Search PubMed⌕ Search

Biomedical subjects

R Felix

Publications and source records attributed to R Felix.

At least 73 records · Page 4Linked to original sources

[Characterization of hepatic tumors with contrast-enhanced ultrasound and digital grey-scale analysis].

PURPOSE: The characterization of different liver tumors is of therapeutic and prognostic relevance and has been the purpose of several studies. Although ultrasound offers the opportunity to detect hepatic tumors without ionizing radiation, its previous techniques did not lead toward a definitive differentiation of different tumor entities. The purpose of this study was the clinical evaluation of contrast enhanced ultrasound followed by quantitative digital analysis in patients with focal hepatic tumors. MATERIALS AND METHODS: In a prospective study, 50 patients (18 females, 32 males, age 28 to 83 years, mean age 59.4 years) with liver tumors previously detected by CT (n = 47) or MRI (n = 3) were examined by ultrasound of the upper abdomen using conventional technique and phase inversion technique after intravenous application of sulfur-based contrast enhancer SonoVue. At scheduled intervals after application of the contrast enhancer, a digital image was stored and the characteristic signal course of each lesion determined semiquantitatively. The gold standard was either resection (n = 17), percutaneous needle biopsy (n = 19) or the clinical course (n = 14). RESULTS: While the percentage of tumors correctly characterized by CT/MRI amounted to 78 %, the percentage increased from 60 % using conventional ultrasound to 86 % using contrast enhanced ultrasound including grey-scale analysis. Typical graphs were achieved for different tumor entities on digital grey-scale analysis. The optimal intervals for the differentiation of particular entities were 20 and 100 seconds after injection. CONCLUSION: Quantification of contrast enhanced ultrasound is an addition to the previous diagnostic procedure in hepatic tumors. It offers the possibility of an investigator-independent characterization of lesions and should be evaluated in further studies.

Adenoma, Liver Cell↗

[Clinical use of digital retrospective image fusion of CT, MRI, FDG-PET and SPECT -- fields of indications and results].

PURPOSE: To evaluate the feasibility and the clinical benefits of retrospective digital image fusion (PET, SPECT, CT and MRI). MATERIALS AND METHODS: In a prospective study, a total of 273 image fusions were performed and evaluated. The underlying image acquisitions (CT, MRI, SPECT and PET) were performed in a way appropriate for the respective clinical question and anatomical region. Image fusion was executed with a software program developed during this study. The results of the image fusion procedure were evaluated in terms of technical feasibility, clinical objective, and therapeutic impact. RESULTS: The most frequent combinations of modalities were CT/PET (n = 156) and MRI/PET (n = 59), followed by MRI/SPECT (n = 28), CT/SPECT (n = 22) and CT/MRI (n = 8). The clinical questions included following regions (more than one region per case possible): neurocranium (n = 42), neck (n = 13), lung and mediastinum (n = 24), abdomen (n = 181), and pelvis (n = 65). In 92.6 % of all cases (n = 253), image fusion was technically successful. Image fusion was able to improve sensitivity and specificity of the single modality, or to add important diagnostic information. Image fusion was problematic in cases of different body positions between the two imaging modalities or different positions of mobile organs. In 37.9 % of the cases, image fusion added clinically relevant information compared to the single modality. CONCLUSION: For clinical questions concerning liver, pancreas, rectum, neck, or neurocranium, image fusion is a reliable method suitable for routine clinical application. Organ motion still limits its feasibility and routine use in other areas (e. g., thorax).

Adolescent↗

[Value of electron beam tomography (EBT)].

