Search PubMed⌕ Search

Biomedical subjects

R Fries

Publications and source records attributed to R Fries.

At least 55 records · Page 3Linked to original sources

High-resolution, human-bovine comparative mapping based on a closed YAC contig spanning the bovine mh locus.

A closed YAC contig spanning the mh locus was assembled by STS content mapping with seven microsatellite markers, eight genes or EST, and nine STS corresponding to YAC ends. The contig comprises 27 YACs, has an average depth of 4.3 YACs, and spans an estimated 1.2 Mb. A linkage map was constructed based on five of the microsatellite markers anchored to the contig and shown to span 7 cM, yielding a ratio of 160 kb/1 cM for the corresponding chromosome region. Comparative mapping data indicate that the constructed contig spans an evolutionary breakpoint connecting two chromosome segments that are syntenic but not adjacent in the human. Consolidation of human gene order by means of whole genome radiation hybrids and its comparison with the bovine order as inferred from the contig confirm conservation of gene order within segments.

Animals↗

Construction and characterization of a porcine P1-derived artificial chromosome (PAC) library covering 3.2 genome equivalents and cytogenetical assignment of six type I and type II loci.

A porcine P1-derived artificial chromosome (PAC) library of a male German Landrace pig was constructed in pCYPAC2. In total 90,240 clones were generated and individually transferred into microtiter plates. An average insert size of 119.1 kb was determined by analyzing 150 randomly selected PAC clones by pulsed field electrophoresis, yielding approximately 3.2 genome equivalents. The stability of nine clones was followed through 110 generations showing no reduction of the insert size. The probability of identifying a specific chromosomal region within the library was tested by screening for the presence of seven type I and five type II loci. The analysis showed that most loci (10/12) were present in the library at least twice. To determine the percentage of chimerism, six clones were analyzed by fluorescence in situ hybridization (FISH) on metaphase chromosomes. We assign one type I locus (Triadin) and three type II loci (SW855, S0300, SW1129).

Animals↗

A 5x genome coverage bovine BAC library: production, characterization, and distribution.

A bovine large-insert DNA library has been constructed in a Bacterial Artificial Chromosome (BAC) vector. The source DNA was derived from lymphocytes of a Jersey male. High-molecular-weight DNA fragments were produced by treatment with EcoRI/EcoRI methylase and cloned into the EcoRI site of pBACe3.6. In total, 157,240 individual BACs have been picked into 384-well plates. Approximately 190 randomly chosen clones have been characterized by Pulsed Field Gel Electrophoresis (PFGE) and have an average insert size of 105 kb, suggesting library coverage representing 5-6 genome equivalents. The frequency of clones without inserts is 4%. The chromosomal location of 51 BACs was studied by FISH; 3 showed more than one signal, indicating a chimerism frequency of roughly 6%. Approximately 50% of the clones in the library contain Simple Repeat Sequences (microsatellites), and 4% of the clones contain centromeric repeats. Insert stability was assessed by restriction digestion of DNA prepared from 20 clones after serial culture for one and three nights. Only one clone showed any evidence of an altered restriction pattern. Clones from 360 x 384-well plates (138,240 colonies) were gridded onto high-density membranes, and PCR superpools were produced from the same set of clones. Both membranes and superpools are available from the RZPD, Berlin (http://www.rzpd.de). PCR 4-D superpools have been prepared from an additional 23,000 clones. The library has been screened for a total of 24 single-copy sequences; positive clones have been obtained in all cases.

Animals↗

Water and air in two poultry processing plants' chilling facilities--a bacteriological survey.

1. Water, aerosols and air in chilling facilities in 2 poultry abattoirs were bacteriologically examined. The different types of samples displayed a variety of bacterial loads and genera. 2. The aerobic plate count in water from spray nozzles was about log10 2 to 3 in both plants. Flavobacterium, Alcaligenes, Acinetobacter and Pseudomonadaceae were predominant in these samples. 3. The microbial load in air of the 2 plants was quite different, consisting mainly of Micrococcaceae and Gram-positive irregular rods. 4. The aerobic plate count in aerosols was extremely high. The flora was the same as was found in the spray nozzles samples, plus Enterobacteriaceae, Micrococcaceae and streptococci, which presumably came from the air in the system. Cross-contamination may well occur in evaporative chilling.

