Search PubMed⌕ Search

Biomedical subjects

R G Craig

Publications and source records attributed to R G Craig.

At least 37 records · Page 2Linked to original sources

Application of flow cytometry to determine the cytotoxicity of urethane dimethacrylate in human cells.

The effects of an oligomer, urethane dimethacrylate (UDMA), on two human cell lines were studied using flow cytometry (FCM). Untreated and treated cultures of propidium iodine-stained KB (epidermal oral carcinoma cells) and human foreskin fibroblast (HFF) cells were analyzed for cellular DNA content. Concentrations of 10 and 25 microM of UDMA slightly perturbed the KB cell cycle progression at 24 and 48 h of incubation. However, the effect of 50 microM was more pronounced at the latter incubation time period. In cell growth experiments, the sublethal concentrations (10 and 25 microM) produced inhibition of KB cell growth rate at a moderate level, which resulted in the prolongation of cell population doubling time. Significant inhibition of cell growth occurred when 50 microM (lethal concentration) was used. Data obtained from the cell cycle perturbation analysis, evidenced by FCM, correlated with the extent of inhibition in KB cell growth rates. The effects of sublethal concentrations were reversible during a 24 h period of oligomer withdrawal from culture medium. In contrast, the effects of 50 microM were not reversible. In HFF cells the depletion of S phase in the cell cycle was the major effect of 50 microM of UDMA. It was concluded that FCM technology is an ideal and practical approach for studying the cytotoxicity of components of dental composites.

Carcinoma↗

In vitro effects of metal ions on cellular metabolism and the correlation between these effects and the uptake of the ions.

The effects of Ag+1, Au+3, Cd+2, Cu+2, Ga+3, In+3, Ni+2, Pd+2, and Zn+2 on DNA synthesis, protein synthesis, succinic dehydrogenase activity, and total cellular protein of mammalian fibroblasts were measured for exposures less than 12 h. The rates at which these cellular functions responded to metal ion exposure were compared and related to the uptake rate of the ions into the cells. These rates of response were significantly different: DNA synthesis decreased the fastest, followed by protein synthesis, succinic dehydrogenase activity, and total protein. This order of response was similar for most metal ions. At 4 h, the rate of uptake of the metal ions correlated most closely with depression of succinic dehydrogenase activity, whereas at 8 h, the uptake correlated most closely with depression of protein synthesis. The similar response of cells to all metal ions may imply that these ions act on cells by similar mechanisms. The rates of uptake of Ag+1, Cu+2, and Zn+2 were sufficiently fast that in vivo exposures of tissues to these metals for periods less than 12 h would be capable of disrupting cellular metabolism.

Animals↗

Physical properties of three maxillofacial materials as a function of accelerated aging.

This study compares the tensile strength, elongation, Shore-A hardness, and tear resistance of three silicone maxillofacial materials before and after aging to provide comparative data for evaluation of new or experimental elastomers. The materials evaluated were MDX-4-4210, Factor II (A-2186), and Cosmesil. Tests were conducted 24 hours after specimen preparation and were repeated after aging for 900 hours in a Weather-Ometer device. Five samples were made for each material under all test conditions. After testing, mean values were calculated for all materials under all test conditions and were compared by two-way analysis of variance and Tukey intervals at p < or = 0.05.

Analysis of Variance↗

Sorption and solubility of 12 soft denture liners.

