Search PubMed⌕ Search

Biomedical subjects

R E Carson

Publications and source records attributed to R E Carson.

At least 19 recordsLinked to original sources

PET imaging of 5-HT1A receptor binding in patients with temporal lobe epilepsy.

BACKGROUND: Activation of central serotonin (5-HT)1A receptors, found in high density in brainstem raphe, hippocampus, and temporal neocortex, exerts an anticonvulsant effect in various experimental seizure models. To test the hypothesis that 5-HT1A receptor binding is reduced in human epileptic foci, PET imaging was performed using the radioligand [18F]trans-4-fluoro-N-2-[4-(2-methoxyphenyl)piperazin-1-yl]ethyl]-N-(2-pyridyl)cyclohexanecarboxamide ([18F]FCWAY), a selective 5-HT1A receptor antagonist, in patients with temporal lobe epilepsy and normal controls. METHODS: MRI and PET were performed using [15O]water and [18F]FCWAY in 10 controls and in 12 patients with temporal lobe epilepsy confirmed on ictal video-EEG; patients also underwent [18F]fluorodeoxyglucose PET. Using quantitative PET image analysis, regional values were obtained for [18F]FCWAY volume of distribution (V), cerebral blood flow (CBF), and glucose cerebral metabolic rate (CMRglc). Hippocampal volume (HV) was also measured with MRI. [18F]FCWAY V PET and MR measures were compared within patients and controls using paired t-tests; grouped comparisons were made with two sample t-tests. RESULTS: Lower [18F]FCWAY V was found ipsilateral than contralateral to the epileptic focus in inferior medial (IMT) and lateral (ILT) temporal regions of patients (ILT 47.4 +/- 6.1 vs 61.8 +/- 6.1, p < 0.01; IMT 52 +/- 4.6 vs 67.0 +/- 6.0, p < 0.01). [18F]FCWAY V was 29% lower in raphe and 34% lower in the ipsilateral thalamic region of patients than controls. In ILT, mean [18F]FCWAY V asymmetry index (AI) was significantly greater than mean CBF and mean CMRglc AI. Mean [18F]FCWAY V AI in IMT was greater than mean HV AI, but the difference was not significant. CONCLUSION: These findings support the hypothesis of reduced serotonin receptor binding in temporal lobe epileptic foci.

Adult↗

Noninvasive estimation of the aorta input function for measurement of tumor blood flow with.

Quantitative measurement of tumor blood flow with [15O]water can be used to evaluate the effects of tumor treatment over time. Since quantitative flow measurements require an input function, we developed the profile fitting method (PFM) to measure the input function from positron emission tomography images of the aorta. First, a [11C]CO scan was acquired and the aorta region was analyzed. The aorta diameter was determined by fitting the image data with a model that includes scanner resolution, the measured venous blood radioactivity concentration, and the spillover of counts from the background. The diameter was used in subsequent fitting of [15O]water dynamic images to estimate the aorta and background radioactivity concentrations. Phantom experiments were performed to test the model. Image quantification biases (up to 15%) were found for small objects, particularly for those in a large elliptical phantom. However, the bias in the PFM concentration estimates was much smaller (2%-6%). A simulation study showed that PFM had less bias and/or variability in flow parameter estimates than an ROI method. PFM was applied to human [11C]CO and [15O]water dynamic studies with left ventricle input functions used as the gold standard. PFM parameter estimates had higher variability than found in the simulation but with minimal bias. These studies suggest that PFM is a promising technique for the noninvasive measurement of the aorta [15O]water input function.

Aorta↗

Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies.

Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo targets. Mixture activities at the end of bombardment were determined with a calibrated high purity germanium detector. The activity fractions of the greatest mixture impurities relative to 100% for Tc-94m averaged 10.0% (Tc-94g) and 3.3% (Tc-93) for enriched targets and 10.1% (Tc-94g), 11.0% (Tc-95), 255.8% (Tc-96m), and 7.2% (Tc-99m) for natural targets. These radioisotopes have different half-lives (e.g., 52.5 min for Tc-94m, 293 min for Tc-94g), positron branching ratios (e.g., 0.72 for Tc-94m, 0.11 for Tc-94g) and gamma ray emissions for themselves and their short-lived, excited Mo daughters. This complicates estimation of injected activity with a dose calibrator, in vivo activity with PET and blood sample activity with a gamma counter. Decay correction using only the Tc-94m half-life overestimates activity and is inadequate. For this reason analytic formulas for activity estimation and decay correction of radionuclide mixtures were developed. Isotope-dependent sensitivity factors for a PET scanner, dose calibrator, and gamma counter were determined using theoretical sensitivity models and fits of experimental decay curves to sums of exponentials with fixed decay rates. For up to 8 h after the end of bombardment with activity from enriched and natural Mo targets, decay-corrected activities were within 3% of the mean for three PET studies of a uniform cylinder, within 3% of the mean for six dose calibrator decay studies, and within 6% of the mean for four gamma counter decay studies. Activity estimation and decay correction for Tc-94m mixtures enable routine use of Tc-94m in quantitative PET, as illustrated by application to a canine Tc-94m sestamibi study.

