Search PubMed⌕ Search

Biomedical subjects

R D Weiner

Publications and source records attributed to R D Weiner.

At least 37 records · Page 2Linked to original sources

Serum prolactin, electrode placement, and the convulsive threshold during ECT.

This study examines the relationship of serum prolactin changes (delta PRL) to variations in electrode placement after controlling for differences in the convulsive threshold. Previous studies showing greater release of PRL with bilateral (BL) compared with right unilateral (RUL) electrode placement were conducted without knowledge of the convulsive threshold. Twenty-two patients each received threshold RUL, threshold BL, 2.25 times threshold RUL, and 2.25 times threshold BL ECT. Serum PRL was collected 5 min before and 15 min after each electroconvulsive therapy (ECT). The convulsive threshold was greater for BL than RUL electrode placement. delta PRL was greater with BL than RUL ECT at comparable relative stimulus intensities. delta PRL was not correlated with seizure duration or absolute stimulus dose.

Electroconvulsive Therapy↗

The relative ability of three ictal EEG frequency bands to differentiate ECT seizures on the basis of electrode placement, stimulus intensity, and therapeutic response.

Ictal EEG indices show promise for separating individual ECT seizures on the basis of treatment electrode placement (ELPL), relative stimulus intensity (Dose), and expected therapeutic response. One factor impeding the effective clinical implementation of ictal EEG indices for these purposes is uncertainty as to the relative utility of lower and higher frequency EEG activity. Recent articles are contradictory in this regard, but no data exist addressing this issue. As a result, we reanalyzed data from 44 subjects in two studies and compared the relative ability of ictal EEG data in three frequency bands to differentiate seizures as a function of ELPL, Dose, and therapeutic response. We found that the frequency band that best differentiated these groups depended on the EEG measure used, the temporal portion of the seizure, and whether ELPL, Dose, or therapeutic response was being compared.

Algorithms↗

Seizure threshold in electroconvulsive therapy (ECT) II. The anticonvulsant effect of ECT.

To measure the anticonvulsant effects of a course of electroconvulsive therapy (ECT), we used a flexible stimulus dosage titration procedure to estimate seizure threshold at the first and sixth ECT treatments in 62 patients with depression who were undergoing a course of brief pulse, constant current ECT given at moderately suprathreshold stimulus intensity. Seizure threshold increased by approximately 47% on average, but only 35 (56%) of the 62 patients showed a rise in seizure threshold. The rise in seizure threshold was associated with increasing age, but not with gender, stimulus electrode placement, or initial seizure threshold. Dynamic impedance decreased by approximately 5% from the first to the sixth ECT treatment, but there was no correlation between the change in dynamic impedance and the rise in seizure threshold. No relation was found between the rise in seizure threshold and either therapeutic response status or speed of response to the ECT treatment course. These findings confirm the anticonvulsant effect of ECT but suggest that such effects are not tightly coupled to the therapeutic efficacy of moderately suprathreshold ECT.

Adult↗

Seizure threshold in electroconvulsive therapy: I. Initial seizure threshold.

We measured initial seizure threshold by means of a structured stimulus dosage titration procedure in a clinical sample of 111 depressed patients undergoing brief-pulse, constant-current electroconvulsive therapy (ECT). Initial seizure threshold was approximately 60 millicoumbs (mc) (10 Joules) on average, but varied widely (6-fold) across patients. Initial seizure threshold was predicted by four variables: electrode placement (higher with bilateral), gender (higher in men), age (higher with increasing age), and dynamic impedance (inverse relationship). Use of neuroleptic medication was associated with a lower seizure threshold. EEG seizure duration was inversely related to initial seizure threshold, but no other relations with seizure duration were found. These findings may have important clinical implications for stimulus dosing strategies in ECT.

Adult↗

The ictal EEG as a marker of adequate stimulus intensity with unilateral ECT.

Relative stimulus intensity above seizure threshold has been shown to affect therapeutic outcome with unilateral ECT. The authors sought to explore whether a multivariate ictal EEG model would permit ongoing clinical assessment of this parameter. Twenty-five depressed subjects were randomized to either barely (T) or moderately (2.5T) suprathreshold ECT treatments. Seizures in 2.5T subjects had significantly greater ictal spectral amplitude and coherence, greater postictal suppression, and shorter latency until ictal slow-wave onset. A multivariate logistic regression ictal EEG model distinguished between stimulus intensity groups with 90% accuracy. Preliminary evidence suggests a relationship between several ictal EEG indices and therapeutic outcome. A multivariate ictal EEG algorithm holds promise as a tool for clinical determination of adequate stimulus intensity with unilateral ECT.

Adult↗

ECT seizure duration: reliability of manual and computer-automated determinations.

