Search PubMed⌕ Search

Biomedical subjects

R E Kerber

Publications and source records attributed to R E Kerber.

At least 55 records · Page 3Linked to original sources

Direct current shocks to the heart generate free radicals: an electron paramagnetic resonance study.

OBJECTIVES: We sought to demonstrate that direct current (DC) shocks to the heart generate free radicals. BACKGROUND: Although it is a lifesaving maneuver, defibrillation is known to have myocardial toxicity. The mechanism of this toxicity is unknown. If DC shocks generate free radicals, free radicals could be a mechanism of myocardial injury. METHODS: In a canine model, DC shocks of 10 to 100 J were delivered to the epicardium of both beating and fibrillating hearts, and 200-J transthoracic shocks were administered in dogs with beating hearts. Ascorbate free radical (AFR) concentration was measured in arterial blood and blood continuously withdrawn from the coronary sinus. In some dogs, the antioxidant enzymes superoxide dismutase (15,000 U/kg) and catalase (55,000 U/kg) (SOD/Cat) were administered before shocks. RESULTS: Ascorbate free radicals were generated by DC shocks. A peak AFR increase of 14 +/- 2% (mean +/- SEM) was seen 5 to 6 min after 100-J epicardial shocks. A peak AFR increase of 7 +/- 5% occurred after transthoracic shocks. There was a significant linear relation between the shock energy and peak percent AFR increase: %AFR increase = 0.18 (Shock energy) + 2.9 (r = 0.73, p < 0.0001). Shocks delivered to hearts in ventricular fibrillation (30 s) resulted in generation of AFR equal to but not greater than that observed during similar shocks delivered to beating hearts in sinus rhythm. Multiple successive shocks (100 J delivered twice or five times) did not result in a greater AFR increase than single 100-J shocks, indicating that peak, not cumulative, energy is the principal determinant of AFR increase. Animals receiving SOD/Cat before shock administration showed significant attenuation of the AFR increase. CONCLUSIONS: Direct current epicardial and transthoracic shocks generate free radicals; antioxidant enzymes reduce the free radical generation by shocks.

Animals↗

Transthoracic cardioversion of atrial fibrillation and flutter: standard techniques and new advances.

Direct current electric shocks have been used to terminate atrial arrhythmias (cardioversion) in humans since the 1960s. The likelihood of successful cardioversion and maintenance of sinus rhythm is increased if the left atrium is not markedly enlarged and fibrotic, if there is no marked left atrial hypertension (e.g., mitral stenosis), and if the arrhythmia is not long-standing. To minimize the risk of thromboembolic phenomena, therapeutic anticoagulation should be established for at least 3 weeks before and for 4 weeks after cardioversion; coumadin is usually used for this purpose. A more recent approach uses transesophageal echocardiography to demonstrate the absence of thrombi in the left atrium and left atrial appendage. If no thrombi are evident, 48 hours of heparin anticoagulation may be adequate prior to cardioversion. Anticoagulation is still required after cardioversion. Quinidine and digitalis, singly or in combination, are frequently used to achieve and maintain sinus rhythm in association with cardioversion. For the procedure itself, traditional hand-held paddle electrodes or self-adhesive electrode pads may be used; the apex-anterior and anterior-posterior positions are equally effective. Gel couplants and firm pressure should always be used with hand-held paddles to reduce transthoracic impedance and maximize current flow. Electrodes should be widely separated to avoid shunting of current along the chest wall between electrodes. Generally, electrodes should be large in size; small "pediatric" electrodes should only be used in infants < 1 year of age (< 10 kg). Shocks should always be synchronized to the R wave to avoid the vulnerable period and the inadvertent induction of ventricular fibrillation. Initial shocks for atrial fibrillation should begin at 100 J; atrial flutter generally requires a smaller shock (initial shocks at 50 J). Effective anesthesia, not merely sedation, is required to achieve amnesia and avoid pain. Exciting new developments in defibrillation and cardioversion have occurred. It is now understood that excessive energy and current may induce cardiac damage, and recent studies suggest such damage may be mediated in part by free radicals. New shock waveforms, such as biphasic and multiphasic waveforms from multiple encircling electrodes, may be superior to the standard damped sinusoidal waveform.

Animals↗

Transthoracic defibrillation: importance of avoiding electrode placement directly on the female breast.

