Search PubMed⌕ Search

Biomedical subjects

R Erbel

Publications and source records attributed to R Erbel.

At least 127 records · Page 7Linked to original sources

[Genetic polymorphism of the G-protein beta3 subunit, obesity and essential hypertension].

Following a classical candidate gene approach we have detected a C825T polymorphism in the gene GNB3 which encodes the G beta 3 subunit of heterotrimeric G proteins. The 825T allele causes alternative splicing of the gene and the generation of a truncated but functionally active splice variant of G beta 3 which is referred to as G beta 3s. Thus, genotyping for the C825T polymorphism is predictive for the activation of certain G proteins in humans. The 825T allele is significantly associated with an increased risk for hypertension in Caucasians, most likely "low renin hypertension" and it accumulates significantly in individuals with a strong family history of hypertension. Highest frequencies of the 825T allele (up to 80%) are found in old ethnicities, e.g. black Africans, African Americans, bushmen, and Australian aborigines. This suggests that enhanced G protein activation represents a thrifty genotype which might have facilitated survival in our ancestors. Frequencies of the 825T allele are significant lower in Asians (approximately 40 to 50%) and Caucasians (30%). More recent studies show that young 825T allele carriers are predisposed for obesity and this association could be confirmed across different ethnicities including young Germans, as well as Chinese and black African individuals. Thus, genotyping at the GNB3 locus represents an ideal tool for preventive medicine in that individuals at risk for obesity and hypertension can be identified early and counteract their genetic predisposition through changes in lifestyle. In individuals with borderline hypertension genotyping can facilitate the decision for medical treatment as a positive test result confirms an inherited form of hypertension.

Alleles↗

[Electromechanically controlled versus roengenologically guided percutaneous transluminal laser myocardial revascularization].

Transmyocardial laser revascularization is a modern therapeutic concept for patients with end-stage coronary artery disease not eligible for bypass surgery, percutaneous coronary interventions or heart transplantation. Although the principal idea of creating additional myocardial perfusion from the cavum of the left ventricle was derived from observations in reptile hearts, histological investigations suggest that channel patency is not the underlying mechanism for improved clinical symptoms. Sympathetic denervation and angioneogenesis may be additional explanations for improvement of angina and stress tolerance. The first experiences with transmyocardial laser revascularization were made using a surgical approach. Two randomized multicenter trials could show a significant improvement in angina and stress tolerance 12 months after creating channels using laser technique. While these results were obtained by performing thoracotomy, catheter-based systems have been designed for a less invasive approach of this technique. A further advantage of these new systems is that regions like the septum can be treated which are not eligible for a surgical approach. Using percutaneous transluminal catheter-based systems channels of up to 6 mm length can be created. Beside the fluoroscopic guided creation of myocardial channels a new mapping system has been applied using electromechanical features of viable myocardial tissue. This system is based on the observation that endocardial electrograms recorded from an infarcted area are characterized by very low amplitude and fractionated morphology. This system allows online mapping of viable myocardium and provides spatial, electrical, and mechanical information of the myocardium. This method of electromechanical mapping highly correlates with results obtained from myocardial perfusion scans. Recent preliminary clinical trials demonstrated that catheter-based creation of myocardial channels is a feasible and successful alternative to the surgical laser revascularization. Also with this approach a significant improvement in angina and stress tolerance can be achieved. The results of the PACIFIC study, the first randomized multicenter study using percutaneous transluminal laser revascularization, demonstrates that after 3 and 6 months more than half of the patients presented improved angina of at least 1 Canadian-Cardiovascular-Society class. Whether electromechanical guided myocardial laser revascularization is more efficient than fluoroscopic guided has not been proven yet. Further studies will have to evaluate this issue.

Animals↗

[Contrast medium echocardiography-assisted pericardial drainage].