Electron beam tomography (EBT) has been scientifically evaluated to a much lesser degree for non-cardiac indications than for cardiac purposes. Therefore, four groups of investigators in Berlin (2), Mannheim and Munchen, which were supported by the Deutsche Forschungsgemeinschaft (DFG), included applications outside the heart in their evaluation of EBT technology. EBT has proven useful to look for pulmonary embolism and to assess other vessels (aorta, aortic branches, and intracranial arteries). Imaging of the lung parenchyma benefits from its intrinsic high contrast and from the fast data acquisition of EBT. Limited photon efficiency, higher radiation exposure, increased noise levels and other artifacts, however, markedly reduce the value of EBT for imaging of low contrast objects compared to conventional spiral CT and multislice CT (MSCT), compromising, in particular, the morphologic depiction of parenchymal abdominal organs and the brain. Consequently, scientific studies to further evaluate EBT for scanning of the brain and parenchymal abdominal organs were not pursued. Radiation exposure for non-cardiac EBT studies is up to three times higher than that for respective spiral CT studies, and in children EBT can only be advocated in select cases. Radiation exposure for the various prospectively triggered cardiac examination protocols of EBT is lower than that for conventional coronary angiography. Radiation exposure in cardiac multislice CT exceeds severalfold that of EBT, but the dose efficiency of EBT and MSCT are similar due to higher spatial resolution and less image noise of MSCT. In addition, modifications of MSCT (ECG pulsing) can further reduce radiation exposure to the level of EBT. Technical improvements of the EBT successor scanner "e-Speed" enable faster data acquisition at higher spatial resolution. Within comparative studies, the "e-Speed" will have to prove its value and competitiveness, particularly in comparison with multislice CT. After profound scientific assessment in a multicenter evaluation supported by the Deutsche Forschungsgemeinschaft (DFG) and regardless of the specific suitability of electron beam tomography for various cardiac and some non-cardiac indications, the investigators unanimously find the electron beam tomograph Evolution C150 XP not suitable as a whole body CT scanner.

Age Factors↗

[Digital knowledge in the coat pocket -- hand-held personal digital assistants in radiology].

The personal digital assistant (PDA) enables the independent access to large data in a pocket-sized format. The applications for hand-held computers are growing steadily and can support almost any kind of problem. An overview of the available hardware and software is provided and evaluated. Furthermore, the use of the PDA in the clinical daily routine is described. In view of the numerous software programs available in radiology, the range of software solutions for radiologists is presented. Despite the high acquisition cost, the PDA has already become the digital assistant for the radiologist. After a short time of getting used to the PDA, nobody wants to miss it at work or at home. New technical features and available software programs will continuously increase the integration of the PDA into the medical workflow in the near future.

Computers↗

[Diagnostic value of electron-beam computed tomography (EBT). I. Cardiac applications].

Electron beam tomography (EBT) directly competes with other non-invasive imaging modalities, such as multislice computed tomography, magnetic resonance imaging, and echocardiography, in the diagnostic assessment of cardiac diseases. EBT is the gold standard for the detection and quantification of coronary calcium as a preclinical sign of coronary artery disease (CAD). Its standardized examination protocols and the broad experience with this method favor EBT. First results with multislice CT indicate that this new technology may be equivalent to EBT for coronary calcium studies. The principal value of CT-based coronary calcium measurements continues to be an issue of controversy amongst radiologists and cardiologists due to lack of prospective randomized trials. Coronary angiography with EBT is characterized by a high negative predictive value and, in addition, may be indicated in some patients with manifest CAD. It remains to be shown whether coronary angiography with multislice CT is reliable and accurate enough to be introduced into the routine work-up, to replace some of the many strictly diagnostic coronary catheterizations in Germany and elsewhere. Assessment of coronary stent patency with EBT is associated with several problems and in our opinion cannot be advocated as a routine procedure. EBT may be recommended for the evaluation of coronary bypasses to look for bypass occlusions and significant stenoses, which, however, can be equally well achieved with multislice CT. Quantification of myocardial perfusion with EBT could not replace MRI or other modalities in this field. EBT has proven to be accurate, reliable and in some instances equivalent to MRI, which is the gold standard for the quantitative and qualitative evaluation of cardiac function. Some disadvantages, not the least of which is the limited distribution of electron beam scanners, favor MRI for functional assessment of the heart.

Adult↗

Whole-body hyperthermia in the scope of von Ardenne's systemic cancer multistep therapy (sCMT) combined with chemotherapy in patients with metastatic colorectal cancer: a phase I/II study.

