Search PubMed⌕ Search

Biomedical subjects

R Fischbach

Publications and source records attributed to R Fischbach.

At least 19 recordsLinked to original sources

[Whole-heart coronary MR angiography -- initial results].

PURPOSE: To evaluate a new coronary MR angiography technique covering the whole coronary artery tree in one data set acquisition. MATERIALS AND METHODS: Six healthy volunteers and 15 patients with known CAD were examined with a navigator gated and corrected (NAV) free-breathing 3D steady-state free precession sequence covering the whole heart (WH-MRA) (TR = 5.4, TE = 2.7, SENSE factor = 2, 160 slices, 0.75 mm reconstructed slice thickness, in-plane resolution = 0.99 x 0.99 mm(2), scan time 14 min [50 % NAV efficiency]) and a vessel targeted 3D SSFP MRA sequence (t-MRA) (TR = 5.6 ms, TE = 2.8 ms, 20 slices of 1.5 mm reconstructed slice thickness, in-plane resolution = 0.99 x 0.99 mm(2), scan time = 7 min [50 % NAV efficiency]). Subjective image quality (4-point scale) and objective image quality parameters including vessel sharpness, vessel diameter and CNR were calculated for WH-MRA and t-MRA. In patients, the accuracy for detection of stenosis larger than 50 % was compared to the accuracy of X-ray coronary angiography (XA), which was considered the standard. RESULTS: WH-MRA demonstrated good vessel visibility in healthy subjects (100 %) whereas vessel visibility in patients was limited (78 % in an 8 segment evaluation). Vessel sharpness was inferior to that of t-MRA in patients (37 vs. 42 %) but equal in healthy subjects (42 %). Vessel diameter did not differ significantly between WH-MRA and t-MRA. CNR was significantly reduced for WH-MRA (CNR 7.4 vs. 11.5). The diagnostic accuracy for the detection of CAD was comparable for both MRA approaches (85.5 vs. 86.2 %). CONCLUSION: WH-MRA allows good coronary artery visualization in healthy subjects and patients and provides a simplified scanning procedure and advantages in 3D post-processing. Regarding image parameters and the detection of CAD, the results are comparable to those acquired with t-MRA. The major disadvantage remains the high number of diagnostically insufficient images.

Adult↗

[Brachioradial pruritus: a rare, localized, neuropathic form of itching].

We report on a female patient with brachioradial pruritus, in whom the cause could be verified by purposeful diagnostics (e. g., MRI). The clinical symptoms with localized itching result from circumscribed nerve root compression and hyperexcitation of the nerve fibers. Under treatment with gabapentin, an anticonvulsant with a very good analgesic and good antipruritic effect, the itch ceased and the skin changes healed. This case shows that this special form of neuropathic itch requires targeted therapy, which apart from symptomatic treatment should primarily focus on remedying the cause, if feasible.

Amines↗

[Transarterial chemoembolization of liver metastases of colorectal carcinoma using degradable starch microspheres (Spherex): personal investigations and review of the literature].

Since two decades transarterial chemoembolization (TACE) of liver metastases has been investigated in numerous studies. However, no standardized therapeutic procedure exists so far. The present study retrospectively investigated survival, response and side effects after TACE of liver metastases in 21 patients with colorectal cancer and results are compared with previous literature. A total of 68 TACE procedures were performed. A suspension of degradable starch microspheres (DSM, Spherex) and Mitomycin C was applied selectively into hepatic arteries via a transfemoral approach. DSM effect a temporary arterial occlusion. Follow-up studies were performed by contrast enhanced spiral computed tomography (CT). The median survival was 13.8 months. Therapeutic response (according to WHO) was observed only in three patients. The progression free interval was 5.8 months. Patients developed a postembolization-syndrome (abdominal pain, fever, nausea) and increased transaminases in 27-43% of all interventions. A gastric ulcer occurred after four, cholecystitis after two TACE. As already shown in most previous studies, regardless of the used agents, also this investigation underlines the moderate therapeutic effect of TACE on colorectal liver metastases. So far, no significant survival benefit has been shown in the literature and the response rates are rather limited. In general, complications of TACE seem to be rare, but should not to be underestimated. Compared to TACE with long or permanent arterial occlusion, postembolization syndrome seems to be less pronounced using DSM. As TACE is rather a palliative therapeutic approach, DSM therefore might be more suited. Further studies on TACE of liver metastases should focus on to the patients' quality of life.

Absorbable Implants↗

[Automatic injectors in magnetic resonance imaging and computed tomography: pilot study on hygienic aspects].