Abattoirs↗

Clinical significance of sleep-related breathing disorders in patients with implantable cardioverter defibrillators.

The prevalence and clinical significance of sleep-related breathing disorders (SRBDs) in patients with cardiac disease and a history of life-threatening ventricular tachyarrhythmias is unclear. Forty consecutive recipients of implantable cardioverter defibrillators (ICDs) with cardiac disease and a documented history of spontaneous, life-threatening, ventricular tachyarrhythmias underwent full night polysomnography. SRBDs were diagnosed if the apnea/hypopnea index was > 10. SRBD were diagnosed in 16 of 40 patients (40%): central sleep apnea (CSA) was present in 9 of these 16 patients (56%), 8 of whom had associated Cheyne-Stoke respiration. Seven of the 16 patients with SRBD (44%) had obstructive sleep apnea (OSA). Patients with and without SRBDs were comparable with respect to left ventricular ejection fraction, NYHA classification, underlying heart disease, ICD indications, and concomitant antiarrhythmic drug and beta-blocker therapy. Patients were followed prospectively for 2 years. ICD-treated ventricular tachyarrhythmias occurred in 10 of 24 patients (42%) without SRBD, in 4 of 9 patients (44%) with CSA, and in 3 of 7 patients (44%) with OSA (NS). The numbers and circadian distributions of episodes recorded during follow-up in patients without SRBD versus with CSA or OSA were not significantly different (14 +/- 25, median = 4 vs 4 +/- 5, median = 2.5 vs 15 +/- 15, median = 7, respectively). The 2-year mortality, which was entirely attributable to nonsudden cardiac events, was highest in patients with CSA (4/9 [44%], vs 0/7 [0%] with OSA, vs 3/24 patients (12.5%) without SRBD; P < 0.05).

Aged↗

Transvenous atrial cardioversion threshold in patients with implantable cardioverter defibrillator: influence of active pectoral can.

Recent studies have shown that transvenous atrial cardioversion is feasible with lead configurations primarily designed for implantable cardioverter defibrillators (ICD). The purpose of this study was to examine the influence of an active pectoral ICD can on the atrial cardioversion threshold (ADFT). Forty consecutive patients received a transvenous single lead system (Endotak DSP 0125, CPI, St. Paul, MN, USA) in combination with a left subpectoral ICD (Ventak Mini, CPI) for treatment of malignant ventricular tachyarrhythmias. Patients were randomized into two groups: 21 received a Hot Can 1743 and 19 patients a Cold Can 1741. Step-down testing of the ventricular defibrillation threshold (VDFT) was performed intraoperatively and evaluation of the ADFT for induced atrial fibrillation (AF) at predischarge. After testing, each patient received a 2-J shock and was asked to quantify discomfort on a numerical scale ranging from 0 to 10. Both groups were comparable with regard to all clinical parameters studied. The mean VDFT in patients with a Hot Can device was significantly lower than in patients with a Cold Can (7.5 +/- 2.3 J vs 9.8 +/- 3.8 J; P < 0.03). The mean ADFT in the Hot Can group tended to be lower than in the group with Cold Cans (3.4 +/- 1.4 J vs 4.5 +/- 2.4 J; P = 0.07), and the proportion of patients in whom atrial cardioversion was accomplished at low energies (< or = 3 J) was higher in patients with active compared with patients with inactive pulse generators (57% vs 26%; P < 0.04). The mean discomfort reported after delivery of a 2-J shock was comparable in both groups (Hot Can 5.2 +/- 1.9; Cold Can: 5.3 +/- 2.1; P = NS). We conclude that the inclusion of an active left subpectoral can in the defibrillation vector of a ventricular ICD seems to reduce the energy requirements for atrial cardioversion without increasing the discomfort caused by low energy shocks.

Atrial Fibrillation↗

[Associations between farm characteristics in fattening pigs and occurrence of lesions at meat inspection].