This phase I/II study evaluated the feasibility, toxicity and response rates of von Ardenne's systemic cancer multistep therapy (sCMT) when applied as an adjunct to cytostatic therapy in patients with metastatic colorectal cancer. sCMT consists of whole-body hyperthermia (WBH) at 41.8-42.1 degrees C, hyperglycaemia and hyperoxaemia. All patients who entered the trial first received three monthly courses of chemotherapy (folinic acid, 50 mg, days 1-5; 5-fluorouracil, 425 mg/m2, days 1-5; mitomycin 8 mg/m2, day 1), followed by response evaluation according World Health Organization (WHO) criteria. Responders (partial/complete remission) were assigned to three further courses of chemotherapy, whereas non-responders (stable/progressive disease) were allocated to additional sCMT on day 1 of every subsequent chemotherapy course. The WBH procedure was administered under general anaesthesia employing the Iratherm-2000 radiant heat device. Of 28 patients enrolled, 19 received more than three treatment courses. Eight of these 19 patients had responded to chemotherapy (PR) and thus obtained three further courses of chemotherapy alone. In 10 of 19 patients who had not responded (SD, PD), three additional courses of chemotherapy were combined with sCMT (with 25 sCMT applications). One patient who did not respond to initial treatment declined sCMT and was continued with chemotherapy alone. It was found that sCMT was feasible, but associated with a specific spectrum of grade III/IV toxicity (skin 20%, pain 16%, peripheral nerves 8% of treatment courses). The fact that three patients who did not respond to initial chemotherapy achieved a PR after additional sCMT suggests that sCMT may enhance the effect of chemotherapy in patients with colorectal cancer.

Adult↗

Regional pelvic hyperthermia as an adjunct to chemotherapy (oxaliplatin, folinic acid, 5-fluorouracil) in pre-irradiated patients with locally recurrent rectal cancer: a pilot study.

The aim of this study was to evaluate the feasibility and toxicity of a novel hyperthermic chemotherapy approach for patients with locally recurrent adenocarcinoma of the rectum. All patients were pre-irradiated (> or = 45 Gy) and had histologically proven pelvic recurrence. Hyperthermic chemotherapy was applied according to a modified 'OFF'-schedule with weekly infusions of 43 mg/m2 of oxaliplatin (i.v., 120 min), 500 mg/m2 of folinic acid (i.v., 120 min) and 2.6 g/m2 of continuous infusional 5-fluorouracil (24 h) for 6 consecutive weeks. Oxaliplatin was started in parallel to pelvic radiofrequency hyperthermia that was provided by the BSD 2000-system. A total of 67 applications were administered to nine patients and were well tolerated. A total of 55/67 (82%) chemotherapy courses were applied without dose-reduction. In 62/67 (93%) hyperthermia sessions, a treatment time of > 60 min was maintained. Tolerated power levels were on average 600 W and, thus, slightly lower than those described in curative pelvic hyperthermia schedules. Eight out of 10 episodes of severe (WHO III degrees) toxicity represented typical side-effects of the chemotherapy given (nausea n = 4, diarrhoea n = 3, neuropathy n = 1). Two severe adverse events were firstly attributable to hyperthermia (haematuria, n = 1; deterioration of a decubital ulcer, n = 1). No patient suffered WHO-disease progression during the treatment period. Two patients achieved a partial remission. It is concluded that hyperthermic chemotherapy with oxaliplatin, folinic acid and 5-FU is feasible on an outpatient basis. Overall toxicity was moderate, although hyperthermia may add side-effects to this approach. Results, moreover, suggest a relevant palliative effect in patients with pre-irradiated pelvic recurrence of rectal cancer.

Adenocarcinoma↗

In vitro coronary artery imaging with sixteen-slice helical computed tomography.

PURPOSE: To determine the benefits of submillimeter coronary computed tomography (CT) angiography in vitro. MATERIAL AND METHODS: The coronary arteries of three domestic pigs were filled with contrast agent and depicted with clinically applicable CT angiography protocols with a slice thickness of 0.63 to 2.5 mm. RESULTS: With 2.5 mm slices, only the third-degree coronary artery branches could be discerned. With 1.25 mm slices, some fourth-degree branches of the right coronary artery could be discerned upon maximum intensity projections. With 0.63mm slices, fourth-degree coronary artery branches could be discerned in all locations. CONCLUSION: The introduction of 16-row detector CT with submillimeter z-axis resolution translates into an order-of-magnitude benefit for the depiction of coronary artery branches.

