Paroxysmal bundle branch block of supraventricular origin: a possible source of misdiagnosis in detecting ventricular tachycardia using time domain analyses of intraventricular electrograms.

Current implantable antitachycardia devices use several methods for differentiating sinus rhythm (SR) from supraventricular tachycardia (SVT) or ventricular tachycardia (VT). These methods include sustained high rate, the rate of onset, changes in cycle length, and sudden onset. Additional methods for detecting VT include techniques based upon ventricular electrogram morphology. The morphological approach is based on the assumption that the direction of cardiac activation, as sensed by a bipolar electrode in the ventricle, is different when the patient is in SR as compared to VT. Whether paroxysmal bundle branch block of supraventricular origin (BBB) can be differentiated from VT has not been determined. In this study, we compared the morphology of the ventricular electrogram during sinus rhythm with a normal QRS (SRNIQRS) or SVT with a normal QRS (SVTNIQRS) with the morphologies of BBB and VT in 30 patients undergoing cardiac electrophysiology studies. Changes in ventricular electrogram morphology were determined using three previously proposed time domain methods for VT detection: Correlation Waveform Analysis (CWA), Area of Difference (AD), and Amplitude Distribution Analysis (ADA). CWA, AD, and ADA distinguished VT from SRNIQRS or SVTNIQRS in 16/17 (94%), 14/17 (82%), and 12/17 (71%) patients, and BBB from SRNIQRS or SVTNIQRS in 15/15 (100%), 13/15 (87%), and 6/15 (40%) patients, respectively. However, the ranges of values during BBB using these methods overlapped with ranges of values during VT in all cases for CWA, AD, and ADA. Hence, BBB may be a source of misdiagnosis in detecting VT when these time domain methods are used for ventricular electrogram analysis.

Adolescent↗

Intraventricular electrogram analysis for ventricular tachycardia detection: statistical validation.

Time-domain analysis of intraventricular electrogram morphology during ventricular tachycardia (VT) and sinus rhythm or atrial fibrillation (SR/AF) has been proposed as a method for increasing the specificity of pathological tachycardia detection by antitachycardia devices. However, few studies have validated the use of such analysis with statistical methods. When statistical methods have been utilized, it has been assumed that the distribution of the values derived from analysis of the intracardiac electrograms have had a normal (gaussian) distribution. In this study, we sought to determine whether: (1) the distribution of values derived from analysis of intracardiac electrogram during SR/AF and VT is gaussian or nongaussian; and (2) the discrimination of monomorphic VT from SR/AF using SR/AF templates can be validated statistically. Two previously proposed time-domain methods--correlation waveform analysis (CWA) and area of difference (AD)--were selected for evaluation of 29 patients with 33 distinct, sustained monomorphic VTs. An initial SR/AF template was used to analyze subsequent SR/AF and VT passages with a minimum of 50 consecutive depolarizations using a "best-fit" alignment. The values derived from each analysis were examined subsequently for skewness (asymmetry) and kurtosis (shape) using two-tailed tests (P less than 0.02). For passages of SR/AF, a normal (gaussian) distribution was present in only 24% (CWA), and 45% (AD); for passages of VT, normal distribution was present in only 58% for both CWA and AD. Using appropriate statistical testing with nonparametric tolerance intervals, CWA and AD discriminated VT from SR/AF in 29 out of 33 (88%), and 30 out of 33 (91%) instances, respectively, with 95% confidence.(ABSTRACT TRUNCATED AT 250 WORDS)

Atrial Fibrillation↗

Discrimination of retrograde from anterograde atrial activation using intracardiac electrogram waveform analysis.

The prevention of pacemaker-mediated tachycardias requires a safe, reliable method for distinguishing retrograde from anterograde atrial activation by dual chamber pacemakers. In this study, a technique was developed to detect the morphological change that occurs in the waveform of the intra-atrial electrogram during retrograde atrial activation. The method employed for waveform analysis is based upon statistical correlation. In 19 patients undergoing electrophysiological studies, atrial electrograms were recorded from bipolar endocardial electrodes during sinus rhythm and 1:1 retrograde atrial depolarization while undergoing right ventricular pacing. Data were digitally sampled at 750, 1,000, and 1,500 Hz. Templates of anterograde atrial depolarization were constructed by signal averaging waveforms from an initial sinus rhythm passage. These were used for analysis of anterograde depolarizations from a subsequent passage of sinus rhythm and a passage of known retrograde atrial depolarization. In all 19 cases, a patient-specific threshold could be derived to separate anterograde from retrograde atrial depolarizations using 1,000 Hz and 1,500 Hz sampling rates. However, at a sampling rate of 750 Hz, separation of anterograde from retrograde atrial activation was possible in only 16/19 patients (84%). We conclude that correlation waveform analysis of a suitably sampled atrial electrogram is a reliable method of discriminating retrograde atrial depolarization from anterograde atrial depolarization in intracardiac electrograms.