Reliable monitoring of electroencephalographic (EEG) and electromyographic electroconvulsive therapy (ECT) seizure duration has become important as these assessments have become a routine part of the clinical practice of ECT. In this regard, accurate automated seizure duration determinations would be particularly valuable. As a result, the present study was performed to assess the reliability of available computer-automated determinations of seizure duration (Thymatron Model DGx ECT machine; Somatics, Inc.) and to explore the factors upon which such reliability as well as the determinations of experienced raters depend. We found that the experienced human raters had very high interrater reliability, significantly higher than either did with the automated Thymatron DGx ratings. In general, the reliability of all ratings declined in the context of artifact, poor postictal suppression, or an EEG seizure end point that was reached gradually. Reliability was also greater for continuation ECT as compared with the index course. The reliability of Thymatron DGx versus experienced human ratings was particularly sensitive to these factors, ranging from 0.68 when several of these factors were simultaneously present to 0.999 when all these factors were absent.

Adult↗

The present use of electroconvulsive therapy.

Physicians attempting to treat certain severe mental disorders have recently shown renewed interest in electroconvulsive therapy (ECT). A number of technical innovations have made ECT safer, as well as more effective. These innovations include oxygenation, muscular relaxation, unilateral nondominant electrode placement, use of brief-pulse stimuli, titrated stimulus dosing, electroencephalographic (EEG) monitoring, determination of seizure adequacy, and pharmacologic enhancement of treatment response.

Electroconvulsive Therapy↗

Use of ECT in the United States in 1975, 1980, and 1986.

OBJECTIVE: The objective was to analyze nationally representative data from the National Institute of Mental Health (NIMH) to update trends in the use of ECT in the United States. METHOD: The data are estimates from the NIMH Sample Survey Program for 1975, 1980, and 1986, which include representative samples of inpatients in psychiatric facilities in the United States. The authors' analyses use trend data from public general hospitals, private general hospitals, private psychiatric hospitals, and state and county mental hospitals. They report on 126,739 patients who received ECT in 1975, 1980, and 1986, focusing on data from 1980 and 1986. RESULTS: In 1986, 36,558 patients received ECT. This represents a decrease from the 1975 figure (58,667 patients) but no change from 1980 (31,514 patients). ECT was used primarily in private general hospitals (64%) and private psychiatric hospitals and much less often in public general hospitals and state and county mental hospitals. In 1986 over 90% of ECT recipients were white, and 84% had an affective disorder diagnosis. Although 71% of the patients who received ECT were women, hospital type and age were more important than gender in predicting ECT use. Individuals 65 years of age and older received ECT out of proportion to their numbers in inpatient care. CONCLUSIONS: The declining use of ECT in the United States ended in the 1980s. Few African Americans receive ECT, and its use is becoming more targeted toward patients with affective disorders. The amount of services research done on this modality is very small. Basic questions have yet to be answered, including who refers patients for ECT and why, and how ECT fits into the overall course of treatment.

Adolescent↗

Treatment optimization with ECT.

Although electroconvulsive therapy (ECT) is considered to be an effective and safe treatment, as with any treatment, both therapeutic outcome and adverse effects can be expected to vary considerably across patients. It is incumbent upon the practitioner to be aware of factors that serve to influence the benefits and risks associated with this treatment modality. This article provides a brief, clinically oriented overview of many of these factors, including those that may be useful in response prediction, as well as technical modifications of the ECT procedure itself. In addition, a number of suggestions are made concerning promising future avenues of research in this area.

Combined Modality Therapy↗

ECT seizure therapeutic adequacy.

From the beginnings of convulsive therapy, the need for some way to assess the therapeutic adequacy of individual treatments has been apparent. Recent work suggests that seizure therapeutic adequacy and adverse effects are dependent on the extent to which the stimulus exceeds the seizure threshold (relative stimulus intensity). Applying this information in clinical practice is problematic because of the variable rise in the seizure threshold that takes place over the treatment course. Attributes of the ictal electroencephalogram (EEG) show promise for alleviating this problem by serving as a marker of relative stimulus intensity. Obstacles that need to be overcome in order to implement ictal EEG indices as a relative stimulus intensity marker in clinical practice are discussed and include artifacts, how to determine a threshold for deciding adequacy, variation in technique between sites, and inter-individual EEG variation; some strategies for overcoming these hurdles are described. It is anticipated that an ictal EEG algorithm that addresses these issues is likely to be of substantial clinical benefit in the practice of electroconvulsive therapy.

Biomarkers↗

The effects of ECT stimulus dose and electrode placement on the ictal electroencephalogram: an intraindividual crossover study.