PURPOSE: To evaluate hygienic conditions using automatic injectors in magnetic resonance imaging (MRI) and computed tomography (CT) during clinical routine. MATERIALS AND METHODS: The surfaces of medical devices (e. g., control console) and the palms of the technical and medical staff were microbiologically analyzed by taking imprints before and after hygienic education. In addition, the injector syringes for contrast medium (CM) and saline were checked for microbiological contamination following multiple (MRI: 14 h; CT 8 h) and single use. Furthermore, the potential of retrograde contamination from the patient along the tube was analyzed. RESULTS: A bacterial contamination with typical dermal bacteria was documented for the surfaces of the medical devices, the palms of the technical and medical staff, and the injection syringes following multiple use (MRI: 10/10 CM syringes, 6/10 saline syringes; CT: 8/10 CM syringes, 5/10 saline syringes). Correct hand disinfection in combination with single use of syringes avoided bacterial colonization. Retrograde bacterial contamination from the patient was not observed. CONCLUSION: Regular hygienic teaching sessions for technical and medical staff in MRI and CT departments using automatic injectors should be mandatory. Furthermore, the multiple use of syringes should be avoided until investigations addressing the potential of bacterial contamination are performed.

Contrast Media↗

[Aneurysm of the subclavian artery after operatively corrected coarctation of the aorta: 20 years of follow-up and review of the current literature].

We report of long-term follow-up of a combined fusiform aneurysm of the right subclavian artery extending to the thyreocervical trunk (3.2 x 2.8 x 2.2 cm (width x height x depth)) in a 33-year old patient. As a newborn, the clinical diagnosis of an aortic isthmus stenosis was made without need for intervention at this stage. Further development of the child remained unremarkable until the age of eleven years when he experienced dizziness after sporting activities. Due to clinically proven progress, cardiac catheterization was performed and confirmed the initial diagnosis of a juxtaductale stenosis of the aortic isthmus, which was operated thereafter with an end-to-end anastomosis. Furthermore, an aneurysm of the right subclavian artery was revealed. Since then, non-invasive routine follow-up showed no significant worsening of this aneurysm, which extends to the thyreocervical trunk. The patient has been event free and completely asymptomatic. This case report illustrates the more than twenty years of follow-up of an asymptomatic combined fusiform aneurysm of the subclavian artery and thyreocervical trunk and provides a review of the literature on this topic.

Adolescent↗

Assessment of coronary arterial stents by multislice-CT angiography.

PURPOSE: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. MATERIAL AND METHODS: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (> or =50%). RESULTS: Image quality was fair to good on average (score 2.64 +/- 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessible due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. CONCLUSION: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g., 16-slice scanners) and more sophisticated reconstruction algorithms, further improvements may be expected.

Aged↗

Pharmacokinetics of intra-arterial mitomycin C in the chemoembolization treatment of liver metastases with polyvinylalcohol or degradable starch microspheres.

OBJECTIVES: In cancer treatment, arterial blood flow reduction by embolization combined with intra-arterial chemotherapy may be advantageous by achieving high and prolonged drug concentrations in the tumor, and lower systemic drug exposure. The pharmacokinetics of intra-arterial mitomycin C (MMC) was investigated in patients with liver metastases undergoing chemoembolization treatment. METHODS: The chemoembolization treatment consisted of the use of polyvinylalcohol microspheres (ITC-Contour, diameter 150-250 micro m, irreversible vessel occlusion, 20 mg MMC, 15 patients) followed by sealing of the supplying artery with Ethibloc. Alternatively, starch microspheres (Spherex, diameter 45 micro m, biologically degradable, 10 ml of suspension containing 60 mg starch/ml, 20 mg MMC in 7 patients, 15 mg/m2 body surface in 3 patients) were used. MMC was infused over 6 min into the artery supplying the tumor. Serum MMC concentrations were determined from peripheral venous blood samples [protein precipitation with acetonitrile, reverse-phase HPLC with ultraviolet detection (C18 column, elution with 0.01 M, pH 6.5 phosphate buffer/methanol, v/v 70:30, 365 nm)]. The pharmacokinetic parameters were computed assuming an open two-compartment model and linear kinetics. RESULTS: The disposition parameters for MMC in patients treated with polyvinylalcohol microspheres were comparable to data from the literature (C(max)=913+/-98 ng/ml, T(max)=7.7+/-0.3 min, V(c)=0.27+/-0.03 l/kg, V(ss)=0.59+/-0.07 l/kg, Cl=757+/-67 ml/min, T(1/2 alpha)=5.8+/-0.8 min, T(1/2 beta)=50.4+/-4.1 min). There was no significant difference in the disposition parameters for MMC between patients treated with polyvinylalcohol microspheres and those treated with starch microspheres ( P>0.05). In particular, there was no significant difference in the standardized AUC between the groups; this implies that the systemic toxicity of MMC is comparable when polyvinylalcohol microspheres and ethibloc (AUC 1472+/-123 microg min/l per 1 mg MMC) or starch microspheres (AUC: 1448+/-172 microg min/l per 1 mg MMC) are used. CONCLUSION: The AUC values found in this study do not indicate a reduction in the systemic toxicity of MMC if applied intra-arterially in combination with embolizing microspheres, when compared to the AUC values in the literature for intra-arterial application without embolization, or intravenous MMC application. The amount of starch microspheres may have been too small to cause marked effects. On the other hand, there is a very wide range of AUC values reported in the literature for different application modes, and the use of such historical controls is not adequate for detecting more subtle advantages of the chemoembolization procedure, which may, however, exist.

