Search PubMed⌕ Search

Biomedical subjects

R Edwards

Publications and source records attributed to R Edwards.

At least 73 records · Page 4Linked to original sources

Predictors of attendance in the United Kingdom flexible sigmoidoscopy screening trial.

OBJECTIVE: To investigate predictors of attendance in the United Kingdom flexible sigmoidoscopy screening trial. DESIGN: Prospective design in which participants completed a postal questionnaire before being sent their invitation for screening. SETTING: Welwyn Garden City and Leicester, United Kingdom. PARTICIPANTS: A total of 2758 patients aged 55 to 64, registered with general practices in the two centres, who (a) expressed interest in having the screening test, (b) completed a postal questionnaire, and (c) were subsequently invited for screening. MAIN RESULTS: The attendance rate among questionnaire responders was 76.1%. Multiple logistic regression analysis yielded a final model that included nine independent predictors of attendance. Patients with the following characteristics were more likely to attend: men; home owners; non-smokers; those who had regular check ups at the dentist; those with better subjective health; those who minded less about having medical tests; those who said they would definitely rather than probably take up the offer of sigmoidoscopy screening; and those who perceived less barriers and more benefits to having the test. CONCLUSIONS: The findings are broadly consistent with previous studies of screening participation, although subjective health emerged as an important predictor in this study. There was no evidence for "reverse targeting": attenders were not at lower (or higher) risk for colorectal cancer compared with non-attenders. The findings relating to attitudes and beliefs could be used in efforts to improve attendance, for example by developing information leaflets that address barriers to screening. Other findings could be used to target interventions to subgroups that have relatively low rates of screening participation.

Age Factors↗

Measurement of glycated haemoglobin in whole blood by a novel fluorescence quenching assay.

We describe a method for the specific measurement of glycated Hb (GHb) by fluorescence quenching. Whole blood is added to lysing solution, then the lysate is mixed with eosin-boronic acid solution and reacted for at least 5 min at room temperature. The quenching of the fluorescence of the eosin-boronic acid solution is proportional to the concentration of GHb present. Total Hb concentration was measured by absorbance and the GHb expressed as a percentage of the total Hb. Comparison with a commercial high-performance liquid chromatography (HPLC) system for HbA1c showed: %GHb=1.30 (SD 0.04) %HbA1c + 1.36 (SD 0.30), S(y/x) 0.803, n=95, r=0.965 (SD=standard deviation). Intra-assay coefficients of variation were <2.5% (for GHb concentrations in the range 6-20%) and inter-assay coefficients of variation were <4.1% (10 assays on six samples with GHb concentrations in the range 6-20%). Linearity of response was demonstrated by dilution. The effect of adding exogenous glucose, bilirubin and triglycerides was tested on samples with low, medium and high GHb concentrations. No significant interference was found. Variation of haematocrit over the range 0.4-0.6 also had no significant effect on percentage GHb. Preliminary results with samples containing variant Hb (HbAS and HbAC) indicated good agreement with HPLC for these samples also.

Boronic Acids↗

A reliable non-separation fluorescence quenching assay for total glycated serum protein: a simple alternative to nitroblue tetrazolium reduction.

A simple non-separation assay for the measurement of total glycated serum protein is described. It was found that the fluorescence intensity of a solution of a fluorescein-boronic acid derivative was quenched in proportion to the amount of serum added. This led to the development of an assay in which 10 microL of serum is added to 4 mL of a solution of the fluorescein-boronic acid derivative and the fluorescence intensity is measured after 15 min. The results, as measured by drop in fluorescence intensity, calibrated by a single standard, were compared with the results for nitroblue tetrazolium (NBT) reduction of fructosamine and showed good correlation (r=0.936, n=114). The intra-assay precision (seven samples each measured 10 times) was less than 2.1% (concentration range 190-660 micromol/L); inter-assay precision for seven samples in 10 assays was less than 2.5% (over the same concentration range). Dilution of serum that had a high concentration of total glycated protein showed the assay to be linear. Serum samples (with low, medium and high total glycated protein concentrations) showed less than 2.1% difference from base results with added glucose (up to 60 mmol/L), less than 9.7% difference with added bilirubin (up to 250 micromol/L) and less than 6.9% with added triglycerides (up to 50 mmol/L). Addition of haemoglobin (up to 0.9 g/dL) with high glycation (11.7% HbA1c) to plasma (298 micromol/L total glycated protein) showed less than 10% difference from the base result. Assays performed over a range of temperatures (12-34 degrees C) showed no significant differences in the results. The assay gives similar results to the currently used NTB method but with significantly less susceptibility to interferences. As such the method should be a useful aid in the management of diabetes.

