Engineering microstructures to evaluate and replace trabecular bone.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R E Guldberg.
Explore the source record for details and available documents.
Poly(vinyl alcohol) (PVA) hydrogels have been proposed as promising biomaterials to replace diseased or damaged articular cartilage. A critical barrier to their use as load-bearing tissue replacements is a lack of sufficient mechanical properties. The purpose of this study was to characterize the functional compressive and shear mechanical properties of a novel PVA hydrogel. Two formulations of the biomaterial were tested, one with a lower water content (75% water), and the other with higher water content (80% water). The compressive tangent modulus varied with biomaterial formulation and was found to be statistically strain magnitude and rate dependent. Over a strain range of 10-60%, the compressive modulus increased from approximately 1-18 MPa, which is within the range of the modulus of articular cartilage. The shear tangent modulus (0.1-0.4 MPa) was also found to be strain magnitude dependent and within the range of normal human articular cartilage, but it was not statistically dependent on strain rate, This behavior was attributed to the dominance of fluid flow and related frictional drag on the viscoelastic behavior. Compressive failure of the hydrogels was found to occur between 45 and 60% strain, depending on water content.
A finite element method to simulate the formation of an interconnected trabectular bone microstructure oriented with respect to applied in vivo mechanical forces is introduced and quantitatively compared to experimental data from a hydraulic bone chamber implant model. Randomly located 45 microm mineralized nodules were used as the initial condition for the model simulations to represent an early stage of intramembranous bone formation. Boundary conditions were applied consistent with the mechanical environment provided by the in vivo bone chamber model. A two-dimensional repair simulation algorithim that incorporated strain energy density (SED), SED gradient, principal strain, or principal strain gradient as the local objective criterion was utilized to simulate the formation of an oriented trabecular bone microstructure. The simulation solutions were convergent, unique, and relatively insensitive to the assumed initial distribution of mineralized nodules. Model predictions of trabecular bone morphology and anisotropy were quantitatively compared to experimental results. All simulations produced structures that qualitatively resembled oriented trabecular bone. However only simulations utilizing a gradient objective criterion yielded results quantitatively similar to in vivo observations. This simulation approach coupled with an experimental model that delivers controlled in vivo mechanical stimuli can be utilized to study the relationship between physical factors and microstructural adaptation during bone repair.
Digital image-based finite element modeling (DIBFEM) has become a widely utilized approach for efficiently meshing complex biological structures such as trabecular bone. While DIBFEM can provide accurate predictions of apparent mechanical properties, its application to simulate local phenomena such as tissue failure or adaptation has been limited by high local solution errors at digital model boundaries. Furthermore, refinement of digital meshes does not necessarily reduce local maximum errors. The purpose of this study was to evaluate the potential to reduce local mean and maximum solution errors in digital meshes using a post-processing filtration method. The effectiveness of a three-dimensional, boundary-specific filtering algorithm was found to be mesh size dependent. Mean absolute and maximum errors were reduced for meshes with more than five elements through the diameter of a cantilever beam considered representative of a single trabecula. Furthermore, mesh refinement consistently decreased errors for filtered solutions but not necessarily for non-filtered solutions. Models with more than five elements through the beam diameter yielded absolute mean errors of less than 15% for both Von Mises stress and maximum principal strain. When applied to a high-resolution model of trabecular bone microstructure, boundary filtering produced a more continuous solution distribution and reduced the predicted maximum stress by 30%. Boundary-specific filtering provides a simple means of improving local solution accuracy while retaining the model generation and numerical storage efficiency of the DIBFEM technique.
Most known members of the serpin superfamily are serine proteinase inhibitors. Serpins are therefore important regulators of blood coagulation, complement activation, fibrinolysis, and turnover of extracellular matrix. Serpins form SDS-resistant complexes of 1:1 stoichiometry with their target proteinases by reaction of their P1-P1' peptide bond with the active site of the proteinases. The nature of the interactions responsible for the high stability of the complexes is a controversial issue. We subjected the complex between the serine proteinase urokinase-type plasminogen activator (uPA) and the serpin plasminogen activator inhibitor-1 (PAI-1) to proteolytic digestion under nondenaturing conditions. The complex could be degraded to a fragment containing two disulfide-linked peptides from uPA, one of which included the active site Ser, while PAI-1 was left undegraded. By further proteolytic digestion after denaturation and reduction, it was also possible to degrade the PAI-1 moiety, and we isolated a fragment containing 10 amino acids from uPA, encompassing the active site Ser, and 6 amino acids from PAI-1, including the P1 Arg. Characterization of the fragment gave results fully in agreement with the hypothesis that it contained an ester bond between the hydroxyl group of the active site Ser and the carboxyl group of the P1 Arg. These data for the first time provide direct evidence that serine proteinases are entrapped at an acyl intermediate stage in serine proteinase-serpin complexes.