The most effective treatment for pericardial effusion and cardiac tamponade is removal of the pericardial fluid. Surgical pericardiotomy is associated with high mortality and morbidity. Similarly, subcostal percutaneous blind pericardiocentesis was reported to have unacceptably high mortality and complication rates. Major complications associated with blind needle punctures are right heart penetration, hemopericardium, puncture of the coronary arteries, liver and lung bleeding. Even under fluoroscopic guidance and electrocardiographic needle monitoring high complication rates persist. Pericardial drainage has been often inadequate, with frequent recurrences of significant pericardial effusions. Two-dimensional echocardiographically guided pericardiocentesis is reported to improve efficacy and safety of percutaneous puncture. Moreover, it allows immediate verification of the procedural success. We evaluated the efficacy and safety of an echocardiographically guided contrast agent controlled pericardiocentesis. This is a retrospective, descriptive study on 126 consecutive patients who underwent percutaneous pericardiocentesis at the University Hospital Essen, Germany, from 1995 to June 2000. There were 51 women (41%) and 75 men (55%) with a mean age of 52 +/- 14 years. Standard techniques for quantification of pericardial effusion were used. Depending on the localization of the pericardial effusion an apical or subxiphoidal approach was chosen. The puncture was performed under echocardiographic guidance and the position of the needle was controlled by injection of contrast agent. Over a long guidewire a pigtail catheter was inserted through a sheath for further drainage of pericardial fluid. The catheter was removed after a maximum of 48 hours to avoid infection of the pericardial cavity. An apical approach was chosen in 98 patients (78%), a subcostal in 28 patients (22%). The procedure was successful in 99% of the attempts. No death or clinical complication occurred. The maximal pericardial diameter measured by two-dimensional echocardiography was 32 +/- 16 mm before and 5.3 +/- 2 mm after drainage. The calculated pericardial effusion was 657 +/- 342 ml. A fluid volume of 605 +/- 342 ml could be drained. In all patients a pericardial catheter was placed for 1.4 +/- 0.8 days. Recurrence of pericardial effusion occurred in 18 patients (14%). Of these, 15 patients underwent repeated successful pericardiocentesis (2.5 +/- 0.8), and 3 patients were referred to surgical pericardiotomy. Pericardiocentesis under echocardiographic contrast agent guidance is a safe, successful and cost effective procedure for diagnostic and therapeutic drainage of pericardial effusion. Two-dimensional echocardiography allows localization of the optimal puncture site as well as the quantification of the effusion depth. The injection of contrast agents into the pericardial cavity improves the safety and accuracy of the procedure. Even recurrent pericardial effusions can be treated successfully.

Adult↗

[A standardized documentation structure for data documentation in echocardiography. Work Team on Standards and LV Function of the Work Group on Cardiovascular Ultrasound of the German Society of Cardiology, Heart and Circulation Research].

Presently, there are no well-defined standards for documentation of echocardiographic studies. Nevertheless, standards are essential to provide comparability of data and to realize electronic communication, both essential for quality management in echocardiography. Therefore, the working group "Standards and LV function" of the German Society of Cardiology developed a consensus for documentation of echocardiographic studies. In the present paper this consensus is presented and illustrated by typical clinical examples. Additionally, a prototype of a user-oriented software based on this data set is presented. The complete data set for transesophageal and transthoracic echocardiography and the software prototype can be downloaded at http:@echo.ma.uni-heidelberg.de.

Aortic Valve Stenosis↗

[Clinical significance of coronary calcifications in electron beam tomography].

Electron-beam computed tomography (EBCT) permits high-resolution imaging of the beating heart and the coronary arteries and visualization of coronary calcification. For clinical purposes, coronary calcification represents the formation of atherosclerotic plaques. EBCT provides for accurate quantification of calcification, which is itself related to the extent of coronary atherosclerosis in a linear fashion. Accordingly, EBCT has been shown to measure the extent of coronary atherosclerosis. Importantly, an EBCT scan negative for calcification has a high negative predictive value indicating the absence of obstructive coronary artery disease and an excellent short- to midterm prognosis. It appears that, in general, the amounts of calcification detected by EBCT can be used for prospective risk stratification in symptomatic and asymptomatic adults. However, data derived from unbiased populations are not available at present, and the role of calcification in predicting acute coronary syndromes remains debated. Longitudinal EBCT examinations have emerged as another area of substantial clinical interest. The clinical value of this method remains to be defined, in particular, in comparison with competing, established modalities.

Adult↗

[Transluminal exclusion of a subclavian artery aneurysm with stent-graft implantation].

In a 73 year-old male patient with generalized atherosclerosis, known infrarenal abdominal aortic aneurysm, renal artery stenosis, and coronary artery disease, an aneurysm of the proximal left subclavian artery was successfully excluded by implantation of a JOSTENT-Peripheral stent graft. Angiographic follow up after 6 and 12 months showed an excellent outcome with complete exclusion of the aneurysm. Intravascular ultrasound showed no neo-intimal hyperplasia within the stent. A computed tomography revealed complete thrombosis of the aneurysm.