Animals↗

Computed tomography-guided pulmonary nodule localization before thoracoscopic resection.

PURPOSE: To assess the success rate and complication rate of a CT-guided pulmonary nodule-marker system before thoracoscopic resection. MATERIAL AND METHODS: In 24 patients (15 M, 9 F; age range, 18-71 years) a total of 25 pulmonary nodules (in 1 patient 2 lesions simultaneously) were marked with a special wire under CT-guidance and then thoracoscopically resected. We evaluated lesion size, lesion distance to the pleura, the time of intervention, complications, and thoracoscopic success rate. RESULTS: Mean lesion size was 7 mm (range 4-15 mm) and mean lesional distance to the pleura was 13 mm (range 2-31 mm). The pulmonary nodule-marker system was positioned successfully in all 25 pulmonary nodules within 5-11 min (mean 7.5 min). Minimal pneumothoraces were observed in five patients with no requirements of chest drains. In addition, no bleeding complications or hematothorax were observed. All 25 pulmonary nodules could be resected thoracoscopically. However, in one patient (4%), the guide-wire dislocated during thoracoscopy, but the lesion could be successfully resected during thoracoscopy. CONCLUSION: The CT-guided placement of the pulmonary nodule-marker system used here offers a safe and accurate guide for the localization of small pulmonary nodules during thoracoscopic resection.

Adolescent↗

Role of F18-FDG PET for monitoring of radiochemotherapy -- estimation of detectable number of tumour cells.

BACKGROUND: FDG-PET has been proven to be useful for the diagnosis of pancreatic cancer. However, no quantitative data exist concerning its sensitivity for treatment monitoring or early diagnosis. CASE REPORT: We report on a 61-year-old patient with locally advanced cancer of the pancreas head who received sequential radiochemotherapy including gemcitabine and 5-FU/FA. Under this regimen, MR and CT showed a partial remission with a residual mass which seemed to allow surgical treatment for this patient. A pre-operative FDG-PETScan displayed a count rate close to the detection limit of vital residual tumour. An R0 resection was performed successfully. However, histopathology revealed residual tumour at the core of the resected mass that had gone undetected by all imaging modalities. CONCLUSION: The number of vital tumour cells within this specimen was estimated to be 10(6)-10(7). The detection threshold for FDG-PET in pancreatic carcinoma appears to be within this range.

Cell Count↗

Treatment of locally recurrent rectal cancer with special focus on regional pelvic hyperthermia.

Progress in surgery and adjuvant therapy has markedly improved local control and survival rates in patients with primary, non-metastatic rectal cancer. However, the prognosis of patients with locally recurrent disease is still poor, and a realistic chance for repeated treatment with curative intent is still restricted to the minority of cases. Therefore, effective palliation of symptoms and preservation of a good quality of life are the major goals of therapy for most patients with local recurrence of rectal cancer. Here we give a short overview on the options available for the treatment of pelvic recurrence of rectal cancer, with special focus on adjunctive regional pelvic radiofrequency hyperthermia.

Combined Modality Therapy↗

Preoperative localization of parathyroid glands. Use of MRI, scintigraphy, and image fusion.

AIM: Minimally invasive resection of hyperfunctional parathyroid glands is an alternative to open surgery. However, it requires a precise preoperative localization. This study evaluated the diagnostic use of magnetic resonance (MR) imaging, parathyroid scintigraphy, and consecutive image fusion. PATIENTS, METHODS: 17 patients (9 women, 8 men; age: 29-72 years; mean: 51.2 years) with primary hyperparathyroidism were included. Examination by MRI used unenhanced T1- and T2-weighted sequences as well as contrast-enhanced T1-weighted sequences. (99m)Tc-MIBI scintigraphy consisted of planar and SPECT (single photon emission tomography) imaging techniques. In order to improve the anatomical localization of a scintigraphic focus, SPECT-data were fused with the corresponding MR-data using a modified version of the Express 5.0 software (Advanced Visual Systems, Waltham, MA). Results of image fusion were then compared to histopathology. RESULTS: In 14/17 patients, a single parathyroid adenoma was found. There were 3 cases with hyperplastic glands. MRI detected 10 (71%), scintigraphy 12 (86%) adenomas. Both modalities detected 1/3 patients with hyperplasia. Image fusion improved the anatomical assignment of the 13 scintigraphic foci in five patients and was helpful in the interpretation of inconclusive MR-findings in two patients. CONCLUSIONS: Both MRI and (99m)Tc-MIBI scintigraphy sensitively detect parathyroid adenomas but are less reliable in case of hyperplastic glands. In case of a scintigraphic focus, image fusion considerably improves its topographic assignment. Furthermore, it facilitates the evaluation of inconclusive MRI findings.