A revised inspection system for fattening pigs in the EU has been proposed emphasizing the need for a more detailed documentation of the fattening process. It is supposed that the availability of such information enables a discrimination of conspicuous and non-conspicuous lots of fattening pigs delivered to the abattoir allowing for a modified, only visual inspection of non-conspicuous lots. This proposal motivated a study performed in 1996 on about 22,000 pigs, searching, among other things, for first hints on associations between management/farm conditions for fattening pigs and lesions found at meat inspection, which can be used for discrimination. Taking the two lesions 'pneumonia' and 'callous affections of the legs' as examples this contribution demonstrates the use of regression trees to visualize association structures and to develop hypotheses on relations between lesions and farm characteristics. An association of 'callous affections of the legs' with flooring systems is clearly shown in the generated tree. The occurrence of 'pneumonia' seems to be associated with the application of disinfection measures in this data set. However, this result should be interpreted with caution as some problems for data analysis arise because of the low number of farms in this study in relation to the high number and complexity of farm characteristics considered. A further problem is the high variability of daily deliveries within farms that cannot be explained referring to farm characteristics common to all deliveries. As a conclusion data from this study have been useful to develop hypotheses on associations between farm characteristics and lesions at meat inspection. However, there is need for further, more specific studies before such associations can be utilized to discriminate between conspicuous and non-conspicuous lots of fattening pigs.

Animal Husbandry↗

Influence of beta-blockers on the frequency of arrhythmia recurrences in patients with implantable cardioverter-defibrillator: an intraindividual comparison.

We studied retrospectively 60 consecutive recipients of an implantable cardioverter-defibrillator and identified 16 patients who were temporarily on and off beta-blockers (further medication unchanged). An intraindividual analysis revealed that 56% of the patients experienced more arrhythmic episodes during follow-up off beta-blockers compared to 44% while being on beta-blockers. Also, the mean episode frequency during follow-up time on and off beta-blockers was comparable (0.4+/-0.6 vs. 0.5+/-0.5, ns).

Adrenergic beta-Antagonists↗

[Clinical significance of sleep apnea disorders after implantation of a cardioverter-defibrillator in patients with cardiac disease and sustained ventricular tachyarrhythmia].

The purpose of our study was to determine the prevalence of sleep related breathing disorders (SRBD) in patients with an implantable cardioverter-defibrillator (ICD) and to evaluate prospectively the possible influence of SRBD on arrhythmia recurrence and circadian arrhythmia variation as well as on cardiac mortality during long-term follow-up. Forty consecutive ICD recipients with cardiac disease and a documented history of spontaneous, life-threatening, ventricular tachyarrhythmias underwent full-night polysomnography and were followed for 2 years. In 16 of 40 patients (40%), SRBD were diagnosed (Apnea/Hypopnea Index (AHI) > 10); in 9 of these 16 patients (56%) central sleep apneas (CSA) occurred (in 8 of these 9 patients in combination with Cheyne-Stokes respiration). Seven of the 16 patients with SRBD (44%) revealed obstructive sleep apneas (OSA). AHI was 32 +/- 15 (12-60) in patients with CSA and 32 +/- 27 (11-86) in patients with OSA. Patients with and without SRBD were comparable concerning left ventricular ejection fraction, NYHA classification, cardiac disease, ICD indication, and concomitant medication. ICD registered ventricular tachyarrhythmias occurred in 10 of 24 patients (42%) without SRBD, in 4 of 9 patients (44%) with CSA, and in 3 of 7 patients (44%) with OSA. The numbers and circadian variation of episodes registered during follow-up in patients without SRBD, with OSA or CSA were comparable (14 +/- 25, median 4 vs 15 +/- 15, median 7 vs 4 +/- 5, median 2.5). The 2-year cardiac mortality was highest in patients with CSA (4/9 (44%) vs. 0/7 patients (0%) with OSA vs 3/24 patients (12.5%) without SRBD. Thus, the prevalence of SRBD in patients with chronic heart failure and a history of malignant ventricular tachyarrhythmias is high (40%) and the occurrence of CSA seems to be predictive for cardiac mortality in these patients. An influence of moderate SRBD on arrhythmia recurrence and circadian variation of spontaneous sustained tachyarrhythmic events could not be demonstrated.

Aged↗

[Reproducibility of the effectiveness of defibrillation for terminating induced ventricular fibrillation using intraoperatively measured defibrillation threshold energy in patients with implanted cardioverter-defibrillator].

