Improvement of defibrillation efficacy and quantification of activation patterns during ventricular fibrillation in a canine heart failure model.

BACKGROUND: Little is known about the effects of heart failure (HF) on the defibrillation threshold (DFT) and the characteristics of activation during ventricular fibrillation (VF). METHODS AND RESULTS: HF was induced by rapid right ventricular (RV) pacing for at least 3 weeks in 6 dogs. Another 6 dogs served as controls. Catheter defibrillation electrodes were placed in the RV apex, the superior vena cava, and the great cardiac vein (CV). An active can coupled to the superior vena cava electrode served as the return for the RV and CV electrodes. DFTs were determined before and during HF for a shock through the RV electrode with and without a smaller auxiliary shock through the CV electrode. VF activation patterns were recorded in HF and control animals from 21x24 unipolar electrodes spaced 2 mm apart on the ventricular epicardium. Using these recordings, we computed a number of quantitative VF descriptors. DFT was unchanged in the control dogs. DFT energy was increased 79% and 180% (with and without auxiliary shock, respectively) in HF compared with control dogs. During but not before HF, DFT energy was significantly lowered (21%) by addition of the auxiliary shock. The VF descriptors revealed marked VF differences between HF and control dogs. The differences suggest decreased excitability and an increased refractory period during HF. Most, but not all, descriptors indicate that VF was less complex during HF, suggesting that VF complexity is multifactorial and cannot be expressed by a scalar quantity. CONCLUSIONS: HF increases the DFT. This is partially reversed by an auxiliary shock. HF markedly changes VF activation patterns.

Analysis of Variance↗

Pacing during ventricular fibrillation: factors influencing the ability to capture.

INTRODUCTION: Recent studies showed that pacing atrial and ventricular fibrillation (VF) is possible. The studies presented here determined which parameters influence the efficacy of a pacing train to capture fibrillating ventricular myocardium. Electrode type, current strength, order of pacing trains, polarity, and VF morphology preceding the pacing trains were investigated. METHODS AND RESULTS: A 504-electrode recording plaque sutured to the right ventricle of pig hearts was used to record the activations of VF and those resulting from the pacing stimulation. Capture of VF by pacing was determined by observing an animated display of the first temporal derivative of the electrograms. A series of electrodes in a line captured the heart more frequently during VF than did a point electrode. Increasing the current strength to 10 x diastolic pacing threshold increased the incidence of capture, but increasing this strength further did not. The second or third train of 40 stimuli had greater capture rates than did the first train during the same VF episode. Anodal and cathodal unipolar, and bipolar stimulation were equally efficacious in capturing VF. VF activation during the 1-second interval preceding pacing was more organized for pacing trains that captured than those that did not. The highest incidence of capture, 46% to 61% of pacing trains, occurred with a line of electrodes at 10 x diastolic pacing threshold delivered by the second or third train. CONCLUSION: The probability of a pacing train capturing fibrillating myocardium can be influenced by the pacing protocol parameters.

Animals↗

Reduction in atrial defibrillation threshold by a single linear ablation lesion.

INTRODUCTION: This study investigated a hybrid approach to reduce the atrial defibrillation threshold (ADFT) by determining the effect of a single linear radiofrequency ablation (RFA) lesion on both the ADFT and activation patterns during atrial fibrillation (AF). METHODS AND RESULTS: In 18 open chest sheep (45 to 57 kg), coil defibrillation electrodes were placed in a superior vena cava/right ventricular configuration. AF was induced by burst pacing and maintained with acetyl beta-methylcholine (2 to 42 microL/min). ADFTs were obtained before and after a linear RFA lesion was created in the left atrium (LAL; n = 6), right atrium (RAL; n = 6), or neither atrium as a control (n = 6). In animals receiving an LAL, a 504-unipolar-electrode plaque was sutured to the LA. For animals receiving an RAL, two 504-electrode plaques were placed, one each on the LA and RA. From each plaque, activations were recorded before and after ADFT shocks, and organizational characteristics of activations were analyzed using algorithms that track individual wavefronts. In sham-treated controls, the ADFT did not change. In contrast, LAL reduced ADFT energy 29%, from 4.5 +/- 2.3 J to 3.2 +/- 2.0 J (P < 0.05). RAL reduced ADFT energy 25%, from 2.0 +/- 0.9 J to 1.5 +/- 0.7 J (P < 0.05). AF activation was substantially more organized after RFA than before RFA for both the RAL- and LAL-treated animals. CONCLUSION: A single RFA lesion in either the RA or LA reduces the ADFT in this sheep model. This decrease is associated with an increase in fibrillatory organization.