Animals↗

Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment.

UNLABELLED: Tumor detection depends on the contrast between tumor activity and background activity and on the image noise in these 2 regions. The lower the image noise, the easier the tumor detection. Tumor activity contrast is determined by physiology. Noise, however, is affected by many factors, including the choice of reconstruction algorithm. Previous simulation and phantom measurements indicated that the ordered-subset expectation maximization (OSEM) algorithm may produce less noisy images than does the usual filtered backprojection (FBP) method, at equivalent resolution. To see if this prediction would hold in actual clinical situations, we quantified noise in clinical images reconstructed with both OSEM and FBP. METHODS: Three patients (2 with colon cancer, 1 with breast cancer) were imaged with FDG PET using a "gated replicate" technique that permitted accurate measurement of noise at each pixel. Each static image was acquired as a gated image sequence, using a pulse generator with a 1-s period, yielding 40 replicate images over the 10- to 15-min imaging time. The images were or were not precorrected for attenuation and were reconstructed with both FBP and OSEM at comparable resolution. From these data, images of pixel mean, SD, and signal-to-noise ratio (S/N) could be produced, reflecting only noise caused by the statistical fluctuations in the emission process. RESULTS: Noise did not vary greatly over each FBP image, even when image intensity varied greatly from one region to the next, causing S/N to be worse in low-activity regions than in high-activity regions. In contrast, OSEM had high noise in hot regions and low noise in cold regions. OSEM had a much better S/N than did FBP in cold regions of the image, such as the lungs (in the attenuation-corrected images), where improvements in S/N averaged 160%. Improvements with OSEM were less dramatic in hotter areas such as the liver (averaging 25% improvement in the attenuation-corrected images). In very hot tumors, FBP actually produced higher S/Ns than did OSEM. CONCLUSION: We conclude that OSEM reconstruction can significantly reduce image noise, especially in relatively low-count regions. OSEM reconstruction failed to improve S/N in very hot tumors, in which S/N may already be adequate for tumor detection.

Algorithms↗

Opiate receptor avidity is increased in rhesus monkeys following unilateral optic tract lesion combined with transections of corpus callosum and hippocampal and anterior commissures.

Opiate receptor avidity (B(max)'/K(D)) was measured in four rhesus monkeys following unilateral lesioning of the optic tract combined with transection of the corpus callosum and the hippocampal and anterior commissures depriving one hemisphere of visual input (Tract and Split), two animals with transection of commissures only (Split), and nine healthy monkeys with positron emission tomography (PET) and 6-deoxy-6-beta-[(18)F]fluoronaltrexone (cyclofoxy, CF), a mu- and kappa-opiate receptor antagonist. Opiate receptor avidity was found to be significantly higher in the Tract and Split animals, only, bilaterally, throughout the lateral cortex and in the cingulate and posterior putamen (41-117%). Ipsilateral changes were consistently greater than those contralateral, but this asymmetry was of statistical significance only in the parietal and occipital cortices. Cyclofoxy avidity was decreased in the medial cortex of both the Tract and Split and Split animals ( approximately 25%). The results suggest that opiate pathways undergo extensive alteration in response to changes in brain functional activities brought about through hemispheric visual deprivation.

Animals↗

Opiate receptor avidity in the thalamus is sexually dimorphic in the elderly.

Opiate receptor avidity (B(')(max)/K(D)), was measured in the subcortex of nine females (five healthy subjects, four Alzheimer patients) and 15 males (seven healthy subjects, eight Alzheimer patients), 51-75 years of age, with the opiate receptor antagonist 6-deoxy-6-beta-[(18)F]fluoronaltrexone (cyclofoxy, CF) and a positron emission tomograph. CF avidity was 27.5% less in the thalamus of healthy women compared to healthy men and 48.5% less in Alzheimer disease female patients compared to male patients.