Aged↗

[Biophysical study of coronary stents: which factors influence the dilatation and recoil behavior?].

In Europe more than fifty stents are currently available for the therapy of coronary artery disease. Nonetheless it is unknown whether material and design influence the stent's behavior. We have studied the recoil and dilatation behavior of five currently available stainless steel (316L) stents compared to stent prototypes made of pure titanium. Furthermore we have investigated how the behavior is influenced by the process of crimping. The aim of this work was to determine material and design characteristics, which influence the recoil and dilatation behavior. The 316L stents showed a homogeneous behavior (plateau pressure min. 1.15 +/- 0.01 atm, max. 0.26 +/- 0.03 atm, recoil min. 0.15 +/- 0.03%, max. 0.26 +/- 0.03%). The titanium stent showed a linear response to the balloon expansion. This was seen in a significantly lower plateau pressure (0.43 +/- 0.15 atm, p < 0.001). Despite the material characteristics of titanium, there were no significant differences in the recoil behavior (0.28 +/- 0.02%). Crimping leads to stent alterations which result in a significantly higher plateau pressure (1.9 +/- 0.07 atm vs. 2.7 +/- 0.58 atm, p < 0.001) and a reduced end-diameter (3.6 +/- 0.02 mm vs. 3.54 +/- 0.05 mm, p < 0.005). The presented data show that the dilatation behavior is relying on the stent material while the recoil is strongly influenced by the stent design.

Angioplasty, Balloon, Coronary↗

X-ray densitometry for the measurement of regional myocardial perfusion.

The evaluation of regional myocardial blood flow (RMBF) during cardiac catheterization is of particular diagnostic interest. The purpose of this investigation was to validate x-ray densitometric parameters for the evaluation of RMBF. In five anesthetized dogs, arterial flow in the circumflex coronary artery was measured continuously with an electromagnetic flowmeter, and RMBF was determined by colored microspheres. Five different perfusion levels were created by mechanical obstruction of the coronary artery or by intravenous infusion of adenosine. At each steady-state perfusion level, digital subtraction coronary angiograms were obtained for densitometric analysis. Results documented a close correlation between the related time parameters 1/Mean Transit Time (1/MTT, r2 = 0.969), and 1/Rise Time (1/RT, r2 = 0.965) and RMBF over a wide range between 0.36 ml/(min x g) and 11.16 ml/(min x g). Maximum myocardial contrast density (Imax) also showed a good, but inverse correlation (r2 = 0.889) with RMBF and, therefore, did not reflect vascular volume. Contrast medium Appearance Time (AT) showed no correlation to RMBF (r2 = 0.017). Repeat densitometric measurements for different perfusion levels revealed a good reproducibility for MTT (accuracy: 0.001 s; precision: 0.447 s or 6.7 %) and RT (accuracy: 0.014 s; precision: 0.202 s or 10.4 %), while AT (accuracy: 0.072 s; precision: 0.420 s or 68.5%) and Imax (accuracy: 0.022 GL; precision: 1.197 GL or 44.5%) showed substantial variation. Myocardial perfusion reserve (MPR) calculated from RT (r2 = 0.90) or MTT (r2 = 0.94) showed better correlations to RMBF reserve than MPR calculated from AT (r2 = 0.04). In conclusion, only 1/MTT and 1/RT showed a good reproducibility and a close correlation to RMBF. Therefore, only these parameters can be recommended for calculations of RMBF and its reserve under clinical conditions.

Absorptiometry, Photon↗

Corrected coronary flow velocity reserve: a new concept for assessing coronary perfusion.