The long-term stability of a soft denture liner depends to a large extent on the sorption and solubility of the liner. Because sorption and solubility are accompanied by a volumetric change, bacterial infestation, hardening, and color change, it is a physical property of importance. The purpose of this investigation was to determine the sorption and solubility of 12 soft denture liners (Verno-Soft, Super Soft, ProTech, Soft-Pak, Flexor, Novus, Molloplast-B, Durosoft, Justi Soft, Velvesoft, VinaSoft and Prolastic). They include nine copolymers, two silicones and one polyphosphazene fluoroelastomer. The sorption and solubility test was performed as outlined in American Dental Association (ADA) specification 12 for denture base polymers. Five specimens of each material were tested and data were collected at 1 week, 1 month, 3 months, 6 months, and 1 year. Sorption data varied from 0.2 to 5.6 mg/cm2 at 1 week; 0.3 to 12.5 mg/cm2 at 1 month; 0.1 to 22.0 mg/cm2 at 3 months; 0.1 to 13.6 mg/cm2 at 6 months; and 0.1 to 35.7 mg/cm2 at 12 months. Solubility data varied from 0.0 to 0.4 mg/cm2 at 1 week; 0.1 to 0.8 mg/cm2 at 1 month; +0.1 to 1.2 mg/cm2 at 3 months; 0.0 to 1.9 mg/cm2 at 6 months; and +0.2 to 2.3 mg/cm2 at 1 year. A statistical analysis of the data by two-way ANOVA and calculated Tukey intervals showed significant differences between materials at all time intervals. The results of this study have clinical implications because the sorption and solubility may affect the long-term life expectancy of the soft denture liner.

Absorption↗

Uptake of metal cations by fibroblasts in vitro.

Atomic absorption spectroscopy was used to assess uptake of Ag+1, Au+4, Cd+2, Cu+2, In+3, Ni+2, Pd+2, and Zn+2 by in vitro cultures of Balb/c 3T3 fibroblasts as a function of concentration of the cations in cell-culture medium. Reversibility of this uptake was also measured. Metal cations exhibited a 400-fold difference in their tendency to accumulate in the cells; In+3 tended to accumulate the most, whereas Pd+2 accumulated the least. Uptake of the cations in the cells increased linearly with the concentration of the cation in the medium for all cations up to their 50% toxicity concentrations. Reversal of this uptake was slower than that of the initial uptake for three cations studied in more detail (Cd+2, In+3, and Ni+2). The duration of the initial exposure affected the proportion of the metal cations that were retained by the cells 5 h after the cations were removed from the medium. The proportion of retained Cd+2 did not change when the initial exposure was increased from 2 h to 6 h, whereas the proportion of retained In+3 decreased and Ni+2 increased over the same period. The tendency of the cells to accumulate these cations correlated with their cytotoxic potency (measured previously).

Animals↗

Strategies to affect bone remodeling: osteointegration.

Osteointegration was defined as a "direct structural and functional connection between ordered living bone and the surface of a load-carrying implant." Although osteointegration was meant originally to describe a biologic fixation of the titanium dental implants, it is now used to describe the attachment of other materials used for dental and orthopedic applications as well. Analyses of material-bone interface showed that osteointegrated implants can have an intervening fibrous layer or direct bone apposition characterized by bone-bonding depending on the composition and surface properties of the biomaterial. This article reviews biologic (host tissue properties and response), biomechanical, and biomaterial factors affecting osteointegration. Biologic factors include the quality of bone. Biomaterial factors include the effect of material composition on the bone-material interface. Suggested areas for future research include determining the correlation between oral bone status and osteoporosis, the effect of gender, age, and endocrine status (e.g., osteoporosis) on implant success or failure, the effect of calcium phosphate coating composition and crystallinity on in vivo performance of implants, the factors contributing to accelerated osteointegration, and development of osteoinductive implants.

Aging↗

Physical property comparison of 11 soft denture lining materials as a function of accelerated aging.

Soft denture-lining materials are an important treatment option for patients who have chronic soreness associated with dental prostheses. Three distinctly different types of materials are generally used. These are plasticized polymers or copolymers, silicones, or polyphosphazene fluoroelastomer. The acceptance of these materials by patients and dentists is variable. The objective of this study is to compare the tensile strength, percent elongation, hardness, tear strength, and tear energy of eight plasticized polymers or copolymers, two silicones, and one polyphosphazene fluoroelastomer. Tests were run at 24 hours after specimen preparation and repeated after 900 hours of accelerated aging in a Weather-Ometer device. The data indicated a wide range of physical properties for soft denture-lining materials and showed that accelerated aging dramatically affected the physical and mechanical properties of many of the elastomers. No soft denture liner proved to be superior to all others. The data obtained should provide clinicians with useful information for selecting soft denture lining materials for patients.