Aged↗

PET evaluation of [(18)F]FCWAY, an analog of the 5-HT(1A) receptor antagonist, WAY-100635.

We synthesized [(18)F]FCWAY, an analog of [carbonyl-(11)C]WAY-100635 ¿[(11)C]N-(2-(1-(4-(2-methoxyphenyl)-piperazinyl)ethyl))-N-(2-(pyridi nyl))cyclohexanecarboxamide¿, by replacing the cyclohexanecarbonyl group acid with a trans-4-fluorocyclohexanecarbonyl group (FC). Control and preblocking studies were performed in anesthetized monkeys. Plasma radioactive metabolite analysis showed the presence of [(18)F]FC and [(18)F]fluoride. Tissue time-radioactivity curves were corrected for metabolite contamination based on separate positron-emission tomography studies of these two labeled metabolites. Analysis using a two-tissue compartment model gave distribution volume (V) estimates (mL/mL) ranging from 33 in frontal cortex to 4 in cerebellum. Preblocking data showed uniform V of 2-3 mL/mL. These studies demonstrate that [(18)F]FCWAY has very similar kinetic characteristics to [(11)C]WAY-100635.

Animals↗

PET physiological measurements using constant infusion.

A wide range of study designs can be used with positron emission tomography methods to provide quantitative measurements of physiological parameters. While bolus injection of tracer is the conventional approach, use of combined bolus plus constant infusion provides a number of advantages for receptor-binding tracers. Of recent interest is the use of this approach to dynamically follow the displacement of tracer during in vivo changes in neurotransmitter concentrations. This paper provides an overview of the tradeoffs in using bolus/infusion methods versus conventional bolus injection for receptor binding studies.

Brain↗

The suitability of [11C]-alpha-methyl-L-tryptophan as a tracer for serotonin synthesis: studies with dual administration of [11C] and [14C] labeled tracer.

The tracer [11C]-alpha-methyl-L-tryptophan (alphaMTP) has been used to measure brain serotonin synthesis rates with positron emission tomography (PET). To address questions about the accuracy of the kinetic model, [14C]alphaMTP was used to directly measure conversion to [14C]-alpha-methyl-serotonin (alphaM5HT) in monkeys that had been previously studied with PET and [11C]alphaMTP. Four male, fasted, isoflurane-anesthetized rhesus monkeys were studied with [11C]alphaMTP and PET. Immediately after the initial 3-hour scan, a second dose of [11C]alphaMTP was coinjected with 1 mCi of [14C]alphaMTP, and additional PET data were collected. Approximately 90 minutes after the second alphaMTP administration, the animals were killed with an overdose of phenobarbital, and brain samples from 21 regions were taken and analyzed by HPLC. Minimal conversion of alphaMTP to alphaM5HT occurred; HPLC analysis of 14C radioactivity showed that greater than 96% of the total counts were in fractions corresponding to the alphaMTP peak. Brain concentrations of serotonin, tryptophan, 5-hydroxyindole-3-acetic acid, and alphaMTP also were determined fluorometrically using external quantification. Patlak plots generated from PET images acquired over 3 hours showed no time period of linear increase, and final slopes were not significantly different from zero, consistent with the finding of minimal conversion to [14C]alphaM5HT. These data indicate that in the 3-hour period after injection, [11C]alphaMTP is acting predominantly as a tracer of tryptophan uptake, not serotonin synthesis.

Animals↗

Kinetic analysis of the 5-HT2A ligand [11C]MDL 100,907.

The goal of this study was to develop a suitable kinetic analysis method for quantification of 5-HT2A receptor parameters with [11C]MDL 100,907. Twelve control studies and four preblocking studies (400 nmol/kg unlabeled MDL 100,907) were performed in isoflurane-anesthetized rhesus monkeys. The plasma input function was determined from arterial blood samples with metabolite measurements by extraction in ethyl acetate. The preblocking studies showed that a two-tissue compartment model was necessary to fit the time activity curves of all brain regions including the cerebellum--in other words, the need for two compartments is not proof of specific binding. Therefore, a three-tissue compartment model was used to analyze the control studies, with three parameters fixed based on the preblocking data. Reliable fits of control data could be obtained only if no more than three parameters were allowed to vary. For routine use of [11C]MDL 100,907, several simplified methods were evaluated. A two-tissue (2T') compartment with one fixed parameter was the most reliable compartmental approach; a one-compartment model failed to fit the data adequately. The Logan graphical approach was also tested and produced comparable results to the 2T' model. However, a simulation study showed that Logan analysis produced a larger bias at higher noise levels. Thus, the 2T' model is the best choice for analysis of [11C]MDL 100,907 studies.

