[Dysfunction of vaporizers and nitrous oxide: solubility or viscosity?].

Sudden switch of carrier gas from O2 to the N2O/O2 mixture results in an acute decrease in vapour output for a variable delay of time. This has been attributed to the dissolution of N2O in the volatile anaesthetic liquid. The final vapour concentration at steady state had been previously reported to be lower than the concentration dial setting: this was attributed to vaporizer design and to viscosity of carrier gas. When N2O/O2 flow is replaced by O2, the reverse changes occur. To test whether solubility or viscosity is the main factor of the acute changes in vaporizer output when changing the carrier gas, two experiments have been designed. Two types of vaporizers, Cyprane Mark 3 and Dräger Vapor 19, were used to deliver either halothane, or enflurane, or isoflurane. The delivered concentrations were measured in triplicate with an infrared analyzer, zero corrected for N2O, Datex Capnomac and recorded on a Gould polygraph. The analyzer was calibrated before each measure. All measures were obtained at the same dial setting and the same gas flow. To test the solubility hypothesis, the same enflurane Dräger Vapor 19 vaporizer was emptied, dried, saturated with enflurane, emptied and then filled with either 10 or 100 mL of liquid enflurane. To test the viscosity hypothesis, a model of a vaporizer was devised, in which the gas movements are described with the Poiseuille's law. In this model, the delivered concentration F depends on the vapour pressure, the input pressure of the gas flow, the viscosity of the carrier gas and the viscosity of the agent saturated gas.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, Inhalation↗

Fiberoptic bronchoscopy in brain-dead organ donors.

Criteria for selecting lung donors include normal chest X-ray and adequate gas exchange, but normal bronchoscopy is not always required. Thus, we conducted a prospective study of fiberoptic bronchoscopy in 72 brain-dead donors scheduled for multiple organ procurement. Chest X-ray was considered normal in 37 donors (51%), and PaO2 was > 400 mm Hg with an FIO2 of 100% in 34 donors (47%). Fiberoptic bronchoscopy was normal in only 24 donors (33%). In the remaining 48 donors, inhalation of gastric contents (n = 26) or blood (n = 17), pulmonary contusion (n = 5), or purulent bronchial secretions (n = 4) were noted. In the 26 donors with normal chest X-ray and PaO2 > 400 mm Hg with FIO2 of 100%, bronchoscopy was abnormal in 10 donors (38%). In 33 donors, arteriovenous difference in oxygen content (2.4 +/- 0.8 ml O2/100 ml), and pulmonary shunt (0.30 +/- 0.11, range 0.13-0.49) were measured. In the 15 donors with PaO2 > 400 mm Hg, pulmonary shunt was 0.23 +/- 0.07 (range 0.13-0.35). Our study suggests that chest X-ray and arterial blood gas analysis are not sufficient, and that fiberoptic bronchoscopy should be routinely performed to select potential lung donors. Even in brain-dead donors, only the measurement of pulmonary shunt can precisely assess pulmonary gas exchange.

Adult↗