonlinear finite element model of a fingertip is developed to study the stress and strain fields of the soft tissue under dynamic loading, that may be encountered while grasping and operating a hand-held power tool. The model incorporates the most essential anatomical elements of a fingertip, such as soft tissue, bone, and nail. The finger is assumed to be in contact with a steel plate, simulating the interaction between the fingertip and a vibrating machine tool or handle. The soft tissue is assumed to be nonlinearly visco-elastic, while the nail, bone, and steel plate are considered to be linearly elastic. In order to study the time-dependent deformation behavior of the fingertip, the numerical simulations were performed under ramp-like loading with different ramping periods and sinusoidal vibrations of the contacting plate at three different frequencies (1, 10, and 31.5 Hz). Owing to relatively large deformations of the soft tissue under specified static and dynamic loading, Lagrangian large deformation theory was applied in the present analysis. The effects of the loading rate and the frequency of the sinusoidal vibration on the time-dependent strain/stress distributions in the different depth within the soft tissue of the fingertip are investigated numerically. Our simulations suggest that the soft tissue of the fingertip experiences high local stress and strain under dynamic loading and the fingertip may separate from the vibrating contact surface due to the viscous deformation behaviour of the soft tissue. For a given deformation, the high frequency loading produces a higher stress in the tissues compared to that obtained at a low frequency loading. The present model may serve as a useful tool to study the mechanism of tissue degeneration under vibratory loading encountered during operation of hand-held power tools.

Computer Simulation↗

A method for reducing adaptor misalignment when testing gloves using ISO 10819.

OBJECTIVES: International standard ISO 10819 was established in order to quantify the vibration attenuation characteristics of anti-vibration gloves. One problem that exists with the standard is possible misalignment of the palm adaptor that is placed underneath the test glove. If the adaptor becomes misaligned, the measured glove transmissibility will be lower than the actual value. A tri-axial accelerometer was installed in the adaptor and was used as the basis for providing visual feedback of the adaptor alignment to the test subjects. The objective of this study was to test the hypothesis that adaptor misalignment could be reduced by providing feedback to the test subjects. METHODS: Eight male volunteers (mean age 24.8 yr) were used in the study. Each subject performed two sets of tests: the standard ISO 10819 glove test and the modified version. Three different anti-vibration gloves were tested. Glove transmissibility and adaptor misalignment were calculated for each glove. A three-way analysis of variance was used to analyze the results. RESULTS: A comparison of the two testing methods showed that the modified glove testing method did reduce misalignment significantly, which, in turn, resulted in an increase in the measured glove transmissibility. CONCLUSIONS: The proposed method greatly improved the standard deviation of transmissibility and made the test results more consistent.

Adult↗

Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.

Hand-arm vibration syndrome (HAVS) has been associated with prolonged exposure to vibration transmitted to the human hand-arm system from hand-held power tools, vibrating machines, or hand-held vibrating workpieces. The biodynamic response of the human hand and arm to hand transmitted vibration (HTV) forms an essential basis for effective evaluations of exposures, vibration-attenuation mechanisms, and potential injury mechanisms. The biodynamic response to HTV and its relationship to HAVS are critically reviewed and discussed to highlight the advances and the need for further research. In view of its strong dependence on the nature of HTV and the lack of general agreement on the characteristics of HTV, the reported studies are first reviewed to enhance an understanding of HTV and related issues. The characteristics of HTV and relevant unresolved issues are discussed on the basis of measured data, proposed standards, and measurement methods, while the need for further developments in measurement systems is emphasized. The studies on biodynamic response and their findings are grouped into four categories based on the methodology used and the objective. These include studies on (1) through-the-hand-arm response, expressed in terms of vibration transmissibility; (2) to-the-hand response, expressed in terms of the force-motion relationship of the hand-arm system; (3) to-the-hand biodynamic response function, expressed in terms of vibration energy absorption; and (4) computer modeling of the biodynamic response characteristics.

Arm↗

Analysis of skin deformation profiles during sinusoidal vibration of fingerpad.

Vibrotactile perception threshold measurement has been widely used to diagnose the severity of peripheral neuropathy associated with hand-arm vibration syndrome and sensory losses in stroke and diabetic patients. The vibration perception threshold is believed to be influenced by many factors, such as contact force and vibration frequency. The present study is intended to analyze, theoretically, the time-dependent deformation profile of skin surface, strain distributions within soft tissue, and response force of a fingertip when it is stimulated by a probe vibrating with a sinusoidal movement. A two-dimensional finite element model, which incorporates the essential anatomical structures of a finger: skin, subcutaneous tissue, bone, and nail, has been proposed to analyze the effects of vibration amplitude, frequency, and preindentation on the dynamic interaction between the fingerpad and vibrating probe. The simulation results suggest that the fraction of time over which the skin separates from the probe during vibration increases with increasing vibration frequency and amplitude, and decreases with increased preindentation of the probe. The preindentation of the probe has been found to significantly reduce the trend of skin/probe decoupling. The simulation results show reasonably consistent trends with the reported experimental data.

Adaptation, Physiological↗

Efficacy of endoscopic sinus surgery in the management of patients with asthma and chronic sinusitis.

An association between chronic sinusitis and asthma has been noted for many years, although the precise nature of the relationship is poorly understood. Earlier studies, using traditional surgical techniques, have demonstrated subjective improvement in asthmatic complaints. Reports demonstrating improvement following endoscopic sinus surgery for chronic sinusitis are rare. To report our experience with endoscopic sinus surgery and asthmatics, we reviewed the charts of 75 consecutive patients with asthma and chronic sinusitis who underwent endoscopic sinus surgery between 1994 and 1996. Study criteria included the following: chronic sinusitis, one year preoperative and one year postoperative follow-up from endoscopic sinus surgery, and asthma requiring inhaled steroids and oral prednisone for control. Many patients required prednisone bursts for control of asthma. Number of days and total dose of oral prednisone were used as objective measures of asthma control. Number of weeks of antibiotics was used as a relative measure of sinusitis. Fourteen of the 15 patients meeting study criteria decreased their postoperative prednisone requirement by total number of days (preoperative 84 versus postoperative 63 days [p < 0.0001]). Postoperatively, patients required an average of 1300 mg less oral prednisone (p < 0.033). Antibiotic use also decreased, with an average use of antibiotic nine weeks preoperatively versus seven weeks postoperatively (p < 0.045). This study provides corroborative objective evidence that, at least in the short term, endoscopic sinus surgery is efficacious in the management of patients with chronic sinusitis and asthma.

Adolescent↗