Animals↗

Critically timed auxiliary shock to weak field area lowers defibrillation threshold.

INTRODUCTION: This study tested the hypothesis that the defibrillation threshold (DFT) can be lowered by delivering a weak auxiliary shock in conjunction with a stronger primary shock to the cardiac region where the primary shock electric field is weakest. METHODS AND RESULTS: Eight swine were studied in each of two study parts. In both parts, DFTs were determined for dual shocks delivered through two electrode pairs. The biphasic primary shock was delivered through electrodes in the right ventricle and superior vena cava. The auxiliary shock was delivered through a separate electrode in the superior vena cava and a left ventricular electrode placed where the primary shock field was presumed to be weakest. In part I, a monophasic auxiliary shock of 50, 100, or 150 V was delivered either simultaneously with or 1, 20, or 40 msec before primary shock. When auxiliary shock was delivered simultaneously with or 1 msec before primary shock, DFT energy was reduced by approximately 50% compared with primary shock alone. In part II, a 150-V monophasic or biphasic auxiliary shock of either polarity was delivered 1 msec before or after primary shock. Regardless of waveform or polarity, all auxiliary shock delivered before primary shock lowered DFT energy by approximately 30% compared with primary shock alone. Depending on waveform and polarity, auxiliary shock delivered after primary shock either did not significantly change the DFT or elevated the DFT compared with primary shock alone. CONCLUSION: Application of a small auxiliary shock, just before or simultaneously with a primary shock, to the cardiac region where the primary shock field is weakest significantly lowers DFT.

Animals↗

Reentry site during fibrillation induction in relation to defibrillation efficacy for different shock waveforms.

INTRODUCTION: Unsuccessful defibrillation shocks may reinitiate fibrillation by causing postshock reentry. METHODS AND RESULTS: To better understand why some waveforms are more efficacious for defibrillation, reentry was induced in six dogs with 1-, 2-, 4-, 8-, and 16-msec monophasic and 1/1- (both phases 1 msec) 2/2-, 4/4-, and 8/8-msec biphasic shocks. Reentry was initiated by 141+/-15 V shocks delivered from a defibrillator with a 150-microF capacitance during the vulnerable period of paced rhythm (183+/-12 msec after the last pacing stimulus). The shock potential gradient field was orthogonal to the dispersion of refractoriness. Activation was mapped with 121 electrodes covering 4 x 4 cm of the right ventricular epicardium, and potential gradient and degree of recovery of excitability were estimated at the sites of reentry. Defibrillation thresholds (DFTs) were estimated by an up-down protocol for the same nine waveforms in eight dogs internally and in nine other dogs externally. DFT voltages for the different waveforms were positively correlated with the magnitude of shock potential gradient and negatively correlated with the recovery interval at the site at which reentry was induced by the waveform during paced rhythm for both internal (DFT = 1719 + 64.5VV - 11.1RI; R2 = 0.93) and external defibrillation (DFT = 3445 + 150VV - 22RI; R2 = 0.93). CONCLUSION: The defibrillation waveforms with the lowest DFTs were those that induced reentry at sites of low shock potential gradient, indicating efficacious stimulation of myocardium. Additionally, the site of reentry induced by waveforms with the lowest DFTs was in myocardium that was more highly recovered just before the shock, perhaps because this high degree of recovery seldom occurs during defibrillation due to the rapid activation rate during fibrillation.

Animals↗

Reduction of atrial defibrillation threshold with an interatrial septal electrode.