Animals↗

Performance characteristics of the 3-D OSEM algorithm in the reconstruction of small animal PET images. Ordered-subsets expectation-maximixation.

Rat brain images acquired with a small animal positron emission tomography (PET) camera and reconstructed with the three-dimensional (3-D) ordered-subsets expectation-maximization (OSEM) algorithm with resolution recovery have better quality when the brain is imaged by itself than when inside the head with surrounding background activity. The purpose of this study was to characterize the dependence of this effect on the level of background activity, attenuation, and scatter. Monte Carlo simulations of the imaging system were performed. The coefficient of variation from replicate images, full-width at half-maximum (FWHM) from point sources and image profile fitting, and image contrast and uniformity were used to evaluate algorithm performance. A rat head with the typical levels of five and ten times the brain activity in the surrounding background requires additional iterations to achieve the same resolution as the brain-only case at a cost of 24% and 64% additional noise, respectively. For the same phantoms, object scatter reduced contrast by 3%-5%. However, attenuation degraded resolution by 0.2 mm and was responsible for up to 12% nonuniformity in the brain images suggesting that attenuation correction is useful. Given the effects of emission and attenuation distribution on both resolution and noise, simulations or phantom studies should be used for each imaging situation to select the appropriate number of OSEM iterations to achieve the desired resolution-noise levels.

Algorithms↗

Measurement of dopamine release with continuous infusion of [11C]raclopride: optimization and signal-to-noise considerations.

UNLABELLED: PET studies with [11C]raclopride provide an indirect measure of changes in synaptic dopamine. Previously, we used the bolus-plus-infusion (B/I) method to assess dopamine response from the percentage change in binding potential (deltaBP) before and after administration of amphetamine. The goal of this work is to optimize the measurement of changes in neurotransmitter with the B/I method by choosing the optimal timing for pre- and poststimulus scanning. METHODS: Two sources of variability in deltaBP were considered: within-subject and between-subject noise. A noise model based on a phantom study and human data was used to evaluate the within-subject noise. For between-subject noise, simulated time--activity curves were generated from measured [11C]raclopride input functions. Optimal timing to measure deltaBP was determined and applied to human data. RESULTS: According to the simulation study, the optimal scan times for pre-and poststimulus scans were 39-50 and 58-100 min, respectively. The optimal timing resulted in a 28% noise reduction compared with the original timing. By applying the optimal timing to human studies, the statistical significance of the difference in deltaBP between patients with schizophrenia and healthy volunteers increased from P = 0.038 to 0.012. CONCLUSION: Careful assessment of the sources of noise in receptor imaging studies can increase the sensitivity of the B/I method for the detection of biologic signals.

Adult↗

Parametric images of blood flow in oncology PET studies using [15O]water.

UNLABELLED: PET was used to measure tumor blood flow, which is potentially valuable for diagnosis and assessing the effects of therapy. To help visualize regional differences in blood flow and to improve the accuracy of region-of-interest placement, a parametric imaging approach was developed and compared with the standard region-of-interest method. METHODS: Five patients with renal cell metastases in the thorax were studied using [15O]water and dynamic PET. To assess the reproducibility of the blood flow measurements, multiple water studies were performed on each patient. Model fitting was done on a pixel-by-pixel basis using several different formulations of the standard single-compartment model. RESULTS: The tumors studied spanned a wide range of blood flows, varying from 0.4 to 4.2 mL/min/g. These values were generally high compared with those of most other tissues, which meant that the tumors could be readily identified in parametric images of flow. The different model formulations produced images with different characteristics, and no model was entirely valid throughout the field of view. Although tumor blood flow measured from the parametric images was largely unbiased with respect to a standard regional method, large errors were observed with certain models in regions of low flow. The most robust model throughout the field of view had only 1 free parameter and, compared with a regional method, gave rise to a flow bias of 0.3%+/-3.1% for tumor and 16%+/-11% for low-flow soft tissue (muscle plus fat). With this model, tumor blood flow was measured with an SD of 7.6%+/-4.0%. CONCLUSION: Parametric imaging provides a convenient way of visualizing regional changes in blood flow, which may be valuable in studies of tumor blood flow.