The aim of the present study was to assess the long-term reproducibility of the defibrillation efficacy of energies set at the intraoperatively measured defibrillation threshold using a modified testing protocol. Between December 1993 and January 1996, 83 patients receiving an implantable cardioverter-defibrillator (ICD) in combination with a non-thoracotomy lead system and having an intraoperatively measured defibrillation threshold (DFT) < or = 15 J were enrolled in a substudy of a prospective, randomized multicenter trial ("Low Energy Endotak Trial" (LEET)). Step-down DFT testing was performed intraoperatively (15, 10, 8, 5 J). It was mandatory to reproduce a successful conversion of ventricular fibrillation at the DFT energy during implantation (DFT+). At the end of implantation, at predischarge, and after one year, assessment of the defibrillation efficacy of DFT+ energy was repeated (first shock: DFT+, second shock: 2 x DFT+). Mean DFT+ at implant was 9.6 + 3.3 J. Immediately after implantation, successful conversion of induced ventricular fibrillation was achieved in 70/79 (89%) patients using DFT+ energies. In 7/8 (89%) patients only the second shock set at 2 x DFT+ and in one patient only the third shock set at maximum energy (34 J) was successful. At predischarge, defibrillation efficacy of DFT+ was reproducible in 61/77 (79%) patients. The remaining 16 patients were successfully converted using a second shock set at 2 x DFT+. One year after implantation, conversion of ventricular fibrillation was achieved at energies set at DFT+ in 52/62 (84%) patients and in the remaining 10 patients at energies set at 2 x DFT+. A total of 183/218 (84%) episodes of induced ventricular fibrillation were terminated successfully using DFT+ energies. There was no correlation between the intraoperatively determined DFT+ or the underlying cardiac disease and the defibrillation efficacy. These results demonstrate that the defibrillation efficacy for termination of induced ventricular fibrillation using DFT+ energies is reproducible at implantation, at predischarge, and one year after ICD insertion. Energies set at twice DFT+ seems to allow for reliable defibrillation within the first year after ICD implantation.

Adult↗

Valve-preserving replacement of the ascending aorta: remodeling versus reimplantation.

OBJECTIVE: Aortic valve regurgitation in combination with dilatation of the ascending aorta and root requires a combined procedure to restore valve function and eliminate pathologic dilatation of the proximal aorta. Two techniques have been proposed for this purpose; the aortic root may be either remodeled with an especially configured vascular graft or replaced with reimplantation of the aortic valve within the graft. We have used both techniques depending on the individual pathologic condition of the aortic root. METHODS: Of 107 patients undergoing operation for proximal aortic disease between October 1995 and November 1997, 40 patients had morphologically intact aortic valve leaflets in conjunction with dilatation of the aortic root. Of these, 15 patients underwent an operation as a surgical emergency for acute aortic dissection type A. In 29 instances, root remodeling in conjunction with ascending aortic replacement was performed; 11 patients underwent radical replacement of the proximal aorta with reimplantation of the aortic valve. Partial or total arch replacement was performed additionally in 27 of these patients. Other concomitant procedures were coronary artery bypass grafts (n = 11) and mitral reconstruction (n = 1). RESULTS: Two patients died after repair of acute aortic dissection, for a total operative mortality rate of 5%. No patient died after elective surgery. Aortic valve function could be effectively restored with both techniques. No patient underwent reoperation on the proximal aorta; freedom from aortic regurgitation of grade II or more at 1 year is 88% with both techniques. CONCLUSIONS: Depending on individual root pathologic condition, both the remodeling and the reimplantation techniques appeared to have their individual merits. Both result in adequate restoration of aortic valve function and elimination of pathologic aortic dilatation.

Adult↗

Construction and characterisation of a gridded chicken cosmid library with four-fold genomic coverage.

Gridded genomic libraries are crucial for the positional candidate gene approach. For this purpose we constructed a gridded genomic library from a female chicken using the vector sCos 1. About 110,000 cosmid clones were grown and replicated in 384-well plates. An average insert size of 39 kb was calculated from the analysis of 68 randomly selected clones. No chimerism could be observed from 31 in situ hybridisations. One replica of the library (number 125) has been transferred to the Resource Centre/Primary Database (RZPD) of the German Human Genome Project (DHGP). The whole library was gridded onto four nylon filters at high density for efficient identification of cosmid clones by colony hybridisation. Twenty-two probes were used for screening the library and each of them gave at least one positive signal. This result is in good agreement with a four-fold coverage of the genome as estimated from the insert length and number of recombinant clones. This library provides a powerful tool for rapid physical mapping and complex analysis of the chicken genome.

Animals↗