Adult↗

Diagnosis of neuroendocrine tumours by retrospective image fusion: is there a benefit?

This study evaluated the use of image fusion in the preoperative staging of neuroendocrine tumors (NET) of the pancreas and the gastrointestinal tract (GIT). Thirty-eight patients suffering from a metastasized NET with location of the primary in the pancreas ( n=15) or the GIT ( n=23) were examined by somatostatin receptor scintigraphy (SRS) and computed tomography (CT). Consecutive image registration and fusion were performed using custom-built software integrated in AVS/Express (Advanced Visual Systems, Waltham, MA, USA). Registration was performed by a voxel-based algorithm based on normalized mutual information. Image fusion was feasible in 36/38 patients. A total of 87 foci were assigned to anatomical regions (e.g. gut, pancreas, liver, lymph node or others) by two independent observers in both SRS and SRS/CT fusion images. The assignments used a binary ranking system (1="definite", 0="not definite"). These results were then retrospectively compared to the classification of the foci, based on postoperative histology or clinical follow-up. Imaging by SRS allowed a definite anatomical assignment in 57% (50/87) and 61% (53/87) of all lesions in the case of observers A and B, respectively. Image fusion improved the topographic assignment to 91% (79/87) and to 93% (81/87). The number classified as "definite" by both observers increased from 54% (47/87) to 86% (77/87). The increase in definite assignments was highly significant for both observers ( P<0.0001 for each). In the case of foci classified as liver metastases, image fusion allowed improved assignment to the corresponding liver segment from 45% (18/40) to 98% (39/40) and from 58% (23/40) to 100% (40/40) by observers A and B, respectively. Furthermore, the improved assignment of foci classified as lesions by image fusion was relevant for therapy in 7/36 patients (19%). Therefore, the image fusion technique presented herein appears to be a very useful method for clinical routine.

Adult↗

[Application of multislice detector spiral computed tomography to intracranial aneurysms: first clinical experience].

PURPOSE: To identify advantages when using the new multislice spiral CT technology (MSCT) for the detection and demonstration of intracranial aneurysms with CT angiography (CTA)? MATERIAL AND METHODS: Patients with suspected intracranial aneurysms underwent 4- and 8-slice spiral CTA. Image postprocessing included "maximum intensity projection" (MIP),"volume rendering" (VR) and additionally curved multiplanar reconstructions (MPR) for aneurysms suspected at the carotid siphon. The results were compared with those achieved with digital subtraction angiography (DSA). RESULTS: In 19 patients 21 out of 22 aneurysms were detected by CTA. A high resolution three-dimensional view of the aneurysm morphology in spatial relation to the surrounding structures was achieved. Further information could be gained by making a detailed examination of the inside wall of the aneurysm, using virtual vascular 3D-endoscopy and virtual 3D-craniotomy. CONCLUSION: Compared to DSA,MS-CTA is a useful additional and in selected cases alternative modality for the detection with marked advantages in the demonstration of intracranial aneurysms.

Adult↗

Common herbs, essential oils, and monoterpenes potently modulate bone metabolism.