BACKGROUND: The standard lead configuration for internal atrial defibrillation consists of a shock between electrodes in the right atrial appendage (RAA) and coronary sinus (CS). We tested the hypothesis that the atrial defibrillation threshold (ADFT) of this RAA-->CS configuration would be lowered with use of an additional electrode at the atrial septum (SP). METHODS AND RESULTS: Sustained atrial fibrillation was induced in 8 closed-chest sheep with burst pacing and continuous pericardial infusion of acetyl-ss-methylcholine. Defibrillation electrodes were situated in the RAA, CS, pulmonary artery (PA), low right atrium (LRA), and across the SP. ADFTs of RAA-->CS and 4 other lead configurations were determined in random order by use of a multiple-reversal protocol. Biphasic waveforms of 3/1-ms duration were used for all single and sequential shocks. The ADFT delivered energies for the single-shock configurations were 1.27+/-0.67 J for RAA-->CS and 0. 86+/-0.59 J for RAA+CS-->SP; the ADFTs for the sequential-shock configurations were 0.39+/-0.18 J for RAA-->SP/CS-->SP, 1.16+/-0.72 J for CS-->SP/RAA-->SP, and 0.68+/-0.46 J for RAA-->CS/LRA-->PA. Except for CS-->SP/RAA-->SP versus RAA-->CS and RAA-->CS/LRA-->PA versus RAA+CS-->SP, the ADFT delivered energies of all of the configurations were significantly different from each other (P:<0. 05). CONCLUSIONS: The ADFT of the standard RAA-->CS configuration is markedly reduced with an additional electrode at the atrial SP.

Animals↗

Nonlinear changes of transmembrane potential during defibrillation shocks: role of Ca(2+) current.

Defibrillation shocks induce complex nonlinear changes of transmembrane potential (DeltaV(m)). To elucidate the ionic mechanisms of nonlinear DeltaV(m), we studied the effects of ionic channel blockers on DeltaV(m) in geometrically defined myocyte cultures. Experiments were carried out in cell strands with widths of 0.2 mm (narrow strands) and 0.8 mm (wide strands) produced using a technique of directed cell growth. Uniform-field shocks were applied across strands during the action potential (AP) plateau, and the distribution of shock-induced DeltaV(m) was measured using an optical mapping technique. Nifedipine and 4-aminopyridine were applied to inhibit the L-type calcium current (I:(Ca)) and the transient outward current (I:(to)), respectively. In control conditions, the distribution of DeltaV(m) across cell strands was highly asymmetrical with a large ratio of negative to positive DeltaV(m) (DeltaV(-)(m)/DeltaV(+)(m)) measured at the opposite strand borders. Application of nifedipine caused a large increase of DeltaV(+)(m) and a decrease of DeltaV(-)(m)/DeltaV(+)(m), indicating involvement of I:(Ca) in the asymmetrical DeltaV(m), likely as a result of the outward flow of I:(Ca) when V(m) exceeded the I:(Ca) reversal potential. DeltaV(-)(m) decreased in the narrow strands but remained unchanged in the wide strands, indicating that the changes of DeltaV(-)(m) were caused by electrotonic interaction with an area of depolarization. 4-Aminopyridine did not change DeltaV(-)(m)/DeltaV(+)(m). These results provide evidence that (1) the asymmetry of shock-induced DeltaV(m) during the AP plateau is due to outward flow of I:(Ca) in the depolarized portions of the strands, (2) I:(to) is not involved in the mechanism of DeltaV(m) asymmetry, and (3) the effects of drugs on DeltaV(m) are modulated by the tissue geometry.

4-Aminopyridine↗

Left ventricular apex ablation decreases the upper limit of vulnerability.