OBJECTIVES: This study sought to determine the effect on transthoracic impedance of placement of defibrillation electrodes on the female breast versus adjacent to or under the breast. BACKGROUND: Transthoracic impedance is a major determinant of transthoracic current flow in defibrillation. For a given energy setting, a high transthoracic impedance reduces current flow and may adversely affect the ability of electric shocks to accomplish defibrillation. We hypothesized that the increased interelectrode tissue associated with placement of the apex defibrillation electrode on the female breast would result in increased transthoracic impedance compared with electrode placement lateral to or under the breast. METHOD: Transthoracic impedance was measured noninvasively by passing a 5-V, 31.25-kHz square wave current through the chest and comparing the low level current flow to known references. We measured transthoracic impedance associated with three different apex defibrillation electrode positions--on the breast, under the breast and lateral to the breast--in 25 women (brassiere size 34A to 48C, 25 to 75 years old, body weight 128 to 328 lb [58 to 148 kg] and 2 men. The measurements were taken with a modified defibrillator that accurately predicts transthoracic impedance without delivering an actual shock. The measurement sequence was random. RESULTS: The average measured transthoracic impedance with placement of the apex defibrillation electrode on the breast was 95 +/- 25 ohms (mean +/- SD), under the breast 84 +/- 17* ohms and lateral to the breast 83 +/- 20* ohms (asterisk indicates p < 0.01 vs. on the breast by analysis of variance). The study cohort was also classified into two groups: large breasted (brassiere size > or = 40) and small breasted (brassiere size < or = 39). The measured transthoracic impedances for the large-breasted group were 112 +/- 20 ohms for on the breast, 94 +/- 13* ohms for under the breast and 98 +/- 19* ohms for lateral to the breast. For the small breasted group, the similar transthoracic impedance measurements were 81 +/- 21, 77 +/- 16 and 71 +/- 13* ohms, respectively. CONCLUSIONS: In women, placement of the apex defibrillation electrode on the breast results in higher transthoracic impedance, which will reduce current flow. We recommend placing the apex electrode lateral to or underneath the breast.

Adult↗

Prolonged coronary artery occlusion-reperfusion sequences reduce myocardial free radical production: an electron paramagnetic resonance study.

Our purpose was to determine whether prolonged myocardial ischemia attenuates free radical production after early reperfusion. Twenty-two mongrel dogs underwent left anterior descending coronary artery occlusion for 20, 40, or 60 minutes followed by 30 minutes of reperfusion. Electron paramagnetic resonance spectroscopy was used to measure ascorbate free radical in the coronary vein effluent. Ascorbate free radical production during reperfusion was significantly (p < 0.05) reduced in the dogs undergoing 60 minutes of coronary artery occlusion compared with the dogs undergoing 40 and 20 minutes of occlusion. We conclude that prolonged myocardial ischemia results in less free radical production on reperfusion than do shorter periods of ischemia followed by reperfusion.

Animals↗

Can atherosclerotic coronary arteries vasodilate? An intraoperative high-frequency epicardial echocardiographic study.

Our purpose was to evaluate the vasodilating responses of atherosclerotic coronary arteries using intraoperative high-frequency (12 MHz) epicardial echocardiography. We obtained continuous high-frequency epicardial echocardiographic recordings during surgery, and determined cross-sectional lumen area from 17 coronary arterial segments (12 patients). Nitroglycerin (100 to 400 micrograms/min) was administered intravenously to reduce mean (+/- SEM) arterial pressure 14 +/- 1.8 mm Hg. The cross-sectional arterial images were classified using 3 different parameters: arterial lumen area, percentage of the arterial wall circumference that was atherosclerotic (wall thickness > 0.7 mm), and presence of an eccentrically shaped arterial lumen (maximal/minimal luminal diameter > 1.5). Nine arterial segments had small (< 5.0 mm2) arterial lumens (1.7 +/- 0.40 mm2 [+/- SEM; range 0.6 to 3.9]). With nitroglycerin, the luminal area increased 0.8 +/- 0.28 mm2 (range 0 to 2.5), and 39 +/- 12.1% (range 0 to 117). The remaining 8 segments had larger (> 5.0 mm2) lumens (8.7 +/- 0.91 mm2 [range 5.0 to 11.9]). With nitroglycerin the luminal area increased 4.3 +/- 1.11 mm2 (range 1.4 to 11.4), and 51 +/- 10.2% (range 16 to 96). Seven arterial segments had eccentric lumens; mean maximal/minimal ratio was 1.8 +/- 0.08 (range 1.6 to 2.0). The area increased 39 +/- 7.3% (range 16 to 71) with nitroglycerin. In the 10 concentrically shaped lumens (maximal/minimal lumen diameters 1.3 +/- 0.04 [range 1.1 to 1.5]), nitroglycerin increased luminal area by 48 +/- 12.6% (range 0 to 117) (p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Artery Disease↗

Effects of beta-blockade on neurohumoral responses and neurochemical markers in pacing-induced heart failure.