Blood Flow Velocity↗

Opioid receptor imaging with positron emission tomography and [(18)F]cyclofoxy in long-term, methadone-treated former heroin addicts.

Stabilized methadone-maintained former heroin addicts (MTPs) treated with effective doses of methadone have markedly reduced drug craving; reduction or elimination of heroin use; normalized stress-responsive hypothalamic-pituitary-adrenal, reproductive, and gastrointestinal function; and marked improvement in immune function and normal responses to pain, all of which are physiological indices modulated in part by endogenous and exogenous opioids directed at the mu and, in some cases, the kappa-opioid systems. This study was performed to explore opioid receptor binding in MTPs. Fourteen normal, healthy volunteers and 14 long-term MTPs in treatment for 2 to 27 years and receiving 30 to 90 mg/day of methadone were studied with positron emission tomography using tracer amounts of [(18)F]cyclofoxy, an opioid antagonist that labels mu and kappa opioid receptors. Imaging was performed in the morning, 22 h after the last dose of methadone in patients, and concurrent plasma levels of methadone were determined. Five brain regions of specific interest for addiction and pain research (thalamus, amygdala, caudate, anterior cingulate cortex, and putamen) were among the six regions of highest [(18)F]cyclofoxy binding. Specific binding of [(18)F]cyclofoxy was lower by 19 to 32% in these regions in MTPs compared with those in normal volunteers. The degree to which specific binding was lower in caudate and putamen correlated with methadone plasma levels (P <.01 and P <.05, respectively), suggesting that these lower levels of binding may be related to receptor occupancy with methadone and that significant numbers of opioid receptors may be available to function in their normal physiological roles.

Adult↗

Opiate receptor avidity is reduced bilaterally in rhesus monkeys unilaterally lesioned with MPTP.

Opiate receptor avidity (unoccupied receptor density / the receptor dissociation constant), was measured in four animals with unilateral parkinsonian symptoms following MPTP (1-methyl-4-phenyl-1,2,3, 6-tetrahydropyridine) infusions into the internal carotid of one side, and nine normal controls with positron emission tomography (PET) and 6-deoxy-6-beta-[(18)F]fluoronaltrexone (cyclofoxy, CF), a mu- and kappa-opiate receptor antagonist. PET studies of 6-[(18)F]-L-fluoro-L-3,4-dihydroxyphenylalanine ([(18)F]-DOPA) in these parkinsonian animals, although documenting the primarily unilateral nature of the lesion, also demonstrated a milder loss of dopaminergic on the side opposite the infusion. Opiate receptor avidity was found to be reduced by 20-34% in the caudate, anterior putamen, thalamus, and amygdala of these primarily unilaterally MPTP-exposed animals, bilaterally with no statistically significant differences between the two sides. The affected regions are the same as those previously demonstrated to have a 30-35% loss in clinically recovered bilaterally MPTP-lesioned animals. These findings confirm that the opiate pathway can change in response to modest decreases in basal ganglia dopamine innervation. Thus, opiate pathway adaptation is likely to contribute to the dynamic changes in basal ganglia circuits that forestall the initial clinical manifestations of Parkinson's disease. In addition, opiate pathway(s) may contribute to the treatment responsiveness and progression of the disease either directly through effects on basal ganglia function or indirectly through effects on basal ganglia plasticity.

1-Methyl-4-phenyl-1,2,3,6-tetrahydropyridine↗

Development of fluorine-18-labeled 5-HT1A antagonists.