Digital image-based finite element meshing is an alternative approach to time-consuming conventional meshing techniques for generating realistic three-dimensional (3D) models of complex structures. Although not limited to biological applications, digital image-based modeling has been used to generate structure-specific (i.e., non-generic) models of whole bones and trabecular bone microstructures. However, questions remain regarding the solution accuracy provided by the digital meshing approach, particularly at model or material boundaries. The purpose of this study was to compare the accuracy of digital and conventional smooth boundary models based on theoretical solutions for a two-dimensional (2D) compression plate and a 3D circular cantilever beam. For both the plate and beam analyses, the predicted solution at digital model boundaries was characterized by local oscillations, which produced potentially high errors within individual boundary elements. Significantly, however, the digital model boundary solution oscillated approximately about the theoretical solution. A marked improvement in solution accuracy was therefore achieved by considering average results within a region composed of several elements. Absolute errors for Von Mises stress averaged over the beam cross section, for example, converged to less than 4 percent, and the predicted free-end displacement of the cantilever beam was within 1 percent of the theoretical solution. Analyses at several beam orientations and mesh resolutions suggested a minimum discretization of three to four digital finite elements through the beam cross section to avoid high numerical stiffening errors under bending.
Trabecular bone adaptation adjacent to porous-coated platen implants embedded within canine distal femoral metaphyses was evaluated following 24 weeks of daily compressive loading. The in vivo experimental model delivered controlled loads to five different platen implant topologies with variations in platen shape and porous coating distribution. Adaptive changes were evaluated based on three-dimensional stereological analyses of trabecular bone architecture underneath each platen and non-destructive mechanical tests of platen construct stiffness. Fully coated cylindrical platen designs possessed the highest construct stiffness in both tension and compression. Changes in local trabecular bone morphology were also found to be significantly influenced by platen implant topology. Cylindrical platens with fully coated bottom surfaces were associated with greater decreases in trabecular bone volume and connectivity than cylindrical platens with smooth bottom surfaces or fully coated conical platens. Comparisons to site-matched contralateral control bone volumes across all platen designs indicated significant decreases in the average bone volume fraction, trabecular plate number, and connectivity within experimental samples, but no change in trabecular plate thickness. In addition, analyses of microstructural anisotropy revealed a 20 degrees or 20.2 degrees trabecular reorientation towards the axis of loading in experimental tissue. This study demonstrates that trabecular bone adaptation near porous-coated surfaces is influenced by variations in local implant topology and provides insight into specific mechanisms of implant-mediated microstructural adaptation.
A hydraulically activated bone chamber model was utilized to investigate cellular and microstructural mechanisms of mechanical adaptation during bone repair. Woven trabecular bone and fibrotic granulation tissue filled the initially empty chambers by 8 weeks postimplantation into canine tibial and femoral metaphyses. Without mechanical stimulation, active bone remodeling to lamellar trabecular bone and reconstitution of marrow elements were observed between 8 and 24 weeks. In subsequent loading studies, the hydraulic mechanism was activated on one randomly chosen side of 10 dogs following 8 weeks of undisturbed bone repair. The loading treatment applied an intermittent compressive force (18 N, 1.0 Hz, 1800 cycles/day) for durations of a few days up to 12 weeks. Stereological analysis of three-dimensional microcomputed tomography images revealed an increase in trabecular plate thickness and connectivity associated with the loaded repair tissue microstructure relative to unloaded contralateral controls. These microstructural alterations corresponded to an over 600% increase in the apparent modulus of the loaded bone tissue. A significant increase in the percentage of trabecular surfaces lined by osteoblasts immunopositive for type I procollagen after a few days of loading provided further evidence for mechanical stimulation of bone matrix synthesis. The local principal tissue strains associated with these adaptive changes were estimated to range from approximately -2000 to +3000 mustrain using digital image-based finite element methods. This study demonstrates the sensitivity of bone tissue and cells to a controlled in vivo mechanical stimulus and identifies microstructural mechanisms of mechanical adaptation during bone repair. The hydraulic bone chamber is introduced as an efficient experimental model to study the effects of mechanical and biological factors on bone repair and regeneration.
We hypothesized that early bone adaptation to well fixed porous-coated implants is influenced more by wound healing than by mechanical loading. To test this hypothesis, two groups of dogs with identical, hydraulically controlled porous-coated implants interference fit within distal femoral trabecular bone were used. One group had no load: the other had 35 N of load applied to the implants. At 5 weeks after surgery, the resulting adaptation of bone around the implants was quantified on a cellular basis by cytochemical analysis of type-I procollagen synthesis and on a structural basis using three-dimensional micro-computed tomography imaging. The percentage of trabecular surfaces covered by osteoblasts expressing type-I procollagen was significantly increased in bone surrounding the implant in both groups compared with contralateral control bone tissue. There was no difference between the groups with no load or 35 N of load. In addition, measures of trabecular bone structure did not differ significantly between the load and no-load groups. Taken together, these results suggest that wound healing plays a much greater role in the early response of bone to well fixed porous-coated implants than does mechanical stimulus.