Aged↗

Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT.

High reproducibility is a key requirement for coronary calcium scoring in follow-up examinations. We investigated the inter-examination reproducibility of calcium scoring with retrospectively ECG-gated multisection spiral CT (MSCT). Fifty patients were examined twice with MSCT. Slices were reconstructed with retrospective ECG gating in the diastolic phase with 3-mm slice width and up to 125-ms temporal resolution. We calculated the Agatston score, calcium volume with and without isotropic interpolation, and calcium mass, and derived the mean and median variability. We investigated the change of variability with use of 3-mm non-overlapping and overlapping increments (2, 1.5, 1 mm). Use of overlapping increment results in considerably reduced interscan variability. We observed a minimum mean variability of 12% and a minimum median variability of 9% for the Agatston score. For volume and mass quantification we obtained a minimum mean variability of 7.5% and a minimum median variability of 5%. Multisection spiral CT enables coronary calcium quantification with high reproducibility in follow-up examinations mainly founded on image data with reduced partial-volume errors due to overlapping increment.

Adult↗

[Pulmonary aspergillosis as initial manifestation of septic granulomatosis (chronic granulomatous disease, CGD) in a premature monozygotic female twin and FDG-PET diagnosis of spread of the disease].

PURPOSE: To present the unusual case of chronic granulomatous disease (CGD) manifestating as pulmonal aspergillosis in female enzygotic twins during the neonatal period. To demonstrate and to discuss the complex diagnosis and the diagnostic value of FDG-PET in monitoring the spread and activity of the disease. PATIENTS: Plain chest x-ray and CT of the lung showed multiple, mostly round lesions in one of the former preterm twins at the age of 8 weeks. The girl with known ASD II was then suffering from dyspnoea and recurrent pulmonary infections. Because of the imaging findings invasive pulmonary aspergillosis due to an underlying immunodeficiency was suspected. RESULTS: Aspergillosis was confirmed histologically and microbiologically by specimens taken from an open lung biopsy. Because of coexisting granulocytic dysfunction the diagnosis of CGD was made. This diagnosis was equally confirmed by noninvasive methods in the asymptomatic sister. FDG-PET did not show any evidence of extra-pulmonary spread of disease. CONCLUSION: CGD can present as isolated pulmonal aspergillosis even in the neonatal period when an immunodeficiency is discussed. In enzygotic twins screening of the asymptomatic twin is mandatory. FDG-PET is a useful tool in screening for spread of the disease and in evaluating disease activity.

Age Factors↗

[Diagnosis of intra-articular fracture of the head of the tibia. A prospective comparative study].

Complete visualization of the joint surface is essential for correct assessment of tibial head fractures. Conventional tomography, computed tomography (CT), and magnetic resonance imaging (MRI) are compared in this prospective study. We examined 27 patients (19 suffering from B fractures and 8 from C fractures) from 1 January 1995 to 11 November 1998. Conventional tomography underestimated the fractures in 3 of the 19 cases of B fractures. Computed tomography underestimated two of these cases. MRI could not exactly depict the essential structures in three of the eight cases of C fractures because of edema and effusions. MRI identified complete cruciate ligament rupture in 6 of the 27 cases (18%) and 10 meniscal ruptures in 9 cases (33%: 6 medial meniscus, 4 lateral meniscus). Complete ruptures of the lateral collateral ligament were detected in five cases and medial collateral ligament ruptures in two cases. According to this, 63% of the patients suffered from relevant accompanying soft tissue injuries. The rate of soft tissue injuries increased up to 92% including the partial collateral ligament ruptures. Local hospital conditions permitting, X-ray-loaded conventional tomography should no longer be used in tibial head fractures. X-ray-free MRI is most efficient in cases of B fractures, which can in most cases be treated with a minimum of invasive techniques. Computed tomography is to be used in cases of C fractures that are regularly managed by open surgery accompanied by direct visualization of the inside of the knee joint.