Blood Proteins↗

Physiological tremor: does handedness make a difference?

The purpose of this study was to quantify with precision the characteristics of normal physiological tremor in the dominant and nondominant hand of a group of right-handed females. Twenty-two right-handed females (aged 20 to 40) gave informed consent to participate. Manual dominance determined with a questionnaire had to be equal to, or above 90%, for subjects to be accepted in the study. While the subjects kept their eyes closed, tremor was recorded simultaneously in the two extended index fingers during 40 s. Preceding the recording of postural tremor there was a period during which the subjects were asked to relax (control condition); to exert a pressure with the two index fingers on two strain gauges (static condition); or to press on and off with both index fingers on two strain gauges (dynamic condition). Each condition was recorded twice with two helium neon velocity lasers. This procedure was repeated after permutation of the lasers, thus a total of twelve sweeps of data were recorded. Seven parameters were used to analyze the tremor signal including measures of harmonicity, median frequency, proportional power in the 7-12 Hz range, amplitude, waveform morphology, entropy, and nonlinearity. Significant differences between hands were found in three parameters (median frequency, power in 7-12 Hz and entropy) but not in tremor amplitude (RMS). In addition, significant differences were found in five out of seven characteristics between conditions. These results suggest that neuromotor activity preceding the recording of tremor has a significant influence on tremor characteristics and that some of these characteristics are significantly different between the right and left hand in right-handed females.

Adult↗

The measurement of tremor using a velocity transducer: comparison to simultaneous recordings using transducers of displacement, acceleration and muscle activity.

Precise kinematic measurements of tremor have historically been obtained using accelerometers. However, current technology permits precise measurements in velocity and displacement. The primary advantage of velocity recording is that only one step of integration or differentiation is required for either displacement or acceleration. A method is presented of measuring finger tremor using a laser system that transduces velocity precisely. Measurements of postural finger tremor thus obtained were compared to those simultaneously obtained from a laser system that transduces displacement, from an accelerometer and from surface electromyography (EMG) of the extensor digitorum communis. A range of amplitude and frequency content was obtained by testing control subjects and subjects with Parkinson's disease. The velocity transducer showed excellent correspondence of amplitude and frequency measurement with the displacement transducer. Measures of absolute and relative amplitude correlated well (r > or = 0.96 in amplitude measures in displacement, velocity and acceleration), and high coherence was found throughout the frequency range of interest. Measurements by the accelerometer generally showed poorer correspondence with those of the other instruments. EMG measurements showed good correspondence in some trials but poorer correspondence in others, attributed to the low level of muscle activity required in the task. Precise kinematic measurements appear to be highly sensitive to neuromotor impairment.

Acceleration↗

Individuals from North America, Australasia, and Africa are infected with four different genotypes of human herpesvirus 8.