OBJECTIVES: In order to limit the variability of coronary flow velocity reserve (CFVR), we analyzed which factors independently affect CFVR and established a new parameter integrating these factors. BACKGROUND: Coronary flow velocity reserve (CFVR) is a frequently used parameter for evaluating the physiological significance of epicardial stenosis and microvascular function. Since CFVR measurements are done in substantially different hemodynamic and clinical situations, interpretation of CFVR requires correction for major influencing factors. METHODS: In 141 patients with angina-like symptoms and angiographically unobstructed coronary arteries, intracoronary Doppler measurements were performed in at least two coronary vessels. Coronary flow velocity reserve was calculated as the ratio of hyperemic average peak velocity (hAPV), after intracoronary bolus of adenosine, to baseline average peak velocity (bAPV). RESULTS: Analysis of covariance revealed that only bAPV (p < 0.0001) and age (p < 0.0001) were independent factors influencing CFVR. Based on a regression model for estimation of predicted CFVR values, individual CFVR values (CFVRind) obtained at different bAPV and age were transformed in corrected CFVR values (CFVRcorr) by relating them to a mean bAPV of 15 cm/s and a mean age of 55 years. The transformation from CFVRind into CFVRcorr for the left anterior descending artery can be done by using the following equation: CFVRcorr = 2.85*CFVR(ind)*10(0.48*log(bAPV)+(0.0025*age)-1.16). When applying this new parameter to conditions assumed to cause microvascular dysfunction, analysis showed that only patients with diabetes showed a significant decrease of traditional CFVR and CFVRcorr, whereas a history of hypertension and current smoking habit had no influence on CFVRcorr. CONCLUSIONS: The concept of CFVRcorr standardizes CFVR for bAPV and age as the major physiological determinants. Especially in patients with microvascular dysfunction, this approach may help to discriminate between conditions directly affecting vasodilator reserve and conditions primarily affecting bAPV.

Blood Flow Velocity↗

Dose-dependent effects of intracoronary verapamil on systemic and coronary hemodynamics.

Calcium antagonists are used in interventional cardiology to prevent coronary vasoconstriction or to overcome the no-reflow phenomenon. The aim of the current study was to evaluate the dose-dependent effects of intracoronary verapamil on systemic and coronary hemodynamics. In 20 patients scheduled for routine coronary angiography, heart rate, blood pressure, and ECG recordings were recorded continuously and intracoronary flow velocity was obtained by intracoronary Doppler measurements in angiographically normal vessels. The cross-sectional area, measured by quantitative coronary angiography, allowed the calculation of coronary blood flow (CBF) and the coronary vascular resistance index (CVRI). Without premedication, increasing dosages of verapamil (0.01 mg, 0.1 mg, 1.0 mg, and 2.0 mg) were injected into the left coronary artery. Intracoronary verapamil administration led to a decrease in systemic blood pressure only after administration of 1.0 mg or 2.0 mg (change in mean arterial pressure: from 87.6 +/-14.6 mmHg to 80.1 +/- 14.9 mmHg and 78.5 +/- 13.9 mmHg, respectively; both P < 0.05) without a change in heart rate. Epicardial diameters of the left coronary artery increased only at dosages of 1.0 mg and 2.0 mg (from 2.14 +/- 0.4 mm to 2.22 +/- 0.3 mm, P < 0.01), whereas the coronary blood flow velocity increased significantly at the smallest dosage of 0.01 mg (from 19.9 +/- 8.7 cm/s to 33.2 +/- 14.9 cm/s, P < 0.001) and was further enhanced with increasing dosages. CBF increased and CVRI decreased at every dosage of verapamil compared with baseline values. CBF increased also after 0.1 mg (from 13.5 +/- 6.5 mL/min to 19.5 +/- 9.3 mL/min; P < 0.05), reaching a maximal effect after administration of 1.0 mg verapamil (26.3 +/- 16.1 mL/min, P < 0.05). Application of 2.0 mg did not further increase CBF compared with 1.0 mg. Intracoronary application of verapamil leads to a decrease in systemic blood pressure at higher dosages, whereas heart rate remains unchanged at any dosage. The maximal increase in coronary blood flow and decrease in vascular resistance can be reached by administration of 1.0 mg verapamil into the left coronary artery.

Adult↗

Tissue Doppler imaging: a new technique for assessment of pseudonormalization of the mitral inflow pattern.