We have synthesized five fluorinated derivatives of WAY 100635, N-{2-[4-(2-methoxyphenyl)piperazino]ethyl}-N-(2-pyridyl)cyclohe xaneca rboxamide (4a), using various acids in place of the cyclohexanecarboxylic acid (CHCA, 2a) in the reaction scheme. The five acids are 4-fluorobenzoic acid (FB, 2b), 4-fluoro-3-methylbenzoic acid (MeFB, 2c), trans-4-fluorocyclohexanecarboxylic acid (FC, 2d), 4-(fluoromethyl)benzoic acid (FMeB, 2e), and 3-nitro-4-(fluoromethyl)benzoic acid (NFMeB, 2f) (see Scheme 1). These compounds were radiolabeled with fluorine-18, and their biological properties were evaluated in rats and compared with those of [11C]carbonyl WAY 100635 ([carbonyl-11C]4a). [Carbonyl-11C]4a cleared the brain with a biological half-life averaging 41 min. The metabolite-corrected blood radioactivity had a half-life of 29 min. [18F]FCWAY ([18F]4d) gave half-lives and intercepts comparable to [carbonyl-11C]4a in the brain, but the blood clearance was faster. [18F]FBWAY ([18F]4b) showed an early rapid net efflux from the whole brain, clearing with a biological half-life of 35 min. The metabolite-corrected blood half-life was 41 min. The comparable whole brain and blood half-lives for Me[18F]FBWAY ([18F]4c) were 16 and 18 min, respectively. For each compound, the corresponding carboxylic acid was identified as a major metabolite in blood. Fluoride was also found after injection of [18F]4d. However, for all compounds there was a good correlation (R > 0.97) between the differential uptake ratio (DUR, (%ID/g) x body weight (g)/100) in individual rat brain regions at 30 min after injection and the concentration of receptors as determined by in vitro quantitative autoradiography in rat. Specific binding ratios [region of interest (ROI)/cerebellum-1] in control studies for cortex (Ctx) and hippocampus (H) were higher for [carbonyl-11C]4a and [18F]4d compared to [18F]4b and [18F]4c. [18F]4d has similar pharmacokinetic properties and comparable specific binding ratios to [carbonyl-11C]4a. Fifty nanomoles of 4a blocked only 30% of the specific binding of [18F]4d, while complete blockade was obtained from co-injection of 200 nmol of 4a (H/Cb-1 from 17.2 to 0.6). [18F]4b and [18F]4c showed lower specific binding ratios than [carbonyl-11C]4a and [18F]4d. [18F]4c was superior to [18F]4b since its specific binding was more readily blocked by 4a. These studies suggest that [18F]4c should be a useful compound to assess dynamic changes in serotonin levels while [18F]4d, with its high contrast and F-18 label, should provide better statistics and quantification for static measurement of 5-HT1A receptor distribution.

Animals↗

In vivo muscarinic binding of 3-(alkylthio)-3-thiadiazolyl tetrahydropyridines.

Based on encouraging in vitro data indicating M2 subtype selectivity, we synthesized, radiolabeled with 18F, and evaluated 3-(3-(2-fluoroethylthio)-1,2,5-thiadiazol-4-yl)-1,2,5,6-tetr ahydro-1-methylpyridine [FE-TZTP], and 3-(3-(3-fluoropropylthio)-1,2,5-thiadiazol-4-yl)-1,2,5,6-tet rahydro-1-methylpyridine [FP-TZTP] for muscarinic subtype selectivity in vivo. [18F]FE-TZTP displays high uptake in vivo but is inhibited only weakly by coinjecting unlabeled P-TZTP. Contrarily, [18F]FP-TZTP shows significant inhibition of uptake by coinjecting unlabeled P-TZTP or the muscarinic agonist L-687,306 (3-(3-cyclopropyl-1,2,4-oxadiazol-5-yl)-1-azabicyclo[2.2.1]heptane ). Using in vivo autoradiography, [18F]FP-TZTP displays regional distribution consistent with M2 subtype distribution. In addition, [18F]FP-TZTP shows specific uptake in the heart at 5 min. Analysis of metabolites in the awake rat brain revealed that the parent compound represents >95% of the extractable activity at 30 min. In vivo studies in rhesus monkeys revealed rapid brain uptake of [18F]FP-TZTP, with clearance sustained over 2 h. Administration of P-TZTP or FP-TZTP (80 nmol/kg) at 60 min after injection of [18F]FP-TZTP results in a significant displacement of brain activity in all regions. Metabolite analysis in monkey plasma shows that parent compound represents 20% of the extractable radioactivity at 40 min postinjection. One metabolite, which increases with time, has similar lipophilicity to the parent. However, based on metabolism in rat we believe metabolites are not in the brain to any significant extent in monkeys during the time of imaging studies. Regional uptake, autoradiographic distribution, and clearance rates in the brain are consistent with the hypothesis that [18F]FP-TZTP is M2 selective in vivo.

Animals↗