Adult↗

[Multi-slice spiral CT of the abdomen in oncological patients: influence of table support and detector configuration on image quality and radiation exposure].

PURPOSE: To evaluate the image quality and radiation exposure of different spiral CT scanning parameters for routine staging examination of the abdomen in oncologic patients using a multi-slice CT scanner. METHODS/MATERIALS: Examination of 40 patients in 4 groups on a multi-slice CT scanner (Somatom VolumeZoom, Siemens AG, Forchheim). Functional detector width (4 x 2.5, 4 x 5 mm) and pitch (table feed in relation to collimated slice width) were varied (3 and 5). Tube voltage (120 kV), effective tube current (160 mAs), slice-thickness (6 mm), increment (4 mm), kernel (B 30), and contrast injection parameters were kept constant. Axial images were assessed by three radiologists regarding delineation of anatomic structures, artifacts, and overall image quality. RESULTS: Significantly reduced image quality especially due to artifacts was observed using a 5 mm detector configuration with a pitch of 5 (scan time 9 sec). Image quality was rated best for a 2.5 mm detector configuration with a pitch of 3 and a scan time of 28 sec. The effective dose was independent of the pitch. However, the mean effective dose was 9% higher using the smaller detector configuration (9.9 mSv vs 10.9 mSv). CONCLUSIONS: For routine staging CT of the abdomen use of a 4 x 2.5 mm detector configuration with a pitch between 3 and 5 is recommended. A 4 x 5 mm detector configuration using overlapping data acquisition can also be recommended, but additional thin slice reformations are not possible.

Abdominal Neoplasms↗

[Local therapy of liver metastases of colorectal carcinomas. Laser therapy vs. direct current treatment in the rat model].

PURPOSE: Evaluation of the efficacy of direct current and laser therapy in the treatment of colorectal liver metastases in a rat model. MATERIALS AND METHODS: Liver metastases in 49 rats were induced by subcapsular injection of cells of a colorectal tumor cell line. 3 weeks after inoculation 41 tumors were treated by laser and 56 tumors by direct current therapy. 17 tumors served as a control in the direct current group, 12 in the laser therapy group. The inoculation rate and the tumor size 3 and 5 weeks after therapy were determined by MRI. RESULTS: The MR-tomographically determined inoculation rate was 133 tumors after 151 tumor cell injections (88%). Three and five weeks after laser therapy, tumor growth rates of 15% and 18% were documented (maximum tumor diameter). This represented a significant reduction in growth (p < or = 0.01 and p < or = 0.001) compared to the control group (growth rate 230% and 280%). In the direct current therapy group, growth rates were 40% after 3 and 60% after 5 weeks. Compared to the control group (210% and 290%), this also represented a significant reduction (p < or = 0.001). CONCLUSIONS: This animal study is the first to demonstrate an antitumor effect of direct-current therapy on liver metastases of colorectal cancer in rats. Nevertheless, the laser therapy proved to be more effective.

Animals↗

Colorectal polyps: Detection with multi-slice CT colonography.

PURPOSE: To compare the performance of virtual and conventional colonoscopy for the detection of colorectal polyps using a multislice spiral CT scanner (MSCT). MATERIALS AND METHODS: 48 patients (20 women, 28 men, mean age 61.5 years) with clinical indication for conventional colonoscopy were prospectively studied using a MSCT (Somatom Volume Zoom, Siemens, Forchheim). Examination was performed after standard oral preparation for colonoscopy and colonic distension with room air and i. v. butylscopolamin. Images were obtained in prone and supine position using a detector configuration of 4 x 1 mm, a table feed of 5 mm/rotation at 140 mAs and 120 kV. Slice thickness and reconstruction increment were 3 and 1.5 mm, respectively. CT data were assessed by two blinded radiologists on a Vitrea workstation (Vital Images, USA) using a software with multiplanar and volume-rendering capabilities. RESULTS: 33 patients had normal findings on conventional colonoscopy. In 15 patients a total of 30 polyps and one carcinoma with stenosis were identified. MSCT-colonography identified the carcinoma and 23 polyps (77 %). 3 of 3 polyps were 10 mm or more (100 %), 6 of 7 were 5.1 to 9.9 mm (86 %) and 14 of 20 were 5 mm or smaller (70 %). There were 13 false positive findings for polyps (10 lesions < 6 mm in 5 patients) and no false positive finding of carcinoma. CONCLUSIONS: MSCT colonography allows accurate detection of polyps larger than 10 mm. Compared to published results of single-slice CT, multislice CT colonography increases the rate of detection of small colorectal polyps in particular. However, false positive results still remain a problem.

Colonic Diseases↗