Biocompatible Materials↗

The effect of repeated stretching on the force decay and compliance of vulcanized cis-polyisoprene orthodontic elastics.

Compliance measurements, used in the past to measure the viscoelastic properties of dental impression materials, were used to assess these properties in vulcanized cis-polyisoprene orthodontic elastics, and the results were compared with traditional force decay measurements. Both methods were also used to evaluate the effect of repeated stretching on these elastics. Compliance measurements successfully characterized the viscoelastic behavior of the elastics, and the results agreed with force decay measurements. Repeated stretching significantly reduced the force and the compliance of the elastics. There was no statistical difference in the force or compliance measurements after the elastics were stretched more than 200 times. Stretching for 1000 cycles of 400% extension reduced elastic force by approximately 12%.

Analysis of Variance↗

The effect of cell monolayer density on the cytotoxicity of metal ions which are released from dental alloys.

The effect of cell density (number of cells per unit area of a monolayer culture) on the in vitro cytotoxicity of metal ions which are known to be released from dental materials was investigated. The effects of cell density (1) may explain previous discrepancies in in vitro tests, (2) may be important in wound healing where cell density changes over time, and (3) may help clarify the mechanisms of cytotoxicity of metal ions. Balb/c 3T3 fibroblasts were plated at cell densities ranging from 10,000-80,000 cells/cm2 and were exposed to 8 concentrations of 10 different metal ions. After 24 h, the succinic dehydrogenase activity and DNA synthesis were measured to quantify the cytotoxic effect. Higher cell densities markedly reduced the sensitivity of these fibroblasts to all metal ions except Al+3 and Zn+2, but the magnitude of the reduction was metal dependent. In addition, the DNA synthesis was inhibited more than the succinic dehydrogenase activity for all metal ions except Zn+2. The unique effect of cell density on each metal ion supported the hypothesis that the effect was not simply caused by a dilution of the number of metal ions per cell. Given these results, the effect of cell density should be carefully selected in in vitro cytotoxicity tests.

3T3 Cells↗

Accuracy of models for indirect posterior restorations.

Effects of materials and techniques on the accuracy of models used to make indirect restorations was measured using a 4-unit posterior model containing a MOD and full crown preparation. Improved stone and fast setting epoxy dies backed with either improved stone or a thermoplastic hot melt stone were made from single-viscosity addition silicone impressions. Technique variations included heating or not heating the impression, cooling and pouring dies and placement of the hot melt stone on set or unset epoxy. The dimensions of the MOD (L, W, H) and of the crown (W, H) dies were measured at 1 and 24 h. No clinically significant changes occurred between 1 and 24 h. The stone control reproduced the dimensions of the master die best, and models made by pouring epoxy into the impression followed by immediate pouring of the hot melt stone gave the poorest reproduction. Other variations in technique using epoxy for the anatomical portion gave no practical differences in accuracy. Of the epoxy dies, those prepared from a previously heated impression with hot melt poured after the epoxy set had the best values; however, epoxy dies were smaller than stone dies. The fast set epoxy was noteworthy for rapid processing and sharp detail, however, negative changes for W and H of the crown and H and L of the MOD showed that a die spacer would be essential in the preparation of indirect restorations.

Crowns↗

In vitro synergistic, antagonistic, and duration of exposure effects of metal cations on eukaryotic cells.

Effects of duration of exposure of single metal cations (Ag+1, Cd+2, Cu+2, Ga+3, Ni+2, and Zn+2) on 3H-thymidine (3H-Tdr) incorporation and 3-[4,5-dimethyl-thiazol-2yl-]-2,5-diphenyl tetrazolium bromide-formazan (MTT-f) production in cultured murine fibroblasts (Balb/c 3T3) were investigated, and the synergistic and antagonistic effects of two metal cations applied simultaneously to the fibroblasts were assessed. The effects of duration of exposure were quantified using TC50 values (concentration of an element required to cause 50% toxicity compared with controls) measured after 24, 48, or 72 h. Using MTT-f production, Cd+2, Cu+2, Ga+3, and Ni+2 showed significantly lower TC50 values with increasing time of exposure, whereas the TC50 values for Ag+1 and Zn+2 remained constant. The TC50 values using 3H-Tdr incorporation exhibited a similar pattern with time of exposure, but the effects were less pronounced. The TC50 values for 3H-Tdr and MTT-f tended to equalize at 72 h. All combinations of cations tested (Ag-Cu, Ag-Zn, Ag-Ni, Cu-Zn, Cu-Ni, Ga-Ni, and Cu-Cd) exhibited synergistic and antagonistic effects as measured by MTT-f production. Synergistic and antagonistic effects were not necessarily mutually exclusive in the same system.