Left ventricular diastolic dysfunction (LVDD) is a frequent cause of heart failure. Doppler echocardiography has become the method of choice for the noninvasive evaluation of LVDD. However, pseudonormalization (PN) of the mitral inflow often presents a diagnostic challenge in clinical practice. In this setting, we sought to define the role of tissue Doppler imaging (TDI) of the septal mitral annulus. Echocardiography was performed in 36 consecutive subjects (age 59 +/- 10 years). Eighteen of these had diagnosed coronary artery disease (CAD) with recent onset of symptoms (within 3 months), 18 had clinical suspicion of CAD, and 15 had symptoms of heart failure (New York Heart Association [NYHA] Class 2.4 +/- 0.5). The mitral inflow profile (E, A, E/A) was measured by pulsed Doppler, and the deceleration time (DT) and the isovolumic relaxation time (IVRT) were calculated. Peak diastolic velocities of the septal mitral annulus (E(T), A(T), E(T)/A(T)) and the time interval from Q in the ECG to the onset of E(T) were derived from pulsed TDI. Left heart catheterization was performed for direct measurement of left ventricular end-diastolic pressure (LVEDP). PN defined by an E/A ratio > 1 and an LVEDP > or = 16 mmHg was found in nine patients. All patients with PN had symptoms of heart failure (NYHA Class 2.8 +/- 0.5). Patients with and without PN did not differ with respect to the E/A ratio (1.29 +/- 0.44 vs 1.16 +/- 0.23, P = ns), DT (182 +/- 38 msec vs 205 +/- 42 msec, P = ns), and IVRT (88 +/- 24 msec vs 92 +/- 18 msec, P = ns). In the group with PN, a significant reduction of E(T) (5.6 +/- 1.8 cm/sec vs 8.8 +/- 2. 9 cm/sec, P < 0.05) and E(T)/A(T) (0.5 +/- 0.16 vs 0.82 +/- 0.37, P < 0.05) was detected. In the PN group, the Q-E(T) interval was prolonged (404 +/- 48 msec vs 346 +/- 50 msec, P < 0.05). Receiver operating characteristic curve analysis for E(T) yielded an area under the curve of 0.78 +/- 0.06 (P = 0.034) for separating patients with versus without PN. When the combination of E(T) < 7 cm/sec and E(T)/A(T) < 1 was used as cutpoint, PN could be identified with a sensitivity of 83% and a specificity of 79%. There was no significant relation between LVEDP and either E(T) (r = 0.32, P > 0. 2) or the Q-E(T) interval (r = 0.14, P > 0.5). In conclusion, E(T) and the Q-E(T) interval appear to be useful parameters for assessing LV diastolic dysfunction in symptomatic patients with a pseudonormal mitral inflow pattern and elevated filling pressures.

Aged↗

Assessment of coronary calcification by electron-beam computed tomography in symptomatic patients with normal, abnormal or equivocal exercise stress test.

AIMS: Exercise stress testing is often used as the initial non-invasive diagnostic test in symptomatic patients with suspected obstructive coronary artery disease. Positive standard ECG criteria are quite specific for obstructive coronary artery disease, but there may be a substantial number of false negative tests, including patients with severe coronary artery disease. Also, exercise stress tests frequently yield equivocal results. Instead of detecting the functional consequences, electron-beam computed tomography visualized atherosclerotic plaque disease directly, but its relationship to functional testing has not been clearly delineated. It was the aim of the current study to examine electron-beam computed tomography for the identification of obstructive coronary artery disease in patients with a normal, abnormal, or equivocal exercise stress test. METHODS AND RESULTS: Symptomatic patients referred for coronary angiography were prospectively included in a consecutive manner if they had no prior diagnosis of coronary artery disease and an unremarkable resting ECG. All patients underwent both exercise stress test and electron-beam computed tomography on the day before coronary angiography. Standard protocols and ECG criteria to diagnose inducible ischaemia were used for the exercise stress test. The electron-beam computed tomography-derived total calcium score was computed according to standard Agatston criteria. Of the 323 patients (mean age, 55+/-11 years; 77% male), 179 (55%) had obstructive coronary artery disease, defined angiographically as luminal diameter narrowing >/=50%. A normal exercise stress test was documented in 105 patients (32.5%), an abnormal exercise stress test ('diagnostic for ischaemia') in 113 (35%), and an equivocal exercise stress test ('inadequate exercise or non-diagnostic ECG-changes') in 105 (32.5%). Multivariate analysis indicated that exercise stress test and electron-beam computed tomography yielded independent information for predicting obstructive coronary artery disease. Sensitivity, specificity and overall accuracy of the exercise stress test were 71%, 75% and 73%, respectively, if equivocal tests were not included, and 50%, 84% and 65% if they were included. Irrespective of the cutpoint regarded as 'positive', the overall accuracy of the electron-beam computed tomography-derived calcium score remained approximately 80% in patients with a normal, abnormal or equivocal exercise stress test. In patients with an equivocal and - to a lesser degree - with a normal exercise stress test, electron-beam computed tomography was able to significantly improve classification regarding obstructive coronary artery disease. Electron-beam computed tomography added no incremental predictive value in patients with an abnormal exercise stress test. CONCLUSION: In patients who are judged to have an intermediate post-test probability of disease after exercise stress test, electron-beam computed tomography scanning may be a meaningful strategy for further stratification regarding the likelihood of obstructive coronary artery disease.

