Search PubMed⌕ Search

Biomedical subjects

R E Sterba

Publications and source records attributed to R E Sterba.

2 recordsLinked to original sources

Outer membrane monolayer domains from two-dimensional surface scanning resistance measurements.

Cellular plasma membranes have domains that are defined, in most cases, by cytoskeletal elements. The outer half of the bilayer may also contain domains that organize glycosylphosphatidylinositol (GPI)-linked proteins. To define outer membrane barriers, we measured the resistive force on membrane bound beads as they were scanned across the plasma membrane of HEPA-OVA cells with optical laser tweezers. Beads were bound by antibodies to fluorescein-phosphatidylethanolamine (Fl-PE) or to the class I major histocompatibility complex (MHC class I) Qa-2 (a GPI-anchored protein). Two-dimensional scans of resistive force showed both occasional, resistive barriers and a velocity-dependent, continuous resistance. At the lowest antibody concentration, which gave specific binding, the continuous friction coefficient of Qa-2 was consistent with that observed by single-particle tracking (SPT) of small gold particles. At high antibody concentrations, the friction coefficient was significantly higher but decreased with increasing temperature, addition of deoxycholic acid, or treatment with heparinase I. Barriers to lateral movement (>3 times the continuous resistance) were consistently observed. Elastic barriers (with elastic constants from 1 to 20 pN/microm and sensitive to cytochalasin D) and small nonelastic barriers (<100 nm) were specifically observed with beads bound to the GPI-linked Qa-2. We suggest that GPI-linked proteins interact with transmembrane proteins when aggregated by antibody-coated beads and the transmembrane proteins encounter cytoplasmic barriers to lateral movement. The barriers to lateral movement are dynamic, discontinuous, and low in density.

Biological Transport↗

Basic laser tweezers.

The basic information has been provided here for designing and building a laser tweezers system for force measurements. If force measurements are not required, then the considerations about the analysis system, a fine piezo stage, and stability are less important. For the initial alignment and characterization of the system, red blood cells provide an easily trapped sample. For a difficult test sample, the smaller latex beads (0.15-0.3 micron in diameter) are stable and easy to obtain. Anyone setting up laser tweezers is encouraged to see a working tweezers system and to compare samples with that system. Everyone has a different background, and there may be aspects critical for you that have not been discussed here. More sophisticated systems are described later in this book.

Image Processing, Computer-Assisted↗