Recent evidence suggests that electroconvulsive therapy (ECT) efficacy depends upon both electrode placement and the degree to which stimulus dosage exceeds seizure threshold (T), and not simply on surpassing a minimum seizure duration as has been assumed. In light of these findings and studies reporting ictal electroencephalogram (EEG) differences between bilateral and unilateral ECT, we performed this 19-subject intraindividual crossover study of the effects of dose and electrode placement on the ictal EEG. We found ictal EEG evidence of greater seizure intensity with bilateral than unilateral ECT and with higher dosage (2.25 T) compared with barely suprathreshold stimuli. Seizure duration was not longer with bilateral than unilateral ECT and actually decreased with increased dose. A number of ictal EEG variables separated the unilateral 2.25 T and unilateral T conditions, which reportedly differ in efficacy, and therefore, these EEG measures show promise as markers of treatment adequacy.

Adult↗

Convulsive threshold differences in right unilateral and bilateral ECT.

UNLABELLED: This study examines how the convulsive threshold in electroconvulsive therapy (ECT) varies with electrode placement (bilateral [BL] versus right unilateral [RUL]), age, gender, weight, and the nasion-inion measurements of the head. METHOD: Twenty-eight subjects underwent stimulus dose titration to determine the convulsive threshold. Titration was accomplished for each subject with both electrode placements during the first and second ECT in a balanced design. Head measurements were made prior to the first ECT. Results indicated that the convulsive threshold was higher for BL than RUL, higher for men than women, increased with age, and increased with an increasing nasion-inion measurement in women but not in men. We concluded that the convulsive threshold varies according to the choice of electrode placement, gender, and age as has been reported by others. We additionally report that the convulsive threshold increases with increasing head size as reflected in the nasion-inion distance.

Adult↗

The dexamethasone suppression test and quantitative cerebral anatomy in depression.

To determine whether structural brain abnormalities in patients with depression are related to cortisol state, we examined the relationship between the dexamethasone suppression test (DST) and brain magnetic resonance imaging (MRI) in 40 inpatients with severe depression referred for electroconvulsive therapy (ECT). Prior to ECT, 27 (68%) of the patients exhibited nonsuppression on the DST. Frontal lobe volume was negatively correlated with peak post-dexamethasone cortisone (r = -0.37) and was 13% smaller in DST nonsuppressors than suppressors; these findings were no longer significant after adjustments for age, gender, and cranial size. Lateral and third ventricular volumes were also correlated with peak postdexamethasone cortisol (r = 0.34 and 0.33, respectively), but not after adjustments for age, gender, and cranial size. Subcortical hyperintensity was associated with peak postdexamethasone cortisol and was more common in DST nonsuppressors than suppressors. Again these findings were no longer significant after adjustments for age. Finally, longitudinal DST and brain MRI studies in 11 of these patients revealed no changes in regional brain volumes nor in postdexamethasone cortisol up to six months after ECT. However, within individual patients, postdexamethasone cortisol was positively (and significantly) correlated with frontal lobe volume.

Adult↗

Spectral and topographic analysis of EEG in schizophrenic patients.

The authors performed spectral analysis of electroencephalograms (EEG), recorded awake, with eyes closed, in 13 patients with schizophrenia and 9 age-matched individuals without psychiatric diagnosis. We tested several possible parameterizations of the data, and two data-reduction strategies; these yielded similar results. Comparison of the two groups revealed a relative increase in alpha frequency activity in the frontal regions in the patient group. The authors believe that this finding is consistent with data from neuropsychologic tests, metabolic imaging studies, and evoked potential studies that suggest impaired activation of frontal brain areas in patients with schizophrenia.

Adult↗

Quantitative cerebral anatomy in depression. A controlled magnetic resonance imaging study.

Magnetic resonance imaging was used to examine cerebral anatomy in 48 inpatients with severe depression who were referred for electroconvulsive therapy and in 76 normal control subjects. The magnetic resonance imaging measures included determinations of regional cerebral volumes and ratings of the frequency and severity of cortical atrophy, lateral ventricular enlargement, and subcortical hyperintensity. The mean total frontal lobe volume was found to be 7% smaller in the inpatients with severe depression (235.88 mL) than in the normal control subjects (254.32 mL)--a difference that was statistically significant even after adjusting for the effects of age, sex, education, and intracranial size. No group differences were observed in the volumes of the cerebral hemispheres, the temporal lobes, or the amygdala-hippocampal complex, nor in the frequency of cortical atrophy. Neither did the groups differ with respect to the total volumes of the lateral and third ventricles, nor in the frequency of lateral ventricular enlargement. Patients with depression had a significantly higher frequency of subcortical hyperintensity in the periventricular white matter, with an odds ratio of 5.32.

Adult↗