To study human herpesvirus 8 (HHV-8) transmission between individuals and in populations, we developed a system for genetic fingerprinting of HHV-8 strains based on variation in the HHV-8 K1, glycoprotein B (gB), and glycoprotein H (gH) genes. Using this system, we sequenced nearly the entire K1 gene (840 bp); two segments of the gB gene (open reading frame 8), totaling 813 bp; and a 702-bp segment of the gH gene (open reading frame 22) from blood and tissue samples obtained from 40 human immunodeficiency virus-infected and noninfected individuals, including those with Kaposi's sarcoma, primary effusion lymphoma, or Castleman's disease. The specimen collection was assembled from individuals living in diverse geographical locations, including the United States, Australia, New Zealand, Uganda, and Zambia. As reported by others, K1 was the most variable gene, with up to 16% variation at the nucleotide sequence level and up to 32% variation at the amino acid sequence level. Despite this extensive sequence variation, the K1 amino acid sequence contained 14 conserved cysteine sites, suggesting a conserved tertiary structure. gB and gH sequences were highly conserved, in most cases differing by <0.6% in pairwise comparisons. K1 was the most useful gene for strain discrimination, but the other genes enabled the discrimination of strains with identical K1 sequences. Individuals from diverse geographic locations were infected with four different HHV-8 genotypes; strains did not strictly segregate by continent of origin. The majority of HHV-8 strains from the United States and Europe were relatively closely related, whereas some strains identified from Uganda and Australia were phylogenetically distant. Genotype I strains were the most common and were found on three continents. Identical sequences were found in specimens obtained from different body sites and at different times from the same individual.

AIDS-Related Opportunistic Infections↗

Parkinsonian tremor and simplification in network dynamics.

We explore the behavior of richly connected inhibitory neural networks under parameter changes that correspond to weakening of synaptic efficacies between network units, and show that transitions from irregular to periodic dynamics are common in such systems. The weakening of these connections leads to a reduction in the number of units that effectively drive the dynamics and thus to simpler behavior. We hypothesize that the multiple interconnecting loops of the brain's motor circuitry, which involve many inhibitory connections, exhibit such transitions. Normal physiological tremor is irregular while other forms of tremor show more regular oscillations. Tremor in Parkinson's disease, for example, stems from weakened synaptic efficacies of dopaminergic neurons in the nigro-striatal pathway, as in our general model. The multiplicity of structures involved in the production of symptoms in Parkinson's disease and the reversibility of symptoms by pharmacological and surgical manipulation of connection parameters suggest that such a neural network model is appropriate. Furthermore, fixed points that can occur in the network models are suggestive of akinesia in Parkinson's disease. This model is consistent with the view that normal physiological systems can be regulated by robust and richly connected feedback networks with complex dynamics, and that loss of complexity in the feedback structure due to disease leads to more orderly behavior.

Humans↗

Quantitative analysis of rapid pointing movements in Cree subjects exposed to mercury and in subjects with neurological deficits.

To quantify rapid and precise proximo-distal movements, we have developed a simple system (eurythmokinesimeter or EKM) which requires the subject to touch alternately the center of proximal and distal targets with a stylus. Ninety-six participants, including 30 controls subjects, 36 Cree subjects exposed to mercury, 21 subjects with Parkinson disease, 6 with presumed cerebellar deficit, and 3 with essential tremor, participated in the study. A total of nine measures, including precision, imprecision, contact duration, unsureness, tremor, transit time, irregularity, speed, and Fitts' constant, were calculated. Test-retest reliability was above 0.8 for most measures and above 0.9 for many measures. Correlations between measures and number of outliers with respect to the control group distribution for each measure were used to reduce the set of measures to five (i.e., precision, imprecision, tremor, Fitts' constant, and irregularity). An ANOVA on the three largest groups generated significant results for tremor, Fitts' constant, and irregularity between the Cree and the control subjects and on Fitts' constant and irregularity between the subjects with Parkinson's disease and the control subjects. Three subgroups of the same mean age composed of six subjects each were selected. One was composed of Cree subjects with the highest level of mercury exposure, another with Cree subjects having a low level of mercury exposure, and a third with control subjects. An ANOVA on these three groups revealed a significant difference between both groups of Cree subjects and the control group for Fitts' constant and irregularity. These preliminary results suggest that the EKM system is able to discriminate the performance of different groups of subjects.

Analysis of Variance↗