3T3 Cells↗

Stress analyses of four prefabricated posts.

A two-dimensional photoelastic stress analysis method was applied to study the relative magnitude of stress and concentration induced by four commercially available posts for endodontically treated teeth. Three types of threaded posts; VLock, Radix Anchor, and Flexi-Post, and one nonthreaded prefabricated post, the Para-Post Plus post were tested. Stress was recorded at installation, at vertical and inclined load, and the threaded posts were compared with the nonthreaded post. At installation and on loading, stress was induced where posts were in contact with the model. Higher apical stresses were demonstrated for the Para-Post Plus post whereas the threaded posts concentrated stress where they engaged the model through threads or flanges.

Dental Stress Analysis↗

Comparison of the physical properties of 11 soft denture liners.

Soft denture liners are an important treatment option for patients who have chronic soreness associated with their prostheses. The objective of this study is to determine the tensile strength, elongation, hardness, tear strength, and tear energy of eight plasticized polymers or copolymers, two silicones, and one polyphosphazene fluoroelastomer. Tests were made on samples that were stored in a humidor for 24 hours before testing. The range of data is as follows: tensile strength, 8 to 85 kg/cm2; percent elongation, 150% to 542%; hardness, 25 to 95 Shore-A units; tear energy, 1.43 x 10(6) to 40.4 x 10(6) ergs/cm2; tear resistance, 2.6 to 26.3 kg/cm. It can be concluded that (1) the data obtained can be useful in characterizing the performance of soft denture liners, (2) there is considerable variability in the physical/mechanical properties of soft denture liners, and (3) the required essential properties for soft denture liners are as yet not known.

Chemical Phenomena↗

Comparison of bond strength of six soft denture liners to denture base resin.

The bond strength of six commercial soft denture liners was evaluated using a modified tensile test. The soft denture liners investigated were Prolastic, VinaSoft, Flexor, Molloplast-B, Novus, and Super-Soft. The samples were processed according to the manufacturers' instructions to cured denture base resin (polymethyl methacrylate; PMMA). The soft denture liners were 10 x 10 x 3 mm and were processed between two PMMA blocks. The samples were placed in tension until failure. The mode of failure, cohesive or adhesive, was also recorded. The results of this study showed that the bond strength is related to the components of the materials. Prolastic, VinaSoft, and Flexor had the lowest bond strength to cured PMMA and ranged from 9.6 to 11.3 kg/cm2. Super-Soft, Novus, and Molloplast-B demonstrated better bond strengths and ranged from 16.7 to 17.6 kg/cm2. The bond strength of Novus could be improved by using the recommended bonding agent and bonded Novus at 26.1 kg/cm2 had the highest bond strength of all materials tested.

Adhesiveness↗

Viscosity of monophase addition silicones as a function of shear rate.

The viscosity of monophase addition silicone impression materials was measured as a function of shear rate. The setting of mixed catalyst and base was prevented by addition of a small amount of phenyl propiolic acid. All products showed a 6- to 10-fold decrease in viscosity with an increasing shear rate (shear thinning). The addition of phenyl propiolic acid had little or no effect on the viscosity of three materials. However, when added to the catalyst or base only of two products, it increased their viscosity and exaggerated the shear thinning effect.

Dental Impression Materials↗

Precision of and new methods for testing in vitro alloy cytotoxicity.