Calcinosis↗

A randomized comparison of balloon angioplasty versus rotational atherectomy in complex coronary lesions (COBRA study).

AIMS: Rotablation is a widely used technique for the treatment of complex coronary artery lesions but is so far only poorly supported by controlled studies. The Comparison of Balloon-Angioplasty versus Rotational Atherectomy study (COBRA) is a multicentre, prospective, randomized trial to compare short- and long-term effects of percutaneous transluminal coronary angioplasty (PTCA) and rotablation in patients with angiographically pre-defined complex coronary artery lesions. METHODS AND RESULTS: At seven clinical sites 502 patients with pre-defined complex coronary artery lesions were assigned to either PTCA (n=250) or rotablation (n=252). Primary end-points were procedural success, 6-month restenosis rates in the treated segments, and major cardiac events during follow-up. Procedural success was achieved in 78% (PTCA), and 85% (rotablation) (P=0.038) of cases. Crossover from PTCA to rotablation was 4% and 10% vice versa (P=0.019). There was no difference between PTCA and rotablation with respect to procedure-related complications such as Q wave infarctions (2.4% each), emergency bypass surgery (1.2% versus 2.4%), and death (1.6% versus 0.4%). However, more stents were required after PTCA (14.9% versus 6.4%, P<0.002), predominantly for bailout or unsatisfactory results. Including bail-out stents as an end-point, the procedural success rates were 73% for angioplasty and 84% for rotablation (P=0.006). At 6 months, symptomatic outcome, target vessel reinterventions and restenosis rates (PTCA 51% versus rotablation 49%, P=0.33) were not different. CONCLUSION: Complex coronary artery lesions can be treated with a high level of success and low complication rates either by PTCA with adjunctive stenting or rotablation. The long-term clinical and angiographic outcome is comparable.

Adult↗

Tei-index in patients with mild-to-moderate congestive heart failure.

BACKGROUND: Congestive heart failure is related to contraction and relaxation abnormalities of the ventricle. Isolated analysis of either mechanism may not be reflective of overall cardiac dysfunction. A combined myocardial performance index (isovolumic contraction time plus isovolumic relaxation time divided by ejection time, 'Tei-Index') has been described which may be more effective for analysis of global cardiac dysfunction than systolic and diastolic measures alone. It was the aim of the present investigation to evaluate the Tei-Index against invasive examination. METHODS AND RESULTS: Eighty-one subjects were included in a consecutive manner, among 125 patients undergoing left heart catheterization for invasive measurement of left ventricular end-diastolic pressure; 43 patients had congestive heart failure (35 male, 8 female, 68+/-6 years) defined by NYHA functional class >/=2 (mean 2.5+/-0.5) and left ventricular end-diastolic pressure >/=16 mmHg (mean 20+/-4) and 38 subjects (32 male, 6 female, 66+/-5 years) without symptoms of heart failure (NYHA functional class I) and with normal left ventricular end-diastolic pressure (mean 12+/-3 mmHg) served as a control group. Using conventional echo-Doppler methods, parameters assessed were: ejection fraction, peak velocities of early (E) and late (A) diastolic filling, the E/A ratio, deceleration time, isovolumic contraction time, isovolumic relaxation time and ejection time. The Tei-Index was obtained by subtracting ejection time from the interval between cessation and onset of the mitral flow. The control group and patients with congestive heart failure did not differ with respect to the E/A ratio (0.86+/-0.27 vs 0.90+/-0.44, P=ns), deceleration time (203+/-42 ms vs 206+/-36 ms, P=ns) and isovolumic relaxation time (97+/-16 ms vs 94+/-26 ms, P=ns). The ejection fraction was slightly reduced in patients with congestive heart failure (46+/-11% vs 55+/-8%, P<0.05). The Tei-Index was easily and reproducibly measured in all subjects. The mean value of the Tei-Index was significantly different between the control group and patients with congestive heart failure (0.39+/-0.10 vs 0.60+/-0.18, P<0.001). Receiver operating characteristic curve analysis for the Tei-Index yielded an area under the curve of 0.88+/-0.038. Using a Tei-Index >/=0.47 as the cutpoint, congestive heart failure was identified with a sensitivity of 86% and a specificity of 82%. No correlation was observed between the Tei-Index and heart rate (r=0.22, P=ns), systolic blood pressure (r=0.16, P=ns) or diastolic blood pressure (r=0.08, P=ns). The Tei-Index was significantly related to left ventricular end-diastolic pressure (r=0.46, P<0.01). CONCLUSION: The Tei-Index is a sensitive indicator of overall cardiac dysfunction in patients with mild-to-moderate congestive heart failure. The Tei-Index is easily obtained and may be used in the work-up of patients with suspected cardiac dysfunction.