BACKGROUND: After shocks with an approximately 50% probability of success for the upper limit of vulnerability (ULV(50)) of strength, the first few activations appear focally on the epicardium at almost the same site at the left ventricular (LV) apex in both successful and failed induction of ventricular fibrillation (VF). We tested the hypothesis that subendocardial ablation at this early site would decrease the shock strength required for the ULV(50). METHODS AND RESULTS: Ten S1 stimuli were delivered from the right ventricular apex at a 300-ms coupling interval in 5 pigs. Biphasic shocks were delivered from right ventricular-superior vena cava electrodes after the last S1 stimulus. The ULV(50) was determined using an up/down protocol with T-wave scanning. Radiofrequency ablation was performed endocardially at the apical LV. The ULV(50) was determined again 30 minutes after ablation. To determine the importance of the ablation region, this protocol was repeated in another 5 pigs with ablation at the LV base. Delivered voltage (401+/-60 versus 323+/-50 V) and energy (11+/-3 versus 7+/-2 J) for the ULV(50) were significantly decreased after LV apex ablation by 19% and 34%, respectively. However, no difference existed in ULV(50) before and after LV base ablation. Lesions at both the LV apex and base were subendocardial and ranged from 0.8 to 1.1 cm in diameter. CONCLUSIONS: Subendocardial ablation at the apical LV markedly decreases ULV(50), which suggests that the activation originating from this postshock early site is responsible for VF initiation and that interventions to electrically silence this site can influence the outcome of VF induction by ULV shocks.

Animals↗

Pathological effects of extensive radiofrequency energy applications in the pulmonary veins in dogs.

INTRODUCTION: The long-term complications of catheter ablation within the pulmonary veins are unknown. The development of pulmonary vein stenosis has recently been described after catheter ablation to treat either chronic or paroxysmal atrial fibrillation. The purpose of this study was to examine the pathological and hemodynamic effects of radiofrequency (RF) energy application within the pulmonary veins. METHODS AND RESULTS: Right heart and transseptal catheterization were performed in 9 anesthetized mongrel dogs. The pulmonary vein ostia were cannulated and pulmonary venous pressure was measured before RF energy application in up to 4 separate pulmonary veins. Animals were euthanized at intervals of 2 to 4 weeks (n=3), 6 to 8 weeks (n=3), or 10 to 14 weeks (n=3) after ablation. Repeat catheterization before euthanasia demonstrated statistically significant differences in pulmonary capillary wedge pressure, cardiac output, pulmonary vascular resistance, and systemic vascular resistance (P<0.05) compared with the baseline. Luminal narrowing was observed in 22 of 33 pulmonary veins to which RF energy was applied. Of these, 7 were totally occluded, 7 had severe stenosis, and 8 were only minimally narrowed. Histological examination revealed intimal proliferation with organizing thrombus, necrotic myocardium in various stages of collagen replacement, endovascular contraction, and a proliferation of elastic lamina. CONCLUSIONS: Applications of RF current within the pulmonary veins may result in pulmonary vein narrowing or complete occlusion. These observations should be considered in treatment of arrhythmias originating within the pulmonary veins.

Animals↗

Ventricular defibrillation with triphasic waveforms.

BACKGROUND: It has been reported that triphasic defibrillation waveforms cause less myocardial injury than biphasic waveforms. This study compared the defibrillation thresholds (DFTs) of triphasic and biphasic waveforms. METHODS AND RESULTS: ++DFTs were determined for a transvenous lead system and a 300-microF-capacitor defibrillator. In 8 pigs (group 1), DFTs were determined for 5 triphasic waveforms with tilts of 80%, 83%, and 86% and for 1 biphasic waveform. DFTs were determined in another 8 pigs (group 2) for 2 triphasic and 4 biphasic waveforms with tilts of 43%, 49%, and 56%. In both groups, a biphasic waveform from a 140-microF-capacitor defibrillator was also evaluated, and both shock polarities were tested for each waveform. In group 1, with the 300-microF-capacitor defibrillator, the leading-edge voltage and energy stored at DFT were significantly lower for triphasic waveforms with phase-duration ratios of 50/33/17 and an anode at the right ventricular electrode for phase 1 than for biphasic waveforms (P<0.001). In group 2, the stored energy of triphasic waveforms with 56% and 49% tilt was significantly lower than that of biphasic waveforms with the same tilts for anodal but not cathodal phase 1 at the right ventricular electrode. Electrode polarity significantly affected the DFT of triphasic waveforms for both studies. CONCLUSIONS: Some 80% tilt triphasic waveforms defibrillate more efficiently than biphasic waveforms with a 300-microF-capacitor defibrillator. The triphasic waveforms for both groups were not superior to 140-microF-capacitor biphasic waveforms. The efficacy of triphasic waveforms depends on phase durations and electrode polarity.