We investigated neurohumoral profiles and transmitter and neuroenzyme markers of cardiac autonomic innervation in control (unpaced) dogs and three groups of dogs with pacing-induced heart failure (paced, paced + beta-adrenergic blockade, and paced + cardiac denervation). Left ventricular ejection fraction decreased significantly and to a comparable extent in all paced groups. Pacing increased plasma norepinephrine (NE); increases in NE were not attenuated but instead tended to be exaggerated by treatment with propranolol or cardiac denervation. Atrial hypertrophy occurred in all paced groups compared with the control group. However, atrial and right ventricular hypertrophy were not as pronounced in the paced plus cardiac denervation group as in the paced and paced plus propranolol groups. Pacing also depleted neuropeptide Y and NE from all heart chambers; propranolol treatment did not modify these local tissue changes. Pacing caused selective depletion of neuroenzymes predominantly in the left ventricle; again, propranolol did little to modify these changes. In this study of paced animals with experimentally maintained cardiac dysfunction, failure to modify noradrenergic responses with intrapericardial cardiac denervation suggests that noncardiac sources contribute predominantly to high plasma NE. Failure to modify neurohumoral, neuropeptide, and neuroenzyme responses with beta-antagonist suggests this treatment has little practical direct influence on sympathetic vasomotor activity or neuronal function in heart failure.

Animals↗

Overlapping sequential pulses. A new waveform for transthoracic defibrillation.

BACKGROUND: A directionally changing shock electrical vector could facilitate defibrillation by depolarizing myocytes with different orientations vis-à-vis the shock field. Such a changing vector can be achieved by a new waveform for transthoracic defibrillation: overlapping sequential pulses. Our purpose was to evaluate this waveform. METHODS AND RESULTS: Ventricular fibrillation was induced in closed-chest dogs. Single and overlapping truncated exponential waveform pulse shocks were then administered from self-adhesive chest electrodes. Single pulse (control) shocks were 7.5-millisecond duration, while the sequential overlapping pulse shocks, using two different pathways, consisted of two pulses, each 5.0-millisecond duration; the second pulse began 2.5 milliseconds after the start of the first pulse and ended 2.5 milliseconds after the end of the first pulse. Thus, the total duration of the sequential overlapping shock was 7.5 milliseconds. During the overlap phase (2.5 milliseconds), the electrical vector orientation is the summation of the individual vectors. Two different electrode placements and corresponding electrical vector orientations were studied: group 1 (n = 14), left lower chest to right upper chest (pulse 1), overlapped by right lower chest to left upper chest (pulse 2), with the sequence then reversed; and group 2 (n = 11), left chest to right chest (pulse 1) overlapped by dorsal (vertebral column) to ventral (sternum) (pulse 2) with the sequence then reversed. At voltages equivalent to energies of 50, 100, and 150 J, the sequential overlapping pulse shocks achieve higher success rates than the single pulse shocks: At the low energy, 50 J, single pulse shock success rates were 0% (group 2) and 14% (group 1), while the overlapping pulse shocks achieved success rates of 39% (group 2) and 55% (group 1) (P < .05). Similarly, at the highest energy tested, 150 J, single pulse shock success rates were 45% (group 2) and 61% (group 1), while the overlapping pulse shock success was 91% (group 2) and 95% (group 1) (P < .05). In a third group of dogs (n = 3), intracardiac plunge electrodes placed orthogonally in the septum showed that the orthogonal components of intracardiac voltage gradient change varied markedly during the three phases of the sequential overlapping shocks, demonstrating the changing direction of the net electrical vector as the shock proceeded. In a fourth group of dogs (n = 5), short-duration (2.5-millisecond) single pulse shocks were compared with longer 7.5-millisecond single pulse shocks and with the sequential overlapping pulse shocks, all at equivalent energies. Despite substantially higher current flow, the 2.5-millisecond-duration single pulse shocks were not more effective than 7.5-millisecond single pulse shocks, and both 2.5- and 7.5-millisecond duration single pulse shocks had markedly inferior success rates compared with the sequential overlapping pulse shocks. CONCLUSIONS: Sequential overlapping pulse shock waveforms facilitate defibrillation compared with single pulse shocks of the same total energy. This is due at least in part to the changing orientation of the electrical vector during the multiple pulse shock.

Animals↗