During our survey of herbs looking for activity on bone metabolism, we found that the dried leaves of sage strongly inhibit bone resorption. Therefore, we investigated several common herbs rich in essential oils (sage, rosemary, and thyme) and essential oils extracted from these herbs and other plants (oils of sage, rosemary, juniper, pine, dwarf pine, turpentine, and eucalyptus) as well as their monoterpene components (thujone, eucalyptol, camphor, borneol, thymol, alpha-pinene, beta-pinene, bornylacetate as well as menthol) and found that they inhibit bone resorption when added to the food of rats. Pine oil, used as a representative essential oil, protects an osteoporosis model, the aged ovariectomized rat, from bone loss. The monoterpenes borneol, thymol, and camphor are directly inhibitory in the osteoclast resorption pit assay. Nonpolar monoterpenes may require metabolism to be active in vitro, for example, cis-verbenol, a metabolite of alpha-pinene occurring in human urine, inhibits osteoclast activity in contrast to the parent compound. Within 30 min borneol inhibits the formation of actin rings, a characteristic of resorbing osteoclasts indicating cell polarization. Both the in vitro and the in vivo effects of borneol are reversible. Our study demonstrates for the first time that essential oils and monoterpenes are efficient inhibitors of bone resorption in the rat.

Animals↗

Cryopreservation with dimethyl sulfoxide sustains partially the biological function of osteochondral tissue.

The clinical routine use of bone allograft transplants dates back to the discovery that grafts devitalized by freezing bear a reduced antigenicity. Graft failures, caused by a host versus graft reaction, however, remain a clinical problem. Previous investigations on pancreatic islet allografts revealed improved survival and biological function when fast cryopreservation (-70 degrees C/min) was performed in the presence of dimethyl sulfoxide (DMSO). The aim of this study was to determine the effect of fast freezing using DMSO on the biological function of osteochondral tissues. Organ culture was performed with neonatal femora of mice, untreated, rapidly frozen (-70 degrees C/min) with DMSO, or frozen without DMSO. After the culture, tissue morphology, cellular proliferation, osteoblast function, osteoclasts, and the presence of antigen-presenting cells were investigated. In untreated control femora histology appeared normal and proliferating and collagen-synthesizing osteoblasts, osteoclasts, and B-cells and macrophages were present. In frozen femora (with and without DMSO) a disintegration of the periosteum and the epiphyseal growth plate were observed and no active osteoblasts could be detected. Osteoclasts were partially detached from the bone surface. Cell proliferation was fully blocked in femora frozen in the absence of DMSO, while freezing in the presence of DMSO preserved cell proliferation in the medullary canal. The proliferating cells do not express epitopes present on the cells of the B-cell or macrophage lineages. Although the biological function of osteoblasts and osteoclasts was lost upon freezing of osteochondral tissue, DMSO included in freezing protocols preserves some residual cell viability which may be of importance for early graft revascularization as has been previously demonstrated by our group.

Acid Phosphatase↗

[Computed tomography of the patellofemoral alignment after arthroscopic reconstruction following patella dislocation].

PURPOSE: To evaluate the diagnostic impact of different CT-based measurements to analyze the patellofemoral alignment after arthroscopic reconstruction in patients with patella dislocation. MATERIALS AND METHODS: In 18 patients with dislocation of the patella, CT of the patellofemoral joint was performed after arthroscopic reconstruction. Various methods recommended in the literature were used to analyze the structure and the alignment of the patellofemoral joint with a relaxed quadriceps muscle. Axial CT scans were taken in four different knee flexion angles (15 degrees, 30 degrees, 45 degrees, 60 degrees ). RESULTS: After arthroscopic stabilization in patients with patella dislocation, only the lateral patellofemoral angle (15 degrees and 30 degrees knee flexion) and the congruence angle (15 degrees knee flexion) showed significant differences between the CT-measurements in the normal and the operated group. The differences of the remaining mean values were not significant due to a high standard deviation. With increasing flexion of the knee, the differences between the normal and the dislocation group almost disappeared. Only the lateral patellofemoral angle, the patella tilt and the lateral patella shift revealed differences between the normal and the group with recurrent dislocation in every degree of knee flexion. With increasing knee flexion above 30 degrees and especially at 60 degrees, the majority of the measured values returned to the normal range. CONCLUSIONS: For CT-measurements of the patellofemoral joint after arthroscopic stabilization, the patellofemoral angle and the congruence angle seemed to be most useful. The measurements of the patellofemoral joint should be taken in various degrees of knee flexion.

Adolescent↗