Animals↗

Influence of postshock epicardial activation patterns on initiation of ventricular fibrillation by upper limit of vulnerability shocks.

BACKGROUND: Shocks of identical strength and timing sometimes induce ventricular fibrillation (VFI) and other times do not (NoVFI). To investigate this probabilistic behavior, a shock strength near the upper limit of vulnerability, ULV(50), was delivered to yield equal numbers of VFI and NoVFI episodes. METHODS AND RESULTS: In 6 pigs, a 504-electrode sock was pulled over the ventricles. ULV(50) was determined by scanning the T wave. S(1) pacing was from the right ventricular apex. Ten S(2) shocks of approximate ULV(50) strength were delivered at the same S(1)-S(2) coupling interval. Intercycle interval (ICI) and wave front conduction time (WCT) were determined for the first 5 postshock cycles. ICI and the WCT of cycle 1 were not different for VFI versus NoVFI episodes (P=0.3). Beginning at cycle 2, ICI was shorter and WCT was longer for VFI than NoVFI episodes (P<0.05). CONCLUSIONS: The first cycle after shocks of the same strength (ULV(50)) delivered at the same time has the same activation pattern regardless of shock outcome. During successive cycles, however, a progressive decrease in ICI and increase in WCT occur during VFI but not NoVFI episodes. These findings suggest shock outcome is (1) deterministic but exquisitely sensitive to differences in electrophysiological state at the time of the shock that are too small to detect or (2) probabilistic and not determined until after the first postshock cycle.

Animals↗

Pacing after shocks stronger than the upper limit of vulnerability: impact on fibrillation induction.

BACKGROUND: After upper-limit-of-vulnerability (ULV) shocks of the same strength and coupling interval (CI) during the T wave, (1) the epicardial activation pattern (EAP) for the first postshock cycle is indistinguishable between shocks that do (VF) and do not (NoVF) induce ventricular fibrillation (VF) and (2) >/=3 cycles in rapid succession always occur during VF but not during NoVF episodes. To study the role of these rapid cycles, rapid pacing was performed after a shock stronger than the ULV that by itself did not induce rapid cycles and VF. METHODS AND RESULTS: A 504-electrode sock was sutured to the heart in 6 pigs to map EAPs. The S2 shock strength and S1-S2 CI at the ULV were determined by T-wave scanning with an up/down protocol. Ten shocks 50 to 100 V above the ULV (aULV) were delivered at the same S1-S2 CI to confirm that VF was not induced. Then, the postshock interval after aULV shocks was scanned with an S3 pacing stimulus from the LV apex until the shortest S2-S3 CI that captured was reached. This was repeated for S4, S5, etc, until VF was induced. To induce VF, 3 pacing stimuli (S3-S5) with progressively shorter CIs were required; S3 or S3, S4 never induced VF. After cycle S5, which induced VF, 2 EAP types occurred: focal (74%) and reentrant (26%). CONCLUSIONS: At least 3 cycles with short CIs are necessary for VF induction after aULV shocks. Cycles S3-S4 may create the substrate for cycle S5 to initiate VF.

Animals↗

Prevention of high incidence of neurally mediated ventricular arrhythmias by afferent nerve stimulation in dogs.