Previous studies have utilized in vitro alloy cytotoxicity tests to evaluate dental casting alloys. The purposes of this study were to: (1) evaluate the precision of the optical density and visual tests previously used, (2) evaluate a new test measuring absorbance of solubilized formazan dyes, and (3) test the correlation between these tests for cytotoxicity. Balb/c 3T3 cells were plated in 24-well culture trays at 25,000 cells/cm2 around ten types of dental casting alloys (six samples/alloy) and incubated for 72 h. Cells were histochemically stained with MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide)/succinate for 2 h, then fixed, washed, and dried. Toxicity was measured by optical densitometer (OD) scanning, visual assessment, and 560-nm absorbance of DMSO-solubilized dyes. Measurements of rings of inhibition were not used, because they did not provide precise data, and correlated poorly with the other methods. The results were analyzed by ANOVA, Tukey intervals, and coefficients of variation (CV's). MTT required shorter incubation times for adequate staining, allowed for solubilization of the monolayers, and was less expensive than NBT (2,2'-di-p-nitro-phenyl-5,5'-diphenyl-3,3'-dimethoxy-[3,3'-dimethoxy-4,4 '-biphenylene] ditetrazolium chloride). Results showed that all three methods ranked alloy toxicities similarly (p = 0.05). The solubilization method was most discriminating due to lower CV's. Correlation between densitometer and solubilization methods was excellent (R2 = 0.96). Between-experiment CV's were generally less than 20%, and often less than 10%. Between-sample CV's were generally less than 20%.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

The effects of cleaning on the kinetics of in vitro metal release from dental casting alloys.

The kinetics of the release of elements from six dental casting alloys into cell-culture medium was assessed by means of atomic absorption spectroscopy. Alloys were evaluated in the polished and polished-cleaned conditions so that the effects of cleaning could be determined. Auger scanning microscopy was used for analysis of the surfaces of selected alloys before and after exposure to the cell-culture medium. Release patterns for each element were characterized by the shape of the dissolution vs. time curve, concentration of the element at 12 h as a percentage of the 72-hour concentration, and the relative slope of the curve from 48 to 72 h. Three patterns of release were observed for elements in these alloys. Type I patterns had logarithmic shapes with relatively large 12-hour concentrations and low 48-72-hour slopes. Type II patterns had logarithmic shapes but with moderate 12-hour concentrations and 48-72-hour slopes. Type III patterns were polynomial in shape, had relatively low 12-hour concentrations, and had large 48-72-hour slopes. Cleaning did not change the pattern of release but did generally significantly decrease the quantities of elements released (p = 0.05). The type of dissolution vs. time curve appeared to be dependent upon the element and the composition of the alloy. When cleaning reduced dissolution, surface analyses showed that the cleaning process increased the abundance of elements such as Au and Pd and reduced the abundance of Ag and Cu. Elements which were released from the alloys were more abundant on the surface than in the bulk in both polished and polished-cleaned conditions.(ABSTRACT TRUNCATED AT 250 WORDS)

Cadmium↗

Cytotoxicity of a BIS-GMA dental composite before and after leaching in organic solvents.

Cell culture techniques were used to determine the source of cytotoxic agents in a commercial BIS-GMA composite. The material was polymerized according to the manufacturer's directions and leachable components were removed by room temperature extraction in ethanol, chloroform, or toluene. The leachable components in the extracts were identified using infrared spectrographic analysis. Thin layer chromatographic analysis was used to determine the number of constituents. These constituents were separated by gas chromatography and then identified by mass spectrographic analysis. Succinic dehydrogenase activity and radioactive labeling with tritiated leucine were used to evaluate cell metabolism and protein synthesis, respectively. The infrared analysis of the extracts showed that the primary component was unreacted BIS-GMA. Trace amounts of 2-hydroxy-4-methoxy-benzophenone, a light stabilizer, as well as a phenyl ester of benzoic acid which was probably degraded from BIS-GMA, were detected by the mass spectrographic method. The removal of leachable components caused a 90% decrease in toxicity compared to the nonextracted BIS-GMA samples. The extracted BIS-GMA samples showed no cellular response compared to the Teflon negative control.

Animals↗