Aged↗

Safety of intracoronary Doppler flow measurement.

BACKGROUND: With the introduction of Doppler-tipped guide wires, intracoronary Doppler flow measurement has been increasingly accepted as an additional diagnostic approach in the catheterization laboratory. However, the safety of intracoronary Doppler flow measurement has not been well-investigated. The purpose of our study was to evaluate the safety of intracoronary Doppler flow measurement using the Doppler FloWire (Cardiometrics, Mountain View, Calif). METHODS AND RESULTS: A total of 906 patients were examined by intracoronary Doppler with a 0.014-inch or an 0.018-inch Doppler FloWire. For coronary flow reserve measurement, intracoronary injection of adenosine or papaverine was used. Of the patients studied, 77 were cardiac transplant recipients and 829 were patients who had not received a transplant, of whom 617 had undergone diagnostic coronary procedures and 212 had coronary interventions. In 27 (2.98%) of 906 patients adverse cardiac events were observed. Fifteen (1.66%) of 906 patients had severe transient bradycardia develop (asystole or second- to third-degree atrioventricular block) after intracoronary administration of adenosine, 14 of which occurred in the right coronary artery and 1 in the left anterior descending artery. Nine (0.99%) of 906 patients had coronary spasm during the passage of the Doppler wire (5 in the right coronary artery, 4 in the left anterior descending artery). Two (0.22%) of 906 patients had ventricular fibrillation during the procedure. Hypotension with bradycardia and ventricular extrasystole each occurred in 1 (0.11%) of 906 patients. The incidence of complication was significantly higher in transplant recipients than in patients who underwent either diagnostic or interventional procedures (12.99% vs 2.43% vs 0.94%, P <.001). The Doppler measurements in the right coronary artery were associated with a higher incidence of complications, especially bradycardia, compared with the left anterior descending and the left circumflex arteries (right coronary, 5.87% vs left anterior descending, 1.05% vs left circumflex, 0.17%; P <.001). All complications were cured medically. CONCLUSION: Intracoronary Doppler flow measurement with Doppler wires and intracoronary administration of adenosine is a safe method. However, severe complications such as bradycardia and coronary spasm can occur. Attention should be paid to the examination of the right coronary artery, especially in heart transplant recipients.

Adenosine↗

Immediate stent implantation versus conventional techniques for the treatment of abrupt vessel closure or symptomatic dissections after coronary balloon angioplasty.

BACKGROUND: Coronary stenting was initially designed to treat a bailout scenario. Prospective randomized trials comparing stent implantation with standard techniques, including emergency coronary artery bypass grafting, are lacking. The aim of this trial was to test the superiority of immediate stent implantation compared with standard techniques for the treatment of abrupt or threatening closure after coronary balloon angioplasty. METHODS: In a prospective trial, 100 patients with abrupt vessel closure or symptomatic dissections causing objective signs of ischemia were randomly assigned to treatment with immediate placement of stents (n = 51) versus standard techniques such as prolonged dilatation or emergency bypass surgery (n = 49). The primary end point was the achievement of successful stabilization not requiring crossover to the other study group. Secondary end points included event-free survival and restenosis. RESULTS: Successful stabilization was achieved in 94% of patients in the stent group compared with 78% of patients in the standard treatment group (P =.038). Two patients died in each group, and there was a trend toward a higher incidence of myocardial infarction (16% vs 8%; P =.163) and a significantly increased creatine phosphokinase level (245 IU/L [95% confidence interval, 217-265 IU/L] vs 179 IU/L [confidence interval 140-212 IU/L]; P =.0002) in the standard treatment group. Event-free survival after 250 days was 72% in the stent group compared with 29% in the standard treatment group (P =.001). The angiographic restenosis rate was 30% in the stent group versus 59% in the standard treatment group (P =.01). CONCLUSIONS: Immediate stenting, if technically feasible, shows superior short- and long-term results compared with standard treatment options.

Aged↗