BACKGROUND: This study tested the hypothesis that the high incidence of ventricular arrhythmias caused by hypothalamic stimulation during acute myocardial ischemia could be attenuated by afferent nerve stimulation and investigated the cardiac mechanisms for those effects. METHODS AND RESULTS: In 18 anesthetized dogs, stimulating electrodes were implanted in the hypothalamus and in the isolated left peroneal nerve. The chest was opened and approximately 100 plunge needles were inserted into the ventricles for 3-D activation mapping. Each animal underwent 4 episodes of 2.5 minutes of acute myocardial ischemia. The first and fourth episodes served as controls. During the second and third episodes, animals received either hypothalamic stimulation, peroneal nerve stimulation, or both. Hypothalamic stimulation significantly increased the incidence of ventricular arrhythmias. This high incidence was reduced 34% by simultaneous stimulation of the hypothalamus and peroneal nerve. 3-D mapping showed a focal origin for all ventricular arrhythmias. Hypothalamic stimulation increased the number of arrhythmic beats and decreased the coupling interval between each arrhythmic beat and the preceding beat. These effects were reduced by peroneal nerve stimulation. CONCLUSIONS: Alteration in autonomic tone by hypothalamic stimulation causes a high incidence of ventricular arrhythmias during acute myocardial ischemia that can be decreased by afferent nerve stimulation.

Acute Disease↗

Using an artificial neural network to detect activations during ventricular fibrillation.

Ventricular fibrillation is a cardiac arrhythmia that can result in sudden death. Understanding and treatment of this disorder would be improved if patterns of electrical activation could be accurately identified and studied during fibrillation. A feedforward artificial neural network using backpropagation was trained with the Rule-Based Method and the Current Source Density Method to identify cardiac tissue activation during fibrillation. Another feedforward artificial neural network that used backpropagation was trained with data preprocessed by those methods and the Transmembrane Current Method. Staged training, a new method that uses different sets of training examples in different stages, was used to improve the ability of the artificial neural networks to detect activation. Both artificial neural networks were able to correctly classify more than 92% of new test examples. The performance of both artificial neural networks improved when staged training was used. Thus, artificial neural networks may beuseful for identifying activation during ventricular fibrillation.

Diagnosis, Computer-Assisted↗

Effect of altering the left ventricular pressure on epicardial activation time in dogs with and without pacing-induced heart failure.

BACKGROUND: The influence of an increased left ventricular end-diastolic pressure (LVEDP) on the development of lethal arrhythmias in chronic heart failure is unclear. We investigated the effect of chronic and acute LVEDP increase on the epicardial activation time of sinus (SB) and paced (PB) beats. METHODS: Six dogs underwent rapid ventricular pacing at 220-280[emsp4 ]beats/min for 6-14 weeks for induction of heart failure. On the study day, baseline (ba) LVEDP was determined for the surviving heart failure animals (HF-ba), and for seven control animals (C-ba). The epicardial activation time (EAT, time between the earliest and latest epicardial activation) for five consecutive SB and five ventricular PB during the baseline hemodynamic state were recorded using a 504 electrode mapping-sock. In the control animals a 2-litre volume (vl) was infused over 10[emsp4 ]min to acutely increase the LVEDP (C-vl) to a level comparable to the chronic increased LVEDP of the HF-ba. The same volume challenge was performed in two HF animals (HF-vl) and the EAT for SB and PB was redetermined. RESULTS: Three of six HF animals died during induction of heart failure. In the three remaining HF animals, chronic LVEDP increased from 6+/-1 to 17+/-10.8[emsp4 ]mmHg (P=0.07), EAT for SB increased by 68 % compared to control animals (HF-ba vs. C-ba, P<0.05). In contrast, in the control animals the acute rise in LVEDP from 6.8+/-4.5 to 14.7+/-6.2 mmHg P<0.05), shortened the EAT for SB (C-ba vs. C-vl, P<0.05). A similar decrease in EAT for SB caused by acute volume load was seen in the HF animals, but did not reach significance due to the small sample size (one of the three remaining HF animals died of spontaneous ventricular fibrillation before the volume load). Chronic LVEDP elevation significantly prolonged the EAT for PB from 72+/-11 to 120+/-31[emsp4 ]ms (C-ba vs. HF-ba) while acute LVEDP increase had no significant effect on EAT for PB. CONCLUSION: Chronic HF increases LVEDP and prolongs EAT, while an acute increase in LVEDP shortens the EAT for sinus beats. A prolongation of EAT in heart failure may make the heart more susceptible to ventricular arrhythmias and electromechanical dissociation.

Acute Disease↗

Electrode impedance: an indicator of electrode-tissue contact and lesion dimensions during linear ablation.

Pre-ablation impedance was evaluated for its ability to detect electrode-tissue contact and allow creation of long uniform linear lesions with a multi-electrode ablation catheter. The study consisted of 2 parts, both of which used the in vivopig thigh muscle model. In part 1, a 7 Fr. multi-electrode catheter was held in 3 electrode-tissue contact conditions: (1) non-contact; (2) light contact with a 30g downward force; and (3) tight contact with a 90g downward force. Impedances were measured in unipolar, modified unipolar and bipolar configurations using a source with frequencies from 100Hz to 500kHz. Compared with non-contact, the impedance increased 35 +/- 22 % with 30g contact pressure and 68 +/- 40% when the contact pressure was increased to 90g across the range of frequencies studied. In part 2, the same catheter was held against the tissue with different forces. Pre-ablation impedance was measured using a 10kHz current. Phased radiofrequency energy was applied to the 5 electrodes simultaneously using 10W power at each electrode for 120s. A total of 32 linear lesions were created. The lesion dimensions correlated with pre-ablation impedance. A unipolar impedance > or = 190 Omega indicates 95% possibility to create a uniform linear lesion of at least 3mm depth with our ablation system. We conclude that pre-ablation impedance may be a useful indicator for predicting electrode-tissue contact and the ability to create a continuous and transmural linear lesion with a multi-electrode catheter.

Analysis of Variance↗

Continuous telemetry from a chronic canine model of sudden cardiac death.

INTRODUCTION: We sought to develop a continuously telemetered animal model of sudden cardiac death (SCD) to study the role of existing infarcts and acute ischemia in fatal arrhythmias. METHODS AND RESULTS: A telemetry system capable of recording eight channels of electrophysiologic data continuously and chronically has been developed. To demonstrate the use of this technology in an animal model of sudden death, 12 anesthetized dogs were instrumented with eight electrodes located in endocardium of the right side of the heart, epicardium of the left ventricle (LV), or in the subcutaneous tissues. The left anterior descending (LAD) coronary artery was occluded for 90 minutes and reperfused to produce LV infarction. A copper wire was placed in the left circumflex (LCX) coronary artery to cause intimal injury in a second arterial bed. The telemetry unit recorded deaths in seven animals between 19 to 64 hours after surgery. Five animals that did not experience SCD by the fifth postoperative day served as controls. There were three modes of SCD: complex ventricular ectopy that degenerated into ventricular fibrillation (VF, n = 4); normal sinus rhythm that suddenly degenerated into VF (n = 1); and bradycardia (RR intervals >1,000 msec) that lasted >3 minutes and preceded VF (n = 2). ST segment changes were significantly greater in the LCX-bed electrograms for tachyarrhythmic compared to bradyarrhythmic deaths (mean +/- SD; 4.0 +/- 3.4 mV and 0.2 +/- 0.8 mV, respectively). Fast Fourier transform showed the peak frequency of VF 10 seconds after onset was significantly higher in the five dogs with initial tachyarrhythmias compared with the VF that followed profound bradycardia (6.5 +/- 3.1 Hz and 3.7 +/- 0.6 Hz, respectively). Computer-assisted planimetry of postmortem heart slices revealed that infarcts in the two dogs with bradycardic events were larger (19.7% +/- 2.2% of the LV and septal mass) than in the five dogs with tachyarrhythmias (7.7% +/- 2.4%) or in the five control dogs (11.9% +/- 8.1%). CONCLUSION: It is possible to record via telemetry the events leading to SCD in an animal model. Continuous telemetry monitoring demonstrated that both tachyarrhythmias and bradyarrhythmias ultimately resulted in VF in an animal model of SCD. Animals with tachyarrhythmic deaths had greate ischemia in the LCX bed, smaller preexisting infarcts, and higher VF peak frequency than animals with bradyarrhythmic deaths.

Animals↗